You are on page 1of 64

Ivesta 3 Series

User Manual
Contents
General Notes Assembly
Important Safety Notes 5 Assembling the Optics Carrier and Additional Objective 31
Symbols Used  6 Available Optional Graticules 32
Safety Instructions  7 Inserting the Graticules 33
End User License Agreement (EULA) 11 Inserting the Eyepieces 34

Introduction Operation
The Ivesta 3 Series 13 Using the Eyepieces 36
What Your Stereo Microscope has to Offer You 14 Setting the Correct Interpupillary Distance 37
Microscopes of Ivesta 3 Series  15 Changing Magnification (Zooming) 38
Overview of Ivesta 3 and Ivesta 3 (C-mount)  16 Regulating the Resistance of the Focusing Drive 39
Overview of Ivesta 3 (Integrated camera)  17 Changing the Position of the Optics Carrier 40
Operating Elements and Connectors of Ivesta 3 (Integrated Camera) 20 Switching on Ivesta 3 (Integrated camera)  41
Standard Delivery and Optional Accessories of Ivesta 3 (Integrated Operation in Stand-Alone Mode  42
camera) 21 Operation in PC Mode 43
Operation in Network Mode  44
Installation
Installing the Camera on Ivesta 3 (C-mount) 23 Troubleshooting
Connectivity of Ivesta 3 (Integrated camera) 24 Troubleshooting  48
Stand-Alone Mode: General Notes 25 Recovery Mode 49
Stand-Alone Mode: Cables and Terminals 26
Stand-Alone Mode: Installing USB Thumb Drive 27 Care and Maintenance
Stand-Alone Mode: Installing Wireless USB Mouse 28 Care, Maintenance, Contact Persons 51
PC Mode: Connecting a Computer, Installing Software  29

Ivesta 3 Series User Manual   2


Contents (Continued)
Specifications
Spare Parts 54
Optional Sales Items 55
Technical Data 56
Dimensional Drawings Ivesta 3 59
Dimensional Drawings Ivesta 3 (C-mount) 60
Dimensional Drawings Ivesta 3 (Integrated camera) 61

Appendix
Calculating the Total Magnification/Field of View Diameter 63

Ivesta 3 Series User Manual   3


General Notes

Ivesta 3 Series User Manual General Notes 4


Important Safety Notes

This user manual describes the usage of For information on the Enersight OSD in To maintain the camera in its original condition
Ivesta 3 Series and contains important instruc- stand-alone mode, Enersight Desktop and to ensure safe operation, the user must
tion for operating safety, maintenance and the and Enersight Mobile, refer to the website follow the instructions and warnings contained
accessory parts. Microscope Software Platform Enersight or in these user manuals.
scan the QR code to be directed to Enersight
User manuals are available for you to
web-page:
download and print from our website at
www.leica-microsystems.com.
If you purchased an Ivesta 3 (Integrated camera),
you can find information on the USB stick
together with all relevant user manuals in addi-
tional languages. Keep this USB stick in a safe
place, where it is availabe to the user.
The "Safety Concept" booklet contains additi-
onal safety information regarding the service
work, requirements and the handling of the
camera, accessories and electrical accessories
as well as general safety instructions.
Before installing, operating or using the camera
and the accessories, read the user manuals
listed above. In particular, please follow all
safety instructions.

Ivesta 3 Series User Manual General Notes 5


Symbols Used

WARNING! Safety hazard! WARNING UK RESPONSIBLE PERSON


Failure to comply with the following warnings Camera malfunctions and Leica Microsystems (UK) Limited
can cause the following: damage. Larch House, Woodlands Business Park, Milton
Keynes, England, United Kingdom, MK14 6FG
O Personal injury! This symbol warns against touching
O Device malfunctions and damage. hot surfaces, such as light bulbs.

WARNING
NOTICE
Serious injuries caused by...
This warning label warns of damage to the
This warning label warns of general
device and other equipment.
hazards that can cause serious or
fatal injuries.
IMPORTANT INFORMATION
WARNING This symbol indicates additional
Electric shock. information or explanations that are
intended to provide clarity.
This warning label warns of dange-
rous electrical voltage. The instruc-
tions must be followed without fail, X Read and understand this user
otherwise there is a risk of serious or manual before using this device.
fatal injury.

Ivesta 3 Series User Manual General Notes 6


Safety Instructions

Safety concept Cleaning Responsibilities of person in charge of


Before using your Leica camera for the first X Do not use any unsuitable cleaning agents, camera
time, please read the "Safety Concept" booklet chemicals or techniques for cleaning. X Refer to "Safety Concept" booklet.
included with your camera. It contains additio-
X Never use chemicals to clean colored X Ensure that:
nal information on handling and care.
surfaces or accessories with rubberized
– your Ivesta 3 Series microscope and
parts. This could damage the surfaces, and
accessories are operated, maintained
specimens could be contaminated by abra-
and repaired by authorized and trained
ded particles.
personnel only.
– all operators have read, understood
Repairs, service work
and observe this user manual, and
X Refer to "Safety Concept" booklet. particularly the safety regulations.
X Use only original Leica Microsystems spare
parts.
X Before opening the camera, switch off the
power and unplug the power cable.
X Avoid contact with powered electrical
circuits, which can lead to injury.

Ivesta 3 Series User Manual General Notes 7


Safety Instructions (Continued)

Description The responsible Leica affiliate must be consul-


The individual modules fulfill the high require- ted whenever the camera is altered, modified
ments for observation and documentation of or used in conjunction with non-Leica compo-
Ivesta 3 Series stereo microscopes. nents that are outside of the scope of this user
manual!

Intended use Unauthorized alterations to the camera or


noncompliant use shall void all rights to any
X Refer to "Safety Concept" booklet.
warranty claims.

Non-intended use
Place of use
X Refer to "Safety Concept" booklet.
X Refer to "Safety Concept" booklet.
X Never use Ivesta 3 Series or its components
X Place electrical components at least 10 cm
for diagnostic or surgery procedures if it is
away from the wall and from flammable
not expressly intended for such use.
substances.
The camera and accessories described in this
X Avoid large temperature fluctuations, direct
user manual have been tested for safety and
sunlight and vibrations. These conditions
potential hazards.
can distort the functionality of the camera.
X In warm and damp climates, give the indi-
vidual components special care in order to
prevent the build-up of fungus.

Ivesta 3 Series User Manual General Notes 8


Safety Instructions (Continued)

Transport Disposal Health risks


X Before shipping Ivesta 3 (Integrated After the end of the product’s life, please Workplaces with microscopes and cameras faci-
camera), please reset the mircoscope to contact Leica Service or Leica Sales on how to litate and improve the viewing task, but they
the factory default, so that no personal dispose of it. also impose high demands on the eyes and
data like access details to E-Mail or network muscles of the user. Depending on the dura-
Like all electronic devices, Ivesta 3 (Integrated
remain stored on the camera. tion of uninterrupted work, asthenopia and
camera), its components and accessories may
musculoskeletal problems may occur. For this
X Use the original packaging for shipping or not be disposed of as general household waste!
reason, appropriate measures for reduction of
transporting the individual modules of the
Please observe the national the workload must be taken:
Ivesta 3 Series microscope and the acces-
sory components. laws and ordinances which, for O Optimal arrangement of workplace, work
example, implement and ensure assignments and work flow (changing tasks
X In order to prevent damage from vibrations, compliance with EU directive frequently).
disassemble all moving parts that (accor- WEEE 2012/19/EU. O Thorough training of the personnel, giving
ding to the user manual) can be assembled
consideration to ergonomic and organizati-
and disassembled by the customer and
Legal regulations onal aspects.
pack them separately.
X Refer to "Safety Concept" booklet. The ergonomic optical design and construction
Integration in third-party products of microscopes and cameras from Leica are
EC Declaration of Conformity intended to reduce the exertion of the user to
X Refer to "Safety Concept" booklet.
X Refer to "Safety Concept" booklet. a minimum.

Ivesta 3 Series User Manual General Notes 9


Safety Instructions (Continued)

Microscope safety and EMC Ivesta 3 (Integrated camera) meets the compliance with the environment.
Ivesta 3 (Integrated camera) has requirements of EU directives:
If the instrument is being installed in any other
been designed, produced and tested in O 2014/35/EU Low voltage directive environment than an INDUSTRIAL, it cannot be
compliance with: O 2014/30/EU EMC directive guaranteed that the equipment does not inter-
O 2011/65/EU RoHS directive fere with other electronic devices.
O EN 61010-1: Safety requirements for elec-
O 2009/125/EC + VO EU 2019/1782
trical equipment for measurement, control, INDUSTRIAL environments are part of a sepa-
Ecodesign requirements for energy-rela-
and laboratory use - Part 1: General require- rate power network, in most cases supplied by
ted products only applicable for external
ments (for microscope) a high- or medium-voltage transformer, dedi-
power supply
O EN 62368-1: Audio/video, information and cated for the supply of installations feeding
communication technology equipment - and carry the CE mark. manufacturing or similar plants.
Part 1: Safety requirements (for optional
Strong electromagnetic fields in the immediate
external power supply only) Intended for indoor use only in all EU
vicinity of the device can lead to a malfunction
O Radio interference suppression in compli- member states, EFTA states and Switzerland.
of the screen display.
ance with EN 55011 Class A
Ivesta 3 (Integrated camera) must be
O EN 61326-1, Electrical equipment for NOTICE
disposed of in accordance with EU directive
measurement, control and laboratory use –
WEEE 2012/19/ EU. If Ivesta 3 (Integrated camera) is being
EMC requirements
installed in any other environment than an
INDUSTRIAL, it cannot be guaranteed that
EMC precautions
the radiated electromagnetic emissions are
Prior to the installation of Ivesta 3 not interfering with other electronic devices.
(Integrated camera), the electromagnetic
environment needs to be evaluated.
It is the responsibility of the operator to ensure

Ivesta 3 Series User Manual General Notes 10


End User License Agreement (EULA)

This End User License Agreement is ente- When sending or forwarding Ivesta 3 (Integra-
red into by and between Leica Microsystems ted camera) to third parties for any reason, or
("Leica") and you, the end user, as the context when returning Ivesta 3 (Integrated camera)
requires, either individually or as an authorized to Leica for service or maintenance, the User
representative of the company or organization should always reset the microscope to factory
acquiring and/or using this camera ("User"). settings.
Ivesta 3 (Integrated camera) can be used Use of network and/or other connectivity func-
in a network and offers functionality such tionality provided by or with this camera are at
as automated submission of images to an the User´s discretion and risk; specifically, the
E-Mail recipient defined by the User, or copy- User assumes full responsibility for network
ing of images to a SMB file server selected by operation and safety. Leica does not guaran-
the User. Therefore, passwords will need to tee any particular network safety standard and
be chosen by the User which passwords will declines all responsibility, without limitation,
be stored on the camera in a separate pass- for unauthorized access, security breach, data
word file. Direct access to the password file is loss or corruption, or any financial or legal
denied; passwords are stored with an encryp- consequences thereof.
tion which follows the Advanced Encryption
Standard (AES), with a block and key size of
128 bits.
During any firmware update this password file
will be deleted and the User will need to reenter
the passwords.

Ivesta 3 Series User Manual General Notes 11


Introduction

Ivesta 3 Series User Manual Introduction  12


The Ivesta 3 Series

Congratulations on obtaining your new Leica Despite this, you will notice that the controls
stereo microscope from the Ivesta 3 Series. We and individual components do not differ signi-
are convinced it will exceed your expectations, ficantly. Whichever configuration you choose,
as this instrument embodies all the qualities you will quickly feel right at home with your
you associate with Leica Microsystems: excel- new stereo microscope.
lent objectives, high-quality engineering, and
Though the reliability and robustness of Leica
reliability. Furthermore, the modular design
stereo microscopes is world-renowned, like any
ensures that the Leica stereo microscope
high-tech product, the Ivesta 3 Series requires a
adapts perfectly to your needs – no matter
certain degree of care and attention. Therefore,
which accessories you require for your tasks.
we recommend that you read this manual. It
Thanks to the parfocal system with simultane- contains all the information you need regarding
ously large working distances and object fields, operation, safety and maintenance. Simply
you can always view your microscopic speci- observing a few guidelines will ensure that
mens accurately – from the complete image to even after years of intensive use, your stereo
the finest detail. microscope will continue to work as smoothly
and reliably as on the very first day.
The Ivesta 3 Series provides a high degree
of flexibility in choosing equipment, thanks We wish you the best of success in your work!
primarily to the modular configuration and the after all, you are now equipped with the best
compability that Leica has painstakingly main- tool!
tained for decades. The optic carriers, eyepie-
ces, stands, and more can be combined in any
way you choose, allowing you to create the
stereo microscope that best suits your needs.

Ivesta 3 Series User Manual Introduction  13


What Your Stereo Microscope has to Offer You

The optical system of the Ivesta 3 Series stereo Patented FusionOptics Technology Apochromatic correction
microscopes consists of two beam paths The Ivesta 3 Series features the Leica patented The Ivesta 3 Series is a completely apochro-
converging at 10°. The objective pairs of each FusionOptics technology and deliver you finest matically corrected Greenough system. The
optical path are positioned close together, so details in 3D. While the right channel delivers modern optical technology of the Ivesta 3
the stereo microscopes can be of very "slen- you a high-resolution image at the largest Series corrects chromatic aberration perfectly,
der" design, especially towards the base of the possible numerical aperture, the left channel removes bothersome color seams and displays
instrument. The advantages of this design are presents an image with high depth of field. This pin-sharp images of even the finest enlarged
that it has a small space requirement for use on results in an image perception with outstan- detail. Contrast, brilliance, image sharpness,
bonders and in machine applications, unobst- ding richness of details and exeptional depth of resolution, color fidelity and image precision
ructed access to specimens, plenty of space for field at the same time. are unsurpassed.
tools and a completely clear view of the object
field. The benefit of apochromatic correction is best
Photography seen in specimens that have a fine, low-contrast
The Greenough system enables cost-effective structure such as large animal cells, cilia plants
Ivesta 3 (C-mount) is equipped with an inte-
correction of aberrations such as chromasia, or metallic microelectronic structures.
grated video/phototube, which allows the
image field curvature, and distortion with mini-
simple, fast mounting of digital cameras. The technical features of the individual models
mal effort. In all Ivesta 3 Series microscopes
Ivesta 3 (Integrated camera) has USB ports can be found in chapter "Technical Data",
the optimum corrected center of the objective
that allow saving files on USB thumb drive and page 56".
ensures high image quality. This provides supe-
sharing via network and allow image sharing
rior optical performance with large, level and
via Ethernet connection.
undistorted fields of view and chromatically
optimized, high-contrast images.

Ivesta 3 Series User Manual Introduction  14


Microscopes of Ivesta 3 Series

Ivesta 3 Ivesta 3 (C-mount) Ivesta 3 (Integrated camera)

Ivesta 3 Series User Manual Introduction  15


Overview of Ivesta 3 and Ivesta 3 (C-mount)

1. Leica microscope camera (available for


Ivesta 3 (C-mount))
2. C-mount adapter and video/photo tube (in 1
Ivesta 3 (C-mount))
3. Eyepieces 2
4. Adjustable tube: Interpupillary distance
adjustable from 50 to 76 mm
3
5. Fixing screw for optics carrier in the micro-
scope carrier 4
6. Threads for fastening the light arm 8
(both sides and rear)
7. Focusing drive
8. Magnification changer, right drive knob with
magnification scale 7
6 5

Ivesta 3 Series User Manual Introduction  16


Overview of Ivesta 3 (Integrated camera)

1. Integrated camera
2. Eyepieces
3. Adjustable tube: Interpupillary distance
adjustable from 50 to 76 mm
4. Fixing screw for optics carrier in the microscope carrier 1
5. Threads for fastening the light arm
2
(both sides and rear)
6. Focusing drive 3
7. Magnification changer, right drive knob with magnification 7
scale

6
5 4

Ivesta 3 Series User Manual Introduction  17


Overview of Ivesta 3 (Integrated camera) (Continued)

Firmware for Ivesta 3 (Integrated camera) is Enersight On-Screen Display (OSD) Enersight Mobile
constantly being updated. Be sure to keep your Your microscope comes with a dedicated opera- Your microscope can be operated with Mobile
camera up-to-date by checking the download ting system (On-Screen Display menu, OSD Application "Enersight Mobile". Please down-
section on the camera's website. There you will menu) to provide stand-alone functionality. load it free of charge from Google Play or
find new firmware and instructions on how to The user interaction is enabled via an on-screen App Store.
update your camera. You may also contact your display which superimposes a graphical user
Leica representative for help. interface on the microscope image.
For information on the On-Screen Display (OSD)
Real 4K monitor in stand-alone mode, refer to Tutorials or the
The integrated HDMI output allows the micro- OSD User Manual. Google Play Store Apple Store
scope image to be displayed on a high-defini-
tion (HD-capable) monitor, where the following User-friendly even in the smallest detail
Enersight Desktop
resolutions are possible: Ivesta 3 (Integrated camera) reacts differently
Your Ivesta 3 (Integrated camera) includes a
3,840 × 2,160 (4K UHD). To be used on to different light sources. The white balance is
O Quick Start Guide with a download link to the
4K monitors. set to match LED illumination from Leica at the
latest "Enersight Desktop" software.
O 1,920 × 1,080 (Full-HD). This resolution factory.
provides the characteristic imaging perfor- In general, utilization of LED illumination from
mance for a Full-HD-capable monitor. Leica is recommended.

Ivesta 3 Series User Manual Introduction  18


Overview of Ivesta 3 (Integrated camera) (Continued)

The integrated 12-megapixels- Power Ivesta 3 (Integrated camera)


camera has many possibilities for Power can be provided to the microscope in the
various applications and conditions following ways:
of use. O External USB power supply
O USB connection to the PC via USB-C/A cable
In order to keep your camera up to
date and to benefit from newest
functions you should update the
camera's firmware from time to
time. Detailed instructions about
this topic can be found in the down-
load section of Ivesta 3 (Integrated
camera) on our website.

Ivesta 3 Series User Manual Introduction  19


Operating Elements and Connectors of Ivesta 3 (Integrated Camera)

1. ON / OFF button
1 2 3 4 2. Status LED
3. HDMI port for monitor (stand-alone mode)
4. 3× USB port for
– mouse,
– keyboard,
– Wi-Fi dongle or
4 – USB-to-Ethernet adapter (USB Type-A)
4 5. USB SPEED port (insert USB thumb drive for
data storage here) (stand-alone operation)
6. PC / power supply connection
(USB Type-C)

6 5

Ivesta 3 Series User Manual Introduction  20


Standard Delivery and Optional Accessories of Ivesta 3 (Integrated camera)

Standard delivery Optional accessories For information on additional


Standard delivery of Ivesta 3 (Integrated 1. Wi-Fi dongle accessories, such as objectives and
camera) includes: 2. USB-to-Ethernet adapter adapters, illumination or the dust
3. HD/4K monitor cover for the microscope, please
1. Ivesta 3 (Integrated camera)
4. Handswitch/Footswitch contact your Leica Microsystems
2. USB-C/USB-A cable (for PC or power supply
5. Barcode scanner authorized dealer.
connection)
3. USB stick
Wi-Fi dongle
4. 4K HDMI cable, for connecting to an HD/4K monitor
HD/4K monitor The Wi-Fi dongle enables you to work under
HD/4K monitor enables you to life stream and
5. Power supply unit Ivesta 3 (Integrated wireless condition with Ivesta 3 (Integrated
acquire images in a higher resolution.
camera) camera).
Due to different country restrictions, there are
Handswitch/Footswitch
different versions of Wi-Fi dongles available.
Various functionals can be assigned to the opti-
1 To get the latest information about the availa- onal handswitch/footswitch (such as taking
bility of Wi-Fi dongles in your specific country, pictures, white balance, video recording).
please contact your local sales representative.

Barcode scanner
2 3 USB-to-Ethernet adapter
Barcode scanner or Barcode reader enables you
The USB-Ethernet adapter allows you to to assign tags for images and videos.
connect an Ethernet cable to a USB-A port on
the camera to set up a Ethernet network.
4 5

Ivesta 3 Series User Manual Introduction  21


Installation

Ivesta 3 Series User Manual Installation  22


Installing the Camera on Ivesta 3 (C-mount)

Ivesta 3 (C-mount) is equipped with Installing the camera 3. Insert the unit into the video/photo output
an integrated video/phototube, 1. Remove the protective dust cover from the of the stereo microscope and screw it in.
which allows the simple, fast moun- video/projection lens (C-mount adapter)
ting of digital cameras for photos and the microscope camera.
and video. Please ask your Leica
consultant about the options.

NOTICE
X Always close the video/photo output
with the protective dust cover if no
2. Screw the camera into the video/projection
camera is installed.
lens (C-mount).

Ivesta 3 Series User Manual Installation  23


Connectivity of Ivesta 3 (Integrated camera)

Introduction
The Ivesta 3 (Integrated camera) features an integrated and network capable state-of-the-art brightfield microscope with 12 megapixel image resolution.
There are various ways to connect the stereo microscope with your viewing devices:

Stand-alone mode PC mode Network mode

Connect the microscope to HD/4K monitor via Use USB-C/USB-A cable to connect Ivesta 3 Use your microscope in network mode by
HDMI. Connect the USB stick and mouse on the (Integrated camera) to your computer. connecting it to the Ethernet (via adapter) or
back panel. Next, connect the power supply by connecting a Wi-Fi dongle.
unit on the back panel of Ivesta 3 (Integrated
camera).

Ivesta 3 Series User Manual Installation  24


Stand-Alone Mode: General Notes

NOTICE Installing the USB thumb drive NOTICE


The Ivesta 3 (Integrated camera) is designed NOTICE Make sure that the USB thumb drive is
for the use of 4K and HD-capable (high defi- Make sure to read the following instructions oriented correctly before inserting it into the
nition) monitors. We recommend connecting about formatting and handling the USB Ivesta 3 (Integrated camera). If you acciden-
the HD / 4K monitor using an HDMI connec- thumb drive provided in order to prevent tally insert the USB thumb drive the wrong
tor and not using any adapters (e.g. DVI), as malfunctions during image acquisition. way around, this could damage the camera.
otherwise proper function can no longer be
File system and formatting:
guaranteed! X Use a fast USB thumb drive to
exFAT or FAT32 file system is required for the ensure a quick operation.
NOTICE thumb drive to work correctly, as it is detected
Please use only the provided 5 V power by the Ivesta 3 (Integrated camera). Most USB
supply unit. thumb drives are factory-formatted with FAT32
Using another adapter with incorrect voltage so that they can be used immediately.
can substantially damage the camera. If the USB thumb drive is formatted differently,
The Ivesta 3 (Integrated camera) can be powe- the Ivesta 3 (Integrated camera) provides the
ability to reformat as exFAT.
red by the computer via the USB-C / USB-A
cable (PC mode). 1. Press "USB Eject" button but do not remove
the stick.
2. Go to the settings page to format.
During this process all data on the stick are
erased.

Ivesta 3 Series User Manual Installation  25


Stand-Alone Mode: Cables and Terminals

Power supply and HD/4K monitor

Connect Ivesta 3 (Integrated camera):

2 1
1. Use the 4K HDMI cable to connect the HDMI
port (1) of Ivesta 3 (Integrated camera) and
the HD/4K monitor.
2. Use the USB-C/USB-A cable to connect the
port (2) of Ivesta 3 (Integrated camera) to a
suitable power socket.

Ivesta 3 Series User Manual Installation  26


Stand-Alone Mode: Installing USB Thumb Drive

Saving data on the


Ivesta 3 (Integrated camera)

X To ensure the quickest possible way to


store data, insert the USB thumb drive with
sufficient free memory in the USB SPEED
ports (1).

Ivesta 3 Series User Manual Installation  27


Stand-Alone Mode: Installing Wireless USB Mouse

USB Type-A ports on the 1. Plug in the USB transmitter of the USB mouse
Ivesta 3 (Integrated camera): in an unused USB Type-A port (1) on the
Ivesta 3 (Integrated camera).
1
X Do not use the USB SPEED port
as this is required for the USB
thumb drive.

2. Switch on the wireless USB mouse.


The connection between the wireless trans-
mitter and the camera will be arranged
automatically. It is not necessary to "pair"
the devices with each other.

Ivesta 3 Series User Manual Installation  28


PC Mode: Connecting a Computer, Installing Software

Downloading and Installing the soft- Connecting the camera to a computer


ware USB-C port on Ivesta 3 (Integrated camera):
1. Go to Microscope Software Platform Ener-
sight or scan the QR code to be directed to
Enersight web-page:

1
2. After downloading the Enersight Desktop
software, follow the instructions for instal- 1. Connect Ivesta 3 (Integrated camera) to
ling the software. a USB-C port (1) of the computer using a
USB-C/USB-A cable .
The camera is powered by the computer via
the USB-C/USB-A cable.

2. Run Enersight Desktop on your PC.

Ivesta 3 Series User Manual Installation  29


Assembly

Ivesta 3 Series User Manual Assembly  30


Assembling the Optics Carrier and Additional Objective

Optics carrier (76 mm standard) Additional objective (optional) Protective objective glass (optional)
X Insert the optics carrier carefully in the X Screw the desired objective counter clock- X Screw the objective protective glass
microscope carrier and fasten it in the desi- wise into the optics carrier. directly onto the objective.
red position with the clamping screw.

Optical carrier: 76 mm (standard)

Ivesta 3 Series User Manual Assembly  31


Available Optional Graticules

The optional graticules enable Available graticules


measurement and, in addition, The following graticules and objective micro-
provide valuable information when meters for calibrating may be ordered:
comparing and capturing still O Graticule 10 mm/0.1 mm
images of the specimens. Insert O Graticule 5 mm/0.1 mm
the graticule before you set the O Graticule 5 mm/0.05 mm
eye­piece in place. O Graticule 100 Div./0.002"
O Graticule 100 Div./0.001"
O Graticule 150 Div./0.0005"
O Crosshairs
O Stage micrometer 50 mm, 0.1/0.01/ mm
graduation
O Stage micrometer 1", 0.001" graduation

Ivesta 3 Series User Manual Assembly  32


Inserting the Graticules

Graticules can be inserted in the Inserting the graticule(s) 3. Hold the graticule by the edges to avoid
adjustable eyepieces and the in the 1. Use the stereo microscope to determine leaving fingerprints, and push it into the
eyepieces for eyeglass wearers. the side on which the scale is inscribed. The holder from the side.
scale must not appear reversed.
2. Remove the insert from the bottom of the
eyepiece and place it on the bench with the
knurled side down.

4. Replace the insert in the eyepiece and press


it firmly into place.
5. Insert the eyepiece in the tube and turn the
eyepiece in the tube to align the graticule
correctly.

Ivesta 3 Series User Manual Assembly  33


Inserting the Eyepieces

You can use your Ivesta 3 Series Inserting the eyepieces Risk of infection
stereo microscope together with 1. Push eyepieces as far as they will go into Direct contact with eyepieces is a
a fixed or adjustable eyepiece. For the tubes. potential transmission method for
models in which a graticule is inclu- bacterial and viral infection of the
ded in an eyepiece for measurement eye. The risk can be kept to a mini-
or photography, two eyepieces are mum by using personal eyepieces
necessary. for each individual or detachable
eyecups.

2. Check that the eyepieces are seated firmly


and precisely in place.

Ivesta 3 Series User Manual Assembly  34


Operation

Ivesta 3 Series User Manual Operation  35


Using the Eyepieces

The eyepieces form the connection If you do not wear eyeglasses If you wear eyeglasses
between the tube and the eye of the Depending on the preferences of the observer, Eyeglass wearers must remove or
observer. Simply push them into the eyecups can be used. fold back the eyecups (Fig. below
tube and they are ready to use. left), as otherwise they cannot see
WARNING the entire field od view.
Serious injuries caused by eye
infections.
To avoid eye infections, we recom-
mend that every user uses his or her
own pair of eyecups.

10x eyepieces have a fixed circular


What does "parfocal" mean? field of view of 18 mm or more
diameter. The field of view of the
Parfocal" means that a specimen
Ivesta 3 (Integrated camera) is retan-
continues to remain exactly in
gular to ensure an even field on the
focus, even if the magnification on
digital image. As a result, the image
the stereo microscope is modi-
field of the camera is smaller than
fied. All stereo microscopes from
the object field seen through the
Leica Microsystems are parfocally
eyepieces.
matched. However, the parfocality
requires a personal dioptric correc-
tion for the user.

Ivesta 3 Series User Manual Operation  36


Setting the Correct Interpupillary Distance

The interpupillary distance is Reference value Setting the eye distance


correctly set if you see a single The interpupillary distance can be set between 1. Bring the eyes slowly to the eyepieces.
circular image field when looking at 50 and 76 mm.
2. Push the tubes together or apart with both
a specimen. hands until you see a single round, circular
An "exit pupil distance" is the
The interpupillary distance is correctly set if you distance between eye and image field without shadows with both
see a single circular image field when looking eyepiece. With the 10×/23B wide- eyes.
at a specimen. field eyepiece for eyeglass wearers,
it is approx. 22 mm. For those who
do not use the eyepiece for eyeglass
wearers, it is 12 mm.

 

Ivesta 3 Series User Manual Operation  37


Changing Magnification (Zooming)

All stereo microscopes of Ivesta 3 Changing magnification


Series allow a continuous magnifi- 1. Look into the eyepieces.
cation change. The magnification 2. Focus on the object.
changer can be operated with the
left and the right hand. The image 3. Rotate the magnification changer until the
scale is shown on the right drive desired magnification is configured.
knob.

The basis for the calculation of the


total magnification and the field of
view can be found in chapter "Calcu-
lating the Total Magnification/Field
of View Diameter", page 63.

Ivesta 3 Series User Manual Operation  38


Regulating the Resistance of the Focusing Drive

Adjusting the resistance


Is the focusing drive too loose or too tight? Does
the equipment tend to slide downwards? The
resistance can be adjusted individually depen-
ding on the equipment weight and personal
preferences as follows:
X Grip the outer drive knobs with both hands
and turn them towards each other until the
desired resistance is reached during focu-
sing.

Ivesta 3 Series User Manual Operation  39


Changing the Position of the Optics Carrier

The optics carrier can be turned Changing position


sideways in the microscope carrier 1. Unscrew the clamping screw.
if the user wants to work from the
side.

2. Turn the optics carrier laterally to the desi-


red position.​

3. Carefully tighten the clamping screw.

Ivesta 3 Series User Manual Operation  40


Switching on Ivesta 3 (Integrated camera)

Stand-alone mode X Set the ON / OFF button (1) to "ON" to Network mode
ON / OFF button on Ivesta 3 (Integrated switch on Ivesta 3 (Integrated camera). 1. Set the ON / OFF button (1) to "ON" to
camera): The camera automatically detects the switch on Ivesta 3 (Integrated camera).
HD/4K monitor and run Enersight On-Screen- 2. Refer to page 44 to page 46 for more
1
Display. guidance.

PC mode
1. Set the ON / OFF button (1) to "ON" to
switch on Ivesta 3 (Integrated camera).
The camera is ready to use.

2. Start the Enersight Desktop software.

Ensure the following points: For additional information on Ener-


sight Desktop, refer to the website
O The microscope is connected to
Microscope Software Platform
a HD/4K monitor and the power
Enersight.
supply.

Ivesta 3 Series User Manual Operation  41


Operation in Stand-Alone Mode

For information on setting


up and switching on the
Ivesta 3 (Integrated camera) in
stand-alone mode, refer to chapter
"Switching on Ivesta 3 (Integrated
camera)" subchapter "Stand-alone
mode", page 41.

For information on working with the


OSD menu, refer to Tutorials or the
OSD User Manual.

Ivesta 3 Series User Manual Operation  42


Operation in PC Mode

For information on setting Additional parallel use of a HD/4K Connecting the HD/4K monitor
up and switching on monitor X Use the HDMI cable to connect the
Ivesta 3 (Integrated camera) in PC HDMI port (1) of Ivesta 3 (Integrated
mode, refer to chapters: General notes camera) and the HD/4K monitor.
When connected to a computer, the HDMI port on Ivesta 3 (Integrated camera):
O "PC Mode: Connecting a
microscope image is always shown
Computer, Installing Software", 1
in the preview window of Ener-
page 29
sight Desktop. To display a 4K live
O "Switching on Ivesta 3 (Inte-
image at up to 60 fps in PC mode,
grated camera)", page 41,
please connect an optional 4K and
subchapter "PC mode"
HD-capable monitor to the HDMI
port of the microscope.

The resolution on the connected


HD/4K monitor is always a 16:9
format and independent of the
computer resolution.

Additionally the on-screen display


(OSD) functionality is turned off on
the HDMI monitor.

Ivesta 3 Series User Manual Operation  43


Operation in Network Mode

For information on setting up and For using the Enersight Mobile App with your USB ports on Ivesta 3 (Integrated camera):
switching on Ivesta 3 (Integrated Ivesta 3 (Integrated camera), please download
it via Google Play or App Store. 1
camera) in network mode, refer to
chapter:
O "Switching on Ivesta 3 (Inte-
grated camera)", page 41,
subchapter "Network mode"

For information on working with


Ivesta 3 (Integrated camera) in the Google Play App Store
network mode on the OSD menu,
refer to Tutorials or the OSD User
Manual. Connecting to the network
You can connect to the network with the Wi-Fi
dongle or with the USB-to-Ethernet adapter.
X Plug in the Wi-Fi dongle or the USB-to-
Ethernet adapter to the USB port (1) on the
back panel.

Ivesta 3 Series User Manual Operation  44


Operation in Network Mode (Continued)

Network configuration 5. Download Enersight Mobile on your smart- Your Ivesta 3 (Integrated camera) is
To set up network configuration refer to Tutori- phone or tablet from Google Play or App connected to a network – Client-Mode
als or the OSD User Manual. Store (see page 44).
1. Activate this mode on Enersight OSD as
To connect your mobile device (smartphone
follows:
Connection to the mobile device or tablet), you can choose between 2 different
modes: Settings Ú Network Ú Client-Mode
First connection:
1. Run Ivesta 3 (Integrated camera) in a 2. Select a network you would like to connect.
Your Ivesta 3 (Integrated camera) serves
stand-alone mode (page 41).
as an Access Point (AP) 3. Enter the password.
2. Go to the network settings in the Enersight
4. Connect your mobile device to the same
On-Screen-Display software as follows: 1. Activate this mode on Enersight OSD as
network.
follows:
Enersight OSD Ú Settings Ú Network
In "Settings" on Enersight OSD you will see
Settings Ú Network Ú AP-Mode
an IP adress of your camera.
3. Activate WebSocket and create the certifi-
cate. You will see the credentials of this AP (SSID,
password, etc.) and IP address of the device.
4. Restart Ivesta 3 (Integrated camera).

Perform this step only once during 2. Connect your mobile device to this AP (via
the initial setup. Settings on your smartphone/tablet).

Ivesta 3 Series User Manual Operation  45


Operation in Network Mode (Continued)

Accessing the device from your Mobile Subsequent connections


App
1. Turn on Ivesta 3 (Integrated camera).
1. Open your Enersight Mobile App.
1. Either connect your smartphone or tablet
2. Click on “Setting” icon in the tab “Device”. to the Access Point (see page 45) of
Ivesta 3 (Integrated camera) or to the
3. Enter the IP address of the camera and click
network Ivesta 3 (Integrated camera) is
“Connect”.
already connected to (depending on the
Ivesta 3 (Integrated camera) is connected mode you used before).
to your mobile device.
2. Open the Enersight Mobile App on your
mobile device and go to Settings.
To switch from one mode to
another, the Wi-Fi button on the 3. Click on the latest IP address in the history
Enersight OSD must be disabled. list.
Ivesta 3 (Integrated camera) is connected.

Ivesta 3 Series User Manual Operation  46


Troubleshooting

Ivesta 3 Series User Manual Troubleshooting 47


Troubleshooting

Stand-alone operation How to reset the


If the Ivesta 3 (Integrated camera) is configu- Ivesta 3 (Integrated camera)?
red for 4K resolution and attached to a Full- 1. Power the microscope off.
HD monitor with only 1,080 p resolution, the
2. Unplug the USB mouse.
microscope should detect this and switch auto-
matically to the necessary resolution. 3. Restart the microscope.
The Ivesta 3 (Integrated camera) will
However, if no image appears and the screen
restart in Full-HD 1,080 p mode and a live
reports an error message like "out of range"
image will appear.
or something similar, you can reset the micro-
scope resolution to 1,080 p. 4. Plug in the USB mouse again and configure
the correct live image resolution.

Ivesta 3 Series User Manual Troubleshooting 48


Recovery Mode

At every startup the microscope checks whether


the application image is valid. In case the image
is corrupted, e.g. by an interrupted firmware
update, the Ivesta 3 (Integrated camera) swit-
ches into a recovery mode.

RECOVERY MODE
Starting up the fallback system.....

After 12 seconds the system asks for the firm-


ware file which should be stored on the USB
flash drive.

RECOVERY MODE
Please insert an USB flash drive with
the latest firmware. Download the
latest firmware from
www.leica-microsystems.com.

X Please make sure the USB stick is inserted in


the speed port so the system will automati-
cally install the provided firmware.

Ivesta 3 Series User Manual Troubleshooting 49


Care and Maintenance

Ivesta 3 Series User Manual Care and Maintenance  50


Care, Maintenance, Contact Persons

General Care X Do not disassemble or replace plugs, opti-


We hope you enjoy using your high-perfor- X Keep all optical components clean for cal systems and mechanical parts, unless
mance microscope. Leica microscopes are maintaining good optical performance. doing so is specifically permitted and
renowned for their robustness and long service described in this user manual.
X If any optical surface becomes badly coated
life. Observing the following care and clean- X Protect your microscope from oil and
with dust or dirt brush it off with a camel
ing tips will ensure that even after years and grease.
hair brush before attempting to wipe it
decades, your Leica microscope will continue to
clean. X Do not grease guide surfaces or mechanical
work as well as it did on the very first day.
X Clean optical surfaces by using a lint-free parts.
cloth, lens cloth or cotton swab soaked in
Warranty benefits
70 % ethanol or a commercially available Protection from dirt
The guarantee covers all faults in materials glass cleaner. Do not use pure alcohol.
and manufacture. It does not, however, cover Dust and dirt will affect the quality of your
damage resulting from careless or improper X Avoid excessive use of solvents. The lint- results.
handling. free cloth, lens cloth or cotton swab should
X Put an otionally available dust cover over
only be lightly moistened with solvent.
the microscope when it will not be used for
Contact address X Protect your microscope from moisture, a long time.
fumes and acids and from alkaline, caustic
If your microscope no longer works perfectly, X Keep accessories in a dust-free place when
and corrosive materials and keep chemicals
contact your Leica representative. not in use.
away from the microscope and its accesso-
ries.

Ivesta 3 Series User Manual Care and Maintenance  51


Care, Maintenance, Contact Persons (Continued)

Cleaning polymer components Permitted measures WARNING


Some components are made of polymer or are X Remove dust on the filter glass with a Danger of electric shock.
polymer-coated. The use of unsuitable cleaning bellows and a soft paintbrush.
Risk of electric shock. Removing the
agents and techniques can damage polymers.
X Clean the objectives with special optics cover of Ivesta 3 (Integrated camera)
cleaning cloths and pure alcohol. exposes electrically live parts, which,
if touched, can cause potentially
Servicing fatal injuries. Have technical service
carried out by a Leica Microsystems
X Ensure that repairs are only be carried out
authorized dealer.
by Leica Microsystems-trained service tech-
nicians. Only original Leica Microsystems
spare parts may be used.

Ivesta 3 Series User Manual Care and Maintenance  52


Specifications

Ivesta 3 Series User Manual Specifications 53


Spare Parts

Item Leica article number Designation Ivesta 3 Ivesta 3 Ivesta 3


(Integrated (C-mount)
camera)
1 10726960 USB-C/A cable ×
2 10726961 USB Thumbdrive 64 GB ×
3 10726529 HDMI cable 2 m ×
4 10726962 USB power supply ×
5 10726783 USB dummy plug in ×
6 10726785 HDMI dummy plug in ×
7 10640643 Cap for C-mount ×
8 10725987 Lens shield × × ×

Ivesta 3 Series User Manual Specifications 54


Optional Sales Items

Item Leica article number Designation


1 12730524 Wi-Fi Adapter 5 GHz (US)
2 12730557 Wi-Fi Adapter 5 GHz (EU)
3 12730559 Wi-Fi Adapter 2.4 GHz (EU)
4 12730601 USB-to-Ethernet Adapter
5 10450961 USB Barcode Reader
6 12730359 USB Footswitch
7 10450859 4K HDMI Monitor

Ivesta 3 Series User Manual Specifications 55


Technical Data

Characteristics Ivesta 3 Ivesta 3 (C-mount) Ivesta 3 (Integrated camera)


Optical system, lead-free 10° Greenough using best-corrected central part of the objective
Zoom 9:1
Viewing angle 35°
Magnification range* 6.1× - 55×
Maximum resolution 500 lp/mm
Maximum numerical aperture 0.167
Working distance* 122 mm
Object field diameter* 37.6 mm
Adjustable zoom limits* Click-stops: 10×, 20×, 30×, 40×, 50× Fully coded zoom
Video / photo outlet _ 50 % Video, 50 % visual, 50 % Video, 50 % visual,
permanent permanent
Weight (camera only) 1.6 kg 1.8 kg 2.2 kg
Standard objectives, lead-free Apochromats: 0.5×, 0.63×, 0.75×, .1.6×, 2.0×
Ergonomic eyepieces, fixed and adjustable, 10× / 23, 16× / 16, 20× / 12
with cups
Ergonomic eyepieces for eyeglass wearers, 10× / 23, 16× / 15,
adjustable, with eyecups 25× / 9.5, 40×/ 6
Interpupillary distance* 50–76 mm
* Values with basic outfit (no supplementary lens, 10×/23 eyepieces)

Ivesta 3 Series User Manual Specifications 56


Technical Data (Continued)

Characteristics Ivesta 3 Ivesta 3 (C-mount) Ivesta 3 (Integrated camera)

Operating temperature 10° C to 40° C (50° F to 104° F)


Storage / Transport temperature -10° C to 50° C (14° F to 122° F)
Relative humidity for storage / operation 10 % to 90 % (non-condensing)
Use For indoor use only
Pollution degree 2
Altitude operation 0 m to 2,000 m (0 ft to 6,561 ft)
Live image on an HDMI monitor N/A N/A at up to 60 fps
(3,840 × 2,160 pixels)
Full-screen image capture at 12 MP
Sensor diagonal 7.81 mm (type 1/2.3" CMOS)
Pixel size 1.55 μm × 1.55 μm
Input 5 V DC / 3 A
Power consumption 15 W
Supported software Enersight
Color filter IR-cut coating 650 nm, not
replaceable
File formats JPG, TIF, BMP, MJPG; for overlays
also PNG
Compatibility USB 3.0, standard USB type C

Ivesta 3 Series User Manual Specifications 57


Technical Data (Continued)

Housing
Characteristics Ivesta 3 Ivesta 3 (C-mount) Ivesta 3 (Integrated camera) Characteristics Value
HD connector N/A N/A HDMI 2.0a, HDMI plug type A Material PC/ABS
USB Connectors N/A N/A 4× USB 2 connectors, type A Antimicrobial AgTreatTM
ON / OFF Button N/A N/A 1× (on rear side of the microscope) surface according to ISO 22196
Multicolor status LED N/A N/A 1× (on rear side of the microscope) Protection rating IP 41

Power supply unit (only applicable to Ivesta 3 (Integrated Camera))

Characteristics Value
Manufacturer Sinpro Electronics Co., Ltd., 18F, NO.80, Minzu 1st Rd., Sanmin District, Kaohsiung City 807, Taiwan
Model identification SPU25A-102
Input voltage 90–264 V AC
Input frequency 47–63 Hz
Output voltage 5 V DC
Output current max. 3.3 A
Output power max. 16.5 W
Average active efficiency 82.5 %
Efficiency at high load (10 %) 79.5 %
No-load power consumption 0.014 W

58
Dimensional Drawings Ivesta 3

Dimensions in mm

Ivesta 3 Series User Manual Specifications 59


Dimensional Drawings Ivesta 3 (C-mount)

Dimensions in mm

Ivesta 3 Series User Manual Specifications 60


Dimensional Drawings Ivesta 3 (Integrated camera)

Dimensions in mm

Ivesta 3 Series User Manual Specifications 61


Appendix

Ivesta 3 Series User Manual Appendix  62


Calculating the Total Magnification/Field of View Diameter

Parameter Example
MO Magnification of the additional objective MO Additional objective 1.6×
ME Magnification of eyepiece ME 20×/12 eyepiece
z Magnification changer position z Zoom position 4.0
NFOV Field number of the eyepiece. Field numbers are printed on
the eyepieces: 10×/23, 16×/16, 20×/12, 10×/23B, 16×14B,
25×/9.5B, 40×6B.

Magnification in the binocular tube Calculation example: Field of view diameter in the specimen

M = MO × ME × z
TOT VIS N 12
or ∅ OF: FOV = = 1.9 mm
M ×z 1.6 ×4
1.6 × 20 × 4 = 128 O

Ivesta 3 Series User Manual Appendix  63


Subject to modifications. LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH.
05/2023 · Doc. 10727094 · © 2023 by Leica Microsystems GmbH.

CONNECT
WITH US!

Leica Microsystems (Schweiz) AG · Max-Schmidheiny-Strasse 201 · 9435 Heerbrugg, Switzerland


T +41 71 726 34 34 · F +41 71 726 34 44

www.leica-microsystems.com

You might also like