1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

NPD Weight
Description Qty
[DN] [Kg]
N
A 1 PIPE-WELDED, S-60, A691-1 1/4CR CL.42, 450 5.0 M 1017.1 A
ASME-B36.10M
2 TEMPERATURE NOZZLE, OD45 x 45L, A182-F11 CL.3, DWG 450X25 3 1.1
NO. : SH-TN-AA-1500900
3 REINFORCED NOZZLE, S-60 x S-STD, A182-F11 CL.3, 450X25 1 1.3
DWG NO. : SH-RN-A2B-6000900
4 REINFORCED NOZZLE, S-60 x S-STD, A182-F11 CL.3, 450X20 3 3.3
DWG NO. : SH-RN-A2B-6000900
5 TRANSITION PIECE, S-60, A182-F22 CL.3, 500L, 450 1 205.8
ASME-B36.10M
SEE ISO
B 30LBE50BR001 B
+X=+3650/12-30UMY01
+Y=+2881/B-30UMY01
+Z=+2265 13
11
1092
1.3
7.1
6 30LBE51AA002
STEM N 89.08 U
01-0450-202
30LBE51BR002-SPL-3 S11.1
30LBE51BQ010
C 5 35
4 SH C
SEE DETAIL B
4 3.1
SEE DETAIL B 1.2 450X25NPD 3
ORIENT SEE DETAIL B
DOWN 0.9 SOUTH
348 6 GATE VALVE, CL600, A217-WC6, ASME-B16.34 450 1 2047.0
7 GATE VALVE, CL600, A217-WC6, ASME-B16.34 450 1 2047.0
16 8 THERMOWELL, 260-125, A182-F11 CL.3, DIN 25 1 0.5
SEE ISO
+Z=+2309 12 43772-4-7-M18x1.5 30LBE51CT001
04 30LBE51BR303
9 THERMOWELL, 260-125, A182-F11 CL.3, DIN 25 1 0.5
SEE ISO +X=+3650/12-30UMY01
43772-4-7-M18x1.5 30LBE51CT003
D 30LBE51BR411 +Y=-2540/B-30UMY01 10 THERMOWELL, 260-125, A182-F11 CL.3, DIN 25 1 0.5
D
+X=+3650/12-30UMY01 +Z=+2700 43772-4-7-M18x1.5 30LBE51CT002
+Y=+119/B-30UMY01 1092 11 SPRING HANGER (SH) 450 1 -
+Z=+1961 12 GASKET RING, EN STANDARD, COPPER, 18x22 25 3 0.3
75 13 PLUG SCREW, EN STANDARD, A105, MTE M18x1.5 25 3 0.3
4
30LBE51BR002-SPL-2 SEE ISO
6.1 30LBE51BR302
30LBE51AA001 37 +X=+3650/12-30UMY01
STEM N 89.08 U 4 +Y=-2939/B-30UMY01
01-0450-201 2 +Z=+2707
SEE DETAIL B
E 1.1 E
348
4.3 SEE ISO
450X20NPD 30LBE51BR301
ORIENT 5324.5
+X=+3650/12-30UMY01
UP 0.9 NORTH 7 40 +Y=+2911/A-30UMY01
0 PENGERANG POWER SDN BHD
(Company No. 1089490-K)
+Z=+2713
Level 51, Tower 2, PETRONAS Twin Towers
+Z=+2352 Kuala Lumpur City Centre
348 DETAIL A 50088 Kuala Lumpur, Malaysia
(LOOKING NORTH)
4.2
F 450X20NPD
F
ORIENT PETRONAS PETRONAS TECHNICAL SERVICES SDN BHD
UP 0.9 NORTH 8 40
0
TECHNICAL (Company No. 347848-X)
SERVICES
2.3
Tower 1, PETRONAS Twin Towers
450X25NPD Kuala Lumpur City Centre
+Z=+2358 ORIENT 50088 Kuala Lumpur, Malaysia
EAST 30.0 DOWN 0.5 SOUTH
348
4.1
450X20NPD
DETAIL B ORIENT
(BUTTWELDING END BEVEL TYPE) UP 0.9 NORTH 15 40 8.1/12.1/13.1
G 0
30LBE51CT001 G
9 274
+Z=+2365
10 14

2.1 274 273


450X25NPD 11
ORIENT 30LBE51BR002-SPL-1
UP 0.9 NORTH
13 12
SEE DETAIL A 500 AG Malaysia Sdn Bhd MMC
H 2.2 Siemens AG Siemens Malaysia Sdn. Bhd. MMC Engineering Services Sdn Bhd
H
45
450X25NPD 50 0N Level 1, Reception, CP Tower unit 702, Level 7, Wisma Zelan
+Z=+2371 0 PD PG ES PM No. 11, Jalan 16/11 No. 1, Jalan Tasik Permaisuri 2
ORIENT Pusat Dagang Seksyen 16 Bandar Tun Abdul Razak
WEST 30.0 DOWN 0.5 SOUTH 5.1 63067 Offenbach, Germany 46350 Petaling Jaya, Malaysia 56000 Kuala Lumpur
Malaysia
9.1/12.2/13.2 10.1/12.3/13.3
30LBE51CT003 30LBE51CT002
1 SEONGHWA
Industrial Co., Ltd

PCP-SAG-PIP-ISO-LBE-479529
Ursprung/Original Ursprung-Nr./Original-No. REV Urspr.-PKZ-Nr.
J SEE ISO Orig.-PC J
30LBE51BR001 MY1008-30LBE51-&MTB020-111340 01/00
+X=+3650/12-30UMY01
+Y=+1506/A-30UMY01
+Z=+2387

PENGERANG COGENERATION PLANT MY1008


30LBE51BR002-SPL-1
30LBE51BR002-SPL-2 446539294 &MTC030
INCH-DIA
30LBE51BR002-SPL-3 30LBE51BR002
K SHOP 24.3 479529 K
FIELD 93 SPISO PLMS-P
01_00 2016-06-23 S.W.Kim J.W.Han REVISED AS MARKED
THK THK THK FIELD SHOP 00_02 2016-02-19 S.W.Kim J.W.Han REVISED AS MARKED
(mm) (mm) (mm) in% BW SW RFN FIL in% BW SW RFN FIL Definition 00_01 2016-01-12 S.W.Kim J.W.Han FIRST ISSUE
1 450 S BW 457.0 19.05 Yes 8 20 S O-LET 26.7 2.87 Yes R 100 0 0 0 R 100 0 0 0 Radiographic Examination
00_00 2016-04-11 S.W.Kim J.W.Han RELEASED FOR EXECUTION
9 25 S O-LET 33.4 3.38 Yes 7 20 S O-LET 26.7 2.87 Yes U 0 0 0 0 U 0 0 0 0 Ultasonic Examination.

80
10 25 F FIL 33.4 3.38 No 2 450 F BW 457.0 19.05 Yes P P Liquid Penetration Examination
0 0 0 0 0 0 0 0
11 25 S O-LET 33.4 3.38 Yes 3 450 F BW 457.0 19.05 Yes - -
S 10 0 100 100 S 10 0 100 100 Magnetic Examination
12 25 F FIL 33.4 3.38 No 16 25 S O-LET 33.4 3.38 Yes
L 13 25 S O-LET 33.4 3.38 Yes 4 450 F BW 457.0 19.05 Yes H 10 0 0 0 H 10 0 0 0 Hardness Testing
14 25 F FIL 33.4 3.38 No 5 450 F BW 457.0 19.05 Yes M 10 0 10 10 M 10 0 10 10 Metascope or ferritic check 2016-01-12 M.J.Shin Piping
15 20 S O-LET 26.7 2.87 Yes 6 450 F BW 457.0 19.05 Yes V V Visual Examination 2016-01-12 S.W.Kim
Exportkennzeichnung AL: ECCN:
Remarks
100 100 100 100 100 100 100
The extent of NDE is mandatory for shop and field welds of the
100
2016-01-12 J.W.Han
Isometric 30LBE51BR002
respective piping system as a designated lot.
Bearbeitung dieses Dokumentes, Verwertung und Mitteilung
- Final dimensions of valves and in- line components to be
checked by erection contractor before installation. General Weld type Addition for extent of NDE below 100%: All materials, all nominal pipe sizes Building: 30UMY
gestattet. Zuwiderhandlungen verpflichten zu Schadenersatz.
- Pipe routing NPS < 3" (DN80) should be Position number acc. partlist BW : Butt weld and all welders shall be considered for a random spot examination of welds
bzw bei Kennzeichen "AL:N" oder "ECCN:N", kann sich eine Genehmigungspflicht, unter anderem
checked by erection contractor at site Shop weld number SW : Socket weld Set of Rules for
oder Geschmacks-mustereintragung vorbehalten. Insulation 320 mm
- All pipes without fit-up allowance Field weld number O-LET : Weldolet, sockolet Construction
Transmittal, reproduction, dissemination and/or editing of this Export classification AL: ECCN: - Fit-up allowance of pipe = 150mm, Support type RFN : Reinforce Nozzle
Pipe Material Class A90A1RA0120 max. allow. work. Temperature 470 C 01_00
M document as well as utilization of its contents and Goods labeled with "AL not equal to N" are subject to European or German export authorization which is additional marked with "+150" KKS-support number FIL : Fillet

20
communication thereof to others without express authorization - For Part No. only figure before dot to be Slope SF : Socket Fusion
are prohibited. Offenders will be held liable for payment of
when being exported out of the EU. Goods labeled with "ECCN not equal to N" are subject to US
matched with BOM Part No.
Internal Coating max. allow. work. Pressure 67 bar MY1008-30LBE51-&MTC030-479529
reexport authorization. Even without a label, or with label "AL:N" or"ECCN:N", authorization may be Flow direction F : Field weld
damages. All rights created by patent grant or registration of a - For shop pre-fabrication Referance S : Shop weld
utility model or design patent are reserved.
required due to the final whereabouts and purpose for which the goods are to be used.
drawing no. External Coating MY1008-61810-&MDC080-484504 Test Pressure 100.5 bar 1 /1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16