INTRODUCTION
IMPORTANT SAFETY INSTRUCTION ...........................................................................1

ELECTRICAL REQUIREMENTS ................................................................................... 2

PACKING LIST ............................................................................................................3

INSTALLATION&ASSEMBLY INSTRUCTIONS .............................................................. 4

USING YOUR AIR CONDITIONER ................................................................................ 13

OPERATING YOUR AIR CONDITIONER ........................................................................15

CARE AND CLEANING ................................................................................................ 16

TROUBLESHOOTING ................................................................................................. 17
1
15K 18K/22K/24K

2
5/16" Long Hex-head Screw

5/8" Long Hex-head Screw

1/2" Long Hex-head Screw

5/8" Long Flat Head Bolt and


Locknut

Sill Angel Bracket

1/2" Long Flat Head Bolt and


Locknut

Gasket

Support Bracket(with R and L


remark)

3
15K/18K 22K/24K
17.91 18.625
23.625 26.50

19.00 19.50

28.00 30.00
41.00 41.00

4
(15K/18K See FIG.1/FIG.2 ; 22K/24K See FIG.3/FIG.4).

FIG.1
FIG.2
SASH SASH

19 MIN

1/2 MIN 1/2 MIN


19 MIN

1/2 MIN

Storm Window Frame


or Obstruction
Storm Window Frame or Obstruction

FIG.3
FIG.4
SASH SASH

19 1/2 MIN

1/2 MIN 1/2 MIN


19 1/2 MIN

1/2 MIN

Storm Window Frame


Storm Window Frame or Obstruction or Obstruction

5
FIG.5
FIG.6

FIG.5 FIG.6

FIG.7 & 8 FIG.9

FIG.7 FIG.9

FIG.8

6
6.Remove the six screws from the cabinet.(Every side for top,left and right has two screws.) (FIG.10)

FIG.10

FIG.11

FIG.11

8.Take the pearl cotton for 24K(FIG.12).

FIG.12

7
FIG.13a

FIG.13a

5/16
Long
Hex-head
Screw

FIG.13b-
14.

FIG.13b

5/16" Long
Hex-head Screw

FIG.14

(Suggest to keep a downward oblique, to let


accumulated rain water to drain out, from back side
of the unit bottom.)

8
Long Flat head
Bolt and Locknut

5/8" Long Flat Head Bolt

(It should set on the gasket for 22K/24K)

Long
Flat head Bolt
and Locknut

5/8" Long
Hex-head Screw

Gasket

5/8" Long
Hex-head Screw

1/2" Long
Hex-head Screw

9
sash lock

Sash Lock

5/8" Long
Hex-head Screw

FIG.15

10
15K/18K 22K/24K

18 1/4 (46.4 cm) 19 1/2 (49.5 cm)

23 7/8 (60.6 cm) 26 9/10 (68.3 cm)

FIG.16

(Page 6 and 7)

FIG.17

FIG.18

11
FIG.19

FIG.20

12
Cool Mode: The cooling function allows the air
conditioner to cool the room and at the same time
reduces Air humidify. Press the MODE button to
activate the cooling function. To optimize the
function of the air conditioner, adjust the
1 temperature and the speed by pressing the button
indicated.
Dry Mode: This function reduces the humidity of
the air to make the room more comfortable. Press
2 MODE button to set the DRY mode. An automatic
AUTO AUTO
SPEED MODE function of alternating cooling cycles and air fan
3 is activated.
Fan Mode: The conditioner works in only
ventilation. Press MODE button to set the FAN
mode. With pressing FAN SPEED button the
9 8 7 6 5 4 speed changes in the following sequence: Hi, Med
and Lo in FAN mode. The remote control also
stories the speed that was set in the previous
mode of operation.
Auto Mode: In AUTO mode the unit automatically
chooses the fan speed and the mode of operation
(COOL,DRY or FAN).In this mode the fan speed
and the temperature are set automatically
according to the room temperature (tested by the
temperature sensor which is incorporated in the
indoor unit.).

5. Timer Button: Use these buttons on the control


panel and remote to set the Timer.
Timer Off: The timed stop is programmed by
pressing TIMER button. Set the rest time by
pressing the button or until the rest
time displayed is to your demand then press
1. Digital Display: Without timer setting,the TIMER button again.
operation mode is Cooling,Dry, Fan and Auto,and Timer On: When the unit is off, press TIMER
the set temperature will be displayed. button at the first time, set the temperature with
Time will be displayed under timer setting. pressing the button or . Press TIMER
button at the second time, set the rest time with
pressing the button or . Press TIMER
2. and Button: Use these buttons on the button at the third time, confirm the setting, then
control panel and remote to increase or decrease the rest time to next automatical switching-on
the Set Temperature or Timer. could be read on the display of the machine.
Temperature range: 61 ~88 or 16 ~31 .
Note: It can be set to automatically turn off or on in
0.5-24 hours. Each press of the
3. Power Button: Turn the air conditioner on and buttons will increase or decrease the timer. The
off. Timer can be set in 0.5 hours increment below 10
hours and 1 hour increment for 10 hours or above.
The SET light will turn on while setting.
4. Mode Button: Press the mode button to cycle To cancel the setted function, press the TIMER
through the various modes: Cool, Dry, Fan and button again.
Auto.

13
6. Eco Button: When the unit is in ECO mode, the 10. Directional Louvers: To direct the airflow,
light will turn on. In ECO mode, the unit will horizontal wheel to control the horizontal direction,
turn-off once the room is cooled to the user set air deflector to control the vertical direction.
temperature. The fan will also be off at this point.
The unit will turn back on when the room
temperature rises above the user set temperature.
Before the compressor stars, the fan motor will
keep running 10 minutes-stop 20 seconds-and
air deflector horizontal wheel air deflector
again, to provide much more comfortable feeling,
and save the energy.

7. Sleep Button: Press the SLEEP button, the Sleep


Light will be on after 10s, and all the left lights will
be off. In SLEEP mode, the air-conditioner will
automatically adjust the temperature and fan
speed to make the room more comfortable during
the night. The set temperature will automatically
raise by 1 every 30-60 minutes and at most
change six times until the set temperature is 28 .
And every running time depends on the set
temperature.

8. Fan Speed Button: Press the FAN SPEED button


to choose the fan speed options. You can choose
Hi, Med, Lo or auto speed in COOL mode and
choose Hi, Med, Lo in FAN mode.

9. Filter Button: When the Filter Check light is off,


it is useless to press the Filter Check button. When
the Filter Check light is on, it can turn off the light
by pressing the Filter Check button. After the
fan motor works for 500 total hours, the Filter
Check light will turn on to remind the user to clean
the filter.

14
5. Timer: Use these buttons on the control panel
and remote to set the Timer.
Timer Off: The timed stop is programmed by
pressing TIMER button. Set the rest time by
pressing the button or until the rest
time displayed is to your demand then press
TIMER button again.
1 2 Timer On: When the unit is off, press TIMER
button at the first time, set the temperature with
pressing the button or . Press TIMER
3 button at the second time, set the rest time with
7 pressing the button or . Press TIMER
4 button at the third time, confirm the setting, then
the rest time to next automatical switching-on
5 8 could be read on the display of the machine.
Note: It can be set to automatically turn off or on
9
6 in 0.5-24 hours. Each press of the
buttons will increase or decrease the timer. The
10 Timer can be set in 0.5 hours increment below
3 10 hours and 1 hour increment for 10 hours or
above. The SET light will turn on while setting.
To cancel the setted function, press the TIMER
button again.

6. Auto Mode: In AUTO mode the unit automatically


chooses the fan speed and the mode of operation
(COOL,DRY or FAN).In this mode the fan speed
and the temperature are set automatically according
1. Power: Turn the air conditioner on and off. to the room temperature (tested by the temperature
sensor which is incorporated in the indoor unit.).

2. Cool: Press the COOL button to COOL mode. 7. Fan Speed: Press the FAN SPEED button to
choose the fan speed options. You can choose
Hi, Med, Lo or auto speed in COOL mode and
3. and : Use these buttons on the control choose Hi, Med, Lo in FAN mode.
panel and remote to increase or decrease the
Set Temperature or Timer. Temperature range: 8. Display: To press the DISPLAY button, it can
switch off/on all lights or LED display.
61 ~88 or 16 ~31 .
9. Eco: When the unit is in ECO mode, the light
4. Sleep: Press the SLEEP button, the Sleep
will turn on. In ECO mode, the unit will turn-off
Light will be on after 10s, and all the left once the room is cooled to the user set
lights will be off. In SLEEP mode, the temperature. The fan will also be off at this
air-conditioner will automatically adjust the point. The unit will turn back on when the room
temperature and fan speed to make the room temperature rises above the user set
more comfortable during the night. The set temperature.Before the compressor stars, the fan
temperature will automatically raise by 1 motor will keep running 10 minutes-stop 20
every 30-60 minutes and at most change six seconds-and again, to provide much more
times until the set temperature is 28 . And comfortable feeling, and save the energy.
every running time depends on the set
10. Fan Only: Press the Fan Only button to FAN
temperature.
ONLY mode.

15