You are on page 1of 2

Addition of description to

FANUC Series 30i/31i/32i -MODEL B Plus


CONNECTION MANUAL (HARDWARE)

1. Type of applied technical documents

FANUC Series 30i -MODEL B Plus


FANUC Series 31i -MODEL B Plus
Name
FANUC Series 32i -MODEL B Plus
CONNECTION MANUAL (HARDWARE)

Spec.No./Version B-64723EN/01

2. Summary of change

New, Add,
Applicable
Group Name / Outline Correct,
Date
Delete
Basic
Function
Optional
Function

Unit

Maintenance
parts

Notice

Correction

Addition of description to “3.9 INSTALLATION


Another CONDITION FOR UL RECOGNITION” Add Immediately

TITLE Addition of description to


FANUC Series 30i/31i/32i/-MODEL B Plus
CONNECTION MANUAL (HARDWARE)
DRAW. NO. CUST.
01 200109 Miyashita New B-64723EN/01-01
SHEET
EDIT. DATE DESIG. DESCRIPTION 1/2

A description of the caution mark is added in “3.9 INSTALLATION CONDITION FOR UL
RECOGNITION”

3.9 INSTALLATION CONDITION FOR UL RECOGNITION

3.9.1 Outline
For UL recognition of the product, FANUC Series 30i/31i/32i-MODEL B Plus shall be installed
after due considerations on UL requirements.

3.9.2 Notes on the installation conditions for UL recognition


 Set up the LCD-mounted type control unit, display unit and MDI unit on a flat surface of a
Type 1 Enclosure *1.
*1: Type 1 Enclosure is defined in standard UL 50 as follows.
- Enclosures constructed for indoor use to provide a degree of protection to
personnel against incidental contact with the enclosed equipment and to provide a
degree of protection against falling dirt.
 Use CNC, Display and MDI unit in Pollution degree 2 *2 environment or cleaner environment,
except for part exposed on the outside of enclosure.
*2: Pollution degree is a classification according to the amount of pollution and condensation
present in the environment.
"Pollution Degree 2" is defined in the standard UL 508 as follows.
- Normally, only nonconductive pollution occurs; however, temporary conductivity
caused by condensation may be expected.
 Maximum surrounding air temperature rating: +60C *3
*3: This temperature rating is a condition of UL evaluation for recognition. However, for
long-term reliability, the cabinet should be actually designed in accordance with the
maximum operating surrounding air temperature that described in the subsection 3.1.2 in
the connection manual (B-64723EN).
 Power supply unit for this unit must have an isolating device and the DC 24 Volt output must
be isolated from AC mains supply.
(This isolation can be achieved with the use of the isolating DC power supply unit that
complies with UL standard.)
DC 24 Volt power cable needs to be used with 14AWG or 16AWG size conductors.

For details, refer to “INSTALLATION CONDITION FOR UL RECOGNITION” at the


following URL:
https://www.fanuc.co.jp/en/product/stddoc/

The mark “ ” printed on the nameplate of the control unit indicates that “INSTALLATION
CONDITION FOR UL RECOGNITION” is described in the above URL.

TITLE Addition of description to


FANUC Series 30i/31i/32i/-MODEL B Plus
CONNECTION MANUAL (HARDWARE)
DRAW. NO. CUST.
B-64723EN/01-01
SHEET
EDIT. DATE DESIG. DESCRIPTION 2/2