Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
AMIMS-G-3104
Centrifugal Pumps
“Any modification on the AMIRAL standard is not retroactive and does not require implementation
or modification to existing facilities.”
This standard defines the minimum mandatory requirements for designing and manufacturing heavy
duty centrifugal pumps for Company.
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 1 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
Table of Contents
1 Scope......................................................................................................................................... 4
2 Conflicts, Deviations and Clarifications ..................................................................................... 4
3 References ................................................................................................................................. 4
4 Definitions................................................................................................................................. 5
5 Introduction Note....................................................................................................................... 6
6 Basic Design.............................................................................................................................. 6
7 Accessories .............................................................................................................................. 19
8 Inspection, Testing and Preparation for Shipment..................................................................... 26
9 Specific Pump Types ............................................................................................................... 29
Appendix A – Material Selection Guide........................................................................................... 31
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 3 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
1 Scope
1.1. This standard defines the minimum mandatory requirements for designing and
manufacturing heavy duty centrifugal pumps for Company.
1.2. This standard sets the rules and basis for selecting the applicable Company
Engineering Standards and/or Material Specifications that supplement the applicable
Codes.
1.3. This specification governs in its core requirements for sealed pumps according API
610 11th edition. However, sealless pumps can be proposed and shall be
manufactured according API 685 2nd edition and AMIMS-G-3105.
2 Conflicts, Deviations and Clarifications
2.1 Any conflicts between this standard and other applicable Company Engineering
Standards (AMIES), Material Specifications (AMIMS), Standard Drawings
(AMISD), Engineering Procedures (AMIEP), Company Forms or Industry
standards, specifications, Codes and forms shall be brought to the attention of
Company Representative by the Contractor for resolution.
Until the resolution is officially made by the Company Representative, the most
stringent requirement shall govern.
2.2 Where a licensor specification is more stringent than those of this standard, the
Licensor’s specific requirement shall apply.
2.3 Where applicable Codes or Standards are not called by this standard or its
requirements are not clear, it shall be brought to attention of Company
Representative by Contractor for resolution.
2.4 Direct all requests for deviations or clarifications in writing to the Company or its
Representative who shall follow internal Company procedure and provide final
resolution.
3 References
The selection of material and equipment, and the design, construction, maintenance,
and repair of equipment and facilities covered by this standard shall comply with the
latest edition of the references listed below as of the CUT-OFF DATE as specified
in the Contract unless otherwise noted.
3.1 Company References
3.1.1 Company Material Specifications
AMIMS-G-1301 Special Purpose Gear Units
AMIMS-G-1303 General Purpose Gear Units
AMIMS-G-3112 Shaft Sealing Systems for Centrifugal and Rotary Pumps
AMIMS-G-3113 Lubrication, Shaft Sealing and Control Oil Systems
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 4 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 5 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
5 Introduction Note
The API 610 "Centrifugal Pumps for Petroleum, Petrochemical and Natural Gas
Industries" and its appendices - eleventh edition, September 2010 is considered as
part of this specification.
The API paragraph numbers are indicated in parenthesis.
Only those paragraphs of the API 610 standard which have been deleted, completed
(Addition), totally modified (Substitution) or partially modified (Clarification) by
the present specification are mentioned. The other paragraphs of the API 610 which
are not mentioned remain applicable.
Those paragraphs that do not refer to an API 610 paragraph numbers are additional
paragraphs.
Mechanical equipments to be used in hazardous area shall be selected in accordance
with the area where they will be installed.
6 Basic Design
6.1 (6.1) General
6.1.1 (6.1.3) (Clarification)
When the specific gravity of any of the fluids being pumped is less than 1, at any
pumping temperature applicable to that fluid, the vendor shall ensure that the pump
and its accessories shall be able to operate without deterioration during the
performance test with water. Performance tests at reduced speeds shall require
Purchaser written approval prior to any purchase order.
6.1.2 (6.1.4) (Clarification)
The proposed rated impeller diameter for pumps with constant speed drivers shall be
no greater than 95% or less than 80% of the maximum impeller diameter that can be
installed in the pump casing.
For pumps with variable speed drivers, the impeller diameter giving the maximum
efficiency shall be selected. If this results in the selected impeller diameter being the
maximum for the chosen casing, then the driver and pump shall be capable of the
speed increase necessary to give a 5% increase in head (per API 610 clause 6.1.4)
and to correct any head shortfall during testing, including the tolerance per API 610
table 16.
For overhung impellers the tip speed of the selected impeller, at the rated operating
point, shall not exceed 62 m/s.
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 6 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
Maximum allowable
252 15100 13000
(all pumps)
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 7 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 8 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
Page 9 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 10 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 11 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
Page 12 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 13 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
Supporting and surrounding structural elements that are in the Vendor’s scope of
supply shall not be excited by the pump when it is operating at any point in the
allowable operating region.
6.9.2 (6.9.2.1) (Clarification)
The Vendor shall perform a torsional analysis of the entire shaft line in one of the
following cases:
− It is a contractual requirement.
− The rated power of the driver is greater than or equal to 1000 kW.
− The shaft line has more than two machines.
− There is a variable speed prime mover.
The pump Vendor shall be responsible to obtain all necessary information from the
vendors of the other train components to perform this analysis. In the event that these
vendors are not the pump Vendor's own sub vendors, an agreement shall be reached
during the contract negotiations.
6.9.3 (6.9.2.10) (Clarification)
When a torsional analysis is specified or required for any motor driven pump train,
transient and steady state conditions shall be evaluated. Transient conditions include
short circuit between two phases, start-up and, if specified, re-acceleration. A stress
analysis shall be performed for the transient conditions to ensure that shaft-end,
coupling and drive-component ratings are not exceeded.
6.9.4 (6.9.2.10) (Clarification)
The report will be supplied in all cases where a torsional analysis is carried out.
6.9.5 (6.9.3.3) (Clarification)
The FFT plotted spectra shall be included in the pump test results.
6.9.6 (6.9.3.6) (Addition)
At any flow within the pump's preferred operating region, the overall velocity shall
not exceed 4.5 mm/s (0.18 in/s) RMS.
Vibration measurements shall also be taken on the driver, adjacent to the upper
bearing for pumps with rigid coupling.
6.9.7 (6.9.4.4) (Clarification)
Impellers and balance pistons and similar rotating components shall be dynamically
balanced to ISO 1940-1 grade G1. API 610 Clause (6.9.4.2) may be used if
applicable.
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 14 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
Page 15 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
The bearing casings of pumps driven by steam turbines and/or equipped with
mechanical seals with a permanent steam quench; shall be equipped with a water
trap in the lower half, with a visible level indicator.
This trap design shall be equipped with a drain valve with a safety lock (locked in
the closed position).
6.10.6 (6.10.2.4) (Addition)
Maximum bearing temperatures shall comply with the following requirements:
− The metal temperature of ring oil lubricated bearings shall not exceed 85°C in
the loaded area, based on a maximum ambient temperature of 50°C. If bearing
metal temperature monitoring is not practical, the sump oil temperature shall be
measured and, during shop testing, the sump oil temperature rise shall not
exceed 35°C;
− The metal temperature of bearings lubricated by external oil circulation or
forced feed lubrication systems shall not exceed 95°C in the loaded area, based
on a maximum oil inlet temperature of 60°C. During shop testing, the
differential between the bearing loaded area metal temperature and the actual
oil inlet temperature shall not exceed 35°C.
6.10.7 (6.10.2.6) (Clarification)
Replaceable bearing isolator seals shall be magnetic sealing type or AMIRAL
approved equal.
6.10.8 (6.10.2.11) (Clarification)
This clause applies. These machined surfaces are required for each machine,
including driver and any gear or speed variation unit. For equipment where this is
not feasible such as the non-drive end of electric motors another system such as an
extension bar shall be fitted to the bearing housing to permit vibration measurement.
6.11 (6.11) Lubrication
6.11.1 (6.11.4) (Clarification)
Rolling element bearings for pumps shall be oil lubricated.
6.12 (6.12) Materials
6.12.1 (6.12.1.1) (Clarification)
Appendix B of this specification, which complements API 610 Table G1, applies.
The use of 12% Cr martensitic steels such as ASTM A217 grade CA15 is prohibited
for cast casings due to weld repair difficulties; only ASTM A487 grade CA6NM
steel may be used.
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 16 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
Page 17 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
Page 18 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
The fabrication drawings with details of the welds, the complete welding dossier and
the verification list shall be submitted to AMIRAL for approval prior to
manufacture.
All casing components manufactured according to this clause shall undergo a post-
weld heat treatment regardless of dimensional stability requirements.
6.12.13 (6.12.3.4.a)) (Clarification)
Weld neck flanges shall be used for non flammable or non hazardous nozzles.
6.12.14 (6.12.3.4.d)) (Clarification)
Connection designs for fabricated pressure casings shall be approved by purchaser
before manufacturing.
6.12.15 (6.12.3.4.e) (Clarification)
All auxiliary connection welds, including any seal welds, shall undergo magnetic
particle or liquid penetrant examination. If feasible a radiographic examination shall
also be carried out to ensure correct fit-up of socket welded connections and thread
engagement of seal welded NPT connections.
6.12.16 (6.12.4.3) (Clarification)
Impact testing shall be performed in accordance with EN 13445 or ASME VIII Div.
1, Paragraph UG84.
6.13 (6.13) Nameplates and rotation arrows
6.13.1 (6.13.2) (Clarification)
Pump nameplate data shall also include the Purchase Order number, liquid pumped,
lubrication details and shaft lift (for vertical pumps).
6.13.2 (6.13.4) Clarification)
Nameplates and rotation arrows shall be of austenitic stainless steel or of nickel-
copper alloy (Monel or its equivalent). Attachment pins shall be of the same
material. Welding is not permitted.
7 Accessories
7.1 (7.1) Drivers
7.1.1 (7.1.4) (Clarification)
The nameplate rated power including service factor (if any) of electric motors shall
be the greater of the two following values:
− Power determined as per API 610 table 12. The Rated power of the pump to be
taken into account being the power absorbed at the rated point, plus the API
allowances per Table 16, plus the expected power absorbed by any intermediate
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 19 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
machine (e.g. gear). If any specified operating point absorbs more power than
the rated point, then this higher power shall be used in the above calculation
instead of the power absorbed at the rated point.
− Maximum power absorbed by the pump with the selected impeller at the
maximum specified specific gravity, up to and including the end of the
allowable operating region of the curve that was agreed prior to the order.
Electric motors shall comply with relevant project specifications, as specified on the
motor data sheet.
7.1.2 (7.1.6) (Clarification)
Unless otherwise specified, motors for pumps with “open valve” or “open circuit”
start up shall be capable of accelerating the pump to rated speed assuming circuit
resistances curve running from zero through the maximum allowable flow, or 120%
of BEP which ever is the greater, at 80% of the nominal motor voltage. The
separation between the motor and pump speed torque curves shall never be less than
10% of the rated torque.
7.1.3 (7.1.10) (Substitution)
Increaser and/or reducer gears ears with a nameplate power greater than or equal to
1000 kW shall comply with AMIMS-G-1301 "Special purpose gear unit".
Increaser and/or reducer gears ears with a nameplate power less than 1000 kW shall
comply with AMIMS-G-1303 "General purpose gear unit".
7.1.4 The following technologies for motor driven variable speed machine meet the
requirements from Company:
Variable Frequency Drive (VFD)
Variable Speed Gear Box
Electrically controlled variable speed planetary gear box
7.1.5 Technology selected for each application is indicated in equipment data sheet. For
motor driven-machines in variable speed application with rated power greater than
1 MW, CTR can propose different technology for Company review and approval
based on a technical-economic assessment which shall include at least the following
criteria:
Reliability
Capex cost
Efficiency and Energy saving
Equipment Footprint
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 20 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 21 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
Keys shall fill the keyway in the shaft and hub. Any part of the key protruding shall
be machined flush with the shaft.
Prior to delivery the vendor shall establish, for purchaser witness, a balance dossier
including all relevant balance certificates of rotors, shafts and couplings to
demonstrate a consistent philosophy regarding filling keyways during balancing of
the individual components by different sub vendors.
Keys and half keys shall meet the requirements of ISO 21940-32 including marking
of keys and shaft ends with the applicable key convention.
7.2.5 (7.2.6) (Clarification)
Shaft-end drawings indicating machining tolerances shall be included in the
Operating, maintenance and technical data manual.
The assembly of half couplings shall be such that a temperature of less than 120° C
is required for removal.
Locking by means of self-hardening products is prohibited.
Shaft ends shall not be set back in the bored area of the half couplings.
7.2.6 (7.2.13) (Addition)
Coupling guards shall have provisions to permit inspection of flexible elements. All
coupling guards for pumps, with the exception of integrally geared pumps, in
hydrocarbon service shall be of a non-sparking material such as aluminum or brass.
If totally enclosed coupling guard is provided, drain connection shall be provided
for the coupling guard.
7.3 (7.3) Baseplates
7.3.1 (7.3.1) (Substitution)
The drain pan shall be sloped at least 1:100 towards the pump end.
As a minimum, EN 10025 S235 J2G3 steel shall be used. The option of impact
testing shall be taken for ambient temperature below –20°C.
Welds shall be subject to100% Dye Penetrant per table 13 inspection standards.
Baseplates made from cast iron or folded or stamped plate are unacceptable.
7.3.2 (7.3.5) (Addition)
Pump pedestals shall be supplied with water-cooling when the temperature of the
pumped fluid is greater than or equal to 250° C. If the project specification specifies
no pedestal cooling and the temperature of the fluid is greater than 250°C, provision
for cooling shall be supplied.
7.3.3 (7.3.10) (Clarification)
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 22 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
All baseplates will be epoxy grouted. Baseplate grouting holes will be accessible
without removing the machinery.
7.3.4 (7.3.13) (Clarification)
All baseplates will be mounted with grouting.
7.3.5 (7.3.17) (Clarification)
All drive train components shall be fitted with transverse and axial alignment
jackscrews. The lugs shall be attached in such a way that they do not interfere with
the installation or removal of the shims.
7.3.6 (7.3.18) (Clarification)
When base frame fixing holes are made in a non-parallel profiled wing, tapered
shims shall be welded onto the wing at each anchor bolt position.
7.3.7 (Addition)
For double casing vertical pumps weighing more than 100 kg, the baseplate shall be
equipped with leveling jackscrews. Machined surfaces shall be supplied for
verification that the pump train is vertical. Horizontal positioning screws shall be
provided.
The baseplates and/or the support cages shall include lifting lugs.
7.4 (7.4) Instrumentation
7.4.1 Instrumentation shall be in accordance with specification AMIMS-J-4831 “Package
Unit Instrumentation” and AMIMS-J-4625 “Machinery Protection Systems
(Vibration, Axial position and bearing temperature monitoring system)”
7.4.2 (7.4.2.1) (Clarification)
Pumps equipped with anti-friction radial bearings and having driver ratings above
110 kW (150 HP) shall be provided with one seismic vibration transducer reading
velocity on each bearing housing in radial direction.
Pumps equipped with anti-friction thrust bearings and having driver rating above
110 kW (150 HP) shall be provided with one seismic vibration transducer reading
velocity on each bearing housing in axial direction.
For vertically suspended pumps having driver rating of 110 kW (150 HP) or above
and are not equipped with thrust bearings, two seismic sensors shall be provided on
the thrust bearing housing of the driver. One sensor shall be oriented in the direction
of the discharge nozzle axis, and the other at 90 degrees to that direction. For
vertically suspended pumps having same power rating as above and are equipped
with thrust bearings, two seismic sensors with same orientation as above shall be
installed on the pump thrust bearing housing.
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 23 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 24 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
− Piping to the seal gland shall be supported such that the screwed connections
into the gland are not subject to forces due to expansion, vibration or other
movement of the piping or auxiliary equipment to which that piping is attached.
The vendor may chose to meet this requirement by the use of gussets (see paragraph.
6.4.4 of this specification) or pipe supports or a combination of both.
If supports are chosen these supports must allow the pipe lengths to expand and
contract without causing loads on the casing connections.
To ensure satisfactory accessibility, Vendor shall supply, in sufficient time,
drawing(s) of equipment and piping layout for review by the Purchaser. Fabrication
of baseplate and piping shall not commence until agreement has been reached
regarding an acceptable layout. Approval of layout will not alleviate the vendor of
his responsibilities to meet the applicable specifications.
7.5.4 (7.5.1.6) (Clarification)
Drains and vents shall be equipped with a gate valve. If the specification for the
piping connected to the pump calls for double block valves, this requirement shall
apply to vent and drain valves. If a pump has several drains or vents each shall have
a separate valve.
After the gate valve, pump casing drains shall be run to a manifold and then to the
skid edge terminating with a flanged connection.
Unless otherwise specified, for pumps specified for liquids that are toxic or
inflammable or have a pumping temperature greater than 60°C, each vent shall have
a flanged connection after the gate valve. This connection shall be routed to a closed
drain or flare system.
For other liquids, each vent shall have a connection after the gate valve for
disassembly and then be run to the drain pan. The end of the pipe shall be fitted with
a flange and blind flange in accordance with the applicable piping specification.
7.5.5 (7.5.1.7) (Clarification)
Flange fasteners on stainless steel piping shall be stainless steel.
7.5.6 (7.5.2.1) (Clarification)
Auxiliary process piping arrangements shall conform to API 610 Annex B.
Vendor shall supply the expected seal chamber pressure and a calculation to
demonstrate that this seal chamber pressure will be maintained to within the limits
set in API 682 4th edition.
7.5.7 (7.5.2.2) (Clarification)
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 25 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
Auxiliary process fluid piping class shall be that of the pump discharge piping. The
discharge pipe class shall be specified on the data sheet.
7.5.8 (7.5.2.3) (Clarification)
When the pump casing is 12% chromium, the auxiliary process fluid piping shall be
in 316L or 321stainless steel.
7.5.9 (7.5.2.6) (Clarification)
Vent and drain connections shall always be fitted with valves.
7.5.10 (7.5.2.8) (Clarification)
Union connectors may only be used for piping containing flammable or hazardous
fluids when it can be demonstrated that flanges cannot be used. The acceptance of
any union connectors shall be subject to AMIRAL written approval.
Screwed piping into mechanical seal glands shall be straight.
All screwed piping connected to the mechanical seal shall be provided with lap joint
flanges installed at the connection with the flushing piping. The lap joint can be
installed on the piping into the mechanical seal or on the flushing system piping.
Screwed piping into mechanical seal glands shall be such that self-griping wrenches
need not be used. Screwed piping damaged by such wrenches is not acceptable.
7.5.11 (7.5.3.1) (Clarification)
On thermosyphon systems the positioning of cooling water piping shall be such that
the water enters at the bottom and exits from the top of the cooling chambers.
7.5.12 Lubricating oil line when oil pressurized systems is used: Piping, connections and
flanges shall be in AISI-TP 316 L stainless steel.
8 Inspection, Testing and Preparation for Shipment
8.1 (8.1) General
8.1.1 (8.1.5) (Clarification)
This section applies. The checklist shall be signed and dated by both the Vendor and
Purchaser representatives prior to release of the equipment for expedition.
The API 682 checklist shall be signed and dated by the Vendor representative and
shall be available for review at the same time as the pump checklist.
8.2 (8.2) Inspection
8.2.1 (8.2.2.1) (Clarification)
Radiographic examinations of pressure retaining castings shall be performed for the
following services:
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 26 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
Page 27 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
Page 28 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 29 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
ISO 1940 G6.3 the components shall be disassembled and reworked individually to
reduce the residual unbalance of the assembly to below G6.3. No attempt shall be
made to obtain the G6.3 residual unbalance of the complete assembled rotor by
balancing the assembly or the coupling on the rotor.
9.3 (9.2.2.3) (Clarification)
Impellers for all multistage pumps shall be individually secured against axial
movement in either direction. Vendor shall submit, in the proposal, a drawing
showing attachment method.
9.4 (9.2.5.2.4) (Clarification)
The thrust bearing size shall be reviewed by Purchaser.
9.5 (9.2.6.2) (Substitution)
External pressure lubrication systems shall comply with AMIMS-G-3113 part 3 for
pumps with driver nameplate power less than 1000 kW.
External pressure lubrication systems shall comply with AMIMS-G-3113 part 2 for
pumps with driver nameplate power higher than or equal to 1000 kW.
9.6 (9.2.7.5) (Clarification)
Hydrodynamic bearings shall be removed and inspected after test.
9.7 (9.3.8.3.2) (Clarification)
A minimum of four alignment-positioning screws shall be provided for each drive
train component regardless of weight.
9.8 (9.3.8.3.3) (Clarification)
Pumps shall be provided with separate soleplates with 25 mm (1”) minimum radius
corners for bolting and grouting to the foundation.
9.9 (9.3.13.5) (Clarification)
The suction will be supplied with a drain, piped to the surface.
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.
Page 30 of 31
SAUDI ARAMCO TOTAL PETROCHEMICAL COMPLEX
Issuer: PMT
July 2021
Centrifugal Pumps Rev: 4
AMIMS-G-3104
Fresh water, condensate, cooling tower water < 100 I-1 or S-1 1
Foul water and hydrocarbons containing these waters < 120 S-3 3
120 to 170 S-6
Corrosive hydrocarbons containing Chlorides and/or Sulfides (DAT, HDT, < 150 S-5 3
DGO...) 150 to 260 S-6
> 260 C-6
Notes
1) Pressure casing in SG ductile iron. (EN 1563).
2) Pressure casing in Ni resist ductile iron (ASTM A 439)
3) Impeller in Ni resist ductile iron (ASTM A 439)
4) All welds shall be stress relieved
5) Type 316L with Mo > 2.5 %
The present document or drawing is property of SAUDI ARABIAN OIL COMPANY and TOTAL RAFFINAGE CHIMIE S.A. and
shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically furnished or
outside the extent of the agreed upon right of use.