GENERAL NOTES

BALCONY
1

UP
PB-1

3500
T&B
1

2
1
3

5000

6000
2
4

1. 3

DN
5 17
4
6 16

7 15
5 17 2
PB-1

lav
6 16
8 14
7 15

FD
2. 9 13
8 14

2500
10 12

CARPORT 9 13

wc
11
10 12

11

3.
5450 2950
2 2
PB-1 PB-1

GROUND FLOOR 3200 2000 3200


4.
1 LIGHTING LINE LAYOUT
SCALE 1: 100 M.
E-1 SECOND FLOOR

5. 4 POWER LINE LAYOUT


SCALE 1: 100 M.
E-1
6.

7. PANEL LPP1
8400
CKT CIRCUIT BREAKER
LOAD DESCRIPTION VA VOLT AMP SIZES OF WIRES AND CONDUITS
8. 3100 5300 NO. AT AF POLE KAIC
1 02x100- CEILING LIGHT, 4x100- PIN LIGHT 600 230 2.61 20 50 2 10 2-3.5mm2 THHN + 1-5.5mm2 TW (G) IN 20mm Ø Conduit
1500
2 07 - CONVENIENCE OUTLET 1,260 230 5.48 20 50 2 10 2-3.5mm2 THHN + 1-5.5mm2 TW (G) IN 20mm Ø Conduit

9. 3 ACU 1.5 HP 2300 230 10 30 50 2 10 2-5.5mm2 THHN + 1-5.5mm2 TW (G) IN 20mm Ø Conduit

TOTAL: 3,840 230 18.09 30 50 2 10

BALCONY
IL= ((3,840 VA) /(230V )+(0.25x 15)) x 0.80 DF COMPUTATION:

3500
2
PB-1
Iamp = 17.47 A

USE: 100AT/100AF, 2-POLE, 25KAIC, 240V MCCB


I T = [ 18.09A + (15 x 0.25) ] x 80%
LEGENDS & SYMBOLS: 1

2-30mm² THHN +1-8.ømm² TW (G) IN 32MM Ø RSC

6000
2

= 17.47 A

DN
4

5 17
FEEDER LINE:

lav
M 6

7
16

15
USE 2 - 30 mm2 THHN COPPER WIRE

FD
8 14 1 - 8.0 mm2 TW ( GROUND )

2500
IN 32 mm Ø RSC
CKT. NO.
9 13

wc
PANEL

10 12

11

PANEL LPP1
CKT CIRCUIT BREAKER
3200 2000 3200 LOAD DESCRIPTION VA VOLT AMP SIZES OF WIRES AND CONDUITS
NO. AT AF POLE KAIC
1 02x100- CEILING LIGHT, 4x100- PIN LIGHT 600 230 2.61 20 50 2 10 2-3.5mm2 THHN + 1-5.5mm2 TW (G) IN 20mm Ø Conduit
2 07 - CONVENIENCE OUTLET 1,260 230 5.48 20 50 2 10 2-3.5mm2 THHN + 1-5.5mm2 TW (G) IN 20mm Ø Conduit
SECOND FLOOR 3 ACU 1.5 HP 2300 230 10 30 50 2 10 2-5.5mm2 THHN + 1-5.5mm2 TW (G) IN 20mm Ø Conduit

2 LIGHTING LINE LAYOUT TOTAL: 3,840 230 18.09 30 50 2 10


SCALE 1: 100 M.
E-1 IL= ((3,840 VA) /(230V )+(0.25x 15)) x 0.80 DF COMPUTATION:
Iamp = 17.47 A

USE: 100AT/100AF, 2-POLE, 25KAIC, 240V MCCB


I T = [ 18.09A + (15 x 0.25) ] x 80%
2-30mm² THHN +1-8.ømm² TW (G) IN 32MM Ø RSC

FEEDER LINE:
= 17.47 A
USE 2 - 30 mm2 THHN COPPER WIRE
1 - 8.0 mm2 TW ( GROUND )
8400 IN 32 mm Ø RSC
3100 5300
UP

T&B
1

3
M M

5000
4

5 17

6 16

7 15 MDP 100AT, 2P MDP 100AT, 2P


8 14

9 13 1
10

11
12 PB-1

CARPORT PB1 PB1


60AT, 2P 60AT, 2P

20AT, 2P 30AT, 2P 20AT, 2P 30AT, 2P


5450 2950 1 2 1 2
30AT, 2P 30AT, 2P
3 3
GROUND FLOOR

3 POWER LINE LAYOUT


SCALE 1: 100 M.
E-1 GROUND GROUND

ARCHITECT : CADD BY: DATE: PROJECT TITLE: OWNER: SHEET CONTENT: PROJECT NO:

AS SHOWN
PROPOSED 2 STOREY RESIDENTIAL
D PL AN SHEET NO:

PRC: PTR: LOCATION:


UNP AYE
IAPOA: ISSUED ON: E-1
TIN: ISSUED AT: