You are on page 1of 1

4.

12 Change of Power Input Type

4.12 Change of Power Input Type


The power specifications are:
RPU-013: 100 VAC, 220 VAC, 24 VDC
MU-201CR and MU-231CR: 100 VAC to 220 VAC, 24 VDC

F1
- 100 VAC: 10 A (125 V)
PWR board
- 220 VAC: 5 A (250 V)
- 24 VDC: 20 A (125 V)
FIL board

Fig. 4.12.1 Power Label of RPU-013

4.12.1 Changing AC Power Input


1. Jumper setting and adjustment
When changing the AC main type for the AC PWR board (03P9339A) and B (100 VAC),
and then C and D (220 VAC), it is required to make the setting of jumpers and make
adjustments of input overvoltage of this board.
R21: Adjustment of overvoltage VR

J108
220 VAC: Open
100 VAC: Jumper between 1-2, 4-7, 5-8

CR23:INPUT ERROR

Fig. 4.12.2 AC PWR Board

Table 4.12.1 Adjstment of over voltage protection circuit

4-64