Professional Documents
Culture Documents
Web: www.eastrongroup.com
E-mail: sales@eastrongroup.com
Tel: +86-573-83698881 Fax: +86-573-83698883
CHINA . JIAXING
Add: No.1369,Chengnan Rd. Jiaxing, Zhejiang, 314001, China
ISO9001:2015 MID
COMPANY INTRODUCTION
Eastron Electronic Co., Ltd., headquartered in Jiaxing, China, is one of the leading high-tech manufacturer and supplier
Persuing the excellence of quality
for electricity products and energy measurement solutions. Over the years, we have developed a rich range of electricity
meters, sensors, communication modules and management systems. Our products are widely used in such applications as:
Original Equipment Manufacturers (Switchboard/ Panel Boards, EV Charging Points and Infrastructures ) Climbing the peak of technology
System Integrators for remote monitoring (Energy Analysis, Smart Buildings and Billing Applications)
Renewable energy (Solar, Wind )
Eastron keeps investing on the research and development of new technology and new products on electricity metering.
We have energetic and innovative development teams in both China and UK. That help us keep the competitive edge in
the market. The collaboration with leading university and institution also brings many cutting-edge technology into our
products. To make sure the reliability of the products, Eastron has setup own professional lab that can performs EMC, LVD,
Accuracy and environment tests according to IEC, EN, GB, UL standards.
With more than 40 patented technologies on software, embedded software and hardware, Eastron has been awarded with “
High-tech Enterprise” and “High-tech R&D Centre of Electricity Application”. Eastron strictly follows ISO 9001 Quality manage-
ment system, and the production is approved by SGS according to MID standard.
PROFESSIONAL MANUFACTURER OF METERS
We have 55000 ft2 fully ESD-controlled production facility. The production covers SMT, Wave soldering, Automatic DIP,
Calibration, Aging etc. All products are well protected, properly proceeded, precisely calibrated and fully tested. Automation
is widely used in processing. Eastron runs the ERP and MES systems, which make sure all materials, products and production
information are under control and traceable.
Create value to and grow up with our partners is our mission. Eastron provides not only the high quality and innovative
products, but also first class service to all our customers. We have professional team for technical supports and aftersales
services. We have provided products and services to more than 50 countries in Europe, Asia-Pacific, America, Middle East,
and Africa. We pride ourselves on having long term partners globally that allow us to further our growth and bring our
innovation and quality to the market.
What’s MID?
The Measuring Instruments Directive (2014/32/EU) is a directive by the European Union, which seeks to harmonise many aspects of legal metrology across all
member states of the EU. Its most prominent tenet is that all kinds of meters which receive a MID approval may be used in all countries across the EU.
The Directive also imposes product certification according to the EN50470-1/-3 standards, as well as design certification (Module B) and manufacturing process
certification(Module D) by a Notified Body. In order to ensure product traceability and guarantee its metrological value, thus to protect consumers.
ROUTER
ETHERNET SERVER
WIFI GPRS
Which products of us are MID approved by SGS. SMART X96-I SMART X96-J
ESP-4
ESP-6 ESP-5
Till present, Eastron has the MID approved models LAN ENERGY METERS
R S 485
SMART X
R S 485 R S 485 R S 485
ESP-2
SDM120 Series / SGS0141 SDM120CT Series / SGS0141 SDM220 Series / SGS0172 SDM230 Series / SGS0206
SDM120M
1Ph Lora meter ESP-7
SDM230M
SDM630M
R S 485
SMART X
M-Bus
Active Energy(kWh) Pulse output SDM72CTM 3X230/400V,0.25~5(6)A Active Energy(kWh & W), Imp & Exp, Resettable RS485 Modbus +2 Pulse Output
SDM 120D/DB MID 230V / 110V ,0.25~5(45)A
SDM 120P MID 230V / 110V ,0.25~5(45)A Multi-parameters, Imp & Exp 2 Pulse output
SDM 120M MID 230V / 110V ,0.25~5(45)A Multi-parameters, Imp & Exp RS485 Modbus + 2 Pulse Output
SDM 120MB MID 230V / 110V ,0.25~5(45)A Multi-parameters, Imp & Exp Mbus + 2 Pulse Output
SDM72 SERIES Three Phase
SDM 120CTM MID 230V / 110V ,0.25~5(6)A Multi-parameters, Imp & Exp RS485 Modbus + 2 Pulse Output
SDM 120CTP MID 230V / 110V ,0.25~5(6)A Multi-parameters, Imp & Exp 2 Pulse output
SDM 120CT-MB MID 230V / 110V ,0.25~5(6)A Multi-parameters, Imp & Exp RS485 Mbus +2 Pulse Output Model Specifications Description Output
SDM72D MID 3X230(400)V,0.5~10(100)A,50/60Hz Active Energy(kWh) Pulse Output
SDM 120CT-MV 230V / 110V ,100mV CT Multi-parameters, Imp & Exp RS485 Modbus + 2 Pulse Output
SDM72DR MID 3X230(400)V,0.5~10(100)A,50/60Hz Active Energy(kWh & W), Resettable Pulse Output
SDM72BI MID 3X230(400)V,0.5~10(100)A,50/60Hz Active Energy(kWh & W), Imp & Exp, Resettable 2 Pulse Output
SDM72DM 3X230(400)V,0.5~10(100)A,50/60Hz Active Energy(kWh & W), Imp & Exp, Resettable RS485 Modbus +2 Pulse Output
SDM220 SERIES Single Phase
MID
SDM220Mbus MID 230V/110V,0.25~5(100)A Multi-parameters, Imp & Exp Mbus +2 Pulse Output
Model Specifications Description Output
SDM220MT MID 230V/110V,0.25~5(100)A Multi-parameters, Imp & Exp , 4 Tariffs RS485 Modbus +2 Pulse Output
SDM630Pulse MID 3X230/400V,0.5~10(100)A Multi-parameters, Imp & Exp 2 Pulse Output
SDM220Pulse MID 230V/110V,0.25~5(100)A Multi-parameters, Imp & Exp Pulse Output
SDM630Std MID 3X230/400V,0.5~10(100)A Active Energy(kWh),Imp & Exp (kWh & W) RS485 Modbus +2 Pulse Output
SDM220Std MID 230V/110V,0.25~5(100)A Imp & Exp (kWh & W) RS485 Modbus +2 Pulse Output RS485 Modbus +2 Pulse Output
SDM630Modbus MID 3X230/400V,0.5~10(100)A Multi-parameters, Imp & Exp
SDM630Mbus MID 3X230/400V,0.5~10(100)A Multi-parameters, Imp & Exp Mbus+2 Pulse Output
SDM630MT MID 3X230/400V,0.5~10(100)A, Multi-parameters, Imp & Exp, 4 Tariff ( RTC) RS485 Modbus +2 Pulse Output
SDM230 SERIES Single Phase
Multi-parameters, Imp & Exp, 2 Tariff (Dual Power Source) RS485 Modbus +2 Pulse Output
SDM630-2T MID 3X230/400V,0.5~10(100)A
SDM230Bi MID 230V,0.5~10(100)A Active Energy(kWh & W), Imp &Exp, Resettable, Imp & Exp SDM630Pulse V2 MID 3X230/400V,0.5~10(100)A Multi-parameters, Imp & Exp 2 Pulse Output
Pulse Output
SDM230Modbus 230V,0.5~10(100)A Multi-parameters, Imp & Exp SDM630Std V2 MID 3X230/400V,0.5~10(100)A Active Energy(kWh),Imp & Exp (kWh & W) RS485 Modbus +2 Pulse Output
MID RS485 Modbus +2 Pulse Output
SDM230Mbus MID 230V,0.5~10(100)A Multi-parameters, Imp & Exp SDM630Modbus V2 MID 3X230/400V,0.5~10(100)A Multi-parameters, Imp & Exp RS485 Modbus +2 Pulse Output
Mbus+2 Pulse Output
SDM230Pulse 230V,0.5~10(100)A Multi-parameters, Imp & Exp SDM630Mbus V2 MID 3X230/400V,0.5~10(100)A Multi-parameters, Imp & Exp Mbus+2 Pulse Output
MID RS485 Modbus +2 Pulse Output
SDM230Standard MID 230V,0.5~10(100)A Active Energy(kWh),Imp & Exp (kWh & W) SDM630MT V2 MID 3X230/400V,0.5~10(100)A, Multi-parameters, Imp & Exp, 4 Tariffs ( RTC) RS485 Modbus +2 Pulse Output
RS485 Modbus +2 Pulse Output
SDM230-2T MID 230V,0.5~10(100) Multi-parameters, Imp & Exp, 2 Tariff ( Dual Power Source) SDM630-2T V2 MID 3X230/400V,0.5~10(100)A Multi-parameters, Imp & Exp, 2 Tariffs (Dual Power Source) RS485 Modbus +2 Pulse Output
RS485 Modbus +2 Pulse Output
SDM230-LoRaMESH 230V,0.5~10(100) Multi-parameters, Imp & Exp
LoRaMesh +2 Pulse Output
SDM230-LoRaWAN 230V,0.5~10(100) Multi-parameters, Imp & Exp LoRaWAN+2 Pulse Output SDM630 MCT SERIES Three Phase
SDM630MCT-Mbus MID 3X230/400V,1A or 5A Multi-parameters, Imp & Exp Mbus +2 Pulse Output
Model Specifications Description Output
SDM630MCT-2T MID 3X230/400V,1A or 5A Multi-parameters, Imp & Exp, 2 Tariff (Dual Power Source) RS485 Modbus +2 Pulse Output
SDM320Y-D 230V,0.5~10(100)A Energy(kWh) Pulse Output
SDM630MCT-MT MID 3X230/400V,1A or 5A Multi-parameters, Imp & Exp, 4 Tariff ( RTC) RS485 Modbus +2 Pulse Output
SDM320E 230/110V,0.5~10(100)A Energy(kWh) , 1P3W Pulse Output
Energy(kWh) , 1P3W RS485 Modbus +Pulse Output SDM630MCT-MV 3X230/400V, 333mV CT Multi-parameters, Imp & Exp RS485 Modbus +2 Pulse Output
SDM320E-M 230V,0.5~10(100)A
SDM320Y-RF 230, 0.5~10(80)A Multi-parameters, Imp & Exp, Prepaid RS485 Modbus + Pulse output SDM630MCT-RJ 3X230(400)V,100mA or 333mV CT Multi-parameters, Imp & Exp, Rj12 CTs RS485 Modbus
SDM630MCT-2L 3X230(400)V,100mA or 333mV CT Multi-parameters, Imp & Exp, Multi-Circuit RS485 Modbus
SDM630MCT-LoRa 3X230(400)V,100mA or 333mV CT Multi-parameters, Imp & Exp LoraMESH+2 Pulse Output
SDM630MCT-LoRaWAN 3X230(400)V,100mA or 333mV CT Multi-parameters, Imp & Exp LoraWAN+2 Pulse Output
SDM630MCT-RC 3X230(400)V,100mA or 333mV CT Multi-parameters, Imp & Exp, Rogowski coil RS485 Modbus +2 Pulse Output
SDM530CT-MT 3X230(400)V,1A or 5A Multi-parametters, Imp & Exp, 4 tariff (RTC) RS485 Modbus +2 Pulse output
SMART X835 SERIES Three Phase
SDM320C 230V, 0.5~10(80)A Multi-parametters, Imp & Exp RS485 Modbus + Pulse output 3x230/400V, 1A /5A Multi-parameters; CT & PT programmable;
Smart X835B RS 485 Modbus+2 Pulse output
3P4W, 3P3W,1P2W Class 1.0 / 0.5s ; 2~31stTHD; Aux. power supply
SDM320Y 230V, 0.5~10(80)A Multi-parametters, Imp & Exp, Prepaid RS485 Modbus + Pulse output
3x230/400V, 1A /5A Multi-parameters; CT & PT programmable;
Multi-parametters, Imp & Exp RS485 Modbus + Pulse output Smart X835-AO RS 485 Modbus+2AO+2 Pulse output
SDM530C 3X230(400)V, 3x0.5~10(80)A 3P4W, 3P3W,1P2W Class 1.0 / 0.5s; 2AO; 2~31stTHD; Aux. power supply
SDM530Y 3X230(400)V, 3x0.5~10(80)A Multi-parametters, Imp & Exp, Prepaid RS485 Modbus + Pulse output 3x230/400V, 1A /5A Multi-parameters; CT & PT programmable; Aux. power supply;
Smart X835 DIO RS 485 Modbus+2DI/DO+2 Pulse output
3P4W, 3P3W,1P2W Class 1.0 / 0.5s ; 2 DO; 2 DI ; 2~31stTHD
MCS-I32 3x CT operated RJ12 input Current , power, energy, THD-i, Overcurrent,Multi-Parameters,THD,Demand,Alarm Smart Connect X835 MV 3x230(400)V AC, 333mV Multifunction, Class 1.0 / 0.5s , 31st THD RS485 Modbus+ 2Pulse output
Model Input Output Power supply Model Primary Current Secondary Output Accuracy
ESP-2100 RS232/485/422 x1; 1200~115200bps Ethernet TCP 10/100 Mbps 9~24V DC, 350W ESCT-RJ335 60,100,125,150,200,250A 333mV / 100mV / 100mA 0.5 / 1
ESP-2200 RS232/485/422 x2; 1200~115200bps Ethernet TCP 10/100 Mbps 9~24V DC, 4W ESCT-RJ345 2501300,400,500,630A 333mV / 100mV / 100mA 0.5 / 1
ESP-2400 RS232/485/422 x4; 1200~115200bps Ethernet TCP 10/100 Mbps 9~24V DC, 4W ESCT-RJ16 5,10,20,30,50,100,150A 100mV 0.5 / 1
ESP-2800 RS232/485/422 x8; 1200~115200bps Ethernet TCP 10/100 Mbps 9~24V DC, 6W ESCT-RJ24 10,50,100,200,300A 100mV 0.5 / 1
ESP-2120 M-Bus EN13757-3; 300~9600bps Ethernet TCP 10/100 Mbps 9~24V DC, 6W ESCT-RJ36 20,50,100,200,300,400,500,600A 100mV 0.5 / 1
Model Input Output Power supply Model Primary Current Secondary Current Accuracy
ESP-5100 RS232/485/422; 1200~115200bps GPRS 900Mhz/1800Mhz ; Ethernet TCP 9~24V DC, 170mA@9V 0.5 / 1
ESCT-C325 60,100,125,150,200A 5A /1A
ESP-5305 RS232/485/422; 1200~115200bps 3G / 4G ; Ethernet TCP 9~24V DC, 200mA@9V 0.5 / 1
ESCT-C335 60,100,125,200,250A 5A /1A
ESCT-U SERIES Split Core ESRD TMS SERIES Digital multifunction time relay
ESRD-TMS1 AC/DC 24-240V,50/60Hz 1C/O+1NO contacts, 0s-99h59min59sec, Backlit, LCD disply 2 Module
ESCT-U125 50,100,125,200,250,400,600,630A 333mV 0.5 / 1
ESRD-TMS2 AC/DC 24-240V,50/60Hz 1C/O+1NO contacts,0-9999s,0-9999min , Backlit, LCD disply 2 Module
ESCT-U200 100,250,400,630,800,1000,2000A 333mV 0.5 / 1
ESCT-U300 400,800,1000,1500,2500,3000,5000A 333mV 0.5 / 1 ESRD TPA SERIES Single channel astronomical time switch
t1
ESRD-TPA1 AC220-240V,50/60Hz Single Channel,40 programs, LCD display, Holiday mode, Automatic 2 Module
Model Primary Current Secondary Current Accuracy
ESCT-RC16 100A 333mV / 100mV 0.5 / 1
ESCT-RC24 300A 333mV / 100mV 0.5 / 1 ESRD TPW SERIES Digital weekly time switch
ESCT-RC36 600A 333mV / 100mV 0.5 / 1
ESCT-RC60 500A 333mV / 100mV 0.5 / 1
Model Specifications Description Size
ESCT-RC100 1000A 333mV / 100mV 0.5 / 1
t1
OFFStart
ESRD-TPW1 AC220-240V,50/60Hz Single Channel,40 programs, LCD display, Holiday mode, Automatic 2 Module
ESCT-RC105 1500A 333mV / 100mV 0.5 / 1
ESRD-TPW2 AC/DC24-264V,50/60Hz Double Channel,100 programs, Backlit, LCD , Holiday mode, Automatic 2 Module
ESCT-RC150 3000A 333mV / 100mV 0.5 / 1
ESCT-RC200 6000A 333mV / 100mV 0.5 / 1
ESCT-RC240 10000A 333mV / 100mV 0.5 / 1
ESRD ST SERIES Twilight switch
ESRS-TM12 A1-A2:AC220V; A3-A2; AC/ DC24V,50/60Hz 10 operating modes,10 time ranges, LED indication 1 Module
ESCT-DM SERIES Solid Core
ESRS-TM14 AC/DC 12-240V,50/60Hz 10 operating modes,10 time ranges, LED indication 1 Module
ESRS-TM23 AC/DC 24-240V,50/60Hz 10 operating modes,10 time ranges, LED indication 1 Module
Model Primary Current Secondary Current Accuracy
ESCT-DM20/30 50,60,75,80,100,125,150,200,250,300 A 5A 1
ESCT-DM20/35 50,60,75,80,100,125,150,200,250,300 A 5A 1
ESRS TSL SERIES Staircase light timer
Specification Accuracy
Nominal voltage(Un) 120V or 230V ac Voltage,Current 0·5%
Operational voltage 80%~120% of Un Frequency 0·2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM120 Modbus / Mbus/Pulse - AC voltage withstand 4KV for 1 minute
6KV-1.2µS
Active power , Apparent power ±1% of range maximum
- Impulse voltage withstand Reactive power ±1% of range maximum
SINGLE PHASE MULTI-FUNCTION ENERGY METER
Basic current (Ib) 5A Reactive energy(Varh) Class 2
Maximum rated current (Imax) 45A Active energy (Wh) Class 1
45A direct load Operational current range 0.4% Ib-Imax
1 module 17.5mm wide Over current withstand 30 Imax for 0.01s Modbus
Multi-measurement: kWh,W, V, A, PF, Hz, dmd.etc. Operational frequency range 50 / 60Hz
Bus type RS485(semi-duplex)
Internal power consumption ≤ 2W/10VA
Bi-directional measurement Protocol Modbus RTU
Pulse output 1000imp/kWh
2 Pulse outputs MID Display LCD with backlight
Baud rate
Address range
1200/2400/4800/9600bps/19200(optional)bps
1-247
RS485 Modbus or M-bus communication Max reading 99999.9 kWh/kVarh
Max. Bus loading 64pcs
Communication distance 1000M
Performance criteria Parity EVEN/ODD/NONE
Operating humidity ≤ 90% Data bit 8
Storage humidity ≤ 95% Stop bit 1
Operating temperature -25°C - +55°C
Storage temperature -40°C - +70°C
23°C± 2°C
M-bus
Reference temperature
Bus type M-bus
International standard IEC 62053-21 / EN50470-1/3
Protocol EN13757-3
Accuracy class Class1/Class B
Baud rate 600/1200/2400/4800/9600/19200(optional)bps
Installation category CAT II
Introduction Mechanical environment M1
Parity NONE/EVEN/ODD
Stop bits 1 or 2
Electromagnetic environment E2
SDM120-45A series are advanced single phase energy monitoring solution with built-in configuration push button and LCD data displaying, Primary Address 1 to 250
Degree of pollution 2
particularly indicated for energy and other parameters metering and for cost allocation. Housing for DIN-rail mounting, IP51 protection Secondary Address 00 00 00 01 to 99 99 99 99
P rotection against penetration of dust and water IP51(indoor)
degree, direct connection up to Max 45A. Moreover the meter can be provided with a pulses output proportional to the active energy being
Insulating encased meter of protective class II
measured and a RS485 output/ M-bus output port for remote monitoring. It is an ideal choice as a sub-meter for AMR system or SCADA system.
Altitude up to 2000m Pulse output
Electrostatic discharges 8kV contact / 15kV air gap Pulse outputs 2
This series has been assessed and certified as meeting the requirements of EU Directive 2014/32/EU. Electromagnetic HF fields IEC 61000-4-3 Pulse output type Passive
The EU Type Examination Certificate Number is 0120/SGS0141. Electrical fast transients 4kV Configurable
Pulse Output 1
Surge 4kV Pulse width 200/100(default)/60ms
Radiated & conducted emissions EN 55022 Pulse output 2 1000imp/kWh
SDM120 —M—1—1
17
.5
m
m
MBUS 1 MBUS 2
SDM120MB
P: Multi-parameters, 2 Pulse outputs
M:Multi-parameters, 2 Pulse outputs + RS485 Modbus RTU
MB: Multi-parameters, 2 Pulse outputs + M-Bus Communication
G B A
SDM120M
62mm
1: 110V/120V AC
2: 220V/230V AC
35mm
1: MID SDM120P
2: Non-MID Height 119mm
Width 17.5mm
Depth 62mm
Specification Accuracy
Nominal voltage(Un) 120V or 230V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM120CT Modbus / Mbus / Pulse - AC voltage withstand
- Impulse voltage withstand
4KV for 1 minute
6KV-1.2µS
Active power , Apparent power ±1% of range maximum
Reactive power ±1% of range maximum
SINGLE PHASE MULTI-FUNCTION ENERGY METER
Primary current 5~9999A Reactive energy(Varh) Class 2
Secondary input 1A/5A or 100mV Active energy (Wh) Class 1
CT operated Over current withstand 20 Imax for 0.01s
1 module 17.5mm wide Operational frequency range 50 or 60Hz Modbus
Internal power consumption ≤ 2W/10VA
Multi-measurement: kWh,W, V, A, PF, Hz, dmd. etc. Bus type RS485(semi-duplex)
Pulse output 1 configurable
Bi-directional measurement Protocol Modbus RTU
Pulse output 2 1000imp/kWh
2 Pulse outputs MID Display LCD with backlight
Baud rate
Address range
1200/2400/4800/9600bps/19200( optional)bps
1-247
RS485 Modbus or M-bus communication Max reading 999999 kWh/kVarh
Max. Bus loading 64pcs
Communication distance 1000M
Performance criteria Parity EVEN/ODD/NONE
Operating humidity ≤ 90% Data bit 8
Storage humidity ≤ 95% Stop bit 1
Operating temperature -25°C - +55°C
Storage temperature -40°C - +70°C
23°C± 2°C
M-bus
Reference temperature
Bus type M-bus
International standard IEC 62053-21 / EN50470-1/3
Protocol EN13757-3
Accuracy class Class1/Class B
Baud rate 600/1200/2400/4800/9600/19200(optional)bps
Installation category CAT II
Introduction Mechanical environment M1
Parity NONE/EVEN/ODD
Stop bits 1 or 2
Electromagnetic environment E2
SDM120 CT series is CT operated type single phase multi-function energy meter. The meter is compactly designed in one module din rail Primary Address 1 to 250
enclosure. LCD display is provided to show the energy and other important electric parameters measured. Moreover the meter can Degree of pollution 2
Secondary Address 00 00 00 01 to 99 99 99 99
provide with pulse outputs proportional to the energy being measured and a RS485 output/ M-bus output port for remote monitoring. CT P rotection against penetration of dust and water IP51(indoor)
ratio can be set, which enables this meter to measure big current load. II
Insulating encased meter of protective class
Aititude up to 2000m Pulse output
This series has been assessed and certified as meeting the requirements of EU Directive 2014/32/EU. Electrostatic discharges 8kV contact / 15kV air gap Pulse outputs 2
The EU Type Examination Certificate Number is 0120/SGS0141. IEC 61000-4-3
Electromagnetic HF fields Pulse output type Passive
Electrical fast transients 4kV Pulse Output 1 Configurable
Surge 4kV Pulse width 200/100(default)/60ms
Radiated & conducted emissions EN 55022 Pulse output 2 1000imp/kWh
SDM120—CT—M—1—1
G B A
P: Multi-parameters, 2 Pulse outputs SDM120CTM
M:Multi-parameters, 2 Pulse outputs + RS485 Modbus RTU
MB: Multi-parameters, 2 Pulse outputs + M-Bus Communication
MBUS 1 MBUS 2
SDM120CT-MB
62mm
1: 110V/120V AC
2: 220V/230V AC
35mm
1: MID SDM120CTP
2: Non-MID
S2
P1
Height 119mm
Width 17.5mm
Depth 62mm
Specification Accuracy
Nominal voltage(Un) 230V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
2 1 GND B A
SDM220 —M—1—1
4 5 6 7 8 9 PULSE OUTPUT RS485 PORT SDM220-Modbus
P : Multi-parameters,2 Pulse outputs SDM220-MT 45m
m
Std: kWh,2 Pulse outputs, Modbus 4 5 6 7 8 9 SDM220-STD
M: Multi-parameters,2 Pulse outputs, Modbus
MB: Multi-parameters,2 Pulse outputs, M-Bus
MT:: Multi-parameters,2 Pulse outputs,4 Tariffs, Modbus 2 1
47mm
PULSE OUTPUT
1:110/120V SDM220-Pulse
62 mm
2:220/230V 4 5 6 7 8 9
1: MID
2 1 BUS1 BUS2
2: Non-MID
mm
1 2 3 35
PULSE OUTPUT MBUS PORT mm
90
m
6m
SDM220-Mbus
4 5 6 7 8 9
3
100A
L IN L OUT Height 90mm
N Width 36mm
Depth 62mm
Specification Accuracy
Nominal voltage(Un) 120V or 230V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM 230 Modbus / Mbus / 2T / Std / Pulse - AC voltage withstand 4KV for 1 minute Active power , Apparent power ±1% of range maximum
- Impulse voltage withstand 6KV-1.2µS Reactive power ±1% of range maximum
SINGLE PHASE MULTI-FUNCTION ENERGY METER
Basic current (Ib) 10A Reactive energy(Varh) Class 2
Maximum rated current (Imax) 100A Active energy (Wh) Class 1/Class0.5S
100A direct load Operational current range 0.4% Ib-Imax
2 Module 36mm wide Over current withstand 30 Imax for 0.01s Modbus
Multi-measurement:kWh,kVarh,W,Var,VA,PF,Hz,dmd,V,A,etc. Operational frequency range 50 or 60Hz
Bus type RS485(semi-duplex)
Internal power consumption ≤ 2W/10VA
Bi-directional measurement Protocol Modbus RTU
Pulse output 1 1000imp/kWh
Baud rate 1200/2400/4800/9600bps/19200(optional)
2 Pulse outputs Pulse output 2 1000imp/kWh
Address range 1-247
RS485 Modbus or M-bus communication Max reading 999999.9 kWh/kVarh
Max. Bus loading 64pcs
2 Tariffs available(dual power source) MID Communication distance 1000M
Performance criteria Parity EVEN/ODD/NONE
Operating humidity ≤ 90% Data bit 8
Storage humidity ≤ 95% Stop bit 1
Operating temperature -25°C - +55°C
Storage temperature -40°C - +70°C
23°C± 2°C
M-bus
Reference temperature
Bus type M-bus
International standard IEC 62053-21 / IEC620532-22 / EN50470-1/3
Protocol EN13757-3
Accuracy class Class1/Class0.5S/Class B
Baud rate 600/1200/2400/4800/9600/19200(optional)
Installation category CAT II
Introduction Mechanical environment M1
Parity NONE/EVEN/ODD
Stop bits 1 or 2
Electromagnetic environment E2
SDM230 series is an advanced digital single phase multi-function energy meter, which measures up to 100A direct load. The unit measures Primary Address 1 to 250
Degree of pollution 2
active energy, reactive energy, current, voltage, power, power factor, frequency, demand, etc. Bi-directional measurement makes this unit Secondary Address 00 00 00 01 to 99 99 99 99
P rotection against penetration of dust and water IP51(indoor)
an ideal choice for Solar PV measurement. A remote communication port is provided, RS485 Modbus RTU or M-bus EN13757-3 and
Insulating encased meter of protective class II
communication parameters are password protected in setup mode. User can check data and set up the meter via the buttons on the front
panel. SDM230-2T can measure energy from two different power supplies. Electrostatic discharges 8kV contact / 15kV air gap Pulse Output
Electromagnetic HF fields IEC 61000-4-3 Pulse outputs 2
This Series has been assessed and certified as meeting the requirements of EU Directive 2014/32/EU. Electrical fast transients 4kV Pulse output type Passive
The EU Type Examination Certificate Number is 0120/SGS0206. Surge 4kV Pulse Output 1 Configurable
Radiated & conducted emissions EN 55022 Pulse width 200/100(default)/60ms
Pulse output 2 1000imp/kWh
230V/2T 45mm
63mm
1:110/120V
A B GND 1+ COM 2+
SDM230Modbus
2:220/230V
5 6 7 8 9 10
1: MID SDM230Mbus
2: Non-MID Mbus1 Mbus2 1+ COM 2+ 36
5 6 7 8 9 10
m
m 35mm
99mm
B:Class 1 5 6 7 8 9 10
3 4 Height 99mm
Width 36mm
N-in N-out
Depth 63mm
Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM530 Modbus / Mbus / MT / DO - AC voltage withstand 4KV for 1 minute Active power , Apparent power ±1% of range maximum
- Impulse voltage withstand 6KV-1.2µS Reactive power ±1% of range maximum
THREE PHASE FOUR WIRE MULTI-FUNCTION ENERGY METER
Basic current (Ib) 10A Reactive energy(Varh) Class 2
Maximum rated current (Imax) 100A Active energy (Wh) Class 1/Class0.5s
100A direct load Operational current range 0.4% Ib-Imax
7 Module wide Over current withstand 30 Imax for 0.01s
Modbus
Operational frequency range 50 or 60Hz
Multi-measurement:kWh,kVarh,W,Var,VA,PF,Hz,dmd,V,A,etc. Bus type RS485(semi-duplex)
Power consumption per phase ≤ 2W/10VA
Bi-directional measurement Protocol Modbus RTU
Display LCD
Baud rate 1200/2400/4800/9600bps
2 Pulse outputs Max reading 999999.99 kWh/kVarh
Address range 1-247
RS485 Modbus or M-bus communication Performance criteria Max. Bus loading 64pcs
Multi-tariffs available(RTC) Operating humidity ≤ 90% Communication distance 1000M
Storage humidity ≤ 95% Parity EVEN/ODD/NONE
Operating temperature -25°C - +55°C Data bit 8
Storage temperature -40°C - +70°C Stop bit 1
Reference temperature 23°C± 2°C
International standard IEC 62053-21 / IEC 62053-22 / EN50470-1/3
M-bus
Accuracy class Class1/Class0.5S/Class B
Bus type M-bus
Installation category CAT III
Protocol EN13757-3
Mechanical environment M1
Baud rate 600/1200/2400/4800/9600bps
Electromagnetic environment E2
Introduction Degree of pollution 2
Parity NONE/EVEN/ODD
Stop bits 1 or 2
The SDM530 100A series measure and display the characteristics of three phase four wires(3p4w) supplies, including voltage, frequency, P rotection against penetration of dust and water IP51(indoor)
Primary Address 1 to 250
current, power, active and reactive energy, imported or exported. Energy is measured in terms of kWh, kVArh. Maximum demand current Insulating encased meter of protective class II
Secondary Address 00 00 00 01 to 99 99 99 99
can be measuredover preset periods of up to 60 minutes. In order to measure energy, the unit requires voltage and current inputs in order Electrostatic discharges 8kV contact / 15kV air gap
to the supply required to power the product. Electromagnetic HF fields IEC 61000-4-3
Electrical fast transients 4kV Pulse Output
SDM530 100A series support max.100A direct connection, save the cost and avoid the trouble to connect external CTs, giving the unit a cost-effective Pulse outputs 2
and easy operation. Built-in interfaces provide pulse and RS485 Modbus RTU outputs/ Mbus Port. All the configuration are password protected. Pulse output type Passive
Multi-tariff
time clock accuracy ﹤1s/day Pulse Output 1 Configurable
Tariff 4 Pulse width 200/100(default)/60ms
Time segments 10 Pulse output 2 400imp/kWh
Do 1 Do 2
SDM530—M—4—4—C 18 17
24 23 22 21 20 19
65mm
49mm
1: 3x127/220V
2: 3x230/400V SDM530Modbus/MT
1: Single tariff 1 2 3 4 5 6 7
BUS1 BUS2 35
mm
4: 4 Tariffs 2 1
10
0m
m
mm
125
L1
24 23 22 21 20 19
B:Class 1 L2
C: Class 0.5s SDM530Mbus L3
N Height 100mm
Width 125mm
Depth 65mm
Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
Do 1 Do 2
SDM530CT—M—4—4—C 18 17
L1 L2 L3 N
24 23 22 21 20 19
65mm
49mm
1: 127/220V
2: 230/400V SDM530CT-Modbus/MT
1: Single tariff
1 2 3 4 5 6 7
BUS1 BUS2 35
2 1 mm
4: 4 Tariffs 10
0m
m
mm
125
L1 S1
24 23 22 21 20 19 P1
S1
B:Class 1 L2
C: Class 0.5s
SDM530CT-Mbus P1
S1
L3 P1
N
Height 100mm
Width 125mm
Depth 65mm
Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
Works with 3P4W / 3P3W / 1P2W Over current withstand 30 Imax for 0.01s
Modbus
Operational frequency range 50 or 60Hz
4 Module wide Bus type RS485(semi-duplex)
Power consumption per phase ≤ 2W/10VA
Protocol Modbus RTU
Multi-measurement:kWh,kVarh,W,Var,VA,PF,Hz,dmd,V,A,THD,etc. Display LCD
Baud rate 2400/4800/9600/19200/38400bps
Bi-directional measurement Max reading 999999.99 kWh/kVarh
Address range 1-247
2 Pulse outputs Max. Bus loading 64pcs
Performance criteria
RS485 Modbus or M-bus communication ≤ 90% Communication distance 1000M
Operating humidity
Multi-tariffs available(RTC) MID Storage humidity ≤ 95% Parity EVEN/ODD/NONE
1: Single tariff
2: 2 Tariffs
4: 4 Tariffs
5 6 7 8 5 6 7 8 5 6 7 8
1: MID 72 35m
m
m mm
2: Non-MID m 100
L1 L2 L3 N L1 L3 L2 L1 N
B:Class 1
C: Class 0.5s
D: Class 0.2s SDM630Modbus SDM630-Pulse SDM630Mbus Height 100mm
SDM630-Standard Width 72mm
SDM630-MT
Depth 66mm
SDM630-2T
Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 60%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM630 CT Series have been assessed and certified as meeting the requirements of EU Directive 2014/32/EU. The instrument traceable
number is 0120/SGS0142
Wiring diagram Dimensions
SDM630MCT
SDM630MCT-MV
SDM630MCT—5—J—2—4—1—C
1: 100mA
2: 100mV
SDM630MCT-2T
3: 333mV
M:RS485Modbus
5: 1A & 5A MB: M-Bus
L: LoRaMESH/LoRaWAN
W: Wifi
1: Self-power supply
2: Aux. AC power supply
SDM630MCT-Mbus Height 94.5mm
3: Aux. DC power supply 1: Single tariff Width 72mm
2: 2 Tariffs Depth 65mm
4: 4 Tariffs
1: MID
2: non-MID B:Class 1
C: Class 0.5s
D: Class 0.2s
Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 60%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
333mV CT 333mV CT
RJ-12 RJ-12
ESCT-SC ESCT-SC
ESCT-RJ SDM630MCT-2L
ESCT-RJ
S1
P1
S1
P1
L2
P1 P1
RJ12 socket for S1 S1
L3
fast connection and to P1 P1
L1
L2 1 2 3 4
L3 Height 94.5mm
N MEASURED VOLTAGE
Width 72mm
The example shows a wiring in 3p4w network. 3 PHASE 4 WIRE Depth 65mm
Plug-in terminals for voltage inputs.
Self power supply from L1.
Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM630-2C - AC voltage withstand 4KV for 1 minute
6KV-1.2µS
Active power , Apparent power ±1% of range maximum
- Impulse voltage withstand Reactive power ±1% of range maximum
DUAL LOAD MULTI-FUNCTION ENERGY METER Rated current (Ir) 5A or 333mV CT input Reactive energy(Varh) Class 2
Operational current range 0.4% Ib-Imax Active energy (Wh) Class 1/ Class 0.5S
Over current withstand 20 Imax for 0.01s
2 Meters in 1
Operational frequency range 50 or 60Hz
Easy and error free connection ≤ 2W/10VA Modbus
Power consumption per phase
5A / 333mV CT input Pulse output Configurable Bus type RS485(semi-duplex)
Multi-parameter measured Display LCD Protocol Modbus RTU
Max reading 9999999.9 kWh/kVarh Baud rate 2400/4800/9600/19200/38400 bps
RS485 Modbus RTU
Address range 1-247
2 Pulse outputs
Max. Bus loading 64pcs
Performance criteria Communication distance 1000M
Operating humidity ≤ 90% Parity EVEN/ODD/NONE
Storage humidity ≤ 95% Data bit 8
Operating temperature -25°C - +55°C Stop bit 1
Storage temperature -40°C - +70°C
Reference temperature 23°C± 2°C
International standard IEC 62053-21 / IEC 62053-22 / EN50470-1/3 Pulse Output
Accuracy class Class1/Class0.5S/Class B Pulse outputs 2
Installation category CAT III Pulse output type Passive
Introduction Mechanical environment M1 Pulse Output 1 C1 Configurable
Electromagnetic environment E2 Pulse output 2 C2 Configurable
The SDM630-2C is a dual load three phase 4 wire multi-function energy meter for measuring energy consumption in split load applica- Degree of pollution 2 Pulse width 200/100(default)/60ms
tions such as Power and lighting loads. The meter measures 2 three phase circuits separately and display the parameters including P rotection against penetration of dust and water IP51(indoor)
Insulating encased meter of protective class II
voltage, current, power, power factor, frequency, demand, active energy, reactive energy etc.
Electrostatic discharges 8kV contact / 15kV air gap
Electromagnetic HF fields IEC 61000-4-3
The meter connects with 3-in-1 CT via wiring looms for plug-in connection. It is a cost-effective and space saving solution for all new
Electrical fast transients 4kV
power and lighting, or dual load, distribution and panel boards. ESCT-SC series current transformer provides a range of CT with primary
Surge 4kV
current up to 630A.
Radiated & conducted emissions EN 55022
Circuit 2
Current connection cable between CT3
Circuit 1
CT3
65mm
CT2
CT1
L32 L31 L22 L21 L12 L11 L32 L31 L22 L21 L12 L11
m
Voltage input - --- 1 - --- 2 - RS485 10 35m
--
- --
-
5m
ESCT-SC N L3 L2 L1 - - - B A m m
-
GND
92m
1A fast blow fuses
L1 N L3 L2 L1 Height 92mm
Voltage connection cable between L2
L3 SDM630MCT-2C, SDM630MV-2C Width 105mm
network and the meter N Depth 65mm
Operational current range 0.4% Ib-Imax Over current withstand 30 Imax for 0.01s
Over current withstand 30 Imax for 0.01s Operational frequency range 50 or 60Hz
Wiring diagrams Internal power consumption ≤ 2W/10VA
Operational frequency range 50 / 60Hz Wiring diagrams
Internal power consumption ≤ 2W/10VA Pulse output 1000imp/kWh
Pulse output 1000imp/kWh Max reading 999999.9 kWh(SDM230A) 100A
L-in L-out
Performance criteria 1 2
63mm
Radiated & conducted emissions EN 55022
Radiated & conducted emissions EN 55022
62mm
Description
Description Buttons
Specification Specification
Model SDM 230DR / SDM230BI Model SDM320Y/320D
Display LCD with Backlit Nominal voltage(Un) 230V or 120V ac SDM320 —D—1—1
SDM230 —DR—1—1
Nominal voltage(Un) 120V or 230V ac Operational voltage 80%~120% of Un
Operational voltage 80%~120% of Un Insulation capabilities Y: Analog Register
DR: kWh + kW, Resettable Energy, Pulse output - AC voltage withstand 4KV for 1 minute D: LCD Display
Insulation capabilities BI: Import/export/total kWh and Power,
- AC voltage withstand 4KV for 1 minute resettable Energy,Pulse putput - Impulse voltage withstand 6KV-1.2µS
1: Without Backlight
- Impulse voltage withstand 6KV-1.2µS Basic current (Ib) 10A
1:110/120V 2: With Backlight
Basic current (Ib) 10A 2:220/230V Maximum rated current (Imax) 80A
Maximum rated current (Imax) 100A Operational current range 0.4% Ib-Imax 1: 110V/120V AC
1: MID
Operational current range 0.4% Ib-Imax Over current withstand 30 Imax for 0.01s 2: 220V/230V AC
2: Non-MID
Over current withstand 30 Imax for 0.01s Operational frequency range 50 or 60Hz
Operational frequency range 50 or 60Hz Internal power consumption ≤ 2W/10VA
Internal power consumption ≤ 2W/10VA Pulse output 1000imp/kWh Wiring diagrams
Pulse output 1 1000imp/kWh Display LCD
Pulse output 2 1000imp/kWh Max reading 99999.99 kWh
Max reading 999999.9 kWh
Wiring diagrams Terminals 5 & 6: Pulse output
Performance criteria
Performance criteria 100A Operating humidity ≤90%
L-in L-out
M1
5 6 7 8 9 10
Electromagnetic environment E2
Mechanical environment Dimensions
Electromagnetic environment E2 Degree of pollution 2
Electrostatic discharges 8kV contact / 15kV air gap Electrostatic discharges 8kV contact / 15kV air gap
MECHANICS MECHANICS
63mm
Din rail dimensions 99x36x63 (HxHxD) DIN 43880 Din rail dimensions 76x100x66 (WxHxD) DIN 43880
Mounting DIN rail 35mm Mounting DIN rail 35mm Height 100mm
Sealing IP51 (indoor) Sealing IP51 (indoor) Width 72mm
Material self-extinguishing UL94V-0 Depth 66mm
Material self-extinguishing UL94V-0 36
m
m 35mm
99mm
Description Description
Specification Specification
Model SDM320E Model SDM530D / SDM530D-2T
Nominal voltage(Un)
SDM320 —E—1—1 Nominal voltage(Un) 3x230/400 V ac or 3x127/220 V ac SDM530 —D—1—1
110/220 V ac or 220/380V ac
Operational voltage 80%~120% of Un Operational voltage 80%~120% of Un
Insulation capabilities E: Single Phase 3 Wire Insulation capabilities D: LCD Display, kWh
- AC voltage withstand 4KV for 1 minute - AC voltage withstand 4KV for 1 minute D-2T: LCD Display, kWh, Double Tariff
1: Without Backlight
- Impulse voltage withstand 6KV-1.2µS - Impulse voltage withstand 6KV-1.2µS
2: With Backlight
Basic current (Ib) 10A Basic current (Ib) 10A 1: Without Backlight
1: 110V/220V AC Maximum rated current (Imax) 100A 2: With Backlight
Maximum rated current (Imax) 100A
2: 220V/380V AC
Operational current range 0.4% Ib-Imax Operational current range 0.4% Ib-Imax
1: 127V/220V
Over current withstand 30 Imax for 0.01s Over current withstand 30 Imax for 0.01s
2: 230V/400V
Operational frequency range 50 or 60Hz Wiring diagrams Operational frequency range 50 or 60Hz
Internal power consumption ≤ 2W/10VA Power consumption per phase ≤ 2W/10VA
Pulse output 1600imp/kWh Pulse output 800imp/kWh
LCD
Wiring diagrams
Display LCD Display
N-in N-out
8 7 6 5
230V/2T
Performance criteria 11 10 9 8
65mm
49mm
Mechanics
Mechanics 35
Din rail dimensions 76x100x66 (WxHxD) DIN 43880 10
0m
mm
m
Mounting DIN rail 35mm Din rail dimensions 100x125x65 (HxWxD) DIN 43880 125
mm
66mm
Sealing IP51 (indoor) Height 100mm
Sealing IP51 (indoor) 5
6
7
Width 72mm
Material self-extinguishing UL94V-0 Material self-extinguishing UL94V-0 72
8
m Depth 66mm
m 35m
m mm
100
CT operated CT operated
4 Module wide 4 Module wide
Measures active energy(kWh)+ power(W) Measures active energy(kWh)+ power(W)
SDM72CT-D/DR/BI Bi-directional measurement
SDM72CT-M Bi-directional measurement
Resettable energy THREE PHASE FOUR WIRE ENERGY METER Resettable energy
THREE PHASE FOUR WIRE ENERGY METER
Pulse output RS485+Pulse output
Mechanics Dimensions
Mechanics
Din rail dimensions 72x94.5x65 (WxHxD) DIN 43880 Din rail dimensions 100x125x65 (WxHxD) DIN 43880
Mounting DIN rail 35mm Mounting DIN rail 35mm Height 94.5mm
Material self-extinguishing UL94V-0 Width 72mm
Material self-extinguishing UL94V-0
Height 94.5mm Depth 65mm
Width 72mm
Depth 65mm
Input Environment
Nominal input voltage 57.7-276V AC ( L-N ) 173-480V AC( L-L) Operating temperature -25˚C to +55˚C
Max. continuous input overload voltage 120% of nominal Storage temperature -40˚C to +70˚C
Smart X96 A Series Max. short duration input voltage
Nominal input voltage burden
2 x nominal voltage for 1 second
< 0.2VA per phase
Relative humidity
Shock
0 to 95%, non-condensing
30g in 3 planes
SMART ENERGY ANALYZER FOR SINGLE AND THREE PHASE SYSTEMS Nominal input current 100mA / 5A Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g
Nom. Input current burden < 0.1 VA Dielectric Voltage 4kV between voltage and current to earth
Measures kWh, kVarh, kW, kVar, kVa, P, F, PF, Hz, dmd, V, A, etc. Max. continuous input overload current 120% of nominal Altitude 3000m
Bi-directional measurement Imp & Exp Max. short duration input current 20 x nominal current for 10ms Warm-up 1 minute
Energy information of each phase
Total harmonic distortion of voltage and current Power supply Outputs
2nd~63rd individual harmonic distortion Operating range Self powered (from any of the three phases) Pulse Width 60 / 100 / 200 ms
RS485 Modbus RTU & 2 pulse outputs Supply burden ≤ 2W / 10 VA Pulse rate of S0 1 0.01 / 0.1 / 1 / 10 / 100 /1000kWh/kVArh
Bar graph for power indication Pulsed output of S0 2 (non-configurable) 3200IMP/kWh
Three phase self-power supply Accuracy Communications Modbus RTU (RS485)
Voltage (V) 0.5% of range maximum Type 2-wire half duplex
Backlit LCD display for full viewing angles
MID Current (A) 0.5% of range maximum Baud rate 2400,4800, 9600, 19200, 38400bps
Accuracy class 0.2s /0.5s /1.0
Frequency (Hz) 0.2% of mid-frequency Address 1 to 247
Plug-in play solution
Power factor (PF) 1% of unity (0.01)
Active power (W) 1.0% of range maximum
Reactive power (VAr) 1.0% of range maximum Enclosure
Apparent power (VA) 1.0% of range maximum Enclosure Style DIN 96 panel mount
Active energy (kWh) Class 0.5S IEC62053-22 Dimensions 96x96x70mm
Introduction Class 1.0 IEC62053-21 Panel cut-out 92x92mm
Reactive energy (kVArh) 1.0% of range maximum to IEC 62053-24 Panel thickness 1-3 mm
The Smart X96 digital smart meter from Eastron is an ideal solution for the measurement and display of all important electrical parameters THD 2% to 63rd harmonic Protection rating IP51 (Indoor)
including harmonic distortion of total and individual, up to 63rd. The meter uses a high definition screen with programmable backlight for Material UL 94-VO
high visibility in dark area and from all viewing angles. New sector icons shows the percentage of the power load on 3 phases. Modbus Weight 420 g
Measured Range
RS485 RTU and 2 pulse outputs are equipped as standard. Cable size 0.05mm-4mm stranded wire
Voltage (V) 15 – 120% of nominal (Min 100V -self powered)
Terminals Voltage: Shrouded screw-clamp.
Current (A) 5 – 120% of nominal
The Smart X96 and 3-in-1 current transformers provide a simple and fast installation solutions. With pre-cut wiring looms, the meters and
Frequency (Hz) 45– 66 Hz
CTs can beeasily connected. This solution reduces lots of wiring and installation time, and saves wrong wiring troubles.
Power (W, VAr, VA) 5 – 120% of nominal (bi-directional)
Energy 8digit, upto 9999999.9 kWh
Power factor 4 quadrants
THD Up to 63rd harmonic
2P1+
CO
M+
↑
P2+ I1
↓
↑
I2
↓
SMART X96
↑
I3
↓
ESCT-SC
ESCT-RJ ESCT-SC
32
meters
96mm
Smart X96
92mm
SMART X96-1 SMART X96-5
m
96m
70 mm
L1
L2
L3 Daisy connection for power supply. Height 96mm
N Max. 32pcs meters can be connected. Width 96mm
The example shows a wiring in 3p4w network. Plug-in type voltage terminals. 1~3mm Depth 70mm
the meter can also work in 3p3w and 1p2w system.
Input Environment
Nominal input voltage 57.7-276V AC ( L-N ) 173-480V AC( L-L) Operating temperature -25˚C to +55˚C
Max. continuous input overload voltage 120% of nominal Storage temperature -40˚C to +70˚C
Smart X96 F~J Series Max. short duration input voltage
Nominal input voltage burden
2 x nominal voltage for 1 second
< 0.2VA per phase
Relative humidity
Shock
0 to 95%, non-condensing
30g in 3 planes
SMART ENERGY ANALYZER FOR SINGLE AND THREE PHASE SYSTEMS Nominal input current 5A Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g
Nom. Input current burden < 0.1 VA Dielectric Voltage 4kV between voltage and current to earth
Max. continuous input overload current 120% of nominal Altitude 3000m
Multi-parameters measurements
Max. short duration input current 20 x nominal current for 1 second Warm-up 1 minute
Up to 63 rd THD and IHD
RS485 Modbus RTU
Ethernet TCP gateway Auxiliary Power supply Modbus
Operating range 65-480V AC/80-660V DC Bus type RS485(semi-duplex)
Multi-tariffs
Power consumption < 2W/10VA Protocol Modbus RTU/Modbus TCP
Digital input/output
Baud rate 2400/4800/9600/19200/38400bps
Accuracy class 0.2s
Accuracy Address range 1-247
Bar graph for power indication
Voltage (V) 0.5% of range maximum Communication distance 1000M
Backlit LCD display for full viewing angles Current (A) 0.5% of range maximum Parity EVEN/ODD/NONE
Push-in installation and plug-in connection Frequency (Hz) 0.2% of mid-frequency Data bit 8
Power factor (PF) 1% of unity (0.01) Stop bit 1
Active power (W) 1.0% of range maximum Digital Input 4
Reactive power (VAr) 1.0% of range maximum Digital Output 2
Apparent power (VA) 1.0% of range maximum
Active energy (kWh) Class 0.5S IEC62053-22
Introduction Class 1.0 IEC62053-21 Enclosure
Reactive energy (kVArh) 1.0% of range maximum to IEC 62053-24 Enclosure Style DIN 96 panel mount
The multifunction energy analyzer SMART X96 F~J series is a top new-generation intelligent panel meter with built-in interfaces provides
THD 2% to 63rd harmonic Dimensions 96x96x70 mm
RS485 Modbus RTU and Ethernet TCP/IP communication. Digital input and outputs are provided for external signal counting and external
Panel cut-out 92x92mm
device control. 30 type's parameters can be set for alarm. This series is widely used not only in the electricity transmission and power
Panel thickness 1-3 mm
distribution system, but also in the power consumption measurement and analysis in LV/MV Intelligent power grid. The Unit can be used Measured Range
Protection rating IP51 (Indoor)
as a gateway for Modbus RTU/TCP. Voltage (V) 15 – 120% of nominal (Min 100V -self powered)
Material UL 94-VO
Current (A) 5 – 120% of nominal
Weight 420 g
SMART X96 measures and displays the characteristics of 1p2w, 3p4w and 3p3w supplies, including voltage, frequency, current, power and Frequency (Hz) 45– 66 Hz
Cable size 0.05mm-4mm stranded wire
active and reactive energy, imported or exported, Harmonic, Power factor, Max. Demand etc. Energy is measured in terms of kWh, kVArh Power (W, VAr, VA) 5 – 120% of nominal (bi-directional)
Terminals Voltage: Shrouded screw-clamp.
and kVAh. Maximum demand current can be measured over preset periods of up to 60 minutes. The Smart X96 can be configured to work Energy 8digits, up to 9999999.9 kWh
with a wide range of CTs and PTs, giving the unit a wide range of operation. Power factor 4 quadrants
THD Up to 63rd harmonic
Installation Dimensions
Smart X96 —5—J—2—4—C
1: 100mA
2: 100mV
3: 333mV SMA RT X96
92mm
2: Aux. AC power supply
3: Aux. DC power supply
1: Single tariff
2: 2 Tariffs
4: 4 Tariffs 96m
m mm
70
B: Class 1 92mm
C: Class 0.5s
D: Class 0.2s
Height 96mm
Width 96mm
1~3mm Depth 70mm
Input Environment
Nominal input voltage 57.7 – 276V AC L-N (100-480V L-L) Operating temperature -25˚C to +55˚C
Max. continuous input overload voltage 120% of nominal Storage temperature -40˚C to +70˚C
Smart X835 Series Max. short duration input voltage
Nominal input voltage burden
2 x nominal voltage for 1 second
< 0.2VA per phase
Relative humidity
Shock
0 to 95%, non-condensing
30g in 3 planes
SMART ENERGY ANALYZER FOR SINGLE AND THREE PHASE SYSTEMS Nominal input current 5A Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g
Nom. Input current burden < 0.1 VA Dielectric Voltage 4kV between voltage and current to earth
Multi-parameters measured Max. continuous input overload current 120% of nominal Altitude 3000m
Max. short duration input current 20 x nominal current for 1 second Warm-up 1 minute
2nd~63rd individual harmonic distortion
Auxiliary 85-276V AC 50/60Hz or 120-380V DC
Support 3p4w, 3p3w, 1p2w system Supply burden < 2W /10 VA
CT and PT connected Outputs
Pulse Width 60 / 100 / 200 ms
Multi tariffs available
Accuracy Pulse rate of S0 1 0.01 / 0.1 / 1 / 10 / 100 kWh/kVArh
Digital output/ digital input/ analog output / pulse output Voltage (V) 0.5% of range maximum Pulsed output of S0 2 (non-configurable) 3200IMP/kWh
RS485 Modbus communication Current (A) 0.5% of range maximum Communications Modbus RTU (RS485)
Frequency (Hz) 0.2% of mid-frequency Type 2-wire half duplex
Crest factor & key factor
Power factor (PF) 1% of unity (0.01) Baud rate 2400,4800, 9600, 19200, 38400bps
Active power (W) 1.0% of range maximum Address 1 to 247
Reactive power (VAr) 1.0% of range maximum
Apparent power (VA) 1.0% of range maximum
Active energy (kWh) 1.0% of range maximum to IEC 62053-21 Enclosure
1.0% of range maximum to IEC 62053-24 Enclosure Style DIN 96 panel mount
Reactive energy (kVArh)
2% to 63rd harmonic Dimensions 96x96x72 mm
THD
Panel cut-out 92x92mm
Smart X835DIO
N
F
V1 V2 V3 VN ( I1 ) ( I2 ) ( I3 )
DIO: 2 Digital Inputs , 2 Digital Outputs, RS485 Modbus
AO: 2 Analog Outputs , RS485Modbus, 2 Pulse outputs
L1 Smart X835P/B/AO
1: Single Tariff N
Aux. Power Supply Analog output Pulse
4: Multi Tariffs 1-phase 2-wire L N G Ao1 Ao2 COM + -
2
+ -
1
RS-485
A+ B-
m
Height 96mm
m
72
F
V1 V2 V3 VN ( I1 ) ( I2 ) ( I3 ) Width 96mm
2: Aux. AC power supply Depth 72mm
3: Aux. DC power supply
L1
B:Class 1 L2
C: Class 0.5s L3
3-phase 3-wire
Input Environment
Nominal input voltage 57.7 – 276V AC L-N (100-480V L-L) Operating temperature -25˚C to +55˚C
Max. continuous input overload voltage 120% of nominal Storage temperature -40˚C to +70˚C
The multifunction energy analyzer SMART X72 series is an intelligent panel meter, used not only in the electricity transmission and power
distribution system, but also in the power consumption measurement and analysis in high voltage intelligent power grid.
Measured Range
The unit measures and displays the characteristics of single phase two wires, three phase three wires and three phase four wires supplies, Voltage (V) 15 – 120% of nominal (Min 100V -self powered)
including voltage, frequency, current, power , active and reactive energy, imported or exported, Harmonic, Power factor, Max. Demand, Current (A) 5 – 120% of nominal
etc. Energy is measured in terms of kWh, kVArh. Maximum demand current can be measured over preset periods of up to 60minutes. In Frequency (Hz) 45 – 66 Hz
order to measure energy, the unit requires voltage and current inputs in addition to the supply required to power the product. The requisite
Power (W, VAr, VA) 5 – 120% of nominal (bi-directional)
current input(s) are obtained via current transformers The Smart X72 can be configured to work with a wide range of CTs, giving the unit a
Energy 8 digits, up to 9999999.9 kWh
wide range of operation. Built-in interfaces provide pulses and RS485 Modbus RTU outputs. Configuration is password protected.
Power factor 4 quadrants
THD Up to 21st harmonic
2: 100mV
3: 333mV
5: 1A & 5A L1 L1
L2 L2
F: Basic version L3 L3
72mm
G: 4DI + 2DO N
Input Environment
Nominal input voltage 57.7-276V AC ( L-N ) 173-480V AC( L-L) Operating temperature -25˚C to +55˚C
V1 V2 V3 V4 V5 VN ( I1 ) ( I2 ) ( I3 ) V1 V2 V3 V4 V5 VN ( I1 ) ( I2 ) ( I3 )
+ - + -
1
A+ B- G
Height 96mm
1-phase 2-wire Width 96mm
Depth 50mm
Interface RS232/485/422 x 1
Modbus RTU to Modbus TCP Ethernet
10/100 Mbps, Rj45,
2 KV surge protection
RS485/422 Lsolation 2.5KV Baud Rate 1200bps~115200bps
Introduction
ESP-2000 series is a high performance serial device server and Modbus Gateway product designed by Eastron for lightning resistance ,
anti-eletromagnetic interference and resisting bad environment requirements, is the flagship product on serial device e server.
The Gateway are designed for easy integration of Modbus TCP and RTU networks. With those models, Modbus serial slave devices can
be seamlessly incorporated into an existing Modbus TCP network, and Modbus TCP salves can be made accessible to serial masters.
The ESP-2100, ESP-2200,ESP-2400,ESP2800 offer features that make network integration easy, customizable, and compatible with
any Modbus network.
ESP-2200 ESP-2400 ESP-2800
Parameter: Parameter: Parameter:
Rs232 Interface Rj45interface. qty. 2 Rs232 Interface Db9.qty. 4 Rs232 Interface Db9.qty. 8
Rs485 Interface Terminal, qty. 2 Rs485 Interface Terminal, qty. 4 Rs485 Interface Equip Db9to terminal pinboard, qty. 8
Rs422 Interface Need customized to open, qty. 2 Rs422 Interface 4 Line terminal, qty. 4 Rs422 Interface None
Input Voltage DC9~24V, power consumption less than 4W Input Voltage DC9~24V, power consumption less than 4W Input Voltage DC9~24V, power consumption less than 5.4W
Size L x W x H=9.4cmx6.5cmx2.5cm Size L x W x H=9.2cmx19.7cmx2.5cm Size L x W x H=27cmx10.5cmx2.6cm
ESP-2 —100—1
0 4(0.16)
RS232/422 RS232/422 Uplink 10/100M
0 6(0.24)
400: 4x RS232/422/485 ports
17.9
26 5
800: 8x RS232/485 ports 48 4
07 13.0 7
80(3.15)
6x8=48
95
43
(0.98)
95
88
88
(0.28)
25
11.5
(0.98)
25
Gateway ESP-2200
ESP-4000 SERIES
RS232/422/485 to WIFI ESP-5000 SERIES
RS232/485 to GPRS/3G/4G
Convert between RS232/422/485 to WIFI
Ethernet port available Support RS232/485 to GPRS ESP-5100
Each RS485 port supports up to 256 nodes Support RS232/485 to 3G/4G ESP-5307
Support Modbus TCP to RTU. Support RS232/485 to Ethernet
Support IEEE802.11g/b/n
Easy hardware setup
Introduction Introduction
ESP-4142 and ESP-4144 is Wifi serial device server designed by Eastron, supporting RS232/422/485 to Wifi. It supports Ethernet and
ESP-5 series covers 2G/3G/4G mobile network. It converts serial port RS232/RS485 to GPRS (ESP-5100) ,and to 3G/4G(ESP-5307). ESP-5100 is
Wifi simultaneous access. the host serial software can self-adapt serial parameter, without setting device serial baudrate.
good option for applications which does not ask high speed communication. ESP-5307 is advanced version with fater transmission speed.
The ESP-4000 series is a high performance serial device server and Wifi Gateway product designed by for lightning resistance ,
ESP-5307 supports TD-LTE/FDD-LTE/WCDMA/TD-SCDMA/GSM. An extra Ethernet port is provided, which can be used at same time when
anti-eletromagnetic interference and resisting bad environment requirements. it provides an easy and wireless integration way of
2G/3G/4G is working. P2P connection is also possible.
Modbus TCP and RTU networks. With those models, Modbus serial slave devices can be seamlessly incorporated into an existing
Modbus TCP network, and Modbus TCP salves can be made accessible to serial masters.
Parameter: Parameter:
Serial Port Type RS232/RS485 Transmission Rate 1)3G net speed:uplink 5.76Mbps downlink 7.2Mbps.
2)4G net speed:uplink 2Mbps downlink 68Mbps.
Baud Rate 1200~115200bps
Frequency range 900MHZ/1800MHZ,GPRS multi-slot class 10/8,GPRS SIM Card Voltage: 3V,1.8V; Size: Big Card
mobile station class B
Antenna Interface Optional 50Ω/SMA glue stick antenna or sucker antenna
WIFI IEEE802.11b/g
Transmission Rate Serial Port Type RS232/RS485
Downlink Max:85.6kbps;Uplink Max:42.8kbps;
Antenna Stick antenna, sucker antenna
Support PBCCH,Coding schemes CS 1,2,3,4,CSD Serial Parameter Baud Rate:1200~115200bps
up to14.4kbps, USSD, PPP-stack
Interface RS232/485/422 serial port
Power Port Q2.1 outlet, can be customized to power terminal input
Baud Rate 1200bps~115200ps SIM Card Voltage 3V,1.8V Input Voltage 9~24V DC
Interface Type 2 line Terminal or 5.5mm, inside positive outside negative, Size L×W×H=9.4cm×6.5cm×2.5cm
Power Interface In-positive, out-negative, standard outlet; 2 line terminal
standard power plug (alternative)
Work Temp. Humidity -40~85℃,5~95% RH
Input Voltage 9~48V input, less than 1W
Input Voltage 9~24V DC
Size L x W x H=9.4cmx6.5cmx2.5cm
Current No card or standby in 77mA
ESP-7000 SERIES
ESP-6000 SERIES Rs485 to LOR/Wifi/Ethernet
LORA to Ethernet
Support RS485 to Lora ESP-7100
Support Lora to Ethernet Support RS485 to Wifi ESP-7110
Support Lora to RS485 Support RS485 to Ethernet ESP-7120
Introduction Introduction
ESP-6 is a high-performance LoRa gateway that implements RS485 and LoRa, TCP / IP and LoRa-related translation functions. ESP-7 Series is a high-performance converter, to achieve RS485 and LoRa / WIFI / Ethernet conversion function. RS485 port can be connected
As a gateway in LoRa network, ESP-6 adopts LoRa ad hoc network communication mode, and LoRa meter or LoRa converter to the conventional RS485 communication meter, through the built-in processor, to achieve the conversion of the two communications.
can form a perfect LoRa remote meter reading system. LoRa network using MESH wireless Ad Hoc network, while supporting star, ESP-7100 converts RS485 to LoRa; ESP-7110 converts RS485 to Wifi; ESP7120 converts RS485 to Ethernet. With ESP series Gateway, , they can
cluster network, the depth of the leading network routing, automatically select the best route, up to 4 relay hopping; with be used to coperate with LoRa Gateway (ESP-6 series) to form a complete wire / wireless meter reading system.
routing auto-repair feature to achieve seamless new Add or delete devices without manual intervention in routing operations.
Input channel:
Output channel : Input channel: ESP-7100 Output :
Communication mode LoRaMESH or LoRaWan
Output port 1 Ethernet Input port Rs485 Modbus RTU Communication mode LoRaMESH or LoRaWan
Communication frequency 433Mhz, 470Mhz, 868Mhz, 915Mhz
Interface parameters RJ45,10/100Mbps Baud rate 1200 ~ 38400 bps Communication frequency 433Mhz, 470Mhz, 868Mhz, 915Mhz
Communication speed 2.93~0.5 kbpsA (Configurable)
Operating mode TCP server Parity bit None/Odd/Even Communication speed 2.93~0.5 kbps (Configurable)
Maximum transmit power 20dBm
Output port 2 RS485 Modbus RTU Stop bit 1/2 bit Maximum transmit power 20dBm
Receiver sensitivity -112dBm/9.6kbps @GFSK
Baud rate 1200 ~ 38400 bps Data bits 8 bit Receiver sensitivity -112dBm/9.6kbps @GFSK
Maximum communication 1.5km (urban road);2.5km (Open area)
Parity None/Odd/Even Max. Bus Load 32pcs Submeters
Maximum communication 1km (urban road);2km (Open area)
distance Point to point
Stop bit 1/2 bit distance Point to point
Networking mode MESHwireless ad hoc network,up to 4 relay hopping Temperature and humidity parameter:
Data bits 8 bit Networking mode MESHwireless ad hoc network,up to 4 relay hopping
Operating temperature -25 to 55°C
ESP-7110 Output :
Temperature and humidity parameter: Storage temperature -40℃to +70℃
Power supply parameters: WIFI IEEE802.11b/g
Operating temperature -25 to 55°C Humidity range 0 to 95%, No condensation
Supply voltage 9~24VDC, maximum power consumption<2.5W Antenna Stick antenna, sucker antenna
Storage temperature -40°Cto +70°C
Maximum input voltage 28VDC Power supply parameters:
Humidity range
ESP-7120 Output :
0 to 95%, No condensation
Supply voltage 9~24VDC, maximum power consumption<1.5W
Ethernet 10/100 Mbps, RJ45,2 KV surge protection
Maximum input voltage 28VDC
TCP Server, TCP Client,UDP/UDP Multicast,
Work Mode
TCP Server/Client Coexist
81
Accuracy Class 0.5 or 1 from 20% to 120% of rated current Overload withstand 1.2 x rated current continuously
26
Phase angle Less than 2 degrees at 50% of rated current Rated dynamic current 2.55 x Ith
Insulation voltage 600 Vac
16
Secondary terminals M4 screw terminals
58.0
Maximum primary voltage 5000 Vac ( Insulated Conductor) Enclosure Flame retardant grad classified UL 94V-0 77.0
Dielectric strength 2.5 KV / I mA / I min Aperture holes centers 25,35,45mm
107.5
Operating temperature -15°C to 60°C Plug-in metal feet for wall or base Mounting ESCT-SC325
Mounting hardware
Operating humidity <85% Bus-bar and DIN-rail
Case material PC / UL 94-VO Compliant with IEC/EN60044-1
Bobbin PBT
Internal structure Epoxy
Compliant with IEC/EN60044/1 Model Ratio (A) Burden ( VA)
14
class:0.5 Class:1.0
5
13 ESCT-SC325 60/1 or 0.5 - 1
ESCT-RJ335 - 86.0
ESCT-SC325 100/1 or 0.5 1.5
Model Rated Amp Output Burden ( VA)
class:0.5 Class:1.0 ESCT-SC325 125/1 or 0.5 1.5 1.5
ESCT-RJ335 60A 100mV/100mA 0.25 0.25 ESCT-SC325 150/1 or 0.5 1.5 1.5 ESCT-SC335
ESCT-RJ335 125A 100mV/100mA 0.25 0.5 ESCT-SC325 300/1 or 0.5 1.5 1.5
ESCT-RJ335 150A 100mV/100mA 0.25 0.5
91
91.0
31.0
31
ESCT-RJ345 300A 100mV/100mA 0.25 0.5 ESCT-SC335 200/1 or 0.5 1.5 1.5 31.0
ESCT-RJ345 400A 100mV/100mA 0.25 0.5 142 ESCT-SC335 250/1 or 0.5 1.5 1.5 123.0
ESCT-RJ345 500A 100mV/100mA 0.25 0.5 142.0
ESCT-RJ345 600A 100mV/100mA 0.25 0.5 ESCT-C345 250/1 or 0.5 1.5 1.5 ESCT-SC345
ESCT-RJ345 630A 100mV/100mA 0.25 0.5 ESCT-C345 300/1 or 0.5 2.5 2.5
ESCT-C345 400/1 or 0.5 2.5 2.5
ESCT-C345 500/1 or 0.5 2.5 2.5
14
5
600/1 or 0.5 2.5 2.5
ESCT-RJ345 ESCT-C345
13
ESCT-C345 630/1 or 0.5 2.5 2.5
Split Core
Cost effective three-phase moulded case
Primary input 100A~6000A
Ratio’s ranging from 60/5 to 630/5
Secondary output 5A / 1A
ESCT-C Series Integrated wire sealable terminal cover ESCT-B Series Two building fixing methods: Base; Busbar mounting
3-IN-1 CURRENT TRANSFORMER Busbar, DIN-rail and metal feet mounting hardware supplied SPLIT CORE CURRENT TRANSFORMER Wide inner window, allowing clamping of big cables or bus-bars
Combined M4 posi /slot screw
Standard: IEC60044-1, EN60044-1, VDE0414-44-1, GB1208-2006
Dimensions
Specification Specification
Dimensions
Rated current 60A to 630A loads Frequency 50Hz-60Hz
Rated output 5A ( AC ) Rated current 100A to 6000A loads
Accuracy Class 0.5 or 1 from 20% to 120% of rated current Rated output 5A / 1A ( AC )
Phase angle Less than 2 degrees at 50% of rated current Accuracy Class 0.5 or 1 from 20% to 120% of rated current
105
20
30
Insulation voltage 600 Vac S1 S2 S1 S2 S1 S2
Phase angle less than 2 degrees at 50% of rated current
Maximum primary voltage 5000 Vac ( Insulated Conductor) Insulation voltage 600Vac
60
80
Dielectric strength 2.5 KV / I mA / I min Maximum primary voltage 5000Vac ( Insulated Conductor)
14
25
Operating temperature -15°C to 60°C Dielectric strength 2.5 KV / I mA / I min
24
Operating humidity <85% Operating temperature -15°C to 60°C ESCT-B23
Case material PC / UL 94-VO 77 Operating humidity <85%
Bobbin PBT 77 Case material PC / UL 94-VO
Internal structure Epoxy Bobbin PBT
ESCT-C325 Internal structure Epoxy 50
80
145
70
52
32
Model Ratio (A) Burden ( VA) Model Burden ( VA)
class:0.5 Class:1.0 Ratio (A) class:0.5 Class:1.0
ESCT-C325 60/5 - 1 S1 S2 S1 S2 S1 S2 ESCT-B23 100/5 1.5 2.5 114
ESCT-C325 100/5 - 1.5 ESCT-B23 150/5 1.5 2.5 ESCT-B58
80
38
25
145
ESCT-C335 ESCT-B58
-
70
52
32
ESCT-C335 125/5 2.5 ESCT-C335 ESCT-B58 300/5 2.5 5
ESCT-C335 150/5 - 3.75 ESCT-B58 400/5 3.75 5
ESCT-C335 160/5 1.5 1.5 ESCT-B58 500/5 5 7.5 144
ESCT-C335 200/5 1.5 1.5 ESCT-B58 600/5 5 7.5
ESCT-C335 250/5 1.5 1.5 ESCT-B58 750/5 5 10 ESCT-B88
S1 S2 S1 S2 S1 S2
ESCT-B58 800/5 5 10
ESCT-C345 250/5 1.5 1.5 ESCT-B58 1000/5 7.5 10
38
95
185
30
120
80
ESCT-C345 400/5 2.5 2.5 ESCT-B812 600/5 2.5 5
70
52
32
45 141
ESCT-C345 500/5 2.5 2.5 ESCT-B812 750/5 5 10
ESCT-C345 600/5 2.5 2.5 ESCT-B812 800/5 5 10
2.5 141
ESCT-C345 630/5 2.5 ESCT-C345 ESCT-B812 1000/5 7.5 10 144
ESCT-B812 1200/5 7.5 10
ESCT-B812
ESCT-B812 1250/5 7.5 10
ESCT-B812 1500/5 7.5 10
ESCT-B816 1000/5 10 15
ESCT-B816 1500/5 10 15
245
80
160
ESCT-B816 2000/5 15 20
87
71
50
ESCT-B816 2500/5 20 25
ESCT-B816 3000/5 20 30
ESCT-B816 4000/5 20 30 184
ESCT-B816 5000/5 20 30 ESCT-B816
ESCT-B816 6000/5 20 30
59 Product Catalog EASTRON Product Catalog EASTRON 60
CURRENT
SMART TRANSFORMER
DIN-RAIL METER
72.0
Insulation voltage 600Vac Insulation voltage 600Vac ESCT-TU10 5 100 0.5 or 1
Maximum primary voltage 5000Vac (Insulated Conductor) Maximum primary voltage 5000Vac (Insulated Conductor) ESCT-TU10 10 100 0.5 or 1
Dielectric strength 2.5KV/1mA/1min Dielectric strength 2.5KV/1mA/1min ESCT-TU10 20 100 0.5 or 1
44.0 39.0
Operating temperature -15 °C to 60 °C . Operating temperature -15 °C to 60 °C . ESCT-TU10 50 100 0.5 or 1
Operating humidity <85% Operating humidity <85% ESCT-TU10 75 100 0.5 or 1
ESCT-T24-1 Case material PC / UL94-V0
Case material PC / UL94-V0
Bobbin PBT Bobbin PBT ESCT-TU16 5 333 0.5 or 1
Core Permalloy 36.8 Core Permalloy ESCT-TU16 10 333 0.5 or 1
85.5
42.0
ESCT-T24-1 250/1 1.5 2.5
ESCT-T24-1 300/1 1.5 2.5 25.0
150/1 - 1.5
ESCT-TU10 ESCT-TU24 100 333 0.5 or 1
ESCT-T36-1
200/1 ESCT-TU24 250 333 0.5 or 1
ESCT-T36-1 1.5 2.5 44.0 39.0
54.5
400/1 ESCT-TU24 10 100 0.5 or 1
ESCT-T36-1 1.5 2.5
ESCT-T24-5 ESCT-TU24 50 100 0.5 or 1
ESCT-T36-1 500/1 2.5 3.75
600/1 ESCT-TU24 100 100 0.5 or 1
ESCT-T36-1 2.5 5
30.0 31.5 ESCT-TU24 250 100 0.5 or 1
36.8
ESCT-TU16 ESCT-TU24 300 100 0.5 or 1
85.5
72.0
250/5 ESCT-TU36 100 333 0.5 or 1
ESCT-T24-5 1.5 2.5
56.0 42.0
300/5 ESCT-TU36 250 333 0.5 or 1
ESCT-T24-5 1.5 2.5
ESCT-TU36 400 333 0.5 or 1
ESCT-T36-5
100/5 44.0 39.0 ESCT-TU36 600 333 0.5 or 1
ESCT-T36-5 - 1.5
ESCT-T36-5 150/5 - 1.5 ESCT-TU24 ESCT-TU36 20 100 0.5 or 1
Dimension
Specification
Specification Model Rated Amps Class Coil Length Window
A
Size
B Type No.
Frequency 50-60Hz
Rated current 5A to 3000A loads Current Range 10A to 100kA ESCT-RC16 100A 0.5 80 22 16 C
Rated output 333mV (AC) Rated output 0.333Vac at rated current with Integrator, ESCT-RC24 300A 0.5 97 27.5 24 C
Accuracy ±1% from 20% to 120% of rated current 100mV/per 1000A @ 50Hz without integrator ESCT-RC36 600A 0.5 130 36 37 C
Phase angle less than 2 degrees at 50% of rated current Accuracy ±1% from 5% to 120% of rated current with ESCT-RC60 500A 0.5 200 60 50 A
Insulation voltage 600Vac integrator(45-65Hz) ESCT-RC100 1000A 0.5 395 135 100 B
Maximum primary voltage 5000Vac (Insulated Conductor) Phase Angle ≤±1°5% to 120% from 5% to 120% of rated current ESCT-RC105 1500A 0.5 350 105 100 A
Dielectric strength 2.5KV/1mA/1min Linear 0.5% ESCT-RC150 3000A 0.5 525 165 150 B
Operating temperature -15 °C to 60 °C . Frequency 1Hz-1MHz ,50/60 Hz nominal ESCT-RC200 6000A 0.5 665 240 200 B
Operating humidity <85% ESCT-U75 Work Voltage 600V ESCT-RC240 10000A 0.5 800 245 240 A
Case material PC / UL94-V0 Power supply 7-30VDC (9 Vdc,12 Vdc recommended )
Bobbin PBT Coil Diameter 10.5mm,12mm or as customer order ESCT-3RC16 100A 0.5 80 22 16 C
Core Permalloy Window size 10mm,15mm or as per customer ordered ESCT-3RC24 300A 0.5 97 27.5 24 C
Internal structure Epoxy Wire lead 1 meter sheath cable or as customers order ESCT-3RC36 600A 0.5 130 36 37 C
Leads UL 1015,Twisted Pair, 22AWG Withstand Voltage 3000V ESCT-3RC60 500A 0.5 200 60 50 A
Operating temperature -25°C-+70°C ESCT-3RC100 1000A 0.5 395 135 100 B
Model Rated Amps Output(mV) Accuracy IP class IP65 ESCT-3RC105 1500A 0.5 350 105 100 A
ESCT-U75 5 333 0.5 or1 Certification CE recognized. RoHS Compliant ESCT-3RC150 3000A 0.5 525 165 150 B
ESCT-U75 10 333 0.5 or1
ESCT-U125 ESCT-3RC200 6000A 0.5 665 240 200 B
ESCT-U75 50 333 0.5 or1 ESCT-3RC240 10000A 0.5 800 245 240 A
ESCT-U75 75 333 0.5 or1
ESCT-U75 100 333 0.5 or1 Type A: RC60 RC105 RC240 Type A:
ESCT-U75 125 333 0.5 or1 A.Windows Size A 60 105 245
ESCT-U75 150 333 0.5 or1 B.Windows Size B 50 100 240
200 333 0.5 or1 C.Coil O.D. 66 121 261
ESCT-U75
50 333 0.5 or1 D.Coil Section 8
ESCT-U125
E.Lead Cable Total Length 2000
ESCT-U125 100 333 0.5 or1
F.Coil Length 200 350 800
ESCT-U125 200 333 0.5 or 1
ESCT-U125 250 333 0.5 or 1 ESCT-U200
4 00 333 0.5 or1
Type B: RC100 RC150 RC200 Type B:
ESCT-U125
A.Windows Size A 135 165 210
ESCT-U125 600 333 0.5 or1
B.Windows Size B 100 150 200
ESCT-U125 630 333 0.5 or1
C.Coil O.D. 151 181 226
ESCT-U200 100 333 0.5 or1
D.Coil Section 8
ESCT-U200 125 333 0.5 or1 E.Lead Cable Total Length 2000
ESCT-U200 250 333 0.5 or1
F.Coil Length 395 525 665
ESCT-U200 400 333 0.5 or1
ESCT-U200 630 333 0.5 or1
Type c: RC16 RC24 RC36 Type c:
ESCT-U200 800 333 0.5 or1 ESCT-U250 A.Windows Size A 22 27.5 36
ESCT-U200 1000 333 0.5 or1 B.Windows Size B 16 24 37
ESCT-U200 2000 333 0.5 or1 C.Coil O.D. 24 39.5 48
ESCT-U300 400 333 0.5 or1 D.Coil Section 6
ESCT-U300 800 333 0.5 or1 E.Lead Cable Total Length 2000
ESCT-U300 1000 333 0.5 or1 F.Coil Length 80 97 130
ESCT-U300 1500 333 0.5 or1
ESCT-U300 2500 333 0.5 or1
ESCT-U300 3000 333 0.5 or1
ESCT-U300
63 Product Catalog EASTRON Product Catalog EASTRON 64
CURRENT
SMART TRANSFORMER
DIN-RAIL METER
Specification Introduction
Specification Introduction
Rated Frequency 50Hz-60Hz
ESCT-ABO perfect designed plastic case current transformer, advanced Rated Frequency 50Hz-60Hz
Rated current 5A to 3000A loads
snap on body, high accuracy ( up to Class 0.2S), humanization transparent ESCT-DM is world famous MINI design plastic case current transformer,
Rated output 5A, 1A, 0.5A, 0.25A, 0.1A Rated current 50A to 300A loads
cover and lead seal hole design makes the CT very easy to identify after snap on body, be wildly used in generators. It is available for connecting
Accuracy ±1% from 20% to 120% of rated current Rated test voltage 3kV AC ( 1min)
long term use and perfect anti-stealing electricity. Rated short-time thermal current (Ith) 60In with cable, and also available for connecting with Busbas. Its primary
Rated short-time thermal current (Ith) 60In
Rated voltage (Um) 0.72Kv AC. currents between 50A~300A with 5A secondaries with up to
Rated voltage (Um) 1.2 In
-10°C~50°C Dimension Rated output 5A or 1A Class1.0 accuracy Performance.
Operating temperature
Housing self-extinguishing class VO Rated voltage (Um) 1.2 In
Description Description
Specification Panel Symbol legend
Output relay ON Specification Panel 1 2 3 4 5 6 7 Days of the week Monday, Tuesday, ...Sunday
Output relay OFF
Supply terminals A1,A2 Supply terminals A1-A2 C1 Channel 1
Output relay 1
Pulse terminal S Rated voltage AC220-240V Relay status: Activate
Output relay 2
Rated frequency 50/60Hz Deactivate
Supply voltage AC/DC 24-240V ONStart SET Parameters setting
Automatic mode
min
ONStart Starting with ON
Power consumption 1W
Rated frequency 50/60Hz t
Manual mode
OFFStart Starting with OFF
Supply volltage tolerance ±10%
Time range 0~9999s, 0~9999min 1 Holiday mode
Time impulse release by rising edge Number of channels
Repetition accuracy max.±3s/24h 25 ºC Time impulse release by falling edge Program astronomical
Sunrise
-5ºC~+40ºC
Wiring diagrams Pollution degree 3
Ambient temperature Wiring diagrams
-10ºC~+50ºC L Altitude ≤2000m
Storage temperature
0.5mm~1mm
2 2 N Ambient temperature -30°C~55°C
Wire size
Permissable relative humidity ≤50%(40°C,without condensation)
Torque 0.5Nm A1
Storage temperature -35°C~70°C
Mounting TH-35 DIN-Rail Wire size 2 2
A1 15
1mm ~ 4mm
A1 15 25
25 28 A1 A2
Tightening torque 0.5Nm
24-240V
50/60Hz Mounting TH-35 Rail(EN60715)
Front-face panel Dimensions 90*36*64mm Menu Ok
Standard IEC60947-1/IEC60947-2-7
S A2 18 16 28 C1
A2 18 16 18 15 16 A2
Front-face panel
Relay 2 Output contact Supply terminals MENU OK
:DD-MM-YY, 23th.September.2013
18 15 16 S N
Supply terminal L L
25 28 A1 A2 24-240V
Dimensions
50/60Hz
Dimensions
LCD display
OFFStart
A1
220-240V
t1 50/60Hz L
25 28 A1 A2
24-240V
50/60Hz
1 LCD display
35
45
C1
Keys
90
MENU OK
35
45
90
Menu ok
Control keys
MENU OK Menu Ok
C1
18 15 16 S 18 15 16 N
18 15 16 S C1 26
18 15 16 A2 44
Relay 1 Output contact Pulse terminals
26 60
36
44 65
Output - channel 1 Supply terminal N
60 36
65
ESRD-TPW1/2 Double channels ESRD-ST1 LED indication for power supply and relay status
DOUBLE CHANNEL DIGITAL WEEKLY Automatic transfer of weekdays DIN Rail mounting
24-264V AC/DC input supply
TWILIGHT SWITCH
Double-module, mounted on TH-35 rail
Function diagram
Specification Specification
Supply terminals A1-A2
Description
Panel 1 2 3 4 5 6 7 Days of the week Monday, Tuesday, ...Sunday Ambient light intensity
Rated control voltage AC220V
Rated voltage AC220-240V Hystersis
Rated insulation voltage 250V ○C1 manual operation ○C2 manual operation
C1 C2
Protection degree IP20 Ambient temperature -25ºC~+40ºC LIGHT DEPENDENT RELAY
Un:AC220V 50/60Hz
U
L 25A AC1
Pollution degree 3
Altitude ≤2000m Wiring diagrams
B1
Ambient temperature -20°C~55°C Front-face panel B2
Lux
Permissable relative humidity ≤50%(40°C,without condensation) ESRD-ST1
28 25 26 A1
Storage temperature -30°C~70°C A1
C2 N C B1 B2
Output contact Supply terminal
Wire size 1mm ~ 4mm
2 2
A1 15
Tightening torque 0.5Nm A1 15 25
Mounting TH-35 Rail(EN60715)
Menu ok
C L N ST110
C1
220V
Standard IEC60947-1/IEC60947-2-7 A2 18 16
C1 18 15 16 A2 50/60Hz
Dimensions
18 15 16 A2 A2 18 16 28 26 Supply indication (yellow)
Output indication(red)
Front-face panel TWILIGHT SWITCH
Un:AC220V 50/60Hz
25A AC1
:DD-MM-YY, 23th.September.2013 N Sensitivity adjustment
N L1
L
C L N
L2 220V
Output - channel 2 Supply terminal A1 50/60Hz
35
25A AC1
45
90
28 25 26 A1 220-240V
B1 B2
C2 50/60Hz
28 25 26 A1
ESRD-ST1
C2
1 LCD display
C1 Sensor input terminal
C2 B1 B2
35
45
Microcontroller based
Microcontroller based Modular design,18mm wide housing
Modular design, 18mm wide housing
Possibility of 3 wire or 4 wire connection
10 operating modes
10 time ranges(1s,10s,1m,10m,1h,10h,1d,10d,ON,OFF) ON,OFF,AUTO three operation modes
ESRS-TM11/12/14/23 1 changeover contact ESRD-TSL Series Repetition accuracy<0.2%
MULTIFUNCTION TIME RELAY LED indication for power supply and relay status LCD indication for relay status
DIN-Rail mounting STAIRCASE LIGHTING TIME
DIN-Rail mounting
1h 10h 1h 10h
Inductive load,cos$=0.6@230V 650W
Repetition accuracy <0.2% 10m 1d 10m 1d
1m 10d
ON
1m 10d
OFF
Mechanical life 10 5
10s ON 10s ON
Output contacts 1 C/O 6
1s OFF 1s OFF Electrical life 10
Current rating 8A /AC1 Time range
0.5 0.6
0.5-20m
1d T1
1h 10h
Contacts capacity AC-15: 2A 10m
1m 0.3
0.4 0.7
0.8 Time adjustment: Setting accuracy ≤5%
10d
10s ON T 0.2 0.9 ×T
Insulation voltage 250V 1s OFF
0.1 1 t=10m x 0.3 = 3 min Repetition accuracy ≤0.2%
Protection degree IP20 Maximum load of illuminated switch 50mA
1h 10h 0.5 0.6
10m 1d T2 0.4 0.7
Pollution degree 3 1m 10d 0.3 0.8 Time adjustment: Reset time ≥200ms
10s ON T 0.2 0.9 ×T
Electrical life 10
5
1s OFF
0.1 1 t=1d x 0.7 = 0.7day Altitude ≤2000m
Mechanical life 10 6 Protection degree IP20
Altitude ≤2000m Wiring diagrams Pollution degree 3
A1 15 A1 15 25 Ambient temperature -5°C~+40°C 4 wire connection
Ambient temperature -5ºC~+40ºC A1 A3 15
A1 S A2 A1 S A2 AC/DC 24V A1 S A2
Time setting
Front-face panel
A3
Output indication LED(red)
Supply terminals A1,A2
A1 S A2
ESRS-TM11
28 25 26 Function selecting
Supply terminals A3
Pulse terminal A3 18 15 16 18 15 16
18 15 16
ESRS-TM11/14 ESRS-TM12 Dimensions
ESRS-TM23
Supply indication(green) RS-TSL
U
Dimensions
Multi-function
output indication(red)
Functions setting
C
D
E F
G
H
A1 S A2
FUNCTION DIAGRAM
B I FUNC A3
Time setting A J
1h 10h
10m 1d
1m 10d
T U
85.6
10s ON Multi-function
45
.5 .6
.4 .7 D
E F
G
.3 .8 C H
44.5
B I FUNC
.2 .9 ×T A J
90
1h 10h
10m 1d
.1 1 1m 10d
10s ON T
ESRS-TM11 1s
0.4
0.5 0.6
OFF
0.7
0.3 0.8
0.2 0.9 ×T ESRS-TSL
0.1 1
ESRS-TM12
30
18 15 16 49
18
18 15 16 60 65
Output contact
17.8
65