You are on page 1of 5

ITEM SHORT UOM

SR. NO. PLATFORM P&ID P&ID Rev LINE NUMBER INSULATION SPEC INSTALL SCOPE ITEM NAME SIZE 1 SIZE 2 QTY REMARKS
CODE (LM/EA)

1 BRRI-780-789 PA-900020-001 A 4"-P-1001-15NX0P-N N 15NX0P Onshore FLG Flange 6 1.00 EA


2 BRRI-780-789 PA-900020-001 A 4"-P-1001-15NX0P-N N 15NX0P Onshore FLAP3 FLANGE 3000 6 1.00 EA Offspec-90NX0T
3 BRRI-780-789 PA-900020-001 A 4"-P-1001-15NX0P-N N 15NX0P Onshore GASAP3 GASKET 3000 6 1.00 EA Offspec-90NX0T
4 BRRI-780-789 PA-900020-001 A 4"-P-1001-15NX0P-N N 15NX0P Onsite PIP Pipe 6 1.00 M
5 BRRI-780-789 PA-900020-001 A 4"-P-1001-15NX0P-N N 15NX0P Skid-1 E90 Elbow 90° 6 1.00 M
5 BRRI-780-789 PA-900020-001 A 4"-P-1001-15NX0P-N N 15NX0P offshore BRANCH #N/A 6 2 1.00 M
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

Insert above this line and copy é é é

Notes, Exclusion, Inclusions, Basis, Assumptions


1 MTO quantites are based the 3D Model avaialble as on xx-xx-xx
2 Stud bolts are not inlcuded in the MTO
3 vent lines are not modelled hence qunaties are based on assumptions
Short Code Item Remarks
Not Applicable
BLR Bleed Ring
BOSS Boss Welding
CAP Cap
CLP Clamp
CPJ Compound Joint
CNI Contoured Insert
CPL Coupling
CPH Coupling Half
CPR Coupling Reducer
E45 Elbow 45°
E90 Elbow 90°
B 90 90 DEG BEND
B 45 45 DEG BEND
FLG Flange
FLAP5 FLANGE 5000 offspec items
FLAP3 FLANGE 3000 offspec items
FL25 FLANGE 2500 offspec items
FL15 FLANGE 1500 offspec items
FL9 FLANGE 900 offspec items
FL6 FLANGE 600 offspec items
FL3 FLANGE 300 offspec items
FL1 FLANGE 150 offspec items
FBL Flange Blind
FBLP5 FLANGE BLIND 5000 offspec items
FBLP3 FLANGE BLIND 3000 offspec items
FBL25 FLANGE BLIND 2500 offspec items
FLB15 FLANGE BLIND 1500 offspec items
FBL9 FLANGE BLIND 900 offspec items
FBL6 FLANGE BLIND 600 offspec items
FBL3 FLANGE BLIND 300 offspec items
FBL1 FLANGE BLIND 150 offspec items
FBC Flange Blind Compact
FBJ Flange Blind W/JS
FLC Flange Compact
FLT Flange Composite
FLH Flange Hubless
FLR Flange Reducing
FLGJ Flanges W/JS
GSK Gasket
GASAP5 GASKET 5000 offspec items
GASAP3 GASKET 3000 offspec items
GAS25 GASKET 2500 offspec items
GAS15 GASKET 1500 offspec items
GAS9 GASKET 900 offspec items
GAS6 GASKET 600 offspec items
GAS3 GASKET 300 offspec items
GAS1 GASKET 150 offspec items
HUB Hub
HBL Hub Blind
INSGAS Insulating Gasket Kit
45TEE Lateral Tee Equal
45TRE Lateral Tee Reducing
NIPL Nipple
90EOT Olet - Elbolet
90FOT Olet - Flangeolet
45LOT Olet - Latrolet
90NOT Olet - Nipolet
90SOT Olet - Sockolet
90SWT Olet - Sweepolet
90TOT Olet - Threadolet
90WOT Olet - Weldolet
PIP Pipe
PLG Plug
REDC Reducer Concentric
REDE Reducer Eccentric
SER Seal Ring
SLW Sleeve Welding
SPC Spacer
SPCD Spacer & Spade
SPD Spade
F8 Spectacle Blind
BLT Stud Bolt
SWGC Swage Concentric
SWGE Swage Eccentric
90TEE Tee Equal
90TRE Tee Reducing
UN Union
Project/Bid No.: Input Project/Bid number
Project/Bid Description: Input Project/Bid Description
Revision: Input MTO Revision number
Completion Date: Input MTO issue date (did-mmm-yy)

Input Guidelines for new MTO


1 Platform Name, P&ID number with revision, Line Number columns shall be not be left blank any of the line items ü
2 Insulation type to be identified in the MTO with the designated code in the Line Number, If the insulation type is not available in the Line number then it has to discussed with the coordinator. ü
3 Offshore / Onshore installed items to be identified correctly under install scope column. ü
4 Item that are installed in the fabrication yard facility shall be identified as "onshore" where as items that are installed at onshore site (in the plant) shall be identified as "Onsite" under installation column. ü
5 Offshore / Onshore Modules to be identified as "Skid" under the install scope column, If there are more than one skid under same facility then all the skids to be identified separately (Skid-1, Skid-2... ) ü
6 Items short codes shall be as per the Tables and can be selected from the drop down list ü
7 Brach connections to be identified as per Piping material specification ü
Studs Bolts shall be identified in the MTO wher ever required. Size of bolt shall be as per gasket/flange size. Size and length of bolt will be changed/added during complilation stgae but extra length requirements shall be idenfied with
8
remark Eg: "spec blind" or "wafer check". ü
9 Spec break Flanges to be identified in the remarks with text "Off spec - 15NX0P". Item code shall be as per the short code, See the example item no 2 ( Face Cladding requirements can be identified from the mating Piping class) ü
10 Gaskets at spec breaks to be identified in the remarks with text "Off spec - 15NX0P". Item code shall be as per the short code, See the example item no 3 ü
11 Insulating gaskets to be identified in the MTO and it will later transferred to the SP item MTO ü
12 Bend Qty to be identified in the Bulks MTO and it will later transferred to the SP item MTO ü
13 For Well Head platform Flow line quantities shall be identified separately for each well in remarks with text "FL-1, FL-2…." ü
14 API flanges should have special attention and requirement of transition piece also to be checked with the coordinator ü
15 Flanges that needs Jack screw also need to be identified as per short code in the MTO ü
16 Requirement of Blind flanges and Gaskets at Tie in location, Future connection, demolitions, to be discussed and agreed with coordinator. ü
17 Notes that impact the MTO shall be identified in the Remarks ü
18 Scope of supply on Future items shall be discussed with coordinator and those items shall be identified in the install scope. (Future-Onshore, Future-Onshore) ü
19 Spectacle Blind, spade and spacers shall be part of Piping Bulks MTO ü
20 MTO basis to be include in the File at the Bottom ü
21 P&Id shall be highlighted on completion of each line and each p&Id shall be checked agaisnt index to ensure scope coverage ü
22 Highlighted P&Ids copies shall be handed over the coordinator on completion

Note Above guidelines are intended for New MTO and not for MTO revisions and doubts arising during MTO generation shall be discussed and agreed with co-ordinator
SR. NO. PLATFORM P&ID LINE NUMBER INSULATION SPEC INSTALL SCOPE ITEM SHORT CODE ITEM NAME SIZE 1 SIZE 2 QTY UOM (LM/EA) REMARKS

1 BRRI-780-789 PA-900020-001 4"-P-1001-15NX0P-N N 15NX0P Onshore FLG Flange 6 1.00 EA


2 BRRI-780-789 PA-900020-001 4"-P-1001-15NX0P-N N 15NX0P Onshore FLAP3 FLANGE 3000 6 1.00 EA Offspec-90NX0T
3 BRRI-780-789 PA-900020-001 4"-P-1001-15NX0P-N N 15NX0P Onshore GASAP3 GASKET 3000 6 1.00 EA Offspec-90NX0T
4 BRRI-780-789 PA-900020-001 4"-P-1001-15NX0P-N N 15NX0P Onsite PIP Pipe 6 1.00 M
5 BRRI-780-789 PA-900020-001 4"-P-1001-15NX0P-N N 15NX0P Skid-1 E90 Elbow 90° 6 1.00 M
5 BRRI-780-789 PA-900020-001 4"-P-1001-15NX0P-N N 15NX0P offshore BRANCH #N/A 6 2 1.00 M
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

Insert above this line é é é

Notes, Exclusion, Inclusions, Basis, Assumptions


1 MTO quantites are based the 3D Model avaialble as on xx-xx-xx
2 Stud bolts are not inlcuded in the MTO
3 vent lines are not modelled hence qunaties are based on assumptions

You might also like