ROLL NO. : 47 SESSION : 2021-24 MOBILE NO.:6200142455 SUBJECT : INDUCTION ,SYNCHRONOUS AND SPECIAL ELECTRICAL MACHINES TOPIC NAME : CAPACITOR START INDUCTION RUN MOTOR
OBJECTIVE QUESTIONS AND ANSWERS
1.In a capacitor start induction run motor, the capacitor is connected in______ with ______ winding a) Series, main b) Parallel, starting c) Parallel, main d) Series, starting Ans. d)Series, starting 2.The capacitor start induction run motor is not suitable for a) Pumps b) Conveyers c) Compressors d) Hair driers Ans. d)Hair driers 3.Which of the following single phase induction motor is used for hard to start load such as compressors, conveyers and escalators? a) Capacitor start single phase IM b) Split phase single phase IM c) Shaded pole IM d) None of these Ans. a)Capacitor start single phase IM 4.The current in a starting winding of a capacitor start IM a) Lags the main winding current b) Is in phase with the V of the main winding c) In phase with the supply V d) Leads with respect to main winding Ans. d)Leads with respect to main winding 5.In a capacitor start motor, the phase difference between starting and main winding current can be nearly a) 10° b) 30° c) 90° d) 20° Ans. C)90 degree 6.In a capacitor start single phase motors a) Current in main winding lags the voltage b) Current in starting lags the voltage c) Current in starting voltage in phase with V d) None of the above Ans. a)Current in main winding lags the voltage 7.In a capacitor start single phase motor, when capacitor is replaced by a resistance a) Torque will increase b) The motor will consume less power c) Motor will run in reverse direction d) Motor will continue to run in same direction Ans. d)Motor will continue run in same direction 8.A single phase capacitor start motor will take starting current nearly a) 4 to 6 times to full load current b) 3 times the full load current c) Twice the full load current d) Same as full load current Ans. b)3 times the full load current 9.capacitor start induction run motor is used as a) Driers b) Washing machine c) Conveyers d) Fans Ans. c)Conveyers 10.Which of the following are the components of capacitor start induction motor a) Cage rotor b) Stator c) Windings d) All of the above Ans. d)All of the above 11.At what angle does the windings in capacitor start induction run motor are placed? a) 0° b) 90° c) 120° d) 180° Ans. b)90 degree 12.The main and auxiliary winding impedance of 50Hz capacitor start single phase IM is Zm=(3+j3)Ω and Za=(7+j3). Determine the value of the capacitor to be connected in series with the AW achieve phase difference of 90° between currents of two windings at the start a) 225µF b) 22.5µF c) 318µF d) 31.8µF Ans. c)318 micro Farad 13.Which of the following are the properties of short run capacitor ? a) Oil -filled paper b) Long period rated c) Electrolyte d) Water- filled paper Ans. c)Electrolyte 14.A capacitor start induction run type motor uses____phases. a) Single b) Two c) Three d) both a) and b) Ans.b)Two 15.The starting winding resistance of capacitor start induction run motor must be a) high b) low c) moderate d) none of the above Ans.a)High 16.At what percent of synchronous speed, the auxiliary winding is disconnected ? a) 40- 45% b) 50 55% c) 60-65% d) 70-80% Ans.d)70-80% 17.In this motor, capacitor is used for a) Long time b) Short time c) Both a) and b) d) None of the above Ans.b)Short time 18.The resistance and reactance of main winding of a 50Hz capacitor start single phase IM are √3Ω and j1Ω respectively. The power factor angle of auxiliary winding to achieve the maximum starting torque is a) 60° b) 15° c) 45° d) 30° Ans.d) 30 degree 19.The resultant of both currents Im and Ia is a) In phase with V b) Out of phase with V c) Almost in phase with V d) None of the above Ans.c)Almost in phase with V 20.A capacitor start induction run motor is also called a) Two value capacitor motor b) Three value capacitor motor c) Single value capacitor motor d) None of the above Ans.c) Single value capacitor motor