History : We would like to guide the customer to replace any foreign substances, etc. on the camera window in a
AOD machine Disassembly Vacuum Pad assy Vacuum Pad assy Air T-Type pitting
(base) Stick (base) 10PI (GH81-20269A) 8PI (GH81-20270A) (GH81-20210A)
image
◆ Disassembly
3. Check the point to be disassembled and Assemble the appropriate jig to the machine (AOD)
* The example below is a P project ( S21 ) . For other models, please insert the vacuum PAD in accordance
3-1. Remove the 2-point hose and connect the air T-type fitting part.
3-2. Remove the 1-point hose and connect it to the air T-type fitting.
3-3. Connect the appropriate Vacuum pad jig for each model.
4. Change the setting of the machine before adsorption to the following conditions.
5. Turn the phone over and place the vacuum pad on the disassembly point for more than 30 seconds
6. If there is a gap, use a disassembly tool to lift it up.
※ Precautions
- If you insert the disassembly tool deeply, there may be damage to the camera, so please insert it slowly to
a minimum.
◆ Assembly
1. Attach the camera window tape and press the edge of the tape with tweezer.
(Do not touch the center of the tape to prevent damage to the camera lens)
※ Precautions
- Before attaching the camera window tape, check if there is any remaining tape residue or foreign matters.
And then press the camera window carefully with hand several times.
- revision history