Technical specification
Curves according to: Wastewater. Wastewater. [100%],40 °C,1005 kg/m³,1 mm²/s
[m] Head
48
46
44
42
40
38 38%
36 44%
50%
34
55%
32
30 60%
28
1
26
Eff.
24 62%
22
64%
20
61.8%
18 55%
16 61.7% 50%
14 245 180mm
59% 246 173mm
12
10
8
6 249 146mm
4
2
0
0 10 20 30 40 50 60 70 80 90 100 [m³/h]
Curve: ISO 9906
Nominal (mean) data shown. Under- and over-performance from this data should
Configuration
be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Inlet diameter
90 mm
Number of blades
2
Motor - Technical
Power factor - 1/1 Load Motor efficiency - 1/1 Load Total moment of inertia Starts per hour max.
0.89 87.3 % 0.0186 kg m² 30
Power factor - 3/4 Load Motor efficiency - 3/4 Load Starting current, direct starting
0.86 88.2 % 114 A
Power factor - 1/2 Load Motor efficiency - 1/2 Load Starting current, star-delta
0.78 87.7 % 38 A
45°
M12 (4x)
Ø180
33
612
114
DN80
DN100
519
209
159
67
183
20°
227
Weight (kg)
Pump
147
NX,FX 3127 SH
Discharge
outlet
Pump outlet DN 80
Scale
1:10 201125
Date