You are on page 1of 21

SP-ST

Shanghai Sumpo Electric


SP6000-F3 micro control system
lift control cabinet electric drawings

Please read this manual carefully so that when you have any questions , it can help you. Thank you for using
Contents

Schematic Diagram
Page1: main control circuit
Page2: power supply circuit
Page3: main board wiring diagram
Page4: inspection circuit
Page5: car board wiring diagram
Page6: car call button wiring diagram
Page7: Hall call board wiring diagram
Page8: safety,doorlock circuit
Page9: brake circuit
Page10: light circuit
Page11: interphone circuit
Page12: door machine wiring diagram
Page13: UPS control circuit
Page14: parallel and group control wiring diagram
Page15: Advanced door-open circuit,re-leveling circuit
Page16: system diagram
Page17: component code table 1
Page18: component code table 2
1 2 3 4

L11 L12 L13 N PE


inverter brake resistance diameter of main suitable
model value BR power KM0、 KM1 Fuse circuit wire motor
HZ 45P5 100~39Ω 1.0KW SC-5-1 or GMD-22 3P/4P 20A 4mm 2 5.5KW
D 47P5 75~39Ω 1.5KW SC-5-1 or GMD-22 3P/4P 30A 6mm 2 7.5KW D
4011 50~26Ω 2.0KW SC-N1 or GMD-32 3P/4P 50A 6mm 2 11KW
4015 40~26Ω 2.5KW SC-N2 or GMD-40 3P/4P 60A 8mm 2 15KW
L21
1
L22 N1 4018 32~20Ω 4.0KW SC-N3 or GMD-50 3P/4P 75A 10mm 2 18.5KW
2
KXX 3 L23 4022 20~18Ω 6.0KW SC-N4 or GMD-65 3P/4P 85A 15mm 2 22KW
4030 16~13Ω 9.6KW SC-N4 or GMD-80 3P/4P 100A 15mm 2 30KW
1 3 5
KM0
2 4 6
main input contactor BR

C C
R S T B2 B1

SP6000-F3 integrated controller


PG-02 PG-01
1 2 3 4 5 6 7 8 9101112131415 1 2 3 4 5
U V W E

KM1
1 3 5
main output contactor
B
2 4 6
Notice: B

KM1 1.The diameter of the wire connected to close point on


61 62
U1 contactor KM1 must be 2.5mm.

12V
B-
C+
C-
A+
A-
GND
B+
+5V
SIN+
SIN-
COS+
COS-

A+
0V

A-
V1
71(51) 72(52)
W1
2. stand for terminal which is still electrified after the
cabinet powered off.
Ifwe use FUJI contactor,the wiring in the dotted line is necessary;
U V W 3.Choose either of two PG cards.
12V

Ifwe use self-locking contactor,do not connect the wire in the dotted line;
2a

1a
7b
2b

A+
B+
5a
4b
4a
6b
3a
3b
7a

6a

0V

Ifwe use asynchronous motor,do not connect the wire in the dottedM line.
4. Power wire shield layer,encoder wire shield layer,controller
shell and motor shell all connect to PE.
A A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 main control circuit page: 01
1 2 3 4
1 2 3 4

D BY D

Connect these wires when brake voltage is DC110V


DZ1 F3(4A)
F1(4A) A101 D100 D101+
A100
~ +

110V/350VA DC110V
A111 _ D100-
~

C C
RB1(2P/6A)
Connect these wires when brake voltage is DC220V
DZ2 F3(4A)
L21 U21
D220 D220+
~ +
DC220V
_ D220-
~
L22 U22

B B
WY1
F2(4A) 24V+
B200 B201
L 24V+
220V/350VA E DC24V
Note: stand for terminal which is still electrified 14 13
N 24V-
KSA
B220 24V-
after the cabinet powered off 220V/800VA(when the brake voltage is 220V)

A A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 Power supply circuit page: 02
1 2 3 4
B
C

A
D
A1 A2

Check
Design
connect with line when weighting equipment

J6. 4
X34-
i s i nstalled in hte end of rope

KSA
RC

KCZ

CZ
24 V-(0V)

over load

J6. 3
X28
J5. 8

X34+
J7
KMZ
A2

MZ
A1

J6. 2
X33-
full load

X27
J5. 7

KMS

1
1

KQZ

safety circuit high pressure detection


RC

QZ
under load

X26
J5. 6

Audit
PTC

1 2

Approval
KM1
X33+ Y16
motor overheat protection

J6. 1 J19. 3

A2
A1
X25
J5. 5
fire signal and lock lift signal also can col lect by base
1
landing cal l board, main control board
2 have priority

3
lock lift
ST

door lock circuit high pressure detection


RC
1

J19
2

KMS
X24 X23
fire
J5. 4 J5. 3

44
43
XF

K BZ
Y15
J19. 2

4 3
A1

A2

KM1
re-level ing
X22

KSA
J5. 2
SQP

4
RC
J5
A1-7
D7-5

AD1 -7

pre-open door JP1. 6


X21
J5. 1

K ZD
COM7 Y14B
connect with line when lift speed>=4. 0m/s

J19. 1 J18. 6

A2
A1

14
8KW

1 2

KM0
down forced deceleration 3

Date
X20
J4. 8

Technics
Y14A
J18. 5

RC

13
7KW

A1 A2 up forced decel eration 3 1 2


X19
J4. 7

Y13B
J18. 4

A111
KM0
J18
emergency run 1 2
X18

RC
J4. 6

2
2

brake detecti on 1 2

A101
XF C1 brake feedback 1 2
X17 X16
J4. 5 J4. 4

fire return back to base station


UPS BZS KBZ

XFC2 Y13A Y12B Y12A 21 22


J18. 3 J18. 2 J18. 1

2010. 04.12
main output feedback
X15
J4. 3

J15. 8 J4
inverter reset 21 22
main input feedback
X14

J15. 7
J4. 2

Y7 Y6

inverter enabling
KM1 KM0
SQD

PS

J15. 6
Y5

multi-section speed 3 lower leveling


X13
J4. 1

multi-section speed 2 J15. 5


Y4
D7-6
D7-8

J15
A1-12
PZ

J15. 4
Sumpo SP6000-F3 lift 32 bit control system

Y3

multi-section speed 1 upper leveling


X12
J3. 8

upgoing J15. 3
SQU
D7-4

A1-11

J15. 2
Y2 Y1
AD1 -1 2 AD1 -1 1

downgoing i nspection downgoing signal 814

inverter switch val ue input si gnal


invert er input com mon port
J15. 1 COM4 inspection upgoing signal 813
connect with line when lift speed>=2. 0m/s
J14. 3 812
X11 X10 X9

analog common port i nspecti on signal


J3. 7 J3. 6 J3. 5

COM3
J14
S1W
6KW

B2-2

J14. 1 down forced decel eration 2


X8

0-10V VD
J3. 4

J6. 5 J3
B 2-1

24V+ COM2

3
S2W
3

B 2-3

J6. 3
4KW

inverter zero speed X31


X7

J6

up forced deceleration 2
J3. 3

inverter fault J6. 2


X30
inverter run J6. 1
X29
S3W
B 2-4
5 KW

variable frequency drives


X6

output signal common port 24V-(0V) down forced deceleration


J3. 2

analog signal inverter output signal

J21. 3
24V+ COM1
S4W
B2-6
3KW

B phase pul se J21. 2 up forced deceleration


X5

J21

PB
J3. 1

A phase pulse J21. 1


PA
collector open circuit

coll ector comm on port 24V-(0V)


S5W
B 2-5
2KW

lower li mit
X4
J2. 5

Bphase- J20. 4 PB-


S6W

J20. 3
B2-7
1KW

Bphase+ PB+
X3

upper limit
J20
J2. 4

J20. 2
Aphase- PA-
inverter pulse output signal

J20. 1 1 2
safety feedback signal
X2

Aphase+
RS-422pul se output

PA+
J2. 3
KSA

1 2
TXCL3 J13. 2 door lock signal
CAN3L
J13
KMS

TXCH3 J13. 1
CAN3H
24 V+

A2-4 A2-3

J2
X1 COM V-

TXCL2 J12. 2
Main board control circuit
parallel group control

CAN2L
V-

4
4

J12

TXCH2 J12. 1
CAN2H
power input

A2-4 A2-3

Sumpo SP6000-F3 lift 32 bit control system diagram


V+ V+

TXCL1 J11. 2
24 V-(0V) 24 V+

CAN1L

back door landing call


J2. 2 J2. 1 J1. 4 J1. 3 J1. 2 J1. 1J8

J9

J11

J1
J10

TXCH 1 J11. 1
B3-4 B3-3
CAN1H

page: 03

connect with instruction board and landing call board


Version:V1.01

hand operator communi cation port remote monitor communication port


RS485 l anding call board communication port
B
C

A
D
1 2 3 4

D D

24V-

A1-6
SP6000-F3
ZD ZY ZF
AD1 -6
DX4 -8 827 817 812
J3.2X9
X4-8 X4-9 DX4 -9 AD1 -8 A1-8

C C
ZF 818 AFT 819 JFS 813 J3.3X10

JFX 814
J3.4X11
A1-9 A1-10

AD1 -9
828 829 AD1 -1 0
ZY AYT AYS X4-10

DX4 -1 0

AYX X4-11

DX4 -1 1

B B

ZD 838 ADT 839 ADS

ADX

A A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 Inspection wire connection page: 04
1 2 3 4
1 2 3 4

to connect wire only if weighting equipment mounted at car bottom


24V-
D1-9 D3-9
D6-2 D2-7 D4-7

D D

1KM 2KM 2GM 2AP


DIR VIP KMZ KCZ KQZ IGM 1AP VIP KYGMAN

D6-5 D6-4 D6-6


D1-10 D1-11 D2-6 D3-10 D3-11 D4-6
DX1 -1 4DX1 -1 3 DX1 -1 5
DX1 -1 0 DX1 -1 1 DX1 -1 2 DX2 -5 DX2 -6 DX2 -7
X1-14 X1-13 X1-15
X1-10 X1-11 X1-12 X2-5 X2-6 X2-7
JZS SK1 SG1 AP1 SK2 SG2 AP2 VIP KYG
SJ MZ CZ QZ
direct ru n
op erato r

de la y to c lose door button

Door op en2 bu tton


Door close2 bu tton
rea r door light bar
rea r door open limit
fullload

overload

rear door close limit


light bar
lightload

door ope n limit

door close limit


J1.1 J1.2 J1.3 J1.4 J1.5 J1.6 J1.7 J1.8 J2.1 J2.2 J2.3 J2.4 J2.5 J2.6 J2.7 J2.8
X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 X11 X12 X13 X14 X15 X16 1 1
2 2

de la y to close door button la mp

VIP
C 3 3 C
4 4

Door close button

Door open button


J1 0 J9
door close output
door open output

rear door close


rear door open

lighting mana gement


1 1
SP6000-F3-CB 2
3
2
3
4 4

in parking
J8 J7

buzzor
TY1 TY2 COM1 TY3 TY4 COM2 TY7 COM4 TY8 TY9 TY12 COM5 V- TXH TXL V+
J3.1 J3.2 J3.3 J3.4 J3.5 J3.6 J4.4 J4.9 J4.5 J4.6 J5.1 J5.2 J6.4 J6.3 J6.2 J6.1

KM1 GM1 CM1 KM2 GM2 CM2 BZ 24V+ BL DL JN 24V+ 24V- TXCH1 TXCL1 24V+

X2-2 X4-12
X1-7 X1-8 X1-6 X2-3 X2-1 X4-7
B DX4 -1 2 B
DX1 -7 DX1 -8 DX1 -6 DX2 -2 DX2 -3 DX2 -1 D8-10 DX4 -7

D1-7 D1-8 D1-6 D3-7 D3-8 D8-11 24V+


D3-6
FL TXCH SP5000F-HAX
KM1 GM1 CM1 KM2 GM2 CM2
DZL CH1 + JN
TXCL
COM - LED
to connect front door machine board GND

X3-2 X3-4 X3-3 X3-1


to connect rear door machine board
DX3 -2 DX3 -4 DX3 -3 DX3 -1
AD2 -2 AD2 -4 AD2 -3 AD2 -1
24V- 24V+ A2-2 A2-4 A2-3 A2-1

24V- TXCH1 TXCL1 24V+


A A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 car board wire connection page: 05
1 2 3 4
1 2 3 4

D D

1th floor 16th floor 17th floor 32th floor

L1X S1X L16X S16X L17X S17X Ln32 Sn32

C C

1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
CN1 CN16 CN17 CN32

J11 J11 SP6000-F3-CEB J12


SP6000-F3-CB
B B

A A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 Instruction button wiring page: 06
1 2 3 4
1 2 3 4

D D
LnX SnX L(n-1)X S(n-1)X L(n-1)X S(n-1)X L2X S2X L2X S2X L1X S1X LOOK FIRE

1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
C C
DN UP DN UP DN UP CN4 CN3

SP6000-F3-HAX SP6000-F3-HAX SP6000-F3-HAX SP6000-F3-HAX

+24V CANH CANL GND +24V CANH CANL GND +24V CANH CANL GND +24V CANH CANL GND
1 2 3 4 J1 1 2 3 4 J1 1 2 3 4 J1 1 2 3 4 J1

B B3-1 B
24V+
B 3-3
TXCH1
B 3-4
TXCL1
B3-2
24V-

A A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 Hall call board wiring diagram(485) page: 07
1 2 3 4
1 2 3 4

D D
KDS KDT2 KDT1 KJH KDH KSX KSJ A118 C 1-6 KXS KJX KAQ
A111 B1-9 BK-6 A114 B 1-10 C 1-7 A3-2AD3 -2 D8-4

A112 A113 BK-5 A115 A116 A117 A119 A120


JFS
B1-8

A134 ZD
D8-5
JFX A121
ZJ A132 ZF A131 A3-1 AD3 -1

C C
KAC KDT KXT KRP KFT KXX
D8-6 DX1 -4 X1-4 AD3 -3 A3-3 C1-8 C1-9 A126 A130

KSA
A1 A2

A122 A123 X1-5 DX1 -5A124 A125 UPS


RC SP6000-F3

D4-2
1KJM D4-1
KJM D2-1 AD3 -4 A3-4
D2-2 J6.4 X34-
AD3 -5 J102 J101 J6.3X34 +

J6.2X33-

B KTM1 1KTM1 KTM(n) 1KTMn T170 B

KMS
A1 A2 J6.1X33 +
B 1-1 T101 B1-2
A3-5 1T01 T1(n)
RC

A101

KSA J2.2 X2
2 1

KMS J2.1 X1
2 1
24 V-(0V)

A A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 safety,door lockcircuit page: 08
1 2 3 4
1 2 3 4

BZ1 BZ1 KZD DZZ KM1


D101+(D220+)
3 4 5 6 21 22 A63 A68 13(43) 14(44) D100-(D220-)
D D
brake contactor brake contactor RZ1 main output contactor
D1

Note: if the brake voltage of motor is DC110V,connect D101+ an D100- for brake circuit.
do the wiring if we need to RZ2
if the brake voltage of motor is DC220V,connect D220+ an D220- for brake circuit. change brake voltage
RZ1: 300W/ 100Ω RZ2:50W/50Ω

C BZ1 BZ1 KZD DZZ KM1 C


B201 A63 B220
3 4 5 6 21 22 A68 13(43) 14(44)

brake contactor brake contactor RZ1 main output contactor

do the wiring if we need to


Note: ifthe motor brake voltage is AC220V, do the wiring like this. change brake voltage
RZ1: 300W/ 100Ω

brake contactor
B BZ1 B
A101 21 22

overspeed governor JQ counter


B220
action A111 3 4

ZT B201
ZQ1 0003000
ZQ1 1 2
C1-11

ZF
FW
ZQ2 C 1-10 B201 B220
Inspection overspeed ZQ2
ZQ3 governor reset C1-12 ZQ
(in machine room)
A A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 brake circuit page: 09
1 2 3 4
1 2 3 4

200

A3-8

AD3 -8
D D
B 1-6
1
JN

DX1 -1 BK-3

X1-1 ZM4
203
RB3 KFS ZM ZM3
L13 DJR2
C2-1 X1-3
ZM2 DM4
C X1-2 C
DJR5
DX1 -3 DX1 -2
C2-2 DJR1
N1 205 204 DM3
D8-1 D8-3 DM2
FS1 DM1
do the wiring in condition
of no machine room KB-4
D8-2

AD3 -9
B 1-7

A3-9
B B
201
GM3 SBS C2-5 503 SBX
500 504
C 2-4
502
1.The number of lights in shaft(1JD-nJD) depend on the height of
shaft.It is required that there must be one light 0.5m away from the
1DJ 2DJ nDJ top and the pit.The interval of every two lights is 7m and the power
of each light must be over 60W.
2.AC220V socket must be three-hole socket.

C2-3

A 501 A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 light circuit page: 10
1 2 3 4
1 2 3 4

B 2-12

D D
A1-4 AD1 -4
1
B 2-11
2
A1-3 AD1 -3
pit

EMD

200 A3-8 AD3 -8


C D7-2 C
L
1
201 A3-9 AD3 -9 D7-1
E2 N 2
1 1

E1
2 2 car roof
DX4 -5 DX4 -6
401 + DX4 -2 X4-2
S1 S1
A1-1 AD1 -1 interphone
X4-5 X4-6
402 DC12V
S2 S2 402
A1-2 AD1 -2 -
AL 1
B duty room machine room B

ZF 2
405 Steel rope location lighting X4-4
X4-3 DX4 -3 - 402 404
DX4 -4
EB1
emergency light emergency light JL SBB1
X4-1 DX4 -1 400 + EB2

operating panel

A A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 interphone circuit page: 11
1 2 3 4
1 2 3 4

B200 B220
2/C2 2/C3
RB2

B202 B221
D
back door A3-6 A3-7 front door
D

D3-1 AD3 -6 D1-1


AD3 -7
L L
N D3-2 D1-2
N
2MJ(WUXI Flying VVVF) 1MJ(WUXI Flying VVVF)
U U
V DM D4-5 D2-5 DM V
W D4-4 D2-4 W
24V H1 H2 H3 C1 P1 C2 P2 24V A B 0V 24V A B 0V C1 P1 C2 P2 24V H1 H2 H3
N L N L
back door light curtain front door light curtain
NO C D1-9 D1-11 D1-10 D1-6 D1-8 D1-7
D3-6 D3-8 D7-7
D3-9 DX-11 D3-10 NO C
DX2 -1 DX2 -3 DX2 -2 2PG D4-6 1PG DX1 -9 DX1 -1 1 DX1 -1 0 DX1 -6 DX1 -8 DX1 -7
DX2 -4 DX2 -6 DX2 -5 D4-7 D2-6 D2-7
DX2 -7 DX2 -4 DX1 -1 2 DX1 -9
X2-1 X2-3 X2-2
X2-4 X2-6 X2-5 X1-9 X1-11 X1-10 X1-6 X1-8 X1-7
C X2-7 X2-4 X1-12 X1-9 C
1CM SG1 SK1 CM1 GM1 KM1
CM2 GM2 KM2 2CM SG2 SK2 AP2 2CM AP1 1CM

B200 B220
2/C2 2/C3
RB2

B202 B221
back door A3-6 A3-7 front door
D3-1 AD3 -7 D1-1
AD3 -6
L L
B N N B
2MJ(Panasonic VVVF)
D3-2 D1-2
1MJ(Panasonic VVVF)
U U
V DM D4-4 D4-5 D2-4 D2-5 DM V
W W
8 2 1 C3 B3 C2 B2 8 2 1 C2 B2 C3 B3
N L N L
back door light curtain front door light curtain
D3-6 D3-8 D3-7 D3-9 D3-11 D3-10
NO C NO C
D1-6 D1-8 D1-7 D1-10 D1-9 D1-11
DX2 -1 DX2 -3 DX2 -2 D4-6 D4-7 D2-6 DX1 -6 DX1 -8 DX1 -7 DX1 -1 0 DX1 -9 DX1 -1 1
DX2 -4 DX2 -6 DX2 -5 D2-7
DX2 -7 DX2 -4 DX1 -1 2 DX1 -9
X2-1 X2-3 X2-2 X2-4 X2-6 X2-5 X1-6 X1-8 X1-7 X1-10 X1-9 X1-11
X2-7 X2-4 X1-12 X1-9
CM2 GM2 KM2 CM1 GM1 KM1 SK1 1CM SG1
2CM SG2 SK2 AP2 2CM AP1 1CM

A A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 door machine wiring diagram(WUXI Flying,Panasonic) page: 12
1 2 3 4
1 2 3 4

B200 B220
2/C2 2/C3
RB2

B202 B221
D back door A3-6 A3-7 front door D

D3-1 AD3 -6 D1-1


AD3 -7
L L
P1 PE D3-2 D1-2 PE P1
N N
2MJ(Anliso VVVF) U
1MJ(Anliso VVVF)
U D4-4 D4-5 D2-4 D2-5
P2 V DM DM V P2
P3 P4 P6 W N L N L W P6 P4 P3
2 PE PE 7 6 5 4 3 2 1
3 1 7 6 5 4 24V A B 0V back door light curtain front door light curtain 24V A B 0V
NO C NO C
D3-8 D3-6 D7-7 D1-9 D1-11 D1-10 D1-8 D1-6 D1-7
D3-9 DX-11 D3-10 D4-6 D4-7 D2-6 D2-7
DX2 -3 DX2 -1 DX2 -2 2PG DX2 -7 DX2 -4 DX1 -1 2 DX1 -9 1PG DX1 -9 DX1 -1 1 DX1 -1 0 DX1 -8 DX1 -6 DX1 -7
DX2 -4 DX2 -6 DX2 -5
C X2-1 X2-2 X2-7 X2-4 X1-12 X1-9 C
X2-3
X2-4 X2-6 X2-5 X1-9 X1-11 X1-10 X1-8 X1-6 X1-7
AP2 2CM AP1 1CM
GM2 CM2 KM2 1CM SG1 SK1 GM1 CM1 KM1
2CM SG2 SK2

B200 B220
2/C2 2/C3
RB2

B202 B221
back door A3-6 A3-7 front door
D3-1 AD3 -7 D1-1
AD3 -6
L L
B N N B
2MJ(NBSL VVVF)
D3-2 D1-2
1MJ(NBSL VVVF)
U U
V DM D4-4 D4-5 D2-4 D2-5 DM V
W W
8 2 1 C3 B3 C2 B2 8 2 1 C2 B2 C3 B3
N L N L
back door light curtain front door light curtain
D3-6 D3-8 D3-7 D3-9 D3-11 D3-10
NO C NO C
D1-6 D1-8 D1-7 D1-10 D1-9 D1-11
DX2 -1 DX2 -3 DX2 -2 D4-6 D4-7 D2-6 DX1 -6 DX1 -8 DX1 -7 DX1 -1 0 DX1 -9 DX1 -1 1
DX2 -4 DX2 -6 DX2 -5 D2-7
DX2 -7 DX2 -4 DX1 -1 2 DX1 -9
X2-1 X2-3 X2-2 X2-4 X2-6 X2-5 X1-6 X1-8 X1-7 X1-10 X1-9 X1-11
X2-7 X2-4 X1-12 X1-9
CM2 GM2 KM2 2CM SG2 SK2 AP2 door machine cable number:
CM1 GM1 KM1 SK1 1CM SG1
2CM AP1 1CM
1# is CM1 2# is 1CM
3# is KM1 4# is SK1
A A
5# is GM1 6# isSG1

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 door machine wiring diagram(Anliso,NBSL) page: 12
1 2 3 4
1 2 3 4

MC1
L1 KM0 KM1
R U
L21 T1
D D
SP5000F KM1
L2
MC1 V
KM0 S (integrated MOTOR
INPUTAC
L22 T2 controller)
W KM1
MC1 KM0
L3 T
L23

TD1 L
C C

L1 UPS AC380V AC220V


WY1
N
L2
L3
AC110V
T1
T2
T3 AC36V
220V 440V
B
5.5~7.5KW 5.5~15KW SC-35 8MM output signal when 1 (short circuit PS: B

UPS action 2 phase seq uence)


11KW 18.5~22KW SC-50 14MM
supply voltage voltage input voltage output (1)short circuit relative jumpers
15KW 22MM
output signal when 3 (controller emergen cy
SC-60 220V J4 J18 according the power voltage.
UPS action 4 input signal)
380V J5 J17
input signal when 5
UPS power on 6 415V J6 J16
L1 0V
Transformer

220V 460V J7 J15


380V
L2 415V
460V
A A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 UPS control circuit page: 13
1 2 3 4
1 2 3 4

D D

CAN3L

CAN3H

CAN3L

CAN3H
CAN3L

CAN3H
C C

GND TXL3 TXH3 GND TXL3 TXH3 GND TXL3 TXH3

JC3 JC3 JC3

SP6000-F3-01 SP6000-F3-02 SP6000-F3-08

B
elevator 1 elevator 2 elevator 8 B

Note: 1.Short-circuit JC3 on main board ofterminal control cabinet and do not short-circuit JC3 on other main board in condition of group control.
2.Connect the power supply 24V- pins ofall control cabinets together in condition of group control.

A A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 parallel,group control wiring diagram page: 14
1 2 3 4
1 2 3 4

SP6000-F3 Advanced door-open board


D V+ D
J1.2 24V+ JP1.11

11 K0 12 21 K1 22
V-
J1.4 24 V- JP1.4 K4
21 K10 22 21 22 A1
K2 A2

64 K2 61
D5
11
K1 12

C1
K2
41 42
SQU
PS JP1.5 K0 A1 A1

41 42
K0
up leveling D2
K2
C Advanced door-open output signal SQD 31 32
C
COM6 PX JP1.3
J17 .1 K1 A1
K1 A1
32
down leveling 31
D3

Y8 Y10
J17 .2 JP1.1 A1 A1
K4
K0 D4
X21 K2 K4 30 31

J4.7 JP1.6 21 22 33 34
K1
41 44
pre-opening detection feedbacksignal
JP1.7

K0 K1
JP1.8 54 51 64 61
B B

X22
J5.1 JP1.9

K0
1KTM1 KTM(n) K2 K4
61 64

T170 JP1.2 11 12 44 43
K1
1T01 封门锁 51 54

KJM
A130 JP1.10
封门锁

A A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 Advanced door-open circuit,re-leveling circuit page: 15
1 2 3 4
1 2 3 4

U1 V1 W 1 PE 4 lines
M motor
terminals F0 2 Cable
F0 4 PG enco der
RS48 5
24 V- PTC 2 lines
L1 1 L12 L13 N PE 5 lines C1 F0 8 PTC temp erature sensor of motor
external power grid terminals(power line)
terminals F0 3 A63 A68 2 lines DZZ brake coil
D
UPS
control cabinet(elevator 1) F0 9 24 V- BZ 2 lines BZK brake po sition limit
control cabinet D

F0 6 A118 A12 0 PE 3 lines ov ersp eed gov ern or safety


(elevator 2)
XSK circu it switch
C1 2 lines
5 lines 50 1 502 503 504 PE D03 terminals F0 7 A124 A12 5 SSL han dwheel switch
F1 2 3 lines
3 lines 50 1 504 PE terminals B1 B3 B2 A1~A3 terminals ZQ ZQ1 ZQ2 ov ersp eed gov ern or
reset coil
D032 4 lines 40 2 E1 E2 401 F10 D01 D02 D05 D04 D07 X01
interp hon e
3 8 5 24 V- CAN3H CAN3 L
top flo or 3lines S1 (n -1 ) S170 PE lines lines lines
nKMT nKMT1 3 lines
hall d oor lo ck X07 20 1 205 PE FS1
car fan
5 lines X08 20 1 204 2 lines DM1
24 V+ 2 4V- CAN1L CAN1H PE D05n car light
hall call b ox of floo r N
X09 A120 A12 1 2 lines XSK safety p in cer

Traveling cable
D8
up per final limit switch 8KW 3 lines A117 A118 PE D021 X10 A121 A12 2 2 lines XSK security windo w
X12 24 V+ 2 4V- BZ 3 lines DZ L arrival chime
C
up per limit switch 6KW 3lines S1 W 24 V- PE D041
X13 24 V+ 2 4V- MZ CZ QZ 5 lines
C
D6 weig hing dev ice
force d eceleratio n
(speed:1.0m/s)
2KW 3lines S3 W 24 V- PE D042 Car top inspection box X14 A130 T101 PE 3lines KMJ fro nt d oor lo ck
force d eceleratio n 4KW 3 lines S4W 24V- PE D043 D2 X15
B 202 B22 1 PE 3 lines lightcurtain
shaft light cable

device
(speed:2.5m/s) front door light curt ain power supply

shaft communica tion c able


X16 1AP C OM1 2 lines KAP fro nt d oor ligh t curtain sign al

shaft information cable


AD1~AD4
X17 T1 01 T1 02 PE 3lines 1KMJ back d oor lo ck
X18 B202 B22 1 PE 3lines lightcurtain
device back door light curt ain power supply
D4
X19 1AP C OM1 2 lines 1KAPback d oor ligh t curtain sign al
bo ttom floo r 3 lines T101 H101 PE X02 B202 B 22 1 PE 3 lines
1KMT 1KMT1
hall d oor lo ck D1 X03 KM1 KM1 CM1 COM1 SK1 SG 1 PE 7 lines fro nt d oor mach in e
2 lin es X04 B202 B 22 1 PE 3 lines
fire figh ting b ox FR V- 5 lines 24 V+ 24V- CAN1L CAN1H PE D3 X05 KM2 GM2 CM2 back d oor mach in e
7 lines
COM2 S K2 S G2 P E
hall call b ox of bottom floor X06 E1 E2 2 lines
B car top interpho ne B
D7
X23 PS、PZ 、PX 、24 V+、24 V- 5 lines SQU up
force d eceleratio n 3lines S6W 2 4V- PE D046 DX1 ~DX4 leveling do the wiring
3KW SQP
(speed:2.5m/s) leveling when need
force d eceleratio n 1KW 3lines S5W 2 4V- PE D047 X25 X26 X27 X28 X29
(speed:1.0m/s) SQD down advanced
3 19 6 4 10 leveling door-opening
3lines S2W 2 4V- PE D048 lines lines lines lines lines
lower limit switch 5KW function
secon d emergen cy
A112 A11 3 PE 3 lines stop
A116 A1 17 PE A111 A112 PE 3 lines X1~X4
3 lines 50 2 503 504 lower fin al limit switch 7KW 3 lines DSK rope-brok in g operating panel
switch
D031
SPDT switch cou nterweight 3lines A115 A1 16 PE A114 A115 PE 3 lines
DXK2 DSK1 car b uffer switch
bu ffer
3 lines 501 504 PE
Pit phone
A BK A
Pit inspection b ox

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 system diagram page: 16
1 2 3 4
1 2 3 4

NO. code name quantity place remark NO. component code component name quantity place remark
1 1AP、2AP front,back door light curtain switch each 1 car roof 49 KAC security window 1 car roof
2 1DJD~nDJ shaft light n shaft 50 KAQ safety gear 1 car roof
3 1GM、2GM front,back door-close arrival switch each 1 power operated door 51 KCZ over load switch 1 car platform
4 1KJM back car door lock switch 1 power operat ed door 52 KDH counterweight buffer 1 pit
D 5 1KM、2KM front,back door-open arrival switch each 1 power operat ed door 53 KDS overspeed governor rope-broking switch 1 pit D
6 1KTM1~1KTMn back hall door lock switch n hall door device 54 KDT emergency stop button on car top 1 car top inspection box
7 1KW upper limit switch 1 shaft 55 KDT1、KDT2 emergency stop button in pit each 1 pit
8 1MJ、2MJ front,back door machine controllers each 1 power operat ed door 56 KFS fan switch 1 operating panel
9 2KW lower limit switch 1 shaft 57 KFT emergency stop button in m achi ne room 1 control cabinet
10 3KW up force deceleration switch 1 shaft 1. 0m/s<V≤2.0m/s 58 KJH car buffer 1 pit
11 4KW up force deceleration switch 1 shaft 2. 0m/s<V≤2.5m/s 59 KJM front car door lock 1 power operated door
12 5KW down force deceleration switch 1 shaft 1. 0m/s<V≤2.0m/s 60 KJX rope gripper 1 machine room
13 6KW down force deceleration switch 1 shaft 2. 0m/s<V≤2.5m/s 61 KM0 power input contactor 1 control cabinet
14 ADS inspection up button(on car top) 1 car top inspection box 62 KM1 main output contactor 1 control cabinet
15 ADT inspection switch(on car top) 1 car top inspection box 63 KMZ full load switch 1 car platform
16 ADX inspection down button(on car top) 1 car top inspection box 64 KQZ under load switch 1 car platform
17 AFT inspection switch(in machine room) 1 control cabinet 65 KRP handwheel switch 1 machine room
18 AL alarm bell button 1 operating panel 66 KSA safety contactor 1 control cabinet
C 19 AYS inspection up button(in car) 1 operating panel 67 KSJ upper final limit switch 1 shaft C
20 AYT inspection switch(in car) 1 operating panel 68 KSX lower final limit switch 1 shaft
21 AYX inspection down button(in car) 1 operating panel 69 KTM~KTMn front hall door interlock n power operated door
22 BR brake resistance 1 control cabinet 70 KXT emergency stop button in car 1 operating panel
23 BY transformer 1 control cabinet 71 KXS overspeed governor switch 1 machine room
24 72 KXX phase sequence 1 control cabinet
25 BZ1 brake contactor each 1 control cabinet 73 KZD brake assistance contactor 1 control cabinet
26 C1 electrolytic capacitor 1 control cabinet 74 L1S~L(n-1)S hall up command light n-1 hall call box
27 DB1 、DB2 brake position limit switch each 1 motor 75 L2X~LnX hall down command light n-1 hall call box
28 DIR driver switch 1 operating panel 76 LA01~LA(n) floor command light n operating panel
29 DJR1 、DJR2 220V socket on car top and in pit each 1 car top inspection box 77 LCL1、LCL2 front,back door-close command light each 1 operating panel
30 78 LOOK elevator lock switch 1 base floor
31 DJR5 、DJR6 ~220V,socket each 1 machine room 79 LOP1、LOP2 front,back door-open command light each 1 operating panel
32 DM door machine motor 1 power operat ed door 80 JN electric relay 1 car top inspection box
33 DM1 car light 1 car roof 81 JFS inspection down button(i n machi ne room) 1 control cabinet
B B
34 DM2、DM3 car top light,pit light each 1 car top inspection box 82 JFX i nspecti on up button(in machine room) 1 control cabinet
35 DM4 control cabinet light 1 control cabinet 83
36 DZ1、DZ2 rectifier bridge each 1 control cabinet 84
37 DZL arrival chime 1 operating panel 85
38 DZZ brake coil 1 motor 86
39 D1、D3、D4 diode each 1 control cabinet 87
40 D2 diode 1 control cabinet IN5048 88
41 EMD emergency power 1 car roof 89
42 ERA earthquake detection instrument 1 machine room 90
43 F1~F8 circuit breaker 8 control cabinet 91
44 FIRE fire switch 1 fire base floor 92
45 FL buzzer 1 operating panel 93
46 FW overspeed governor reset coil 1 overspeed governor 94
47 FS1 car fan 2 car roof 95
A 48 HZ power switch 1 machine room 96 A

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 component code table 1 page: 17
1 2 3 4
1 2 3 4

NO. component code component name quantity place remark NO. component code component name quantity place remark
1 M motor 1 machine room
2 MS1 front door lock contactor 1 control cabinet
3 MS2 back door lock contactor 1 control cabinet
4 PG encoder 1 motor
D D
5 PTC motor overheat prevention switch 1 motor
6 RB1 power supply switch 1 control cabinet
7 RB2 circuit breaker of door machine power 1 control cabinet
8 RB3 circuit breaker of 220V power 1 machine room
9 RZ1 current limited resistance 1 control cabinet
10 S1S~S(n-1)S hall up command button n-1 hall call box
11 S2X~SnX hall down command button n-1 hall call box
12 SA01~SAn floor command button n operating panel
13 SBB1 interphone button 1 operating panel
14 SBS、SBX、GM3 light switch(in shaft) each 1 shaft
15 SCL1、SCL2 close command button each 1 operating panel
16 SOP1、SOP2 open command button each 1 operating panel
17 SQD down leveling photoelectric switch 1 car roof advanced door-open

18 SQP leveling photoelectric switch 1 car roof


C C
19 SQU up leveling photoelectric switch 1 car roof advanced door-open
20 UPS emergency power supply device 1 machine room
21 VIP VIP switch 1 operating panel
22 WY1 switch power supply 1 control cabinet
23 ZD inspection switch(on car top) 1 inspection box(on car top)
24 ZF inspection switch(in machine room) 1 control cabinet
25 ZM light switch(in car) 1 operating panel
26 ZM2T light switch(on car top) 1 inspection box(on car top)
27 ZM3T light switch(in pit) 1 pit
28 ZM4 light switch(in control cabinet) 1 control cabinet
29 ZT overspeed governor action switch 1 control cabinet
30 ZY inspection switch(on car top) 1 inspection box(on car top)

31 ZJ emergency electric operation switch 1 control cabinet


32 SP6000F-CB car board 1 operating panel
B 33 SP6000F-CEB car extension board 1/16F operating panel mor e than 16 floors B
34 SP6000F-HAX hall call board n+1 operat panel,hallcall box CANBUS
35 SP6000F main control board 1 control cabinet
36 SP6000F-HSX hall call board n+1 RS485
37
38
39
40
41
42
43
44
45
46
A
47 A
48

Design Audit Technics SP6000-F3 elevator control system schematic diagram Version:V1.00
Check Approval Date 2010.04.12 component code table2 page: 18