You are on page 1of 1

BRIDGE PROTECTION PILES SETTING OUT DETAILS BRIDGE PROTECTION PILES SETTING OUT DETAILS

ANTICIPATED SETTING OUT ANTICIPATED SETTING OUT


PILE Ref. PILE TYPE CUT OFF LEVEL PILE Ref. PILE TYPE CUT OFF LEVEL
TOE LEVEL CO-ORDINATES (X,Y) TOE LEVEL CO-ORDINATES (x,Y)
PVCN1 CHS 1219 x 25mm PILE -3.65mOD -22.000 to -23.200 660746.050, 612807.742 PVCS1 CHS 1219 x 25mm PILE -3.65mOD -27.900 to -28.900 660724.410, 612740.879

PVCN2 CHS 1219 x 25mm PILE -3.65mOD -22.000 to -23.200 660742.195, 612803.819 PVCS2 CHS 1219 x 25mm PILE -3.65mOD -27.900 to -28.900 660723.584, 612746.317

PVCN3 CHS 1219 x 25mm PILE -3.65mOD -22.000 to -23.200 660738.340, 612799.896 PVCS3 CHS 1219 x 25mm PILE -3.65mOD -27.900 to -28.900 660722.759, 612751.754

PVCN4 CHS 1219 x 25mm PILE -3.65mOD -22.000 to -23.200 660741.269, 612808.584 PVCS4 CHS 1219 x 25mm PILE -3.65mOD -27.900 to -28.900 660720.042, 612742.997

PVCN5 CHS 1219 x 25mm PILE -3.65mOD -22.000 to -23.200 660737.414, 612804.661 PVCS5 CHS 1219 x 25mm PILE -3.65mOD -27.900 to -28.900 660719.217, 612748.435

PVCN6 CHS 1219 x 25mm PILE -3.65mOD -22.000 to -23.200 660670.090, 612832.326 PVCS6 CHS 1219 x 25mm PILE -3.65mOD -27.900 to -28.900 660648.450, 612765.463

PVCN7 CHS 1219 x 25mm PILE -3.65mOD -22.000 to -23.200 660670.916, 612826.888 PVCS7 CHS 1219 x 25mm PILE -3.65mOD -27.900 to -28.900 660652.305, 612769.386

PVCN8 CHS 1219 x 25mm PILE -3.65mOD -22.000 to -23.200 660671.741, 612821.450 PVCS8 CHS 1219 x 25mm PILE -3.65mOD -27.900 to -28.900 660656.160, 612773.309

PVCN9 CHS 1219 x 25mm PILE -3.65mOD -22.000 to -23.200 660674.458, 612830.207 PVCS9 CHS 1219 x 25mm PILE -3.65mOD -27.900 to -28.900 660653.231, 612764.621

PVCN10 CHS 1219 x 25mm PILE -3.65mOD -22.000 to -23.200 660675.283, 612824.770 PVCS10 CHS 1219 x 25mm PILE -3.65mOD -27.900 to -28.900 660657.086, 612768.544

PVCN11 CHS 762 x20.6mm PILE +3.4mOD -22.000 to -23.200 660720.989, 612795.000 PVCS11 CHS 762 x20.6mm PILE +3.4mOD -27.900 to -28.900 660711.567, 612765.887
PVCN12 CHS 762 x20.6mm PILE +3.4mOD -22.000 to -23.200 660710.728, 612795.772 PVCS12 CHS 762 x20.6mm PILE +3.4mOD -27.900 to -28.900 660702.800, 612771.274
PVCN13 CHS 762 x20.6mm PILE +3.4mOD -22.000 to -23.200 660701.215, 612798.852 PVCS13 CHS 762 x20.6mm PILE +3.4mOD -27.900 to -28.900 660693.285, 612774.353

PVCN14 CHS 762 x20.6mm PILE +3.4mOD -22.000 to -23.200 660691.700, 612801.931 PVCS14 CHS 762 x20.6mm PILE +3.4mOD -27.900 to -28.900 660683.771, 612777.433

PVCN15 CHS 762 x20.6mm PILE +3.4mOD -22.000 to -23.200 660682.933, 612807.317 PVCS15 CHS 762 x20.6mm PILE +3.4mOD -27.900 to -28.900 660673.510, 612778.204

C D

M
1

PRELIMINARY TEST PILE SETTING OUT DETAILS


PILE ANTICIPATED SETTING OUT
PILE TYPE CUT OFF LEVEL COMMENTS
Ref. TOE LEVEL CO-ORDINATES (X,Y)
TP2 CHS 1219 x 25mm PILE +4.300 -1.9000 660892.000, 612942.000 CONCRETE INFILL

Project
Detailed Design
XYT2
Stage

Client: No. Revision Date By Chk'd App'd


C01 CONTRACT ISSUE 16/12/2022 LW CS TD ARENA HOUSE Project
WATERFORD CITY PUBLIC INFRASTRUCTURE PROJECT
ARENA ROAD Title
SANDYFORD
DUBLIN 18
IRELAND Drawing SUSTAINABLE TRANSPORT BRIDGE
t +353 (0) 1 294 0800 Title FENDER PILING LAYOUT & DETAILS SHEET 1
www.rod.ie
Consulting Engineers Project Originator Volume Location Type Role Number
Civil - Structural - Transportation - Environmental Drawing
Kevin Cleary & Associates Number WPIP - ROD - STR - S30 - DR - CB - 501605
Drawn Designed Checked Approved Suitability Code - Description
Consulting Engineers
OB JOV DC TD A1 - Approved/Accepted Scale (A1) as shown Date: Sept' 2019 Job No: 18.141 Rev: C01

16 December 2022 12:22:54 \\RODDUBFP1\J\2018\18141\18141-02_WIP\08 MODELS\01 CAD\01 DWG\02 STG 2 - DETAILED DESIGN\10-ST BRIDGE\LW UPDATES\WPIP-ROD-STR-S30-DR-CB-501605_FENDER PILING LAYOUT & DETS SHT1.DWG DO NOT SCALE USE FIGURED DIMENSIONS ONLY