You are on page 1of 2

IDENTControl Compact IC-KP2-1HB6-V15B

Dimensions

42
33
136.6

CH2
61.4

36
CH1
15

Model Number 107

IC-KP2-1HB6-V15B
Control interface unit
IDENTControl Compact
with PROFIBUS DP interface
Electrical connection
Features
socket at housing read/write head
• LED status indicator of bus communi- 4 1 +
cation and read/write head 2 A
3 -
3 1
Function
4 B
5 5
2
2 1 = NC
The RFID identification system IDENTControl RS 232 2 = RxD
1 3
Compact from Pepperl+Fuchs offers a vast 3 = GND
4 = TxD
number of benefits compared to other sys- 4
5
5= NC
tems, thanks to its innovative design. The 2 1 = + 24 V
control interfaces IDENTControl and IDENT- voltage 2 = NC
Control Compact make up the core of the sys- supply 3 1 3 = GND
tem. 4 = NC
BUS Diag

With its integrated interfaces to all commer-


PWR/ERR

4
2
cially available fieldbus systems such as
PROFIBUS 1 = VP
CH1

PROFIBUS, PROFINET, Ethernet, EtherCAT, 2 = RxD/TxD-N


1 3 3 = DGND
CC-Link, serial connections (RS 232 or 4 = RxD/TxD-P
5
RS 485) and numerous connection options 4 5= NC
for read/write heads available for frequency
ranges LF, HF and UHF, the IDENTControl
Compact control interface can be easily and
Indicating / Operating means
flexibly adapted to your requirements.
Release date: 2019-07-26 10:14 Date of issue: 2019-07-26 200874_eng.xml

LEDs on the front of the housing indicate bus


communication, connected read/write heads
and active read/write commands. Reliability
1
of the application is further increased by
using trigger sensors. B CD E
The system is equally suited for use in control
7 89 A

BUS Address
F 01 2

cabinets and field use in IP67. The interface CH1 3 45 6 (High Nibble)
to the higher-level fieldbus is integrated in the
housing, and all connections are designed
such that they are pluggable. This enables B CD E
7 89 A

BUS Address
F 01 2

simple installation and quick, problem-free (Low Nibble)


replacement in case of device failure. The
3 45 6

consistent EMC design, with metal housing, PWR/ERR


grounding and shielded wires, offers a high
degree of reliability.
BUS Diag

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.


Pepperl+Fuchs Group
www.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Germany: +49 621 776 4411
fa-info@de.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
1
IDENTControl Compact IC-KP2-1HB6-V15B

Technical data Accessories


General specifications V1-G-5M-PUR-ABG-V1-W
Number of read/write heads max. 1 Connecting cable, M12 to M12, PUR ca-
UL File Number E87056
ble 4-pin, shielded
Functional safety related parameters
MTTFd 140 a V1-G-10M-PUR-ABG-V1-W
Mission Time (TM) 10 a Connecting cable, M12 to M12, PUR ca-
Diagnostic Coverage (DC) 0% ble 4-pin, shielded
Indicators/operating means
LED BUS green: Slave is at state "Data Exchange" ICZ-3T-0,2M-PUR ABG-V15B-G
red: Bus error Y connection cable for PROFIBUS
LED Diag No function
LED 1 Status indicator for read/write head ICZ-2T/TR-0,2M-PUR ABG-V15B-G
green: command at read/write head active Terminal cable for PROFIBUS with termi-
yellow: approx. 1 second long, if command was successfully
executed
nal resistor
LED CH1 green: read head detected V15B-G-5M-PUR-ABG-V15B-G
red: Configuration error
LED PWR/ERR green: power on
Bus cable PROFIBUS, M12 to M12, PUR
red: Hardware fault cable
Rotary switch Address setting 00 ... 7E, FF (hexadecimal)
BUS Address (high nibble): 0 ... 7, F V15B-G-10M-PUR-ABG-V15B-G
BUS Address (low nibble): 0 ... F Bus cable PROFIBUS, M12 to M12, PUR
Electrical specifications cable
Rated operating voltage Ue 20 ... 30 V DC , PELV
Ripple ≤ 10 % at 30 V DC V15B-G
Current consumption ≤ 4 A incl. read/write heads Cable socket, M12, for PROFIBUS, ad-
Power consumption P0 2 W Without read/write head justable
Galvanic isolation basic insulation acc. to DIN EN 50178, rated insulation voltage of
50 Veff V15SB-G
Interface 1 Cable connector, M12, for PROFIBUS,
Interface type PROFIBUS adjustable
Physical RS-485
Protocol PROFIBUS DP acc. to EN 50170 ICZ-MH05-SACB-8
Transfer rate 9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s Mounting aid for DIN rail
3; 6; 12 Mbit/s self-synchronizing
Directive conformity
V1S-G-0,15M-PUR-ABG-SUBD
Electromagnetic compatibility Adapter M12 on Sub-D for PC connection
Directive 2014/30/EU EN 61000-6-2:2005, EN 61000-6-4:2007 with null modem cable
Standard conformity
V1S-G-5M-PUR-ABG-SUBD9
Degree of protection IEC 60529:2001
Adapter, M12 x 1, to sub-D, 9-pin
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Climatic conditions air humidity max. 96 %
Salt spray resistant to EN 60068-2-52
Shock and impact resistance Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6
Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-
27
Mechanical specifications
Degree of protection IP67
Connection read/write head: M12 plug connection, 4-pin, screened,
Power supply: M12 connector
Protective earth: M4 earthing screw
Diagnostic RS 232: M12 connector
PROFIBUS: M12 connector, B-coded
Material
Housing powder coated aluminum
200874_eng.xml

Installation screw fixing


Mass approx. 300 g
Date of issue: 2019-07-26
Release date: 2019-07-26 10:14

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.


2 Pepperl+Fuchs Group
www.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Germany: +49 621 776 4411
fa-info@de.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com