You are on page 1of 13

CP 3531/905 3~ 840

Shrouded single or mul -channel impeller pumps with large throughlets


and single volute pump casing for liquids containing solids and fibres.
Cast iron design with double sealing technology. Some models
available as stainless steel versions.

Technical specifica on
Curves according to: Water Water [100%],4 °C,0.99994 kg/dm³,1.569 mm²/s
[m]
Head
52
50
48
46
44
42
40
38
36
34
32
30
28 86.1%
26
24
22
20
18
16
14
840 620mm
12
10
8
6
4
2
0
0 1000 2000 3000 4000 5000 [m³/h]
Curve: ISO 9906
Nominal (mean) data shown. Under- and over-performance from this data should
be expected due to standard manufacturing tolerances.
Configuration Please consult your local Flygt representative for performance guarantees.

Motor number Installa on type


C0905.000 66-56-8AD-W IE3 P - Semi permanent, Wet
525hp
Impeller diameter Discharge diameter
620 mm 500 mm

Pump information Material


Impeller diameter Impeller
620 mm Stainless steel

Discharge diameter
500 mm

Inlet diameter
600 mm

Maximum opera ng speed


895 1/min

Number of blades
3

Throughlet diameter
105 mm

Max. fluid temperature


40 °C

Project 200MLD Putatan WTP_R1 Created by Chen, Oichin


Block 0 Created on 2/16/2024 Last update 2/27/2024 Page 66 / 78

Program version Data version User group(s)


72.0 - 2/20/2024 (Build 175) 1/30/2024 2:24 PM Xylem: China - INT, Malaysia - INT
CP 3531/905 3~ 840
Technical specifica on
Motor - General
Motor number Phases Rated speed Rated power
C0905.000 66-56-8AD-W IE3 3~ 895 1/min 391 kW
525hp
Approval Number of poles Rated current Stator variant
No 8 610 A 38

Frequency Rated voltage Insula on class Type of Duty


60 Hz 460 V H S1
Version code Direct media cooling system
000

Motor - Technical
Power factor - 1/1 Load Motor efficiency - 1/1 Load Total moment of inertia Starts per hour max.
0.85 95.4 % 31.3 kg m² 10

Power factor - 3/4 Load Motor efficiency - 3/4 Load Starting current, direct starting
0.83 95.8 % 3140 A

Power factor - 1/2 Load Motor efficiency - 1/2 Load Starting current, star-delta
0.78 95.6 % 1050 A

Project 200MLD Putatan WTP_R1 Created by Chen, Oichin


Block 0 Created on 2/16/2024 Last update 2/27/2024

Program version Data version User group(s)


72.0 - 2/20/2024 (Build 175) 1/30/2024 2:24 PM Xylem: China - INT, Malaysia - INT
CP 3531/905 3~ 840
Performance curve
Duty point
Flow Head
3580 m³/h 28 m

Curves according to: Water Water [100%],4 °C,0.99994 kg/dm³,1.569 mm²/s


[m]
Head
52
50
48
46
44
42
40
38
36
34
32
30
28 86.1% 28 m
26
24
22
20
18
16
14
840 620mm
12
10
8
6
4
2
0 86.1 %
[%] Efficiency
80 Overall efficiency 82.5 %
70
60 840 620mm
840 620mm
50
40
30
20
10
[kW]0
Power input P1 331.2 kW
320 Shaft power P2 840
840 620mm
620mm (P1)
(P2)317.3 kW
280
240
200
160
120
80
40
0
NPSH-values 840 620mm
[m]
14
12
10
NPSHR = 10 m
8 8.24 m

6
3577.1 m³/h
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 4800 5200 5600 [m³/h]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees. Curve: ISO 9906
200MLD Putatan WTP_R1 Chen, Oichin
0 Created on 2/16/2024 Last update 2/27/2024

Program version Data version User group(s)


72.0 - 2/20/2024 (Build 175) 1/30/2024 2:24 PM Xylem: China - INT, Malaysia - INT
CP 3531/905 3~ 840
Duty Analysis

Curves according to: Water, pure [100%] ; 4°C; 0.99994kg/dm³; 1.569mm²/s


[m]
Head
52
50
48
46
44
42
40
38
36
34
32
30
28 86.1% 28 m
26
24
22
20
86.1%
18
16
86.1%
14
840 620mm [Pump 1] 840 620mm [Pump 1+2] 840 620mm [Pump 1+2+3]
12
840 620mm [Pump 1+...+4]
10
50 Hz 50 Hz 50 Hz 50 Hz
8
45 Hz 45 Hz 45 Hz 45 Hz
6
4
2
14309 m³/h
0
0 4000 8000 12000 16000 20000 [m³/h]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating characteristics
Pumps / Flow Head Shaft power Flow Head Shaft power Hydr.eff. Spec. Energy NPSHre
Systems
m³/h m kW m³/h m kW kWh/l m
4 / 1 3580 28 317 14300 28 1270 86.1 % 9.26E-5 8.24
3 / 1 4200 23.7 322 12600 23.7 967 84.1 % 8.01E-5 9.35
2 / 1 4910 17.8 314 9810 17.8 629 75.6 % 6.68E-5 12.7

Project Created by Chen, Oichin


Block 200MLD Putatan WTP_R1 Created on 2/16/2024 Last update 2/27/2024

Program version Data version User group(s)


72.0 - 2/20/2024 (Build 175) 1/30/2024 2:24 PM Xylem: China - INT, Malaysia - INT
CP 3531/905 3~ 840
Duty Analysis

Curves according to: Water, pure [100%] ; 4°C; 0.99994kg/dm³; 1.569mm²/s


[m]
Head
52
50
48
46
44
42
40
38
36
34
32
30
28 86.1% 28 m
26
24
22
20
86.1%
18
16
86.1%
14
840 620mm [Pump 1] 840 620mm [Pump 1+2] 840 620mm [Pump 1+2+3]
12
840 620mm [Pump 1+...+4]
10
50 Hz 50 Hz 50 Hz 50 Hz
8
45 Hz 45 Hz 45 Hz 45 Hz
6
4
2
14309 m³/h
0
0 4000 8000 12000 16000 20000 [m³/h]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating characteristics
Pumps / Flow Head Shaft power Flow Head Shaft power Hydr.eff. Spec. Energy NPSHre
Systems
m³/h m kW m³/h m kW kWh/l m
1 / 1

Project Created by Chen, Oichin


Block 200MLD Putatan WTP_R1 Created on 2/16/2024 Last update 2/27/2024

Program version Data version User group(s)


72.0 - 2/20/2024 (Build 175) 1/30/2024 2:24 PM Xylem: China - INT, Malaysia - INT
CP 3531/905 3~ 840
VFD Curve

Curves according to: Water ,4 °C,0.99994 kg/dm³,1.569 mm²/s


[m]
Head
52
50
48
46
44
42
40
38
36
34
32
30
28 86.1%
26
24
22
20
18 86.1%
16
86.1%
14
12 840 620mm [Pump 1] 840 620mm [Pump 1+2] 840 620mm [Pump 1+2+3]
840 620mm [Pump 1+...+4]
10
8 50 Hz 50 Hz 50 Hz 50 Hz
45 Hz 45 Hz 45 Hz 45 Hz
6
4
2
0
[%] Efficiency
80 Overall efficiency
70
60 45
4550
Hz
HzHz
50 840
840 620mm
Hz 620mm 45
[Pump
Hz
50
50 Hz
[Pump
45 Hz 1]
1] 840
Hz 840 620mm
45
45 Hz
Hz 50
620mm [Pump
Hz
Hz 1+2]
[Pump
50 1+2] 840
45
45 Hz
840 620mm
50
50 Hz
620mm
Hz [Pump
[Pump 1+2+3]
Hz 1+2+3]
50 840 620mm
840 620mm [Pump
[Pump 1+...+4]
1+...+4]
40
30
20
10
[kW]0
Power input P1
1200 Shaft power P2 840
840 620mm
620mm [Pump
[Pump 1+...+4]
1+...+4] (P1)
(P2)
1000 840
840 620mm
620mm [Pump
[Pump 1+2+3]
1+2+3] (P1)
(P2)
800
50 Hz
50 Hz
600 840 620mm [Pump 1+2] (P1)
(P2)
50 Hz 45 Hz
400 50 Hz 45 Hz
840 620mm 45
[Pump
Hz 1] (P1)
(P2)
200
4550
HzHz
0
NPSH-values 840 620mm [Pump 1] 840 620mm [Pump 1+2]840 620mm [Pump 1+2+3]
[m]
840 620mm [Pump 1+...+4]
14
12 50 Hz 50 Hz 50 Hz 50 Hz
10 45 Hz 45 Hz 45 Hz 45 Hz
NPSHR = 10 m
8
6
4
0 4000 8000 12000 16000 20000 [m³/h]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances. Curve: ISO 9906
Please consult your local Flygt representative for performance guarantees.
Project 200MLD Putatan WTP_R1 Created by Chen, Oichin
Block 0 Created on 2/16/2024 Last update 2/27/2024 Page 71 / 78

Program version Data version User group(s)


72.0 - 2/20/2024 (Build 175) 1/30/2024 2:24 PM Xylem: China - INT, Malaysia - INT
CP 3531/905 3~ 840
VFD Analysis

Curves according to: Water, pure [100%] ; 4°C; 0.99994kg/dm³; 1.569mm²/s


[m]
Head 1Specific energy
52 [kWh/l]
50
48
46
44 9.26E-5 kWh/l
42
40
38
36
34
32
30
28 86.1% 28 m
5.79E-5 kWh/l
26
24
22
20
86.1%
18
16
86.1%
14
840 620mm [Pump 1] 840 620mm [Pump 1+2] 840 620mm [Pump 1+2+3]
12
840 620mm [Pump 1+...+4]
10
50 Hz 50 Hz 50 Hz 50 Hz
8
45 Hz 45 Hz 45 Hz 45 Hz
6
4
2 9507.7 m³/h
45 Hz 14309 m³/h
0
0 4000 8000 12000 16000 20000 [m³/h]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating Characteristics
Pumps / Frequency Flow Head Shaft power Flow Head Shaft power Hydr.eff. Specific energy NPSHre
Systems
m³/h m kW m³/h m kW kWh/l m
4 / 1 60 Hz 3580 28 317 14300 28 1270 86.1 % 9.26E-5 8.24
4 / 1 50 Hz 2790 20.5 181 11200 20.5 725 86 % 6.8E-5 6.07
4 / 1 45 Hz 2380 17.2 130 9510 17.2 522 85.6 % 5.79E-5 5.11

Project 200MLD Putatan WTP_R1 Created by Chen, Oichin


Block 0 Created on 2/16/2024 Last update 2/27/2024 Page 72 / 78

Program version Data version User group(s)


72.0 - 2/20/2024 (Build 175) 1/30/2024 2:24 PM Xylem: China - INT, Malaysia - INT
CP 3531/905 3~ 840
VFD Analysis

Curves according to: Water, pure [100%] ; 4°C; 0.99994kg/dm³; 1.569mm²/s


[m]
Head 1Specific energy
52 [kWh/l]
50
48
46
44 9.26E-5 kWh/l
42
40
38
36
34
32
30
28 86.1% 28 m
5.79E-5 kWh/l
26
24
22
20
86.1%
18
16
86.1%
14
840 620mm [Pump 1] 840 620mm [Pump 1+2] 840 620mm [Pump 1+2+3]
12
840 620mm [Pump 1+...+4]
10
50 Hz 50 Hz 50 Hz 50 Hz
8
45 Hz 45 Hz 45 Hz 45 Hz
6
4
2 9507.7 m³/h
45 Hz 14309 m³/h
0
0 4000 8000 12000 16000 20000 [m³/h]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating Characteristics
Pumps / Frequency Flow Head Shaft power Flow Head Shaft power Hydr.eff. Specific energy NPSHre
Systems
m³/h m kW m³/h m kW kWh/l m
3 / 1 60 Hz 4200 23.7 322 12600 23.7 967 84.1 % 8.01E-5 9.35
3 / 1 50 Hz 3270 17.8 186 9820 17.8 558 85.4 % 5.95E-5 6.5
3 / 1 45 Hz 2780 15.3 135 8340 15.3 404 86 % 5.11E-5 5.28

Project 200MLD Putatan WTP_R1 Created by Chen, Oichin


Block 0 Created on 2/16/2024 Last update 2/27/2024 Page 73 / 78

Program version Data version User group(s)


72.0 - 2/20/2024 (Build 175) 1/30/2024 2:24 PM Xylem: China - INT, Malaysia - INT
CP 3531/905 3~ 840
VFD Analysis

Curves according to: Water, pure [100%] ; 4°C; 0.99994kg/dm³; 1.569mm²/s


[m]
Head 1Specific energy
52 [kWh/l]
50
48
46
44 9.26E-5 kWh/l
42
40
38
36
34
32
30
28 86.1% 28 m
5.79E-5 kWh/l
26
24
22
20
86.1%
18
16
86.1%
14
840 620mm [Pump 1] 840 620mm [Pump 1+2] 840 620mm [Pump 1+2+3]
12
840 620mm [Pump 1+...+4]
10
50 Hz 50 Hz 50 Hz 50 Hz
8
45 Hz 45 Hz 45 Hz 45 Hz
6
4
2 9507.7 m³/h
45 Hz 14309 m³/h
0
0 4000 8000 12000 16000 20000 [m³/h]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating Characteristics
Pumps / Frequency Flow Head Shaft power Flow Head Shaft power Hydr.eff. Specific energy NPSHre
Systems
m³/h m kW m³/h m kW kWh/l m
2 / 1 60 Hz 4910 17.8 314 9810 17.8 629 75.6 % 6.68E-5 12.7
2 / 1 50 Hz 3830 14.2 185 7660 14.2 370 80.4 % 5.06E-5 8.13
2 / 1 45 Hz 3260 12.7 136 6510 12.7 272 83 % 4.4E-5 6.19

Project 200MLD Putatan WTP_R1 Created by Chen, Oichin


Block 0 Created on 2/16/2024 Last update 2/27/2024 Page 74 / 78

Program version Data version User group(s)


72.0 - 2/20/2024 (Build 175) 1/30/2024 2:24 PM Xylem: China - INT, Malaysia - INT
CP 3531/905 3~ 840
VFD Analysis

Curves according to: Water, pure [100%] ; 4°C; 0.99994kg/dm³; 1.569mm²/s


[m]
Head 1Specific energy
52 [kWh/l]
50
48
46
44 9.26E-5 kWh/l
42
40
38
36
34
32
30
28 86.1% 28 m
5.79E-5 kWh/l
26
24
22
20
86.1%
18
16
86.1%
14
840 620mm [Pump 1] 840 620mm [Pump 1+2] 840 620mm [Pump 1+2+3]
12
840 620mm [Pump 1+...+4]
10
50 Hz 50 Hz 50 Hz 50 Hz
8
45 Hz 45 Hz 45 Hz 45 Hz
6
4
2 9507.7 m³/h
45 Hz 14309 m³/h
0
0 4000 8000 12000 16000 20000 [m³/h]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating Characteristics
Pumps / Frequency Flow Head Shaft power Flow Head Shaft power Hydr.eff. Specific energy NPSHre
Systems
m³/h m kW m³/h m kW kWh/l m
1 / 1 60 Hz
1 / 1 50 Hz 4330 10.5 178 4330 10.5 178 69.4 % 4.3E-5 11.2
1 / 1 45 Hz 3680 9.98 133 3680 9.98 133 75.6 % 3.8E-5 8.03

Project 200MLD Putatan WTP_R1 Created by Chen, Oichin


Block 0 Created on 2/16/2024 Last update 2/27/2024

Program version Data version User group(s)


72.0 - 2/20/2024 (Build 175) 1/30/2024 2:24 PM Xylem: China - INT, Malaysia - INT
CP 3531/905 3~ 840
VFD Analysis

Curves according to: Water, pure [100%] ; 4°C; 0.99994kg/dm³; 1.569mm²/s


[m]
Head 1Specific energy
52 [kWh/l]
50
48
46
44 9.26E-5 kWh/l
42
40
38
36
34
32
30
28 86.1% 28 m
5.79E-5 kWh/l
26
24
22
20
86.1%
18
16
86.1%
14
840 620mm [Pump 1] 840 620mm [Pump 1+2] 840 620mm [Pump 1+2+3]
12
840 620mm [Pump 1+...+4]
10
50 Hz 50 Hz 50 Hz 50 Hz
8
45 Hz 45 Hz 45 Hz 45 Hz
6
4
2 9507.7 m³/h
45 Hz 14309 m³/h
0
0 4000 8000 12000 16000 20000 [m³/h]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating Characteristics
Pumps / Frequency Flow Head Shaft power Flow Head Shaft power Hydr.eff. Specific energy NPSHre
Systems
m³/h m kW m³/h m kW kWh/l m

Project 200MLD Putatan WTP_R1 Created by Chen, Oichin


Block 0 Created on 2/16/2024 Last update 2/27/2024 Page 76 / 78

Program version Data version User group(s)


72.0 - 2/20/2024 (Build 175) 1/30/2024 2:24 PM Xylem: China - INT, Malaysia - INT
CP 3531/905 3~ 840
VFD Analysis

Curves according to: Water, pure [100%] ; 4°C; 0.99994kg/dm³; 1.569mm²/s


[m]
Head 1Specific energy
52 [kWh/l]
50
48
46
44 9.26E-5 kWh/l
42
40
38
36
34
32
30
28 86.1% 28 m
5.79E-5 kWh/l
26
24
22
20
86.1%
18
16
86.1%
14
840 620mm [Pump 1] 840 620mm [Pump 1+2] 840 620mm [Pump 1+2+3]
12
840 620mm [Pump 1+...+4]
10
50 Hz 50 Hz 50 Hz 50 Hz
8
45 Hz 45 Hz 45 Hz 45 Hz
6
4
2 9507.7 m³/h
45 Hz 14309 m³/h
0
0 4000 8000 12000 16000 20000 [m³/h]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating Characteristics
Pumps / Frequency Flow Head Shaft power Flow Head Shaft power Hydr.eff. Specific energy NPSHre
Systems
m³/h m kW m³/h m kW kWh/l m

Project 200MLD Putatan WTP_R1 Created by Chen, Oichin


Block 0 Created on 2/16/2024 Last update 2/27/2024 Page 77 / 78

Program version Data version User group(s)


72.0 - 2/20/2024 (Build 175) 1/30/2024 2:24 PM Xylem: China - INT, Malaysia - INT
CP 3531/905 3~ 840
Dimensional drawing

1230

3" Guide bars


30
135 1125
550 225

DN 500

L
min 535
105
840

665

65

1170

Z Z

15°

50
2700
Ref. line 1930
30
570
750

VIEW 670
350

Z-Z 510
Weight (kg)
Drive unit Motor L
Pump Discharge
700

66-46-XX 4850
905/915 2705
66-56-XX 5050
Outlet center line

520
800 Ø24 (4X) 66-46-XX 5050
906/916 2725
66-56-XX 5250
Discharge Scale Date
outlet DN 500
CP 3531 Pump outlet
DN 500 1:40 200622
Pump inlet Drawing number Revision

905,915,906,916 Suction inlet 8415000 1

Project 200MLD Putatan WTP_R1 Created by Chen, Oichin


Block 0 Created on 2/16/2024 Last update 2/27/2024 Page 78 / 78

Program version Data version User group(s)


72.0 - 2/20/2024 (Build 175) 1/30/2024 2:24 PM Xylem: China - INT, Malaysia - INT

You might also like