You are on page 1of 40

Product catalog

Variable Speed

Drives

AK06

www.triolcorp.com
contents

VARIABLE SPEED DRIVE (VSD) AK06 SERIES


3

DISTINCTIVE BENEFITS
4

OPTIONS AVAILABLE
11

VSD AK06: short line descriptions


12

FILED APPLICATIONS FOR VSD AK06


13

VSD AK06 UD (UNIVERSAL DRIVE)


14

VSD AK06 CP (CLEAN POWER)


19

VSD AK06 PS (PHASE SHIFTING)


24

VSD AK06 RD (RIGHT DRIVE)


29

VSD AK06 LH (LOW HARMONIC)


34

VSD AK06 FC (FLEXIBLE CABINET) 39


VARIABLE SPEED DRIVE

(VSD) AK06 SERIES

The Variable Speed Drive (VSD) AK06 Series is designed to control and protect electric

submersible and surface-type pumps with induction or permanent magnet motors. Triol's

VSD AK06 solution combines advanced technology with outstanding operational and

performance qualities and excellent reliability.

Triol's VSD AK06 Series is available is six distinct

lines, each one created for a specific use case and a

6
PRODUCT
defined segment of the global oil production industry.

The lines differ based on the cabinet enclosure type

and the power requirements at the VSD input.


lines

The VSD AK06 Series is the optimal solution for a

diverse range of operational tasks and is designed

to boost operational efficiency and save time for

service personnel.


The advanced programming of the VSD AK06


artificial
Series' operational system provides immediate value

LIFT and return-on-investment for oil production

companies. VSD AK06 Series products can be

applied to virtually any electric submersible pump

(ESP) technology task, to provide maximum

operational benefits.

VSD AK06 Series products are suitable for operation in

the following challenging conditions/locations:

4
Arctic

Tropical

climatic Desert

conditions
Maritime (including offshore platforms)

3
DISTINCTIVE BENEFITS
Maximizes Productivity
Voltage Drop Protection

Compensation mode routes kinetic energy from the


motor when switching to the generator mode of
operation (for induction motors), via an additional
power ride-through module.

“Catch on the Fly” Feature

Rapid turbine rotation supports flying start



(for induction motors).

Gas Lock Solution

Eliminates fluid displacement and upstream flow


disruption by intelligently adjusting the output
frequency. Advanced pump unit algorithms eliminate
gas-locking, resolve well intake decompression issues,
and boost pump efficiency.

Simplified Conditioning
Automatic Well Commissioning

Engage automatic mode for well commissioning: use controls to incrementally


increase motor rotation speed to reach pre-determined depth, automatic mode
maintains ideal operating parameters.

Pre-Emergency Status Detection

Alarm signals pre-emergency conditions, before an adverse event happens; VSD


auto restarts (available soon).

4
Soft and Hard Start Modes

Jog Mode. Startup is initiated with a sequence of low frequency overvoltage


pulses applied to the motor, until reaching nominal.

Shimming Mode. Startup is initiated to develop maximum motor torque at low


frequency. In this startup mode, when the pre-determined motor slip value is
maintained for two seconds, low frequency voltage is applied until ESM is twice
nominal ESM current at this frequency.
Hard Start Mode. Startup is initiated
by increasing output frequency and
voltage at a given rate, according

to the V/Hz configuration. Upon
reaching split frequency, the output
voltage rises by a given amount at

a given rate, until reaching nominal.

Swing Mode. Startup is initiated by


alternating direction of rotation,
with gradually increasing frequency
until reaching nominal.

Synchronization Mode. On startup, output frequency increases according to setting,


until reaching the synchronization frequency. Output frequency is maintained during
synchronization, then increases according to specified rate until reaching nominal.

User friendly interface

5
Controls and settings are simple to understand and designed to reduce
complexity and potential errors; highly skilled operators are not required.

Main display allows access to all controls, for fast operation and ultimate
convenience.

Adjustable display: partial- or full-screen modes.

Requires fewer inputs, for faster operation that improves efficiency and reduces
project time.

ESP Run Life Extensions


Run Time Each line and variation features a built-in

excellent (<3%) sine filter.

Current optimization mode reduces step-up


transformer heating in the submersible motor,
which prolongs service life.

Protects against torque fluctuations.

Backspin control protects the motor against high


fluid pressure.

ESP run life extension

Submersible elements are protected by built-in


insulation monitoring system.

Sophisticated grounding protects the cable


system.

Value Benefits
6 lines with more than 100 variations provide versatile solutions suitable

for any well.

Universal solution for induction and permanent magnet motors.

6
Minimal footprint reduces investments in platforms, groundwork and

infrastructure.

Wide range of protocols compatible with almost any digital network.

Junction box with terminal lugs is suitable for any type of cable connection,

without need for special tools.

Sensor section does not require a separate cabinet.

Cost Savings

Voltage Optimization Mode

Automatically calculates and adjusts output voltage, taking into

account all circuit elements, thus reducing network power

consumption.

Automatic Start Modes

Automated start programs do not require supervision

by operating personnel: start, emergency stop, and

restart functions are all automated.

Triol Vector Control Mode

Advanced, unique design allows maximum efficiency of the submersible PMM.

Operating Modes

Timer modes allow operation according to pre-set schedules, including automated

start and stop functions.

Smooth motor acceleration and deceleration at all rates.

On/off motor settings.

Motor reverse setting.

Start modes include:

Jog mode start;

Swing mode start (can be used to uncouple the submersible unit);

Synchronization mode start;

Shimming mode start, to ensure maximum motor torque at low speed.

7
Field weakening mode allows operation

when rotational speed is higher than

nominal (only for induction motors).

Operation modes include:

“Manual” (without automatic motor


reactivation after fail safe trigger);

“Automatic” (with automatic reactivation);

“Automatic” (according to automated timer


program);

Automated output frequency adjustments


occur according to a pre-set timer program.

Automatic start with an adjustable time delay.

Current optimization mode activates automatically when the pre-set speed


is reached.

Supports the Following DMS

Triol Novomet ViewPoint RMSpumptools

Borets Phoenix PICv2 Oxford R5 Scout

Izhevsk WoodGroup SPT-2 Solvapli

Phoenix Phoenix/Uniconn ACE Downhole Transfer+

Centrilift Zenith WellLift Oxford R4 10K

Custom support for other sensor and DMS products (available soon)

Motor Insulation Control


Continuous monitoring of cable-motor system insulation resistance, with motor
disconnection fail safe when insulation is disrupted.

Ability to operate with reduced cable-motor system insulation resistance, with


rapid disconnection at overload.

8
Equipment Protection
Indicators display VSD AK06 operational status: Operation, Standby, Shutdown,
Backspin.

Configure on-site to a variety of performance parameters, including: Protection


Against Overload and Underload, Electric Drive Protection Against Dangerous Main
Voltage/DC Values, Variable Current Protection, Long-Term Low-Frequency
Operation Protection, Overheating Protection, Beyond Limits Downhole Operation
Protection.

Automatic motor brake for motor protection during start, emergency stop,

and restart.

Continuous monitoring of three phases of power supply and voltage availability;

if one of the phases is missing, motor will disconnect or disable startup.

Remote control

Manual motor speed control via UMKA-07 controller and remote control panel.

Ability to control the motor remotely, and view/change protection settings of the
downhole measuring system via RS485 and/or Ethernet interface.

Ability to control the motor via submersible device (sensor).

Automatically maintain performance settings and values (pressure, current, etc.).

9
Fail-Safe Safety Features

Voltage underload Electric drive low


(protects against output
supply disruption)

Reduced insulation Voltage overload


resistance in
cable-motor system

Electric drive power


protection is motor
Excess current
triggered
switch

off
Main power supply Power module
voltage deviation overheating

Downhole measuring Excess pipeline


system parameters pressure
exceeded

Power compartment
cabinet door open

10
Options available
Increased overvoltage protection:

-1ns full-time surge suppression;

-Transient voltage surge suppression.

Additional power supply for external


equipment:

- Socet 110/220V, 10A;

- User output 110V, 500 VA;

- User output 110V, 1500 VA;

- UPS 500 VA;

- UPS 1500 VA.

Electricity monitoring system

Additional digital interfaces for


communication with remote control
systems

External power supply, for continuous operation when normal power supply
is unavailable or interrupted

Expansion modules for connecting peripheral devices:

- ADAM-4017+ (8 analog inputs 4…20 mA, 0…10 V, 0…5 mA);

- ADAM-4051 (16 digital inputs 24 VDC);

- ADAM-4024 (4 analog output 4…20 mA, 0…10 V, 0…5 mA);

- ADAM-4055-ВЕ (8 digital inputs 24 VDC и 8 digital inputs);

- ADAM-4069 (8 digital outputs 220В, 5А).

Full list of options available at www.triolcorp.us

11
VSD AK06: short line

descriptions
Line Description Definition

UD NEMA4, NEMA4X, -20°С …+60°С (-4°F...+140°F);


6/12/18/24 pulse Universal Drive

CP NEMA4, NEMA4X, -20°С …+60°С (-4°F...+140°F); 



PHF (passive harmonic filter), 6/12 pulse Clean Power
NEMA4, NEMA4X, -20°С …+60°С (-4°F...+140°F); 

PS PSA (phase shifting autotransformer) Phase Shifting
NEMA3R, -20°С …+50°С (-4°F...+122°F);
RD 6/12 pulse Right Drive

LH NEMA3R, -20°С …+50°С (-4°F...+122°F); PHF


(passive harmonic filter) Low Harmonic
NEMA4 Cabinet -20°С …+40°С (-4°F...+104°F), with
FC sine wave filter (standard) and passive harmonic
filter (on request)

12
FILED APPLICATIONS

FOR VSD AK06


Priority date 08/28/2017
Priority date 05/23/2018

System and method for forced air cooling of Universal microprocessor controller
an electrical device

Priority date 06/22/2018

Priority date 09/20/2017


Variable Speed Drive cabinet with an active
Cooling method for powered semiconductor filter-compensating device

devices Cooling device for a Variable Speed Drive


cabinet

Priority date 11/20/2017

Priority date 06/23/2018

Method of protection against electric shock


Modular high-voltage device

Priority date 05/20/2018

Priority date 08/08/2018

Variable Speed Drive device with a passive


filter of split design Quick-detachable power cells

Priority date 05/22/2018


Priority date 12/11/2018

Active power filter


Variable frequency drive
Plate heat exchanger for an electrical device

Dust and moisture removal device for


electrical equipment

13
VSD AK06 UD
(UNIVERSAL DRIVE)
The Variable Speed Drive AK06 UD (Universal Drive) line is a premium solution for
complex tasks, with the maximum focus on minimizing product maintenance time
during implementation, operation and repair. Advanced specialized control algorithms
and excellent modular design ensure maximum safety, reliability and efficiency.

VSD AK06 drives are designed to control submersible and surface installations of
electric submersible and positive displacement pumps in harsh conditions. Triol's
specialized authoring control algorithms provide efficient control of installations, for
both induction and permanent magnet motors. The rated output current of VSDs
varies from 100 A to 3000 A, the supply voltage is 380/480 V, 50/60 Hz (versions with
supply voltage up to 690 V are available).

Variable Speed Drive AK06 UD is UL certified.

Operating temperature range

-20 °С ... + 60 °С (-4°F...+140°F)

Enclosure -
NEMA4, NEMA4X

Controller screen
"6 or 7"
Onshore and
offshore application
Induction and

PM motors control

Output voltage and


current sinusoidal
6 12 pulses in same size
18 24

CE, UL certified
14
Overall dimensions
Rated current Rated power,Full output Width, Depth,
Height,
Mass
kVA
(output current),
power, (with sine Cabinet mm mm mm (max),
Amps
kVA wave filter) (inch)
(inch)
(inch)
kg (lb)
100 83 75
160 133 120 №1 1350
1210
1955
540

(53.15)
(47.64)
(76.97)
(1190)

250 208 187

300 249 224


360 299 269 1350
1110
2000
600

№2 (53.15)
(43.7)
(78.74)
(1323)

400 333 299


420 349 314
515 428 385
590 491 441 1670
1210
2000
830

№3 (65.75)
(47.64)
(78.74)
(1830)

630 524 471


675 561 505
800 665 599 №4 1690
1210
2000
975

(66.54)
(47.64)
(78.74)
(2150)

900 748 673


1000 831 748
1200 998 898 2130

№5 (83.86)
1250
2180
1650

(49.21) (85.83)
(3638)

1400 1164 1048

1600 1330 1197


Up to 3000 Amps VSD’s available on tandem drives
*Overall dimensions and mass may have slight deviations

**Power for 480V supply voltage; for 380V supply voltage, reduce power 21%

15
Input parameters

Parameter Value

3x380 ± 15% / 3x480 (-15% ... + 10%)

Power supply, V -50% continuously with reduced output power;

-65% up to 500 ms (with a decrease of output power)

Input frequency, Hz 50/60 (-5% ... + 5%)

Output parameters

Parameter Value

Rated output current, A 100 - 3000

Overcurrent characteristics 120% of rated value for 60 sec

1.5 - 80 Hz, in induction motor control mode

Output frequency 1.5 - 200 Hz, in permanent magnet motor control mode

Up to 600 Hz, in high-speed PMM control mode

Maintain parameters

Parameter Value

Light alarm “Work”, “Waiting”, “Stop”, “Backspin”

Operator control voltage Option:

10 V DC, +/- 2% current not more than 30 mA,

24 V, 300 mA

110/220 V, 10A for connecting of third-party consumers

Insulation G alvanic isolation b etween power and user circuits

Insulation resistance > 5 MOhm

Overcurrent protection;

Protection type Power switched temperature (I G T


B );

Max. and min. voltage in the DC link.

E nclosure material Car b on steel, stainless steel

Relative humidity 100 %

Air-to-air heat exchanger for power compartment

cooling; forced air for cooling elements of the power


Cooling type

circuit

16
Inputs/Outputs

Parameter Value

Number of AI 2 by default, optional extension +8

Programmable 4..20 mA, 0..5 mA, 0..10 V (frequency


AI type
reference / multifunction analog input)

Number of DIN 2 by default, optional extension +4 or more

Option, 4 or more programmable 4..20 mA, 0..5 mA,


Number of AO
0..10 V

Number of Relay Outputs Option, 8

Communication

Parameter Value

Communication port Modbus

-2-wire RS-485/232 for Modbus by default

-Ethernet (optional) - for communication with

Physical interface ACS/automated control system/

-wire RS-485/232 for Modbus - for communication with

a surface downhole measuring system

Modbus RTU

Frame Transmission
up to 115200 bps

Construction

Parameter Value

DC bus Choke Built-in

Sine filter Built-in

Capacitor unit (for voltage sags) Option, outdoor

Braking IGBT Option, built-in

Braking resistor Option, outdoor

Electrical power meter Option, built-in

GPRS router Option, built-in

17
VSD configuration
Parameter Value

Change of frequency task increment 0,1 Hz

Efficiency 96 %

PID mode YES

UMKA03 controller with a 7-inch monochrome screen,


push-button control;

UMKA07 controller with LCD-TFT 7 inch display,


HMI
push-button control (touch screen optional);

Integration of third-party controller

PWM frequency Up to 8 kHz depending on VSD type

Speed maintenance accuracy (static) +/- 10% of rated speed in open-loop system

- vector control in an open-loop system without speed


feedback (for PMM)

Control type
- scalar control: based on the characteristic voltage /
frequency U / F (for induction motors)

- linear, from 0.1 Hz / s;

Acceleration and deceleration rates - program mode with adjustable time of reaching given
frequency

Standards

ISO 9001:2015
 2014/35/EU 
 2014/30/EU 
 RETIE

Quality Low Voltage Electromagnetic UL 61800-5-1


management Directive compatibility Standard for
systems – directive Adjustable Speed
Requirements Electrical Power
Drive Systems

18
VSD AK06 CP

(CLEAN POWER)
The Variable Speed Drive AK06 CP (Clean Power) line combines an innovative roster
of unique technologies, which creates the maximum benefits for implementing
cleaner power solutions. This line enables a minimum level of distortion to the input
network, due to built-in passive harmonic filter technology. The NEMA4/NEMA4X
enclosure, together with the passive filter, is a reliable solution for harsh operating
conditions. This line is also capable of meeting high demands for supply voltage
quality.

Triol's specialized control algorithms provide efficient control of installations with


induction or permanent magnet motors, as well as compliance with the requirements
of the IEEE519 standard, in the 25-120% load range. VSD AK06 CP products are
available in 6- and 12-pulse designs, which enable integration of the drive into a wide
variety of power supply systems in the field.

Built-in passive
harmonic filter
Operating temperature range 

-20 °С ... + 60 °С (-4°F...+140°F)
Enclosure - NEMA4,
NEMA4X
Controller
screen "6 or 7"
Onshore and offshore
application
Induction and

PM motors control
Output voltage and
current sinusoidal

6\12 pulses VSD

CE certified

THD THDu, THDi ≤5%


19
Overall dimensions
Rated current Rated power,Full output Width, Depth,
Height,
Mass
kVA
(output current),
power, (with sine Cabinet mm mm mm (max),
Amps
kVA wave filter) (inch)
(inch)
(inch)
kg (lb)
100 83 75
160 133 120 №1 1725
1210
1955
1010

(67.91)
(47.64)
(76.97)
(2227)

250 208 187


300 249 224
360 299 269 1800
1110
2005
1200

№2 (70.87)
(43.7)
(78.94)
(2646)

400 333 299


420 349 314
515 428 385
590 491 441 2100
1210
2000
1350

№3 (82.68)

(47.64)
(78.74)
(2976)

630 524 471


675 561 505
800 665 599 №4 2360
1210
2000
2000

(92.91)

(47.64)
(78.74)
(4409)

900 748 673 2800


1250
2205
2600

№5 (110.2)
(49.8)
(86.81)
(5732)

1000 831 748

Up to 2000 Amps VSD’s available on tandem drives

*Overall dimensions and mass may have slight deviations

**Power for 480V supply voltage; for 380V supply voltage, reduce power 21%

20
Input parameters

Parameter Value

3x380 ± 15% / 3x480 (-15% ... + 10%)

Power supply, V -50% continuously with reduced output power;

-65% up to 500 ms (with a decrease of output power)

Input frequency, Hz 50/60 (-5 %...+5 %)*

*±1 Hz for VSD with built-in passive filter

<5% in the load range from 25%* to 100%

Level of current distortion in the input

* operation in the extended load range is optional when


network THDi,%

specified in the order

Output parameters

Parameter Value

Rated output current, A 100 - 2000

Overcurrent characteristics 120% of rated value for 60 sec

1.5 - 80 Hz, in induction motor control mode

Output frequency 1.5 - 200 Hz, in permanent magnet motor control mode

Up to 600 Hz, in high-speed PMM control mode

Maintain parameters

Parameter Value

Light alarm “Work”, “Waiting”, “Stop”, “Backspin”

Operator control voltage :


Option

10 V DC, +/- 2% current not more than 30 mA,

24 V, 300 mA

110/220 V, 10A for connecting of third-party consumers

Insulation Galvanic isolation between power and user circuits

Insulation resistance > 5 MOhm

Overcurrent protection;

Protection type Power switched temperature (I GBT);

Max. and min. voltage in the D C link.

Enclosure material Carbon steel, stainless steel

Relative humidity 100 %

21
Air-to-air heat exchanger for power compartment

Cooling type cooling; forced air for cooling elements of the power

circuit

Inputs/Outputs

Parameter Value

Number of AI 2 by default, optional extension +8

Programmable 4..20 mA, 0..5 mA, 0..10 V (frequency


AI type
reference / multifunction analog input)

Number of DIN 2 by default, optional extension +4 or more

Option, 4 or more programmable 4..20 mA, 0..5 mA,


Number of AO
0..10 V

Number of Relay Outputs Option, 8

Communication

Parameter Value

Communication port Modbus

-2-wire RS-485/232 for Modbus by default

-Ethernet (optional) - for communication with

Physical interface ACS/automated control system/

-wire RS-485/232 for Modbus - for communication with

a surface downhole measuring system

Modbus RTU

Frame Transmission
up to 115200 bps

Construction

Parameter Value

DC bus Choke Built-in

Sine filter Built-in

Capacitor unit (for voltage sags) Option, outdoor

Braking IGBT Option, built-in

Braking resistor Option, outdoor

22
Electrical power meter Option, built-in

GPRS router Option, built-in

VSD configuration
Parameter Value

Change of frequency task increment 0,1 Hz

Efficiency 96 %

PID mode YES

UMKA03 controller with a 7-inch monochrome screen,


push-button control;

UMKA07 controller with LCD-TFT 7 inch display,


HMI
push-button control (touch screen optional);

Integration of third-party controller

PWM frequency Up to 8 kHz depending on VSD type

Speed maintenance accuracy (static) +/- 10% of rated speed in open-loop system

- vector control in an open-loop system without speed


feedback (for PMM)

Control type
- scalar control: based on the characteristic voltage /
frequency U / F (for induction motors)

- linear, from 0.1 Hz / s;

Acceleration and deceleration rates - program mode with adjustable time of reaching given
frequency

Passive filter efficiency 98%

Standards

ISO 9001:2015
 2014/35/EU 
 2014/30/EU 



Quality Low Voltage Electromagnetic
management Directive compatibility
systems – directive
Requirements

23
VSD AK06 PS
(PHASE SHIFTING)
The Variable Speed Drive AK06 PS (Phase Shifting) line is another complete
solution for the efficient control of installations with both induction and permanent
magnet motors. VSD AK06 PS line drives have an integrated phase-shifting
autotransformer, which, in combination with the 24-pulse rectifier, provides

a 5% level of harmonic distortion to the input network, in the load range

from 25% to 100%. This performance capability allows operation at frequency


supply deviation ±5%.

VSD AK06 PS products meet compliance requirements for the IEEE 519 standard.

Built-in PSA (phase


shifting autotransformer)
Operating temperature range 

-20 °С ... + 60 °С (-4°F...+140°F)
Enclosure - NEMA4,
NEMA4X
Controller
screen "6 or 7"
Onshore and offshore
application
Induction and

PM motors control
Output voltage and
current sinusoidal
6 12 pulses in same size
18 24

CE certified

THD THDu, THDi ≤5%

24
Overall dimensions
Rated current Rated power,Full output Width, Depth,
Height,
Mass
kVA
(output current),
power, (with sine Cabinet mm mm mm (max),
Amps
kVA wave filter) (inch)
(inch)
(inch)
kg (lb)
100 83 75
160 133 120 №1 1725
1210
1955
1010

(67.91)
(47.64)
(76.97)
(2227)

250 208 187


300 249 224
360 299 269 1800
1110
2005
1200

№2 (70.87)
(43.7)
(78.94)
(2646)

400 333 299


420 349 314
515 428 385
590 491 441 2100
1210
2000
1350

№3 (82.68)

(47.64)
(78.74)
(2976)

630 524 471


675 561 505
800 665 599 №4 2360
1210
2000
2000

(92.91)

(47.64)
(78.74)
(4409)

900 748 673 2800


1250
2205
2600

№5 (110.2)
(49.8)
(86.81)
(5732)

1000 831 748

Up to 2000 Amps VSD’s available on tandem drives

*Overall dimensions and mass may have slight deviations

**Power for 480V supply voltage; for 380V supply voltage, reduce power 21%

25
Input parameters

Parameter Value

3x380 ± 15% / 3x480 (-15% ... + 10%)

Power supply, V -50% continuously with reduced output power;

-65% up to 500 ms (with a decrease of output power)

Input frequency, Hz 50±1 Hz and/or 60±1 Hz

<5% in the load range from 25%* to 100%

Level of current distortion in the input

* operation in the extended load range is optional when


network THDi,%

specified in the order

Output parameters

Parameter Value

Rated output current, A 100 - 2000

Overcurrent characteristics 120% of rated value for 60 sec

1.5 - 80 Hz, in induction motor control mode

Output frequency 1.5 - 200 Hz, in permanent magnet motor control mode

Up to 600 Hz, in high-speed PMM control mode

Maintain parameters

Parameter Value

Light alarm “Work”, “Waiting”, “Stop”, “Backspin”

Operator control voltage Option


:
10 V D C , +/- 2% current not more than 30 mA,

24 V, 300 mA

110/220 V, 10A for connecting of third-party consumers

Insulation G alvanic isolation b etween power and user circuits

Insulation resistance > 5 MOhm

Overcurrent protection;

Protection type Power switched temperature (I GBT);

Max. and min. voltage in the D Clink .

E nclosure material C b ar on steel, stainless steel

Relative humidity 100 %

C ooling type F orced air

26
Inputs/Outputs

Parameter Value

Number of AI 2 by default, optional extension +8

Programmable 4..20 mA, 0..5 mA, 0..10 V (frequency


AI type
reference / multifunction analog input)

Number of DIN 2 by default, optional extension +4 or more

Option, 4 or more programmable 4..20 mA, 0..5 mA,


Number of AO
0..10 V

Number of Relay Outputs Option, 8

Communication

Parameter Value

Communication port Modbus

-2-wire RS-485/232 for Modbus by default

-Ethernet (optional) - for communication with

Physical interface ACS/automated control system/

-wire RS-485/232 for Modbus - for communication with

a surface downhole measuring system

Modbus RTU

Frame Transmission
up to 115200 bps

Construction

Parameter Value

DC bus Choke Built-in

Sine filter Built-in

Capacitor unit (for voltage sags) Option, outdoor

Braking IGBT Option, built-in

Braking resistor Option, outdoor

Electrical power meter Option, built-in

GPRS router Option, built-in

27
VSD configuration

Parameter Value

Change of frequency task increment 0,1 Hz

Efficiency 96 %

PID mode YES

UMKA03 controller with a 7-inch monochrome screen,


push-button control;

UMKA07 controller with LCD-TFT 7 inch display,


HMI
push-button control (touch screen optional);

Integration of third-party controller

PWM frequency Up to 8 kHz depending on VSD type

Speed maintenance accuracy (static) +/- 10% of rated speed in open-loop system

- vector control in an open-loop system without speed


feedback (for PMM)

Control type
- scalar control: based on the characteristic voltage /
frequency U / F (for induction motors)

- linear, from 0.1 Hz / s;

Acceleration and deceleration rates - program mode with adjustable time of reaching given
frequency

Passive filter efficiency 98%

28
VSD AK06 RD
(RIGHT DRIVE)
The Variable Speed Drive AK06 RD (Right Drive) line is a reliable and cost-effective
solution to control submersible units of electric submersible pumps and surface
pumping installations. This line is suitable for operating conditions from -20 ° C to +
50 ° C, with a NEMA3R enclosure.

A wide range of dedicated control algorithms provides an integrated solution for


varied production tasks. The rated output current of this line varies from 100 A to
3000 A, the supply voltage is 380 V, 50 Hz and/or 480 V 60 Hz (versions with supply
voltage up to 550 V are available).

Operating temperature range

-20°С …+50°С (-4°F...+122°F)

Enclosure - NEMA3R

Controller screen
"6 or 7"

Onshore application

Induction and

PM motors control

Output voltage and


current sinusoidal

pulse VSD in

6\12 same size

CE certified

29
Overall dimensions
Rated current Rated power,Full output Width, Depth,
Height,
Mass
kVA
(output current),
power, (with sine Cabinet mm mm mm (max),
Amps
kVA wave filter) (inch)
(inch)
(inch)
kg (lb)
100 83 75
160 133 120 №1 900
825
1900
330

(35.43)
(32.48)
(74.8)
(727.5)
250 208 187

300 249 224


360 299 269 910
850
1910
360

№2 (35.83)
(33.46) (75.2)

(793.7)

400 333 299

420 349 314


515 428 385
590 491 441 1230
1090
2000
700

№3 (48.43)
(42.91)
(78.74)
(1543)

630 524 471

675 561 505


800 665 599 №4 1450
1100
1910
770

(57.09)
(43.31)

(75.2)

(1698)

900 748 673 1970


1100
1980
1070

№5 (77.56)
(43.31) (77.95)
(2359)

1000 831 748

1200 998 898


1400 1164 1048 2180

№6 (85.83)
1100
2140
1280

(43.31) (84.25)
(2822)

1600 1330 1197


Up to 3000 Amps VSD’s available on tandem drives

*Overall dimensions and mass may have slight deviations

**Power for 480V supply voltage; for 380V supply voltage, reduce power 21%

30
Input parameters

Parameter Value

3x380 ± 15% / 3x480 (-15% ... + 10%)

Power supply, V -50% continuously with reduced output power;

-65% up to 500 ms (with a decrease of output power)

Input frequency, Hz 50/60 (-5 %...+5 %)

Output parameters

Parameter Value

Rated output current, A 100 - 3000

Overcurrent characteristics 120% of rated value for 60 sec

1.5 - 80 Hz, in induction motor control mode

Output frequency 1.5 - 200 Hz, in permanent magnet motor control mode

Up to 600 Hz, in high-speed PMM control mode

Maintain parameters

Parameter Value

Light alarm “Work”, “Waiting”, “Stop”, “Backspin”

Operator control voltage Option:

10 V DC, +/- 2% current not more than 30 mA,

24 V, 300 mA

110/220 V, 10A for connecting of third-party consumers

Insulation G alvanic isolation b etween power and user circuits

Insulation resistance > 5 MOhm

Overcurrent protection;

Protection type Power switched temperature (I G T


B );

Max. and min. voltage in the DC link .

E nclosure material Car b on steel, stainless steel

Relative humidity 9 5 %

Cooling type F orced air

31
Inputs/Outputs

Parameter Value

Number of AI 2 by default, optional extension +8

Programmable 4..20 mA, 0..5 mA, 0..10 V (frequency


AI type
reference / multifunction analog input)

Number of DIN 2 by default, optional extension +4 or more

Option, 4 or more programmable 4..20 mA, 0..5 mA,


Number of AO
0..10 V

Number of Relay Outputs Option, 8

Communication

Parameter Value

Communication port Modbus

-2-wire RS-485/232 for Modbus by default

-Ethernet (optional) - for communication with

Physical interface ACS/automated control system/

-wire RS-485/232 for Modbus - for communication with

a surface downhole measuring system

Modbus RTU

Frame Transmission
up to 115200 bps

Construction

Parameter Value

DC bus Choke Built-in

Sine filter Built-in

Capacitor unit (for voltage sags) Option, outdoor

Braking IGBT Option, built-in

Braking resistor Option, outdoor

Electrical power meter Option, built-in

GPRS router Option, built-in

32
VSD configuration
Parameter Value

Change of frequency task increment 0,1 Hz

Efficiency 96 %

PID mode YES

UMKA03 controller with a 7-inch monochrome screen,


push-button control;

UMKA07 controller with LCD-TFT 7 inch display,


HMI
push-button control (touch screen optional);

Integration of third-party controller

PWM frequency Up to 8 kHz depending on VSD type

Speed maintenance accuracy (static) +/- 10% of rated speed in open-loop system

- vector control in an open-loop system without speed


feedback (for PMM)

Control type
- scalar control: based on the characteristic voltage /
frequency U / F (for induction motors)

- linear, from 0.1 Hz / s;

Acceleration and deceleration rates - program mode with adjustable time of reaching given
frequency

Standards

ISO 9001:2015
 2014/35/EU 
 2014/30/EU 



Quality Low Voltage Electromagnetic
management Directive compatibility
systems – directive
Requirements

33
VSD AK06 LH

(LOW HARMONIC)
The Variable Speed Drive AK06 LH (Low Harmonic) line is a reliable and value-focused
solution based on the RD (Right Drive) line, for applications that require compliance
with the IEEE519 standard in the main operating range of the installation. VSD AK06
LH products provide a minimum level of distortion to the input network, due to the
built-in passive harmonic filter.

The rated output current of VSD AK06 LH products is from 100 A to 2000 A, the
supply voltage is 380 V, 50 Hz and/or 480 V, 60 Hz. Triol provides efficient control of
installations via induction and valve motors with specialized authoring control
algorithms.

Built-in passive
harmonic filter
Operating temperature range
-20°С …+50°С (-4°F...+122°F)
Enclosure - NEMA3R
Controller
screen "6 or 7"
Onshore application
Induction and

PM motors control
Output voltage and
current sinusoidal

6\12 pulses VSD

CE certified

THD THDu, THDi ≤5%

34
Overall dimensions
Rated current Rated power,Full output Width, Depth,
Height,
Mass
kVA
(output current),
power, (with sine Cabinet mm mm mm (max),
Amps
kVA wave filter) (inch)
(inch)
(inch)
kg (lb)
100 83 75
160 133 120 №1 1275
825
1900
800

(50.2)
(32.48)
(74.8)
(1764)

250 208 187


300 249 224
360 299 269 1360
850
1910
960

№2 (53.54)
(33.46) (75.2)
(2116)

400 333 299


420 349 314


515 428 385
590 491 441 1660
1090
2000
1220

№3 (65.35)

(42.91)
(78.74)
(2690)

630 524 471


675 561 505
800 665 599 №4 2120
1100
1910
1795

(83.46)

(43.31)
(75.2)

(3957)

900 748 673 2650


1100
1980
2020

№5 (104.3)

(43.31) (77.95)
(4453)

1000 831 748

Up to 2000 Amps VSD’s available on tandem drives

*Overall dimensions and mass may have slight deviations

**Power for 480V supply voltage; for 380V supply voltage, reduce power 21%

35
Input parameters

Parameter Value

3x380 ± 15% / 3x480 (-15% ... + 10%)

Power supply, V -50% continuously with reduced output power;

-65% up to 500 ms (with a decrease of output power)

Input frequency, Hz 50±1 Hz and/or 60±1 Hz

<5% in the load range from 25%* to 100%

Level of current distortion in the input

* operation in the extended load range is optional when


network THDi,%

specified in the order

Output parameters

Parameter Value

Rated output current, A 100 - 2000

Overcurrent characteristics 120% of rated value for 60 sec

1.5 - 80 Hz, in induction motor control mode

Output frequency 1.5 - 200 Hz, in permanent magnet motor control mode

Up to 600 Hz, in high-speed PMM control mode

Maintain parameters

Parameter Value

Light alarm “Work”, “Waiting”, “Stop”, “Backspin”

Operator control voltage Option


:
10 V D C , +/- 2% current not more than 30 mA,

24 V, 300 mA

110/220 V, 10A for connecting of third-party consumers

Insulation G alvanic isolation b etween power and user circuits

Insulation resistance > 5 MOhm

Overcurrent protection;

Protection type Power switched temperature (I GBT);

Max. and min. voltage in the D Clink .

E nclosure material : C b ar on steel

Relative humidity 9 5 %

C ooling type F orced air

36
Inputs/Outputs

Parameter Value

Number of AI 2 by default, optional extension +8

Programmable 4..20 mA, 0..5 mA, 0..10 V (frequency


AI type
reference / multifunction analog input)

Number of DIN 2 by default, optional extension +4 or more

Option, 4 or more programmable 4..20 mA, 0..5 mA,


Number of AO
0..10 V

Number of Relay Outputs Option, 8

Communication

Parameter Value

Communication port Modbus

-2-wire RS-485/232 for Modbus by default

-Ethernet (optional) - for communication with

Physical interface ACS/automated control system/

-wire RS-485/232 for Modbus - for communication with

a surface downhole measuring system

Modbus RTU

Frame Transmission
up to 115200 bps

Data format 8 bits 1 stop bit, no parity

Number of addresses 1 .. 255 addresses for Modbus

Access method Slave

Construction

Parameter Value

DC bus Choke Built-in

Sine filter Built-in

Capacitor unit (for voltage sags) Option, outdoor

Braking IGBT Option, built-in

Braking resistor Option, outdoor

37
Electrical power meter Option, built-in
GPRS router Option, built-in

VSD configuration
Parameter Value

Change of frequency task increment 0,1 Hz

Efficiency 96 %

PID mode YES

UMKA03 controller with a 7-inch monochrome screen,


push-button control;

UMKA07 controller with LCD-TFT 7 inch display,


HMI
push-button control (touch screen optional);

Integration of third-party controller

PWM frequency Up to 8 kHz depending on VSD type

Speed maintenance accuracy (static) +/- 10% of rated speed in open-loop system

- vector control in an open-loop system without speed


feedback (for PMM)

Control type
- scalar control: based on the characteristic voltage /
frequency U / F (for induction motors)

- linear, from 0.1 Hz / s;

Acceleration and deceleration rates - program mode with adjustable time of reaching given
frequency

Passive filter efficiency 98%

Stan dards

EN EN
ISO 9001:2015
 EN 61000-6-4 
 EN 61000-6-2 

Quality Electromagnetic Electromagnetic
management compatibility compatibility
systems –
Requirements

38
VSD AK06 FC
(FLEXIBLE CABINET)
The Variable Speed Drive AK06 FC (Flexible Cabinet) line is a versatile NEMA4
enclosure solution which complies with the NEMA 250-2014 standard. Enclosures in
the VSD AK06 FC line are specially designed to support integration of third-party
variable speed drives into their cabinets.

VSD AK06 FC line cabinets include input switching controls and protective equipment,
an output sine filter, and an air-to-air heat exchanger for use in submersible and
surface pumps. An input passive harmonic filter can be integrated into the cabinet of
VSD AK06 FC line products. The high degree of protection and built-in power bay
locking system ensure reliable and safe use of the cabinet in outdoor and harsh
conditions.

Operating temperature range


-20°С …+40°С (-4°F...+104°F)

Enclosure - NEMA4

Built-in sine wave filter

Features of the VSD AK06 FC Line (including Variable Frequency Drives):


Cabinets (enclosures) are designed to integrate third-party variable frequency drives

Built-in sine filter provides THDi and THDu output <5%

NEMA4 enclosure

Operating temperature: from -20 ° C to + 55 ° (-4°F to +131°F)

39
Specifications

Parameter Value

Power supply, V 3х380 ±15% / 3х480 (-15 % ...+10 %)

Input frequency, Hz 50±1 Hz and/or 60±1 Hz

Rated output current, A 100 – 675

Overcurrent characteristics 120% of rated value within 60 sec

Change of frequency task increment 0,1 Hz

Level of distortion in the output



<5%
current THDi,%

Level of distortion in the output



<5%
voltage THDi,%

DC bus choke Built-in

Sine filter Built-in

PWM frequency, kHz >=2,5

HMI Process controller integration as per customer request

Local alarm Optional

Operator Control Voltage Optional: specified upon order

Enclosure material Carbon steel

Relative humidity 95 %

Cooling type Forced air

*Overall dimensions and mass may have slight deviations

**Power for 480V supply voltage; for 380V supply voltage, reduce power 21%

40