You are on page 1of 2

Service Information

Document Title: Function Group: Information Type: Date:


Pressure check connections, 910 Service Information 27/03/2021
description
Profile:
A40G Volvo

Go back to Index Page

Pressure check connections, description


Showing Selected Profile

Valid for serial numbers


Model Production site Serial number start Serial number stop
A40G Volvo Braås 322001 329999
A40G Volvo Braås 332001 339999
A40G Volvo Braås 342001 349999
A40G Volvo Braås 352001 359999

Working hydraulics
For location of the pressure check connections, see Hydraulic system component location
For expected values when measuring at each pressure check connection, see Hydraulic pressure, specifications

Stand-by pressure
The pressure delivered by the pumps when the LS-line is disconnected.

LS-pressure
The current pressure in the LS-line.

Neutral position pressure


The pressure when the steering slide and dumping slide are in unaffected position and the LS-line is connected.

Max. pressure
The pressure at full load.

M1
Pressure for P3. In case the steering slide is unaffected, the pressure for P2 also goes in to the same pressure check
connection.
Max. pressure for P2 and P3 is measured when the hoist cylinders are run to top position.
Turn completely against the steering joint lock to remove P2 from the measurement.

M2
P2 and P3's common pressure.
Turn completely against the steering joint lock to show max. pressure for P2 and P3.
The max. pressure for P2 is measured by turning completely against the steering joint lock while lowering against end-
position. This lowers the pressure for P3 through CHV3 and then it's only possible to measure P2's max. pressure.
When dumping, P5 and P6 also affect the pressure via the Dump boost function

M3
Ground-dependent pump's pressure independent of the other pumps.

M4
Servo pressure for lowering load body.

M5
Servo pressure for dumping load body.

M6
Servo pressure from the pressure reducing valve R35 to PWM9501 and PWM9502 for the dumping function.

M7 (not provided with measuring nipple)


Steering pressure during right turn, pressure on the right steering cylinder's minus side, left steering cylinder's plus side.
During left turn, the refilling (anti-cavitation) pressure can be measured, which is equal to the pressure of MTRV1.

M8 (not provided with measuring nipple)


Steering pressure during left turn, pressure on the left steering cylinder's minus side, right steering cylinder's plus side. During
right turn, the refilling (anti-cavitation) pressure can be measured, which is equal to the pressure of MTRV1.

M9
Output pressure on pump 5 for intercooler's fan motor

M10
Pressure for radiator's fan motor
For max. pressure, see brake charging