You are on page 1of 5

‫لوحة اإلدخال‬

m ‫طول خط الضخ‬ 1,400.0


m H2o ‫الضاغط الستاتيكي‬ 25.0
inch ‫القطر الداخلي لألنبوب‬ 5.0
---------- ‫ثابت هايزن ويليامز‬ 120.0
m H2o ‫الطول المكافئ للضياعات المحلية‬ 140.0

50 System curve - ‫منحني النظام‬


45

40

35
H mH2O

30

25

20

15

10

0
0 10 20 30 40 50 60

Q m3/hr

l = length of pipe (m) 1,540.0

120.0
c = Hazen-Williams roughness constant
q = volume flow (m³/hr) 50

5.0
dh = inside or hydraulic diameter (inches)
q = volume flow (liter/sec) 13.89
dh = inside or hydraulic diameter (mm) 127
Calculated Pressure Loss
f = friction head loss in mm of water per 1287.88
100 m of pipe (mm H20 per 100 m pipe)
f = friction head loss in mm of water per 1.29
100 m of pipe (m H20 per 100 m pipe)
f = friction head loss in kPa per 100 m of 12.63
pipe (kPa per 100 m pipe)
Head loss (mm H20) 19833.38
Head loss (kPa) 194.57
Head loss (m H20) 19.83

Calculated Flow Velocity


v = flow velocity (m/s) 1.10

m H2o ‫الضاغط الستاتيكي‬ 25.0


m H2o ‫ضياعات االحتكاك‬ 19.8

m H2o ‫الضاغط الكلي‬ 44.8


‫‪50‬‬ ‫‪45‬‬ ‫‪40‬‬ ‫‪35‬‬ ‫‪30‬‬ ‫‪25‬‬ ‫‪20‬‬ ‫‪15‬‬ ‫‪10‬‬ ‫‪5‬‬
‫‪Q1‬‬
‫‪H pump‬‬ ‫‪32‬‬ ‫‪36‬‬ ‫‪39‬‬ ‫‪41.5‬‬ ‫‪43.5‬‬ ‫‪45.5‬‬ ‫‪47‬‬ ‫‪48‬‬ ‫‪49‬‬ ‫‪50‬‬

‫‪H sys‬‬ ‫‪44.8‬‬ ‫‪41.3‬‬ ‫‪38.1‬‬ ‫‪35.2‬‬ ‫‪32.7‬‬ ‫‪30.5‬‬ ‫‪28.6‬‬ ‫‪27.1‬‬ ‫‪26.0‬‬ ‫‪25.3‬‬

‫يتم ادخال فقط الخاليا المحددة باللون البرتقالي أما باقي الخاليا فيتم حسابها آليا‬
‫تصميم ‪ :‬م هيثم بكور ‪ -‬هدية لألخوة العاملين في مجال المياه و اإلصحاح البيئي‬

‫‪60‬‬
‫نقطة العمل للمضخة‪- Duty Point‬‬

‫‪50‬‬

‫‪40‬‬
‫‪H mH2O‬‬

‫‪30‬‬

‫‪20‬‬

‫‪10‬‬

‫‪0‬‬
‫‪0‬‬ ‫‪5‬‬ ‫‪10‬‬ ‫‪15‬‬ ‫‪20‬‬ ‫‪25‬‬ ‫‪30‬‬ ‫‪35‬‬ ‫‪40‬‬ ‫‪45‬‬ ‫‪50‬‬ ‫‪55‬‬

‫‪60‬‬ ‫‪Q m3/hr‬‬


‫‪H pump‬‬ ‫‪H sys‬‬

‫‪1540‬‬ ‫‪1540‬‬ ‫‪1540‬‬ ‫‪1540‬‬ ‫‪1540‬‬ ‫‪1540‬‬ ‫‪1540‬‬ ‫‪1540‬‬ ‫‪1540‬‬ ‫‪1540‬‬

‫‪120‬‬ ‫‪120‬‬ ‫‪120‬‬ ‫‪120‬‬ ‫‪120‬‬ ‫‪120.0‬‬ ‫‪120.0‬‬ ‫‪120.0‬‬ ‫‪120.0‬‬ ‫‪120.0‬‬

‫‪45‬‬ ‫‪40‬‬ ‫‪35‬‬ ‫‪30‬‬ ‫‪25‬‬ ‫‪20‬‬ ‫‪15‬‬ ‫‪10‬‬ ‫‪5‬‬ ‫‪0‬‬

‫‪5.0‬‬ ‫‪5‬‬ ‫‪5‬‬ ‫‪5‬‬ ‫‪5.0‬‬ ‫‪5.0‬‬ ‫‪5.0‬‬ ‫‪5.0‬‬ ‫‪5.0‬‬ ‫‪5.0‬‬

‫‪12.50‬‬ ‫‪11.11‬‬ ‫‪9.72‬‬ ‫‪8.33‬‬ ‫‪6.94‬‬ ‫‪5.56‬‬ ‫‪4.17‬‬ ‫‪2.78‬‬ ‫‪1.39‬‬ ‫‪0.00‬‬
‫‪127‬‬ ‫‪127‬‬ ‫‪127‬‬ ‫‪127‬‬ ‫‪127‬‬ ‫‪127‬‬ ‫‪127‬‬ ‫‪127‬‬ ‫‪127‬‬ ‫‪127‬‬
1059.58 851.92 665.27 500.05 356.75 235.99 138.52 65.37 18.11 0.00

1.06 0.85 0.67 0.50 0.36 0.24 0.14 0.07 0.02 0.00

10.39 8.36 6.53 4.91 3.50 2.32 1.36 0.64 0.18 0.00

16318 13120 10245 7701 5494 3634 2133 1007 279 0


160.07 128.70 100.50 75.54 53.90 35.65 20.93 9.88 2.74 0.00
16.32 13.12 10.25 7.70 5.49 3.63 2.13 1.01 0.28 0.00

0.99 0.88 0.77 0.66 0.55 0.44 0.33 0.22 0.11 0.00

25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0
16.3 13.1 10.2 7.7 5.5 3.6 2.1 1.0 0.3 0.0

41.3 38.1 35.2 32.7 30.5 28.6 27.1 26.0 25.3 25.0
‫‪0‬‬ ‫‪m3/hr‬‬ ‫قيمة التدفق‬ ‫يتم إدخال قيم هذا السطر من كتلوك المضخة‬
‫‪51‬‬ ‫‪m H2o‬‬ ‫ضاغط المضخة ‪ -‬ادخال‬ ‫يتم إدخال قيم هذا السطر من كتلوك المضخة‬
‫‪25.0‬‬ ‫‪m H2o‬‬ ‫ضاغط النظام ‪ -‬من البرنامج‬ ‫يتم حساب قيم هذا السطر اتوماتيكيا من البرنامج‬

‫يتم ادخال فق‬


‫تصميم ‪ :‬م هي‬

‫‪45‬‬ ‫‪50‬‬ ‫‪55‬‬