Professional Documents
Culture Documents
Fireguard® Tanks 4
Dike Tanks 6
Horizontal Tanks 8
Vertical Tanks 11
Hopper Series 12
Fire Hopper 13
Accessories 14
Highland also offers the security of a With Highland Tank, you get historically
diversified product line and extensive fabrication proven steel design and construction that provide
capabilities. The primary aspect of The Highland secure, responsible storage for the rigors of the
Advantage is our reputation for timely delivery of aboveground environment. In addition, you have
high-quality tank products by our professional the flexibility of customizing the tanks to suit your
drivers experienced with tank handling. individual needs.
Each tank is constructed, tested, and Our tanks are competitively priced and readily
labeled in accordance with Underwriters available from our strategically located regional
Laboratories Standard for Safety for the distributors and manufacturing facilities. Highland
Aboveground Storage of Flammable and can effectively provide you with environmentally
Combustible Liquids. The UL Tank Construction safe, structurally sound, aboveground storage tank
Codes provide a long history of structural solutions well into the 21st century and beyond.
1
C O N S T R
Double-wall UL-2085
Fireguard® fire-rated tanks are thermally
insulated, secondarily-contained, double wall
tanks. The notable difference is the interstice.
Fireguard® tanks are constructed with a
minimum 3" interstice around the inner tank. This
interstice is completely filled with a lightweight,
monolithic material which provides thermal Single-wall Double-wall
UL-142 Tanks UL-142 Tanks
insulating properties as well as interstitial
monitoring capabilities. Both the inner and outer
tanks are provided with emergency vent fittings.
Highland is licensed to use this technology by the
Steel Tank Institute (STI). Highland’s quality
control team and random inspections by STI
ensure continuous quality control.
All UL-142 or UL-2085 tanks are intended to be installed in
accordance with NFPA 30, 30A, 31 & 37.
Fireguard Double-wall UL-2085 Fireguard Double-wall UL-2085
Insulated Cylindrical Tanks Insulated Rectangular Tanks
3
D E S
4
I G N
Nominal
Capacity Inner Tank Outer Tank Thickness Weight
(Gallons) Dia. L Dia. AOH* L (lbs.)
300 3'2" 5'0" 4'2" 5'0" 6'0" 10 ga. 1,874
500 4'0" 5'5" 4'6" 5'4" 6'0" 10 ga. 2,824
1,000 4'0" 10'9" 4'6" 5'4" 11'4" 10 ga. 4,580
1,000 5'4" 6'0" 5'10" 6'8" 6'7" 7 ga. 4,753
Cylindrical Design 2,000 5'4" 12'0" 5'10" 6'8" 12'7" 7 ga. 7,917
3,000 5'4" 18'0" 5'10" 6'8" 18'7" 7 ga. 11,079
4,000 5'4" 24'0" 5'10" 6'8" 24'7" 7 ga. 14,242
4,000 8'0" 10'8" 8'6" 9'4" 11'3" 1/4" 14,327
5,000 8'0" 13'4" 8'6" 9'4" 13'11" 1/4" 16,734
6,000 8'0" 16'0" 8'6" 9'4" 16'7" 1/4" 19,058
8,000 8'0" 21'4" 8'6" 9'4" 21'11" 1/4" 24,577
10,000 8'0" 26'8" 8'6" 9'4" 27'3" 1/4" 29,272
12,000 8'0" 32'0" 8'6" 9'4" 32'7" 1/4" 34,071
15,000 10'0" 25'6" 10'6" 11'4" 27'1" 1/4" 35,079
20,000 10'0" 34'0" 10'6" 11'4" 34'7" 1/4" 45,788
25,000 10'0" 42'7" 10'6" 11'4" 43'2" 1/4" 51,793
30,000 10'0" 51'2" 10'6" 11'4" 51'9" 1/4" 60,517
*AOH - Approximate Overall Height
Additional capacities and dimensional sizes available upon request.
5
D E S
TANK
Highland’s Dike Tank is one of the most versatile TANK DIKE
DIAMETER
solutions for your aboveground containment
needs! Highland’s innovative thinking made the first DIKE
HEIGHT
dike tank available in 1984. That same forward
DIKE DIKE DIKE
thinking continues today! Available in single or SUPPORTS WIDTH LENGTH
Nominal Tank Tank Nominal Dike Dike Approximate Wt. Approximate Wt. Approximate Wt.
Capacity Dimensions Capacity Dimensions Dike Only Tank & Dike Shelter Tank
(Gallons) Diameter Length (Gallons) LxWxH (lbs.) (lbs.) (lbs.)
240 3'2" 4'0" 264 4'0" x 5'9" x 1'8" 435 740 1,418
300 3'2" 5'0" 330 7'0" x 4'0" x 1'8" 619 944 1,395
500 4'0" 5'5" 550 7'5" x 6'0" x 1'8" 964 1,746 2,311
1,000 4'0" 10'9" 1,100 12'9" x 6'0" x 2'0" 1,826 3,227 4,269
1,000 5'4" 6'0" 1,100 9'2" x 8'0" x 2'0" 1,541 2,782 4,026
1,500 5'4" 9'0" 1,650 13'10" x 8'0" x 2'0" 2,278 4,047 5,615
2,000 5'4" 12'0" 2,200 16'0" x 8'0" x 2'4" 3,409 5,718 6,921
2,500 5'4" 15'0" 2,750 17'6" x 8'0" x 2'10" 3,600 6,384 7,942
3,000 5'4" 18'0" 3,300 22'0" x 8'0" x 2'8" 3,900 7,050 9,500
4,000 5'4" 24'0" 4,400 28'0" x 8'0" x 2'8" 4,815 8,725 12,543
5,000 8'0" 13'4" 5,500 17'0" x 10'10" x 4'0" 5,325 10,817 12,927
6,000 8'0" 16'0" 6,600 20'6" x 10'10" x 4'0" 6,314 12,552 14,993
8,000 8'0" 21'4" 8,800 27'6" x 10'10" x 4'0" 8,695 16,476 19,879
10,000 8'0" 26'8" 11,000 35'0" x 10'10" x 4'0" 10,869 20,044 24,351
12,000 8'0" 32'0" 13,200 36'8" x 12'0" x 4'0" 11,301 22,272 26,310
15,000 10'0" 25'6" 16,500 31'0" x 12'0" x 6'0" 11,813 24,671 27,261
20,000 10'0" 34'0" 22,000 41'0" x 12'0" x 6'0" 13,559 27,533 35,042
25,000 10'0" 42'6" 27,500 51'0" x 12'0" x 6'0" 18,088 32,385 43,475
30,000 10'6" 46'6" 33,000 61'4" x 12'0" x 6'0" 21,345 39,995 50,087
Note: Sizes and capacities are for 110% containment. 150% containment dikes are also available.
6
I G N
Highland
AREO-Style
Dike Tanks
Maintenance is minimized by the AREO-Style
Dike Tank's specially design rain and debris
diverting system. The system maintains
excellent ventilation while preventing rain
water and other debris from accumulating
and may need to be handled as contaminated
substances. Any unexpected overfill from the
emergency vent is safely contained as part of
the patented design.
can be relocated, if necessary. The entire tank 300 330 7'0" x 4'0" x 1'8" 1,600
500 550 7'5" x 6'0" x 1'8" 2,100
system possesses the strength and 1,000 1,100 12'9" x 6'0" x 2'0" 3,900
1,500 1,650 13'10" x 8'0" x 2'0" 4,950
impermeability of steel. The AREO-Style Dike 2,000 2,200 16'0" x 8'0" x 2'4" 6,000
3,000 3,300 22'0" x 8'0" x 2'4" 7,500
Tank carries an Underwriters Laboratories 4,000 4,400 27'0" x 8'0" x 2'9" 9,000
4,000 4,400 12'5" x 10'10" x 5'0" 9,500
5,000 5,500 17'0" x 10'10" x 4'0" 11,500
6,000 6,600 20'6" x 10'10" x 4'0" 13,000
8,000 8,800 27'6" x 10'10" x 4'0" 17,000
10,000 11,000 35'0" x 10'10" x 4'0" 21,000
12,000 13,200 36'9" x 4'0" x 4'0" 23,000
15,000 16,500 31'0" x 12'0" x 6'0" 30,000
20,000 22,000 41'0" x 12'0" x 6'0" 34,000
30,000 33,000 62'2" x 12'0" x 6'0" 41,000
7
D E S
Horizontal Tanks
Highland’s aboveground horizontal tanks are Stainless steel is available as an option for
designed and engineered to meet the storing chemicals and liquids not compatible
demanding needs of industry. All aboveground with carbon steel. Interior coatings for storing
horizontal tanks are manufactured in strict aviation fuel, potable water and for other
accordance with Underwriters Laboratories special service can be applied. The standard
142 specifications. exterior coating on all aboveground tanks is
Single-wall or double-wall configurations red primer. Other VOC compliant coating
can be manufactured with numerous options range from a commercial blast with
accessories available. Standard tanks are epoxy primer to complete epoxy/urethane
constructed of mild carbon steel. multi-coat systems.
General Tank Information Tank Weight Information Support Systems Weight Information
Capacity Dimensions Thickness Single-wall Thickness Double-wall Saddles BDH Supports Skids Stabilizers
(Gallons) Diameter Length Primary Tank (lbs.) Outer Tank (lbs.) Each (lbs.) Total (lbs.) Total (lbs.) Total (lbs.)
8
I G N
General Arrangement
DIAMETER
Each standard tank is fabricated with threaded
fittings to match the diagram at right with
customized fitting arrangements available on
request. All aboveground horizontal tanks may
be fitted with various types of UL-listed LENGTH
2" 2" 4" 4" 4" 4" 4" - Typical 6 Places (13" Spacing on 4,000 - 8'0")
24" CL 24"
6", 8" or 10" Fitting for
500-4'0" thru 1,000-5'4" Diameter 4,000 - 6'0" thru 50,000 - 12'0" Diameter Emergency Vent (outer tank)
X - Fitting for primary tank emergency vent use; X - Fitting through outer shell only - interstitial emergency vent fitting
Horizontal UL-Listed
Tank Support Systems
Tank supports are available for capacities up Small tank saddle style for 38"– 72" diameter, Large tank saddle style for 84"–144" diameter,
to 4,000 gallons. 300–6,000 gallon tanks. 7,000–50,000 gallon tanks.
Small Tank Skids for 38"– 64" diameter, Large Tank Skids for 64"–96" diameter, Stabilizers are available on tanks from 38" to
300 –1,500 gallon capacity tanks. 2,000 –12,000 gallon capacity tanks. 64" diameter.
9
C O N S T R U C T I O N
10
D E S I G N
Vertical
Tank
Design
Highland Vertical Storage tanks provide
safe storage using the least property
square footage. Available in both carbon
and stainless steel, Highland Vertical
Tanks for the storage of flammable and
combustible liquids bear the Underwriters
Laboratories UL 142 Label. Highland
Vertical UL 142 tanks can be specified
with a flat, coned, or dished top and can
be manufactured to a maximum vertical
shell height of 35'0".
Because piping installations vary are required and provided on all Underwriters
Nominal Approximate
with each tank, size and location of Laboratories UL 142 tanks. Construction Capacity Tank Dimensions Weight
(Gallons) Diameter Height (lbs.)
fittings are specified by the customer. options similar to those for horizontal tanks are
185 3'2" 3'4" 155
Threaded fittings are included with each also available on vertical tanks. Other options 240 3'2" 4'0" 238
300 3'2" 5'0" 272
tank. Normal and emergency vent fittings include support legs and skirts with coned or 500 4'0" 5'5" 415
1,000 4'0" 10'9" 958
1,000 5'4" 6'0" 1,128
dished bottoms. 1,500 5'4" 9'0" 1,608
2,000 5'4" 12'0" 1,988
The standard exterior coating is primer. 3,000 8'0" 8'0" 4,076
4,000 8'0" 10'6" 4,500
To protect your investment further, specialized 5,000 8'0" 13'4" 5,195
6,000 8'0" 16'0" 5,850
finish coatings are available. Special linings are 8,000 10'0" 14'0" 6,415
10,000 10'0" 17'0" 7,532
available for fertilizers, potable water, 12,000 10'0" 20'6" 8,649
15,000 10'0" 25'6" 10,213
chemicals, or other products with special 20,000 10'0" 34'0" 12,750
25,000 12'0" 29'8" 16,450
considerations. 29,600 12'0" 35'0" 19,100
11
D E S
Hopper Series
Tanks
Innovative Aboveground Storage
Highland Hoppers are state-of-the-art
technology for low profile, secondarily
contained aboveground storage. Suitable
for the containment of all types of liquid
fuels, new and used oils, waste solvents
and antifreeze, they are available in nine
convenient capacities to meet every Our unique, extended-dome top design emergency venting of the containment hopper.
need. Highland Hoppers are designed prevents rain, snow and debris from collecting Elevation supports and a top-view interstitial
and built to UL-142 specifications. Each in the secondary containment and provides monitoring tube are included on all models.
Hopper consists of an inner tank, placed
in the second tub-like steel container, Nominal Capacity Tank Overall Thickness Approximate Wt.
(Gallons) Diameter Depth Diameter Height (lbs.)
providing a minimum of 110% secondary
120 30" 40" 36" 46" 12 ga. 411
containment. 185 38" 40" 44" 47" 12 ga. 516
285 46" 40" 52" 51" 12 ga. 671
500 62" 40" 68" 53" 12 ga. 970
1,000 84" 42" 92" 54" 7 ga. 1,693
1,500 96" 48" 108" 60" 7 ga. 3,643
2,000 108" 51" 120" 63" 7 ga. 3,888
2,500 108" 62" 120" 75" 7 ga. 4,635
3,000 108" 76" 120" 91" 7 ga. 5,143
12
I G N
Fire-HopperTM
TM
Highland Fire-Hoppers are state-of-the-
art technology for low profile, secondarily
contained, fire-protected aboveground fuel
TM
storage. The UL-2085 listed Fire-Hopper
is a double-wall steel tank with light-
weight porous insulating material between
the two walls, providing thermal protec-
tion to the primary tank.
Optional Custom
TM Pump Mount**
They are used where a fire-protected tank The Fire-Hopper's unique domed top Optional step
with 1" thick
fiberglass grating
is needed because of setback limitations design prevents rain, snow, and other
and/or regulatory insistance. Fire- debris from accumulating on top of the
TM
Hoppers are suitable for the storage of tank. With the tank's small footprint and
flammable and combustible liquids. optional pump and equipment packages,
Interstice filled with
lightweight insulating
Highland Fire-HoppersTM cost less to Overfill Chamber material
with hinged,
lockable Emergency Vent
install. aluminum lid Secondary Tank
Monitoring
Tank Supports
13
A C C E S S O R I E S
Stairs, Platforms and Walkways Heaters and Insulation High Level Alarms and Pump Switches
14
S P E C I F Y I N G
To receive a quotation, or to order a tank, please For Vertical Tanks ❑ Straight Ladder (90º)
complete the following: ❑ Safety Cage for Ladder (vertical tanks)
Is secondary containment required? Yes • No ❑ Step-off Platform (vertical tanks)
Identify the product to be stored:__________ at (Consider: Hoppers®, and Dike Tanks)
what temperature: ________˚F or Ambient. Do you want a Catwalk with handrail?
Specify diameter: _________ and Yes • No
Select capacity based on delivery volume and rate of height: __________ (see chart of standard sizes). Specify length: ____________
use: __________ gallons.
Specify Tank Model (check all that apply) Do you want a handrail around the tank top? (vertical
Select Horizontal or Vertical tank style. Continue tanks) Yes • No
here for Horizontal tanks or skip to Vertical tanks. ❑ Single-wall ❑ Petro-Hopper
❑ Double-bottom ❑ Haz-Hopper Do you want an internal ladder? Yes • No
❑ Double-wall ❑ Fuel-Hopper
For Horizontal Tanks Do you need a steam/hot water pre-heater?
Specify Construction (check all that apply) Yes • No
Is secondary containment required? Yes • No
(Consider: Fireguard®, Shelter or Dike Tanks) ❑ Cone Top ❑ Cone Bottom Determine size and number of threaded connections;
❑ Dished Top ❑ Dished Bottom __2” __4” __6” __8” __10”
Specify Tank Model (check all that apply) ❑ Flat Top ❑ Flat Bottom
❑ Lap Weld ❑ Butt weld Determine size and number of bolted flanges: __2”
❑ Double-wall Fire Protected ❑ UL-142 ❑ API 650 __4” __6” __8” __10”
❑ Double-wall Steel with Stand Offs ❑ Support Legs ❑ Support Beam
❑ Double-wall Steel ❑ Support Skirt Clearance: __________ Do you want level sensing equipment?
❑ Single-wall Yes • No
❑ Shelter Tank If YES, specify levels of notification: 5% • 10% •
❑ OPTM Tank Coatings, Linings and Accessories: 25% • 50% • 75% • 90% • 95% • 98%
❑ Dike Tank
with ❑ Rain Shields or ❑ Pitched Top ❑ Red Primer (no blast) Do you want double-wall interstitial or dike
❑ SP6 Blast with Epoxy Primer containment monitoring equipment? Yes • No
Specify diameter: _________ and Thermal Insulation
length: __________ (see chart of standard sizes). ❑ External Batt & Skin System Do you want a remote alarm? Yes • No
❑ External Spray-on Foam System If YES, specify for which of the
Will tank be in a flood plain? Yes • No ❑ Injected Foam System above:____________________________
If YES, do you want standard hold down straps? Yes ❑ Other _____________________________
• No Do you want electronic tank gauging equipment?Yes
Do you want/need an internal lining: Yes • No • No
Specify Supports for Horizontal Tank models Please specify: _____________________________
❑ UL Style Sadles (2 per tank) (An internal lining requires at least one manway in the tank - Do you want a pump platform? Yes • No
❑ Skids (up to 12,000 gallons) Minimum 500 gallon) If YES, specify location, height from grade, and
❑ Supports (up to 4,000 gallon) dimensions:
❑ Stabilizers (up to 4,000 gallons) Do you want/need manways? Yes • No ❑ Side of tank
If YES, specify number and size: ❑ End of tank
Do you want a compartmented tank? Yes • No ___ 24” ___ 30” ___ 36” ❑ Side of dike
If YES, specify compartment number and size; use a If YES, do you want (1) manway to be a loose-bolt (emergency ❑ End of dike
“/” for single bulkhead and “//” for a vent) lid? Yes • No Height from grade: __________
double:____________________________ ❑ 12” x 24”
Do you want access to or near tank top for filling etc.? ❑ 24” x 24”
Continue at Coatings, Linings and Accessories Yes • No ❑ 24” x 36”
If YES, specify the type of access desired:
❑ Free-standing Standard Stairs (45º) Refer to accessories section of this brochure for
❑ Bolted Standard Stairs (45º) other options and list here:
❑ Free-standing Ships Ladder (60º) ___________________________________
❑ Bolted Ships Ladder (60º)
___________________________________
___________________________________
15
Selecting
Horizontal Tanks
To select or specify a Highland horizontal tank Horizontal Tanks
copy, complete and fax page 15: A. Tank Diameter – Ranging from 38" to 12' M. Leak Detection System – Specify compo
nent pieces
■ Select desired tank capacity B. Tank Length – Ranging from 4' to 59’6"
N. Pump Platform – (Inside or outside dike,
■ Single or double wall construction C. Compartment Bulkheads – Single or double or on skids)
■ Secondary containment D. Interior Surface Preparation – Specify O. Exterior Ladder – (Outside of dike and/or
interior coating and sandblast if required tank with or without a platform)
■ Select internal and external coatings
E. Manway – Diameters from 24" to 36" P. Stairs (45º) / Ships Ladder (60º)
■ Determine size, location and number of
fittings F. Interior Ladder – 2" x 1/4" sides – 3/4" Q. Platform/Walkway
rungs on 12" centers
■ Determine accessories and options R. Exterior Coating
G. Standard Threaded Fittings – Specify size,
number, location S. UL Style Saddle (2 per tank)
A simple sketch, showing size, location of fittings H. Flanged Fittings – 150 # A.S.A. Specify T. Supports (up to 4,000 gal.)
size, number, location
and accessories required, is helpful when U. Skids (up to 12,000 gal.)
I. Steam/Hot Water Preheater for fuel oil
ordering. For quick and easy reference when V. Stabilizers (up to 4,000 gal.)
J. 110% Containment Dike – (150% capacity
specifying and ordering, please refer to the also available) W. Hold-down Straps (for flood plains)
adjacent diagrams of standard features and some K. Rainshields X. Thermal Insulation System
of the accessories available. L. Pitched Top Canopy
TANK
P
Q
K
N
J O DIKE
Q
Double-wall
Interstitial H
Monitoring Pipe M G E
Double-wall, N
Steel Outer Tank
Fireguard Double-wall C
Steel UL 2085 Steel Outer Tank R I F
Inner or Aluminum Batt & Skin
Tank External Insulation System
W S
A
Fireguard UL 2085
Thermal Insulation D
or Other External
Insulation System (X) U
T
V
16
Selecting
Vertical Tanks
To select or specify a Highland vertical tank, Vertical Tanks
copy, complete and fax page 15: A. Tank Diameter – Ranging from 38" to 12' L. Cone Bottom
■ Select desired tank capacity B. Tank Height – Ranging from 4' to 29’6" M. Dished Bottom
■ Single or double wall construction
C. Manway – Diameters from 24" to 36" N. Double Bottom
■ Secondary containment
D. Interior Surface Preparation – Specify interior O. Double Wall
■ Select internal and external coatings coating and sandblast if required
P. Exterior Ladder
■ Determine size, location and number of E. Interior Ladder – 2" x 1/4" sides – 3/4" rungs
fittings on 12" centers Q. Ladder & Cage
■ Determine accessories and options
F. Standard Threaded Fittings – Specify size, R. Railing
number, location
S. Exterior Coating
A simple sketch, showing size, location of G. Flanged Fittings – 150 # A.S.A. Specify size,
number, location
fittings and accessories required, is helpful
when ordering. For quick and easy reference H. Fuel Oil Preheater F
when specifying and ordering, please refer to I. Leak Detection System – Specify component C
pieces G
the adjacent diagrams of standard features and
F
some of the accessories available. J. Support Legs
F
K. Support Skirt
N G
C
F
Q
F
I
K
R
D
S
K L J
A Tank Diameter
17
Highland
Manufacturing
Locations
Lowe Engineering
1510 Stoystown Road
Friedens, PA 15541
(814) 443-6800
FAX 444-8662