You are on page 1of 1

HARDROCK 2 SD Flat roofs

Water absorption Características químicas


Rockwool consists of randomly The wool of rock is chemically inert and
orientated water-repellent fibres. Wetting it can not cause the apparition of
will therefore only occur in proximity to its corrosion of materials. It’s a material
surface. which does not lose their shape when
As Rockwool is diffusion open, boards the time goes by. Doesn’t cause the
that become wet during installation must bacterial development.
be allowed to dry out naturally, prior to
the application of the roof membrane. Dimensions (mm)

•It’s little sensitive to the variations of the


temperature and the hydrometry. Large: 1200 2400 Wide: 1000 1200 600
Medium inflated of the thickness 2% Thickness
(<5%) (test tube maintained 15 minutes (mm) 50 55 60 65 70 75
to 100ºC, 100%) (Relative humidity and Thickness
Product description later cooling to the environment (mm) 80 85 90 95 100 105
Produced with a robust, high density top temperature)
Thickness 110 115 120 125 130 135
surface, the products therefore exhibit (mm)
excellent point load compressive •Absorption of water after an complete
resistance. The dual density roofing immersion: 7/9% to 20ºC after 7 days of Thickness 140 145 150 155 160
(mm)
boards are manufactured with a high saturation. It returns at initial weight in
density. The panel is coated with a layer 48 hours.
of bitumen. •For other dimensions, consult us.
Water resistivity
Application The resistance to the water vapour is Installation
Heat insulation and acoustic in metal or negligible, similar al of the air μ1.4. -Hardrock should be laid with staggered
concrete flat roofs. joints wherever possible and tightly
Fire reaction butted to avoid gaps.
Advantages Panel classified like combustible. - The number of bindings by board
•Faster to install. Euroclass: F depends on the height of the cover and
•High mechanical benefits. of the type of waterproofing.
•Excellent resistance to the point load. Stability dimensional -In the case of the waterproofing sheets
•Well-known improvement of the sound Being made from rock, Hardrock is be set mechanically and directly on the
insulation. dimensionally stable and therefore: backup, it only will be necessary a
•Neither-hydrophilic nor hygroscopic. a)do not require any mechanically fixation by each stone wool board.
•Chemically inert- fasteners to prevent differential thermal
•Free of CFC and HCFC, respectful with expansion. Maintenance
environment. b)do not exert any undesirable stress on The boards don’t need any type of
. the waterproofing membrane. maintenance.
•Coefficient of lineal thermal
Technical caractheristics enlargement: 2x10-5 ºC-1. Packing
Nominal density The boards are supplied in packages or
140-210 Kg/m3 •Residual retention to 20ºC after 4 days in single panels.
to 70 ºC: imperceptible.
Specific heat Generalities
0.84 KJ/Kg K to 20º C •Dimensional variation with an The values specified in the present data
environmental stabilization to 20ºC sheet are medium values obtained in
Thermal conductivity between 65% and 80% of relative tests. Rockwool reserve the right in
0.039 W/(m*K) humidity: every moment and unexpectedly to
According to UNE 92201-UNE 92202 - Longitudinal direction <1%. notice to modify the specifications of its
- Cross direction <1%. products.
Thermal resistance
Acoustic Insulation
Thickness Hardrock boards provide effective sound,
(mm) 50 55 60 65 70 75 an essential requirement where
R(m2 K/W)
commercial or industrial operations
1.25 1.40 1.50 1.65 1.75 1.90 generate noise, at levels which could be
harmful to the health or efficiency of
Thickness
(mm) 80 85 90 95 100 105 building occupants, or present
environmental nuisance.
R(m2 K/W) 2.05 2.15 2.30 2.40 2.55 2.65
Consult the manual of insulation.
Thickness 110 115 120 125 130 135
(mm) Compression strength
R(m2 K/W) 2.80 2.90 3.05 3.20 3.30 3.45 Compression strength for a deformation
of the 10% ≥ 50 KPa.
Thickness 140 145 150 155 160
(mm)
Resistance to the point load at 500 KPa.
The upper layer of high density
R(m2 K/W) 3.55 3.70 3.80 3.95 4.10 contributes a greater resistance to the
point load thanks to the best distribution
of al load on the totality of the board.