SCENARIO NAME
Fuel Pressure Low – Fuel Circulation Pump Worn Out
SYSTEM NAME
Main & Auxiliary Engines Fuel Supply System
SYSTEM DESCRIPTION The system consists of two supply pumps that supply either HFO
or DO from daily tanks via flowmeter into the enclosed
circulating system. The fuel within circulating system circulates
via circulation pumps through heaters/coolers, automatic and
by-pass filter, viscosimeter to generator engine inlet flowmeter
and main engine. Continuous fuel circulation is established
through main engine and auxiliary generator engines and
returned via pressure regulating valve to vent box (mixing tank).
Fuel from vent box (mixing tank) is lead to suction valve of a
running circulation pump. Consumed fuel from circulating system
is refilled into the system with supply pumps. Higer fuel pressure
in the system is from discharge side of circulation pumps to the
pressure regulating valve. (Fig.1.)
SYSTEM OPERATING AND ALARM FO pressure at ME & AE inlet: 7,5 bar (Alarm 6,0 bar)
PARAMETERS Supp. PP LCL DISC Pressure: 3,2 bar
Circ. PP LCL DISC Pressure: 7,8 bar
ALARM TYPE When Fuel Oil Low Pressure is activated following alarms and
changes will be triggered:
- You will hear heavy sound in ER
- Signal light column for machinery alarm is illuminated
- Message on ECR computer panel will appear: “FUEL
PRESSURE LOW – 5,8 bar”
- Pressure gauge at ECR gauge panel will show 5,8 bar
- Pressure at CIRC. PP LCL DISC Gauge will show 6,1 bar
PLANT CONDITION BEFORE TO START Vessel is undreway at full main engine speed and one auxiliry
SCENARIO engine (generator) is in operation. Fuel is consumed from HFO
Serevice tank and heated to 115 °C. Fuel supply pressure at the
inlet to ME & AE is 7,5 bar. In operation is Fuel Oil Circulation
Pump No. 1 (CIRC. PP. No 1). Following indication is shown before
scenario:
- No any sound alarm in ER – SILENCE (only machinery
noise)
- Signal light column for machinery alarm is NOT
illuminated
- NO Messages on ECR computer panel
- Pressure gauge at ECR gauge panel will show 7,5 bar
- Pressure at SUPP. PP LCL DISC Gauge will show 3,2 bar
- Pressure at CIRC. PP LCL DISC Gauge will show 7,8 bar
PICTURES, DRAWINGS, Please attach pictures, schematics, drawings not only for
SCHEMATICS, ETC. describing purposes but also software animation.
(eg.);
Fig. 7.: Alarm horn and signal column (Machinery alarm marked with arrow)
CIRC. PP. No 1 Starter CIRC. PP. No 2 Starter
Fig. 8.: Starters of CIRC. PP. Starters on Main Electrical Switchboard (MSWBD) located in ECR