Calculation For Air Blower:

BOD : 800 mg/lit


BOD Loading : 30 X 800
: 24 Kg
To neutralize 1 Kg of BOD requires 2.0 Kgs of O2
For 18 Kg of BOD : 24 X 2.0
: 48 Kg of Oxygen
Airflow Required per hr : 48/(24 x 1.203 x 0.232 x 0.5 x 0.21)
: 68.25 m3/hr
Volume of Collection Sump : 18m3
Mixing Factor : 18 x 50%
: 9 m3
Hence the total Air requirement : 68.25 + 9
: 77.25
Safety factor (10%) : 77.25 X 10%
Total Air Flow Required : 78.15 m3/hr

8
Design Report for STP