Professional Documents
Culture Documents
Technical specifica on
Curves according to: Water Water [100%],4 °C,0.99994 kg/dm³,1.569 mm²/s
[m]
Head
52
50
48
46
44
42
40
38
36
34
32
30
28 86.1%
26
24
22
20
18
16
14
840 620mm
12
10
8
6
4
2
0
0 1000 2000 3000 4000 5000 [m³/h]
Curve: ISO 9906
Nominal (mean) data shown. Under- and over-performance from this data should
be expected due to standard manufacturing tolerances.
Configuration Please consult your local Flygt representative for performance guarantees.
Discharge diameter
500 mm
Inlet diameter
600 mm
Number of blades
3
Throughlet diameter
105 mm
Motor - Technical
Power factor - 1/1 Load Motor efficiency - 1/1 Load Total moment of inertia Starts per hour max.
0.85 95.4 % 31.3 kg m² 10
Power factor - 3/4 Load Motor efficiency - 3/4 Load Starting current, direct starting
0.83 95.8 % 3140 A
Power factor - 1/2 Load Motor efficiency - 1/2 Load Starting current, star-delta
0.78 95.6 % 1050 A
6
3577.1 m³/h
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 4800 5200 5600 [m³/h]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees. Curve: ISO 9906
200MLD Putatan WTP_R1 Chen, Oichin
0 Created on 2/16/2024 Last update 2/27/2024
1230
DN 500
L
min 535
105
840
665
65
1170
Z Z
15°
50
2700
Ref. line 1930
30
570
750
VIEW 670
350
Z-Z 510
Weight (kg)
Drive unit Motor L
Pump Discharge
700
66-46-XX 4850
905/915 2705
66-56-XX 5050
Outlet center line
520
800 Ø24 (4X) 66-46-XX 5050
906/916 2725
66-56-XX 5250
Discharge Scale Date
outlet DN 500
CP 3531 Pump outlet
DN 500 1:40 200622
Pump inlet Drawing number Revision