MARWADI UNIVESRITY

Faculty of Technology
(Electrical Engineering)
B.E. SEM: 5 Subject: - Electrical Machine-II (01EE0503)

___________________________________________________________________________

Assignment (Synchronous Machines)


Q-1 Derive the emf equation of an alternator.

Q-2 What is Distribution factor? Derive the formula of distribution factor of alternator.

Q-3 What is synchronization in case of alternator? Explain two bright one dark lamp method of
synchronization.
Q-4 Define voltage regulation of an alternator. List out the methods to find out the voltage regulation of
the alternator. Explain any one in detail.
Q-5 Define and describe the effect of armature reaction in an alternator.

Q-6 A given 3 MVA, 50 Hz, 11 KV, 3 phase, star connected alternator when supplying 100 amp. at zero
power factor leading has a line-to-line voltage of 12,370 Volts; when the load is removed, the
terminal voltage falls down to 11,000 Volts. Calculate the regulation of an alternator when supplying
full load at 0.8 P.F. lag. Assume an effective resistance of 0.4 Ω per phase.
Q-7 Calculate the RMS value of the induced emf per phase of a 10 pole, 3 phase, 50 Hz, alternator with 2
slots per pole per phase and 4 conductors per slot in two layers. The coil span is 150 degrees. The
flux per pole has a fundamental component of 0.12 Wb.

Prof. Atul Kunpara Prof. Amit Ved


Subject Incharge H.O.D
Dept. of Electrical Engg. Dept. of Electrical Engg.
MEFGI, Rajkot MEFGI, Rajkot