F0RM NO
CRO005. Rev. 1
SCENARIO NAME
Main Engine Shutdown – Low LO pressure/level
SYSTEM NAME
Main Engine
SYSTEM ER Equipment
EQUIPMENTS/INDICATORS - Main Engine
/GAUAGES/PANELS/COMPONENTS - ECR Contol Panel
Alarm and Montioring Equipment
- Signal Columns in ER (inlcuding horn alarm)
- ECR Alarm Computer Panel (Alarm System)
- ECR Gauge Panel
- Main Engine Safety System Panel – SSU unit
SYSTEM DESCRIPTION Main Engine onboard simulated ship is a crosshead engine of two-stroke
type (Fig.1.). The engine is equipped with two mains LO pumps that
supply main engine with lubricating oil. The pumps are vertical driven
centrifugal pumps that supply lubricating oil into main engine. Main LO
pumps are located at the top of main engine sump tank aft end near
engine flywheel. (Fig.2.). Engine sump tank is the tank that collect all
lubricating oil contained in ME. Engine sump tank is part of ship hull and
is located bellow main engine. Aft part of engine sump tank is extended
below ME flywheel in order that vertical centrifugal pumps can be
located on tank top. Engine sump tank is equipped with sounding pipe
that is used for manual measuring tank level (lubricating oil content).
Low oil content might cause that lubricating pumps cannot supply
enough oil pressure to engine.
SYSTEM OPERATING AND ALARM ME LO pressure: 3,0 bar (Alarm: 1,5 bar, Shutdown; <1,0 bar)
PARAMETERS ME LO level in sump tank: 0,80 mtr, (Alarm LL 0,65 mtr)
ALARM TYPE When LL alarm in engine room sump is reached an alarm will be on ECR
computer panel followed by alarm/light in signal column. If problem is not
solved on time an additional alarm will be triggered ME Low Oıl pressure
and consequently an ME Shutdown function will be activated. Following
alarms and changes will be triggered:
- You will hear heavy sound in ER (beyond sound of running M/E)
- Signal light column for machinery alarm is illuminated
- Message on ECR computer panel will appear: “ME SUMP TANK LL”
If problem is not solved within 5 min sec following alarms and changes will
be triggered:
- You will hear heavy sound in ER and machinery alarm light is
illuminated (if privously not acknowladged and silenced)
- Message on ECR computer panel will appear: “ME OIL PRESSURE
LOW – 1,5 bar” and “ME STAND-BY LO PUMP CHANGE-OVER”
- Local Pressure gauge at ECR control Panel will show 1,5 bar
If problem is not solved within 5 min following alarms and changes will be
triggered:
- Message on ECR computer panel will appear: “ME SHUTDOWN”
- Alarm lamp No. 02 – Main Lube. Oil Low Pressure on SSU unit on
ECR Panel is illuminated/blinking
PLANT CONDITION BEFORE TO Vessel is undreway at full main engine speed and one auxiliry engine
START SCENARIO (generator) is in operation. Present engine speed is 85 rev/min. One
auxiliry engine (generator) is in operation. ME LO Pressure is 3,0 bar.
Following indication is shown before scenario:
- No any sound alarm in ER – SILENCE (only machinery noise and ME
increasing sound)
- Signal light column for machinery alarm is NOT illuminated
- NO Messages on ECR computer panel
- ME LO pressure at ECR Gauge Panel is 3,0 bar.
PICTURES, DRAWINGS, Please attach pictures, schematics, drawings not only for describing
SCHEMATICS, ETC. purposes but also software animation.
(eg.);
Fig. 1.: Cross-section of ME
Fig. 2.: Position of ME LO pumps
Fig. 3.: ECR Panel Gauge – LO Pressure Gauge
Fig. 7.: ME SSU - Safety System Unit Panel installed at ECR panel unit
Fig. 8.: Alarm horn and signal column (Machinery alarm marked with arrow)