tm10293 - 750J Crawler Dozer - 002000.09 - CAN Communication Error,


No ECU Configuration

The CAN monitor unit is not receiving engine control unit configuration.

CAN Communication Error, No ECU Configuration Diagnostic Procedure


Alarm Level:
Check Service Code

1 Software Check

Action:
Observe the ECU software version and hardware by accessing the Machine Settings /
Controller Info / ECU menu in the CMU menu structure. See CAN Monitor Unit (CMU)
Menu Structure—Service Mode . (Group 9015-20.)
Is correct ECU information present?

Record of Actual Results:

Result:
YES:
Go to Reprogram Controller.
NO:
Perform CAN Circuit Test . (Group 9015-20.)

2 Reprogram Controller

Action:
Reprogram CAN monitor unit (CMU).
Check for active codes.
Is CMU code 002000.09 present?

Record of Actual Results:

https://serviceadvisor.deere.com/WebSA/manuals/tm10293/09001faa80660795 1/2
10/25/23, 10:57 AM 002000.09 - CAN Communication Error, No ECU Configuration - tm10293 :: Service ADVISOR™

Result:
YES:
Replace controller.
NO:
Checks complete.

WS68074,0000B65-19-20070305