Model No: DD500788.

4
5" 7/8 Lobes 8.4 Stages
www.dyna-drill.com
USA: 23400 Colonial Parkway, Katy, TX 77493 Tel: (281) 227-1250, Fax:( 281) 227-1255
Canada: Bay E.; 2802- 5th Street, Nisku, Alberta T9E-0H1 Tel:(780) 955-7711, Fax: (780) 955-7833
Dubai: Oilfields Supply Center, Bldg B-30, P.O. Box 261039, Dubai, UEA, Tel: 011-971-4-8100310, Fax: 011-971-4-8100313

POWER SECTION
ROTOR SPECIFICATIONS STATOR SPECIFICATIONS
Inch mm Inch mm
Overall Length 251.6 6391 Overall Length 250.0 6350
Contour Length 235.0 5969 Rubber Cut Back 8.00 203
Eccentricity 0.173 4.38 Tube O.D. 5.00 127.0
Major Diameter 3.354 85.19 Tube I.D. 4.00 101.6
Head Diameter 3.630 92.20

Weight 520 (lbs) 235.9 (kg) Weight 547 (lbs) 248 (kg)
Material 17-4SS Number of Stages 8.4
2 3/8'' Hughes Rubber Type NBR-HR
Thread Form*
Slimline H-90 Tube Material 4142 Seamless Tubing
* Alternate or custom thread forms are available

FIT INFORMATION
POWER SECTION FIT CHANGE
NBR-HR Minor Diameter
Temp Change (C)
10 38 66 93 121 Stator Size Inch mm
0.040 Undersize
____ NBR-HR
0.84 Standard
0.030 Oversize 3.024 76.81
0.63
Inch

mm
Double Oversize 3.039 77.19
0.020
0.42 Nominal Fit at 75 F (25 C)
0.010 0.21 Undersize
Standard
0.000 0 Oversize -0.015 -0.38
0 50 100 150 200 250 Double Oversize -0.030 -0.76
Temp Change (F)

PERFORMANCE SPECIFICATIONS PERFORMANCE DETAILS


NBR-HR
Torque Slope 3.631 ft-lb/psi 0.714 Nm/kPa Max Diff Press psi (kPa) 1890 (13030 )
Flow Range 150 to 350 GPM 570 to 1320 Litre/min Max Torque ft-lb (Nm) 6860 (9300 )
Rotation 0.700 Rev/Gal 0.185 Rev/Litre Stall Diff Press psi (kPa) 2840 (19550 )
Speed Range 105 to 250 RPM Stall Torque ft-lb (Nm) 10290 (13960 )
Off Bottom Press 126 psi 870 kPa Max Recommended HP(kW) 306 (228)

NBR-HR Torque
Power Section Diff Pressure (kPa)
ft-lb

Nm
0 3000 6000 9000 12000
300
8000

Maximum Recommended Diff Pressure


10000

GPM=350 LPM= 1324


240
6000

8000

GPM=250 LPM= 946


180
6000
4000
RPM

120 GPM=150 LPM= 567


4000
2000

2000

60

0
0

0 400 800 1200 1600 2000


Power Section Diff Pressure (psi)

Operating a power section above the maximum recommended differential pressure will reduce stator life. Performance Curves are for reference only. Actual power
section performance may vary depending on the down hole temperature and rotor/stator fit. Performance data are subject to change without notice. Power calculation
is based on maximum RPM and full torque. Stator sizes subject to change without notice. Copyright 2015 Dyna-Drill®. All rights reserved.