Frequency: 50
Fuel Type: Diesel
Standby Prime
Fuel consumption kVA (kW) kVA (kW)
Ratings 175 (140) 160 (128)
Load 1/4 1/2 3/4 Full 1/4 1/2 3/4 Full
gph 3.0 5.4 7.3 9.1 2.7 5.0 6.8 8.4
L/hr 13.62 24.50 33.26 41.25 12.25 22.72 31.06 38.38
Fuel flow
Maximum fuel flow, L/hr 106
Maximum fuel inlet restriction, mm Hg 127-254
Maximum fuel inlet temperature (°C) 71
Air
Combustion air, m3/min 12.72 12.30
Maximum air cleaner restriction, kPa 3.7-6.2
©2009 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and
Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power
Generation. Other company, product, or service names may be trademarks or service marks of others.
Exhaust Standby rating Prime rating
Exhaust gas flow at set rated load, m3/min 35.82 34.14
Exhaust gas temperature, °C 561 544
Maximum exhaust back pressure, kPa 10.2
Genset outline
Open set
Enclosed set
Outlines are for illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.
©2009 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and
Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power
Generation. Other company, product, or service names may be trademarks or service marks of others.
Alternator data
Feature code Connection1 Temp rise degrees C Duty2 Alternator Voltage
B681-2 Wye, 3 Phase 163/125 S/P UCI274F 380-415V
B726-2 Wye, 3 Phase 125/105 S/P UCI274G 380-440V
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
Ratings definitions
Emergency Standby Limited-Time running Prime Power (PRP) Base Load (Continuous)
Power (ESP) Power (LTP): Power (COP)
Applicable for supplying power to Applicable for supplying power to a Applicable for supplying power to Applicable for supplying power
varying electrical load for the constant electrical load for limited varying electrical load for continuously to a constant electrical
duration of power interruption of a hours. Limited Time Running unlimited hours. Prime Power load for unlimited hours.
reliable utility source. Emergency Power (LTP) is in accordance with (PRP) is in accordance with ISO Continuous Power (COP) in
Standby Power (ESP) is in ISO 8528. 8528. Ten percent overload accordance with ISO 8528, ISO
accordance with ISO 8528. Fuel capability is available in 3046, AS 2789, DIN 6271 and BS
Stop power in accordance with ISO accordance with ISO 3046, AS 5514.
3046, AS 2789, DIN 6271 and BS 2789, DIN 6271 and BS 5514.
5514.