This document contains a customer data sheet for a potential solar power plant project. It requests personal information about the customer as well as technical details about their site, existing energy infrastructure, load requirements, and expectations for the project. Key technical information sought includes load details, available space for modules, backup needs, grid/generator sources, and certifications required. Load charts are also included to provide details on specific equipment power needs.
This document contains a customer data sheet for a potential solar power plant project. It requests personal information about the customer as well as technical details about their site, existing energy infrastructure, load requirements, and expectations for the project. Key technical information sought includes load details, available space for modules, backup needs, grid/generator sources, and certifications required. Load charts are also included to provide details on specific equipment power needs.
This document contains a customer data sheet for a potential solar power plant project. It requests personal information about the customer as well as technical details about their site, existing energy infrastructure, load requirements, and expectations for the project. Key technical information sought includes load details, available space for modules, backup needs, grid/generator sources, and certifications required. Load charts are also included to provide details on specific equipment power needs.
Sl. Name No 1 Contact Person 2 Contact Number(Mobile)
3 Contact Number(Landline) 4 Email Address
5 Website Address
6 Address
7 City 8 State
9 Already a solar user(Y/N)
10 If above is yes then which company and
product 11 Budget of the customer
12 Time line of customer to execute project
13 PV solution required for : Residential /
Education Institute / Hospital / Defense/ Petrol pump/ Bank/Others etc. 14 Customer’s reason to go for a solar solution. Technical Information:
S.No Particulars Remarks
1 Load Details Complete with Power factor
Consideration 2 Type ( Single and Three Phase) 3 Hours of backup required 7 Latitude and Longitude 8 Wind speed in particular area 9 Shadow free Space Available (Y/N) Ground Mounted (Sqr mtr/sqr Feet) Roof Top (Sqr mtr/Sqr Feet) Level of floor for module mounting i.e 1st /2nd/3rd… etc 10 Control Room Specification Size Flooring (Cemented/non cemented ) Roof (Cemented/non cemented ) 11 Source Of power ( Gen-set /Grid) 12 Grid Available (Y/N) 13 Grid Type(Single / Three Phase) 14 Hours of Availability of Grid (Approx) 15 Time of grid Available 16 Gen-set rating if available 17 Type of Gen-set (Single /Three Phase) 18 No. Of hrs DG set used Avg. in a Day 19 Distance Between Panel and Control room 20 Autonomy required (Y/N) 21 If Autonomy required then specify No of days 22 Expectations 23 Copy of Grid Bill attached(Y/N) 24 Data logging required (Y/N) 25 Remote data monitoring required (Y/N) 26 Certifications required Load Chart (Single Phase)
S. Application Numbers Load Hours of Time of Power
No. Wattage backup operation Factor (VA) (a.m./p.m.) 1 Light Load 2 Fan Load 3 Drinking water Jet Pump load 4 Computer/ IT Deptt. Load 5 6 7
Load Chart (Three Phases)
S. No. Application Numbers Load Hours of Time of Power