You are on page 1of 38

INTEGRATED ELEVATOR

SOLUTION
NICE1000+ & NICE3000+

Version : 1.0
By : Subra
SOLUTION FOR HIGH RISE SOLUTION FOR LOW/MEDIUM RISE
AND AND
HIGH SPEED ELEVATOR LOW / MEDIUM SPEED ELEVATOR

NICE3000+ NICE1000+
Serial Communication Parallel Communication
Speed up to 4mps Speed up to 1.5mps
Max 40 floors (Standard) Max 16 floors (Extn)
NICE1000+ / NICE3000+
SUITABLE FOR MR & MRL PANELS

MR Panel MRL Panel


NICE3000+ INTEGRATED ELEVATOR
SOLUTION
ENVIRONMENTAL FACTORS

FACTOR LIMITATION
Altitude Below 1000 m (de-rated 1% for each 100 m higher)
Ambient temperature –10°C to 40°C (de-rated if the ambient temperature is
above 40°C, maximum temperature: 50°C)
Humidity Max relative humidity 95%, non-condensing
Vibration Max vibration 5.9 m/s2 (0.6 g)-(10–55 Hz, 0.35 mm)
Storage temperature -20°C to 60°C
IP level IP20 (Ingress of solid object diameter 12.5 mm is
protected & no protection against liquid object)
Pollution degree PD2 (Only nonconductive pollution occurs. Occasionally, temporary
conductivity caused by condensation is to be expected)
Power distribution TN, TT (TN-direct connection to earth of one point, usually the
system neutral, in a.c. systems & direct electrical Connection of the exposed-
conductive- parts to the earthed point of the power system)
MAJOR FEATURES OF NICE3000+
IMPORTANT FEATURES
NICE3000+
Dedicated
110Vac/dc Safety
Circuit Input
Indian Fireman Programmable I/O’s

Inside Car Static Tuning for


commissioning for Geared/Gearless
floor leveling Machine

Auto Pre-torque Wide Input


compensation* Operating Voltage

Duplex/Group up
Individual Floor
to 8 Elevator cars
level adjustment
UPS/ARD mode
Least Current
direction
STANDARD FEATURES
NICE3000+
In-Built Real Time
Clock Features
VIP Floor
N-Curve
Direct to Floor V

Two side Door


Car Call
Cancellation

Struck Call
Differently abled Identification
Function
3 Level Password Real Time clock
based Event logs
SPECIAL FEATURES
 Short floor distance running profile up to 300mm
 Peak Service in group function
 Guard Floor Service at night
 Time based Service Floors Function in Group
 Time based Down collective/selective function in Group
 Main, Sub and Differently abled Car Operating Panel Function
 Time based Elevator Lock Function
 Selectable Service Floors function
 Anti Nuisance Function based on Load cell or Door sensor
 Pre-opening and Re-leveling Function
 Door Nudging Function
 Earth Quake Protection Function
 Motor thermal Protection Function etc.,
EASE OF FIELD COMMISSIONING

Quick Start-up Commissioning


Need to adjust less than 10 parameters to run the lift in normal
(With Default setting)
On-Board Diagnosis LED’s for Input / Output Function
On-Board LED Display and Mini Key Button for Easy
commissioning and Diagnosis
PC Software for NICE3000+ Functional analysis & Diagnosis
No need of Providing floor to floor slowdown switches
Reduced Field wiring using Serial Communication
Multiple Error code function for easy and quick diagnosis
ACCESSORY INFORMATION—CTB ( CAR TOP BOARD )
Two Door Functions Auto Fan

C3
DM
D2
D1

C2
C1
CM
C3M

B3
B1
B2
BM

AM
B
A
Φ4.9
CN4 CN5
D2 D1 C3 C2 C1 B3 B2 B1 A1
CN10
J2 J9
ON OFF

CAN
Main COP
125
115

CN7
RESET
MCTC-CTB

Sub COP CN8

X1 X2 X3 X4 X5 X6 X7 X8
CN2 CN1 CN6 CN3
CAN+
CAN-

MOD+
MOD-
24V

P24
24V

P24
24V

X1
X2
X3

X5
X7
X8
X6
X4
COM
COM

Ai
M

152
MOD bus 162 Door Feedback
Digital Load cell
CAN bus Analog
Load cell
ACCESSORY—CCB ( CAR CALL BOARD )

(CTB)
CN7 CN8
1 to 16 Car Calls

Door Open Non Stop


CN2 CN2 Door Close Door Delay
(CCB) (CCB)
Floor1 Floor
Attendant Independent
~16 CN1 1~16 CN1
Direction Change Fireman
Main Sub All plug terminal wiring chart shown as follows:
control control
box box

CN2 CN2
(CCB) (CCB)
Level Level
17~31 17~31
HALL CALL FUNCTION & CAR POSTION DISPLAY
MCTC-HCB-H MCTC-HCB-F MCTC-HCB-B MCTC-HCB-P

MCTC-HCB-D2 MCTC-HCB-T1 MCTC-HCB-T2 (7INCH)


MCTC-HCB-T3(9.7INCH)
FUNCTION CODE GROUP

CODE DESCRIPTION CODE DESCRIPTION


F0 Basic parameters F9 Time parameters

F1 Motor parameters FA Keypad setting parameters

F2 Vector control parameters Fb Door function parameters

F3 Running control parameters FC Protection function parameters


F4 Floor parameters Fd Communication parameters
F5 Terminal parameters FE Elevator function parameters
F6 Basic elevator parameters FF Factory parameters
F7 Test Function parameters FP User parameters
F8 Enhanced function parameters Fr Levelling adjustment
parameters
Group Control Board (GCB)
 It requires to use group control board (MCTC-GCB-A), under standard occasion,
it can realize 4sets group control. Use non-standard configuration can realize 8
sets group control. For 4 sets group control, the wiring is as followed
24V电源输入

COM 24V
24V
CN1 CN3 CN6
CN2

D5
D3
D37 D2
D40
D41
D42
D43
D44
MCTC-GCB-A
D45
D46
D47

CN7 CN9 CN8 CN10


CAN1 CAN1 CO CAN2 CAN2 CO CAN3 CAN3 CO CAN4 CAN4 CO
24V + - 24V + - 24V + - 24V + -
M M M M

CO CAN CAN CO CO CO
24V

CAN

CAN 24V CAN CAN CAN CAN


24V 24V

+ + - M + - + -
M M M
MCB1 MCB2 MCB3 MCB4

CAN CAN CO CAN CAN CO CAN CAN CO CAN CAN CO


24V + - 24V + -
24V + -
24V + -
M M M M
CTB1 CTB2 CTB3 CTB4
PARALLEL CONNECTION APPROACH
PARALLEL CONNECTION FOR DIFFERENT LEVEL OF TWO LIFTS

5 Level 4 Physical level 5

Level 3 4 4 Level 3 Physical level 4


Leveling board:

Level 2 3 Level 2 Physical level 3


(not in service) Hall call and address
2 2 2
Level 1 Level 1 Physical level 2

Level B1 1 Physical level 1

Lift #1 Lift #2
NICE1000+ INTEGRATED ELEVATOR
SOLUTION
ENVIRONMENTAL FACTOR

FACTOR LIMITATION
Altitude Below 1000 m (de-rated 1% for each 100 m higher)
Ambient temperature –10°C to 40°C (de-rated if the ambient temperature is
above 40°C, maximum temperature: 50°C)
Humidity Max relative humidity 95%, non-condensing
Vibration Max vibration 5.9 m/s2 (0.6 g)-(10–55 Hz, 0.35 mm)
Storage temperature -20°C to 60°C
IP level IP20 (Ingress of solid object diameter 12.5 mm is
protected & no protection against liquid object)
Pollution degree PD2 (Only nonconductive pollution occurs. Occasionally, temporary
conductivity caused by condensation is to be expected)
Power distribution TN, TT (TN-direct connection to earth of one point, usually the
system neutral, in a.c. systems & direct electrical Connection of the exposed-
conductive- parts to the earthed point of the power system)
MAJOR FEATURES OF NICE1000+
IMPORTANT FEATURES
NICE3000+
Dedicated
110Vac/dc Safety
Circuit Input
Indian Fireman Programmable I/O’s

Inside Car Static Tuning for


commissioning for Geared/Gearless
floor leveling Machine

Auto Pre-torque Wide Input


compensation* Operating Voltage

Duplex Function Individual Floor


level adjustment
UPS/ARD mode
Least Current
direction
STANDARD FEATURES
NICE1000+
Direct to Floor
Two side Door
N-Curve
V

Event logs
Struck Call
Identification

3 Level Password Indian Fireman


STANDARD FEATURES
 27 Programmable Input terminals and 27
Programmable relay output terminals
 50 Programmable Input terminals for call functions
 Supports double digit 7 segment, Binary code and
Grey code displays
 Test function with isolated Landing calls, Overload
and terminal floor switch functions, helpful to do
mechanical, electrical fine-tuning and ride
observation
 Selectable Service Floors function
 Anti Nuisance Function based on Load cell or Door
sensor
 Supports Auto Door, Manual Door and Semi-Auto
Door
 Door Nudging Function
 Earth Quake Protection Function
 Motor thermal Protection Function etc.,
EASE OF FIELD COMMISSIONING

Quick Start-up Commissioning

Need to adjust less than 10 parameters to run the lift in


normal (With Default setting)

On-Board Diagnosis LED’s for Input / Output Function

PC Software for NICE1000+ Functional analysis & Diagnosis

No need of Providing floor to floor slowdown switches

One to one Field wiring using Parallel Communication

Multiple Error code function for easy and quick diagnosis


FUNCTION CODE GROUP

CODE DESCRIPTION CODE DESCRIPTION


F0 Basic parameters F9 Time parameters

F1 Motor parameters FA Keypad setting parameters

F2 Vector control parameters Fb Door function parameters

F3 Running control parameters FC Protection function parameters


F4 Floor parameters Fd Communication parameters
F5 Input terminal parameters FE Elevator function parameters
F6 Basic elevator parameters FF Factory parameters
F7 Output terminal parameters FP User parameters
F8 Enhanced function parameters Fr Levelling adjustment
parameters
NICE3000+ SITE INSTALLATION
PHOTO
DUPLEX CONTORLLER
CAR ELEVATOR & GOOD ELEVATOR
2.5MPS ELEVATOR WITH DOUBLE WRAP MACHINE
SITE PMT READING OF NICE3000
GEARLESS MACHINE FOR REFERENCE
LIFT SPEED : 2.5MPS No Of Floors : 13
LIFT SPEED : 2.5MPS No Of Floors : 13
MONARCH INTEGRATED ELEVATOR SOLUTION

wow !… Delightful Ride


THANK YOU

You might also like