You are on page 1of 6

UVN SERIES OUT

VARIABLE VOLUME VANE UNI-PUMP

UVN Series Variable Volume Vane Uni-pump 3 to 26cm3/rev M


IN DR
(NSP Uni-pump) 8MPa{81.6kgf/cm2}

B Features
1. Energy efficient high performance 2.Lightweight, compact design 3.Low noise, long life
Vane Pumps

All the performance of a vane pump, The pump and motor are designed for The pump and motor shaft are linked by
B right from the low pressure range, is en-
hanced even further by eliminating the
exclusive uni-pump use, making them
lightweight, compact, easy to handle,
a joint, which minimizes noise by elimi-
nating the effects of shaft vibration and
external drain and optimizing the pres- and suitable for a wide range of appli- an off-center shaft.
sure balance, creating a design that cations. The coupling is constructed to allow
generates little heat. constant lubrication, for friction-free
C The result is a pump that contributes to
the energy efficiency of the mother ma-
long life.

chine, as well as to process precision.

D Specifications
Pump Capacity Pressure Adjustment Range No-load Discharge Rate ℓ/min

E
Model No.
cm3/rev MPa{kgf/cm2} 50Hz 60Hz

UVN-1A-0A2- 0.7
1.5
-4-12 1.5 to 4.0 {15.3 to 40.8}

UVN-1A-0A3- 0.7 -4-12 8.1 3.5 to 6.0 {35.7 to 61.2} 12 14.5

F
1.5

UVN-1A-0A4- 0.7
1.5
-4-12 5.5 to 8.0 {56.1 to 81.6}

UVN-1A-1A2- 1.5
2.2
-4-12 1.5 to 4.0 {15.3 to 40.8}

G UVN-1A-1A3- 1.5
2.2
-4-12 16.1 3.5 to 6.0 {35.7 to 61.2} 24 29

UVN-1A-1A4- 1.5
2.2
-4-12 5.5 to 8.0 {56.1 to 81.6}

UVN-1A-2A2- 2.2
H 3.7
-4-30 2.0 to 4.0 {20.4 to 40.7}

UVN-1A-2A3- 2.2
3.7
-4-30 26.0 3.5 to 6.0 {35.7 to 61.2} 39 46

UVN-1A-2A4-3.7-4-30 5.5 to 7.0 {56.1 to 71.4}

I Note1) Contact your agent for combinations other than those noted above.
Note2) Due to the change of designs from 11 to 12, 20 to 30, the color of paint is changed to black.

J Explanation of model No.


UVN – 1 A – 1 A 4 – 1.5 – 4 – 12

K
Design number
Number of motor poles 4P
Motor output (kW) *Power supply AC200V-50/60Hz AC220V-60Hz
0.7: 0.75kW 1.5: 1.5kW 2.2: 2.2kW

L
Pressure adjustment range
2: 1.5 to 4.0MPa {15.3 to 40.8kgf/cm2} 3: 3.5 to 6.0MPa {35.7 to 61.2kgf/cm2}
4: 5.5 to 8.0MPa {56.1 to 81.6kgf/cm2}
Flow characteristics A: Constant discharge type

M
Discharge rate (At N=1800min –1)
0: 14.5 ℓ/min (max) 1: 29 ℓ/min (max)
A: Foot type mounting
Pump size 1: VDN-1B

N UVN Series Uni-pump

B-40
UVN –1 A – 2 A 3 – 3.7 A E – 4 * – 30
Design number
Voltage symbol
Number of motor poles 4P
Special processings None: Standard
E: Tropicalization

B
Terminal box position None: B terminal
A: A terminal
Motor output
2.2: 2.2kW 3.7: 3.7kW

Vane Pumps
B
Pressure adjustment range
2: 2.0 to 4.0MPa {20.4 to 40.7kgf/cm2} 3: 3.5 to 6.0MPa {35.7 to 61.2kgf/cm2}
4: 5.5 to 7.0MPa {56.1 to 71.4kgf/cm2}
Flow characteristics A: Constant discharge type

C
Discharge flow rate (At N=1800min –1)
2: 46 ℓ/min (max)
A: Foot type mounting
Pump size 1: VDN-1B

D
UVN Series Uni-pump

•Handling 3.Management of Hydraulic Operat- After adjustment is complete, se-


1.Installation and Piping Precautions ing Fluid curely tighten the lock nut.

E
zProvide a mounting base of sufficient zUse only good-quality hydraulic op- cFactory Default P-Q Settings (Stan-
rigidity, and install so that the pump erating fluid with a kinematic viscosi- dard Model)
shaft is oriented horizontally. ty at a oil temperature of 40°C within • Flow Rate Setting = Maximum flow rate
xMake sure the flow rate of the suc- the range of 30 to 50mm2/sec (30 to for model as indicated in the catalog
tion piping is no more than 2m/s, and 50cSt). Normally, you should use an • Pressure Setting = Pressure shown in
that the suction pressure at the pump
suction port is in the range of -0.03 to
R&O type and wear-resistant type of
ISO VG32 or 46, or equivalent.
xThe operating temperature range is
table below
Factory Default
Pressure Settings
F
+0.03MPa. MPa{kgf/cm2}
cDrain piping must be direct piping 15 to 60°C. When the oil temperature
2 : 3.5 {35.7}
up to a point that is below the tank at startup is 15°C or less, perform a
G
3 : 5.0 {51.0}
fluid level, and back pressure due to warm-up operation at low pressure
until the oil temperature reaches 15°C. 4 : 7.0 {71.4}
pipe resistance should not exceed
0.01MPa. Use the pump in an area where the vAll adjustments, except the flow vol-
Provide a suction strainer with a fil- temperature is within the range of 10 ume adjusting screw, are precision
tering grade of about 100 μm (150 to 40°C.
H
adjusted at the factory during assem-
mesh). cFor the return line to the tank, use a bly, do not adjust them.
25μm line filter.
(Do not make any adjustments other than
2.Running Precautions vManage hydraulic operating fluid so
the pressure adjustment screw and the
zThe direction of rotation is clockwise contamination is maintained at class flow rate adjusting screw.)
NAS10 or lower. Take care to avoid
(rightward) when viewed from the
motor fan side. contamination with water, foreign
matter, and other oil, and watch out
Note) The values indicated above are at maxi-
mum pump discharge volume with the flow I
xAt startup, repeat the inching opera- volume adjusting screw at the 0° position.
tion with the pump discharge side at for discoloration. The broken lines show the flow volume
no-load to prime the pump and bleed adjustment range lower limit value.
air from the pump and suction piping.
(This pump has no fluid supply port.)
4.Setting the Pressure and Discharge
Rate
•Inverter Drive Precautions
J
cEquip an air bleed valve in circuits zWhen adjusting pressure, pressure is in-
where it is difficult to bleed air before creased by clockwise (rightward) rotation zSet the revolution speed within the
startup. of the adjusting screw and decreased by range of the pump specification rev-
vMake sure the maximum peak pres-
sure (setting pressure + surge pres-
counterclockwise (leftward) rotation.
After adjustment is complete, securely
olution speed.
xChanging the revolution speed may K
sure) during operation does not ex- tighten the lock nut. also affect the pump performance
ceed 14MPa. xTurn adjustment screw right to decrease curves. Before using the inverter,
or left to increase volume of discharge. check if the pressure and motor load
L
Refer to the following piping condi-
tions as a guideline to keep the max- Refer to guidelines in the following di- factor are within the range of use.
imum peak pressure below 14 MPa. agram for the relationship of the non-
1/2" x 2 m rubber hose (Discharge load volume of discharge and the po-
rate 0; Type 1 14MPa, Type 2 13MPa) sition of the flow adjustment screw.
(pipe volume: approximately 250 cm3)
bInstall a relief valve to cut surges in the
circuit if pressure exceeds 14 MPa.
Flow Adjustment Rotation Angle (θ ) and Pump Capacity (q)
30
M
UVN-1A-2A*(26cm /rev)
3
Pump capacity q cm3/rev

Note) The maximum peak pressure of the dis-


charge rate Type 2 is 13MPa. 25

20 N
16
15 UVN-1A-1A* Note) The values indicated above are at maximum
(16cm3/rev) pump discharge volume with the flow vol-

O
10 ume adjusting screw at the 0° position.
UVN-1A-0A* The broken line shows the flow volume ad-
(8cm3/rev) justment range lower limit value.
5

0
0 90 180 270 360 450
Rotation angle θ °(clockwise)

B-41
Installation Dimension Drawings Installation method is the same as design number 10D (old design).

(128) (61) 90.5 L


72 B terminal (standard) 68.5 P
83 O M8 eye bolt
(A terminal) Flow rate adjusting bolt Outlet terminal

B
(50) 50 A G3/4
Drain port Pump Discharge Port Rotation direction sticker
Rc 1/2 or SAE J518b 1/2 Motor plate (Opposite side)
Rc 1/4 Auxiliary
View X
Pressure adjusting bolt
Vane Pumps

H
17.5

(Vent hole diameter)


B
Pressure adjusting bolt
Flow rate adjusting bolt

I
descend P rise

J
68

increase Q decrease

56
11

38.1
28

φ KD
φ KB
21

C 52

C
4-M8 depth 15
S

G
Auxiliary View X
R* E E Pressure gauge F F
T connection port Pump suction port
M 26 N
Auxiliary View Y Rc 1/4 Rc 3/4

D
69.5 IL
Installation Hole Dimensions Auxiliary View Y
(4 Locations)

E
Output - Motor Dimensions (mm)
Weight
Model No. Poles
kg
(kW-4P) A IL C φ KD E F G H J L M N T×S R* φ KB O P I
0
UVN-1A- 1 A*-0.7*-4-12 0.75-4 20 90 80 157 62.5 50 2.3 120 72 230 155 120 15×10 R5 110 65 130 92 19

F
0
UVN-1A- 1 A*-1.5*-4-12 1.5-4 20 100 90 175 70 62.5 3.2 128 80 255 170 150 15×10 R5 120 65 130 100 23
0
UVN-1A- 1 A*-2.2*-4-12 2.2-4 20 110 100 195 80 70 3.2 138 90 285 200 165 17×12 R6 134 65 135 110 30

- Pump Capacity and Motor Output Category Combinations -

G 0A*
0.75kW
K
1.5kW
K
2.2kW

1A* K K

H Pump Discharge Port


Rc 1/2 or SAE
Hanging bolt J518b 1/2
(3.7kW only) D Hanging bolt Rc1/2 50 134 L
KL KL 17.5 104 IL A

I
Drain port (132) (63) (IN,OUT) Rotation
Rc1/4 O direction plate
72 21 54 Motor rating plate
A,B terminal
38.1

(DR) (Terminal Uni-pump


58

box side) common fan side


Terminal box (Name sticker)
Pressure Terminal box
A terminal 4-M8X15 (Terminal box side)
B terminal
adjusting screw
I2(3.7kW only)

Flow rate adjusting bolt


55 ±0.5 62 ±0.5

descend P rise
increase Q decrease
12

J
Auxiliary View X
I1
28

H
C –0.5
0

φ KD
(Round drain hole) Pump suction port
Pressure adjusting T Rc1
Flow rate adjusting bolt M12

K
screw M10
G

J Pressure gauge F F
S

I1

E E connection port N
M Rc1/4 View R: Mounting foot hole shape
(4 locations) R 2.2kW Electric drive conceptual diagram

L
Motor Dimensions [mm] Output
Frame Weight
Model No. [kW]
No. [kg]

M
A IL C D E F G H I1 I2 J L M N S×T φ KD KL O (4 poles)

UVN-1A-2A*-2.2**-4*-30 179 133 100 206 80 70 7 203 226 − 39 312 206 170 14×12 27 153 83 100L 2.2 46
UVN-1A-2A*-3.7**-4*-30 199 140 112 233 95 70 10 228 253 242 24 339 214 164 14×12 27 182 90 112M 3.7 50
1. Standard drive motor is the fully enclosed fan-cooled E type.

N 2. Standard voltage for drive motor is 200 VAC, 50/60 Hz or 220 VAC, 60 Hz.
3. Standard terminal box is B terminal (right side viewed from pump).
−Pump Pressure Classification and Motor Output Combinations−
2.2kW 3.7kW

O 2A2
2A3
K
K
K
K
2A4 K

B-42
Characteristics of drive motor for unipump (domestic standard 3 rating)

UVN-1A- 0 A*
1
Output Voltage Frequency Current rating RPM rating Heat re-
Poles Model Number
kW [V] [Hz] [A] [min-1] sistance
200 50 4.3 1440
0.75 4 200 60 3.6 1730 E
The drive motor is
specialized for the
220
200
60
50
3.6
7.3
1745
1440 B
1.5 4 unipump and is not 200 60 6.4 1730 E
220 60 6.2 1740

Vane Pumps
a specific model.

B
200 50 10.3 1450
2.2 4 200 60 9.2 1745 E
220 60 8.9 1755

UVN-1A-2A*

C
Output Voltage Frequency Current rating RPM rating Heat re-
Poles Model Number
kW [V] [Hz] [A] [min-1] sistance
200 50 9.5 1460
2.2 4 VAEA-1A4*22-B 200 60 8.8 1750 F
220 60 8.5 1760

3.7 4 VAEA-1A4*37-B
200
200
50
60
15.4
14.3
1460
1760 F D
220 60 13.5 1760

Performance Curves E
UVN-1A-*A*-*-4-12
Operating Fluid: ISO VG 32
Oil temperature: 40°C
F
Motor selection curves
The area under a motor output curve in the graph below is Selection Process
the operating range for that motor under the rated output for
that motor.
Since the intersection of the two broken lines from a pressure
of 3.5MPa and discharge rate of 12ℓ/min intersect in the area G
Example: under the 1.5kW curve, it means that a 1.5kW motor should
To find the motor that can produce pressure of 3.5MPa and a be used.
discharge rate of 12ℓ/min.

* Select a uni-pump that has a pressure and flow rate that is within the range of the drive so that the drive will not overload.
H
* When the startup current of the uni-pump becomes higher for the IE1 motor, breakers may need to be changed.

UVN -1A-0A*(50Hz) UVN -1A-0A*(60Hz)


I
Discharge rate Q ℓ /min

15
Discharge rate Q ℓ /min

15
1.5kW

10
1.5kW
10
J
0.75kW 0.75kW

5 5
K

L
0 2 4 6 8 0 2 4 6 8
{20.4} {40.8} {61.2} {81.6} {20.4} {40.8} {61.2} {81.6}
Discharge pressure P MPa{kgf/cm } 2
Discharge pressure P MPa{kgf/cm } 2

UVN -1A-1A*(50Hz) UVN -1A-1A*(60Hz)

M
35 35
Discharge rate Q ℓ /min
Discharge rate Q ℓ /min

30 30
2.2kW
25 25
2.2kW
20
1.5kW
20
1.5kW N
15 15

10 10

5 5 O
0 2 4 6 8 0 2 4 6 8
{20.4} {40.8} {61.2} {81.6} {20.4} {40.8} {61.2} {81.6}
Discharge pressure P MPa{kgf/cm2} Discharge pressure P MPa{kgf/cm2}

B-43
Motor selection curves (26cm3/rev)

50Hz
UNV-1A-2A* 60Hz
60

50

B
Discharge rate Q ℓ /min

3.7kw
40
Vane Pumps

30
2.2kw
B 20

10
C
0 2 4 6 8
{20.4} {40.8} {61.2} {81.6}
Discharge pressure P MPa{kgf/cm2}
D

E Motor Power Loss at Full Cutoff DR Volume a Full Cutoff

UVN-1A- 0 A*-2.2-4-12
F 1 UVN -1A-*A*-*-4-12(60Hz)
1.0 1.2
Motor axial input kW

0.8 1.0
Drain rate DR ℓ /min

G
0.8
0.6
0.6
0.4 60Hz
0.4

H
50Hz
0.2
0.2

0 2 4 6 8 0 2 4 6 8
Discharge pressure P MPa {20.4} {40.8} {61.2} {81.6}

I FC setting pressure P MPa{kgf/cm }


2

J 1.0
UVN-1A-2A*-3.7-4-30
1.2
UVN -1A-2A*-*-4-30(60Hz)

1.0
Motor axial input kW

0.8
Drain rate DR ℓ /min

K 0.6 60Hz
0.8

0.6
50Hz
0.4

L
0.4

0.2 0.2

0 2 4 6 8 0 2 4 6 8

M Discharge pressure P MPa {20.4} {40.8} {61.2}


FC setting pressure P MPa{kgf/cm2}
{81.6}

B-44
UVN-1A-0A* pump UVN-1A-2A* pump
20 50
1800min-1 Q

Q
B
Discharge rate Q ℓ /min

1800min-1
15 40 1500min-1
2A4
1500min-1

Input Lin kW

Discharge rate Q ℓ /min


0A4
2A3

Vane Pumps
0A3 2A2

B
10 2 30 6

Input Lin kW
0A2

1.5
Lin Lin
5 1 20 4

C
-1
min
00 1 0.5
18 -1
in
-
in
0m m
150 00
0 0 10 18 2
0 2 4 6 8 -1
in

D
{20.4} {40.8} {61.2} {81.6} 0 0m
Discharge pressure P MPa{kgf/cm2} 15

0 0
0 2 4 6 8
{20.4} {40.8} {61.2} {81.6}
Discharge pressure P MPa{kgf/cm2}
E
UVN-1A-1A* pump
40
F
1800min-1
Discharge rate Q ℓ /min

30 Q
1500min -1 G
Input Lin kW

1A4
1A3
20 1A2 4

Lin
3 H
10 2
-1
min

0
18
1 0
5
00 -1
0m
in
1

0
I
0 2 4 6 8
{20.4} {40.8} {61.2} {81.6}
Discharge pressure P MPa{kgf/cm2}
J
*The pressure – flow rate characteristics are the characteristics for individual
UVN pumps. K
The pressure and flow rate must be within the output range of the motor.
See page B-43 for the output ranges of drive motors.

B-45

You might also like