Professional Documents
Culture Documents
a r t i c l e i n f o a b s t r a c t
Article history: As tomorrow’s cities are already largely built, many strategies stress the importance of urban renewal
Received 5 February 2016 processes to address current energy issues. This paper focuses on the Spanish residential building stock
Received in revised form 3 February 2017 built until 2001, which has a low level of energy performance.
Accepted 18 March 2017
Considering the current economic crisis, the future lies in renovating the built environment, which
Available online 21 March 2017
holds a significant energy-saving potential. This potential is here quantified by applying the cost-optimal
methodology, initially proposed by the Energy Performance of Buildings Directive, and which calculates
Keywords:
cost-optimal levels of minimum energy performance requirements at the building and component scale.
Cost-optimal methodology
cost-effective strategies
The originality of our study lies in the application of this methodology at the territorial scale, comparing
Urban renewal different retrofitting scenarios by scaling-up building-scale results through an archetypal approach. We
Sustainable retrofit also describe an Excel-based tool allowing two types of studies: (i) at the building scale, for one archetype
Environmental assessment in a particular climatic zone; (ii) at the territorial scale, to have an overview of all building archetypes
Decision-making tool and climatic zones simultaneously. Results include economic aspects, energy consumption and savings
Residential building and associated emissions.
Sustainable architecture The outcome can help construction-sector firms adapt their business plan, while also providing stake-
holders with decision-support to promote a sustainable renewal of the building stock.
© 2017 Elsevier B.V. All rights reserved.
1. Introduction energy [1–5]. Due to the low replacement rate of existing buildings
– about 1–3% per year in EU countries [6] – the majority of buildings
1.1. European and Spanish building stock that will exist in 2050 is already built, with many of them having
a low level of energy performance [7]. In this context, the retrofit
One of the top priorities regarding the built environment in of existing buildings offers significant opportunities for reducing
European countries is to reduce energy consumption and green- energy consumption and GHG emissions [8]. In fact, the Inter-
house gas (GHG) emissions and increase the use of renewable national Energy Agency (IEA) estimates that the potential energy
savings for 2050 are of about 1509 million tonnes of oil equivalent
[9], with a 50–75% saving when considering only the improvement
Abbreviations: CDD, cooling degree days; CE3x, official software for energy per- of the building envelope [10]. It therefore seems clear that the res-
formance certification; CTE, technical building code; DHW, domestic hot water; idential building stock in EU-27 offers high potential for energy
EEM, energy-efficient measures; EPBD, energy performance of buildings directive; efficiency gains [11,12]. This large potential energy saving is par-
EPC, energy performance certification; EU, European Union; GIS, geographic infor- ticularly relevant to the Spanish context [7], where most residential
mation system; GHG, greenhouse gas; GTR, rehabilitation working group; HDD,
heating degree days; HVAC, heating ventilation and air conditioning; LCA, life-
buildings were constructed before 2001, when thermal regulations
cycle assessment; LCC, life-cycle cost; LoD, level of detail; MF, multi-family; MS, were modest [13–18].
member states; NPV, net present value; nZEB, nearly zero energy buildings; ORIG, According to the Energy Performance Certification (EPC) in
current status scenario; PE, primary energy; RD, royal decree; REF01, minor retrofit Spain, which rates buildings from A (best) to G (worst), 96% of the
scenario; REF02, deep retrofit scenario; RET, renewable energy technologies; SF,
certified 1.4 million existing buildings are below the current legal
single-family; PBP, payback period; TABULA, typology approach for building stock
energy assessment; VAT, value-added tax. requirements set at an EPC level C [19]. The EPC rate depends on
∗ Corresponding author. the type of building and the climatic zone where it is located. In
E-mail address: sergi.aguacil@epfl.ch (S. Aguacil).
http://dx.doi.org/10.1016/j.enbuild.2017.03.047
0378-7788/© 2017 Elsevier B.V. All rights reserved.
S. Aguacil et al. / Energy and Buildings 144 (2017) 42–60 43
general, the different levels follow a linear dependency: a build- In parallel, the evolution of EU directives continued. In 2012,
ing with the lowest qualification consumes ten times more than a the 2012/27/EU Directive was presented [34]. It defines the PE and
building with the highest level of performance [20,21]. GHG emissions savings to be achieved, and requires all EU member
The residential building stock as a whole emits about states (MS) to define specific strategies to achieve those objectives.
35 kgCO2 /m2 per year in terms of primary energy (PE) consump- As a result, in the Spanish context, the current legislation does not
tion [22], a value that is far from the ambitious objectives of the EU yet meet the requirements of the latest EU directives.
horizon 2050 for new and existing buildings of around 3 kgCO2 /m2 Therefore, new regulatory changes are necessary in the short
[23]. term in order to reach the required level, because all EU countries
However, by considering only envelope retrofitting, it would be should have submitted plans and regulations for the promotion
possible to reduce the energy used by residential buildings up to of nearly nZEB, as well as measures to promote building energy
25% by 2020 [24]. For the 2050 horizon, the total savings could reach rehabilitation projects following the cost-optimal methodology to
71% in terms of energy and 73% in terms of GHG emission [22]. These ensure the viability of the improvement strategies [17,22,35].
values highlight that it is theoretically possible to achieve the EU’s
20% energy-saving target for 2020, as well as the long term 80–95%
GHG emissions reduction target for 2050. 1.3. Overview of study
Ref. Building typology and database Context Considered measures Main objectives
[43] Single-family (SF) and multi-family (MF) Greece, three climatic zones defined by Passive (add thermal insulation and replace Overview of total consumption and CO2
houses classified in three construction HDD. windows), active (new boiler) and RET (ST emissions of building stock and estimation of
periods (pre-1980, 1981–2000 and after panels for domestic hot water (DHW)) saving potentials. Use of payback period (PBP).
2000). TABLE database. according to two scenarios (standard and
ambitious).
[55] Semi-detached SF house, built in 1945. Portugal, no specified climatic zones. Three groups of measures, including passive Comparison between different construction
(type of insulation) and RET (ST panels for materials. Based on multi-objective evaluation
DHW). using GenOpt and Tchebycheff optimization
technique.
[50] Nine residential buildings built before Portugal, Lisbon climate data Passive strategies (insulation thickness and Use of cost optimal methodology to define
1960, 1960–1990 and after 1990. Concept conditions. windows), six options of HVAC systems with range of optimal U-values for walls, roofs and
of Archetype. CYPE Engineers database. solar thermal panels. windows.
[58] Results of 26,000 renovated dwellings. Spain (Madrid). Passive (add thermal insulation and replace Application of four public plans to help owners
windows). replace windows by more efficient ones; show
that incomes due to value-added tax (VAT)
(related to renovation work) is superior to total
Fig. 1. Total construction in Spain until 2011 (in number of residential buildings and dwellings) [13,14].
Another approach consists in using statistical data to extract scales, for instance to study a regional building stock taking into
statistically relevant parameters [32,46,47]. This information can account different climatic conditions using the Degree Days sim-
be used, as done by Schwehr et al. [48], to define ‘building typolo- plified methodology.
gies’ within the building stock, where each typology corresponds The complex methods [32,53,55] propose advanced simulation-
to a building with the same set of parameters, including period of based multi-objective optimisation, using a combination of tools
construction, context, construction characteristics, and other fea- (EnergyPlus, TRNSYS, MatLab) and genetic algorithms. They are
tures related to the assessment objectives. Making an aggregation commonly applied at a more detailed scale, e.g. to define the opti-
by groups using, for example, the construction period as the main mal choice of materials at the building scale, and try to be as
parameter can then allow obtaining results for a larger scale [49]. accurate as possible [52,56,57].
Another statistics-based concept is that of ‘archetype’, defined as The novel application of the cost-optimal methodology that we
a theoretical model that represents each of the different building propose takes into account these two levels of complexity by defin-
typologies [50]. This method is used to classify the building stock ing a pre-simulated energy demand database of seven archetypes
according to different parameters such as climatic conditions, con- in 12 climatic zones, obtained using the official software (CE3x) [62]
struction period and context. Each archetype definition represents for generating EPC in Spain. Using this software allows us to com-
a major type of dwelling that can be used as input data for energy pare our results to the EPC database of real buildings [7], in order
simulation [51]. Then, the estimation of energy consumption and to test the accuracy of the results at the territorial level, which is
GHG emissions of each archetype can be scaled-up to be repre- our target scale. Therefore, as Spain’s EPC registry becomes more
sentative of the regional or national housing stock. This is done by complete [19], our database may be updated without conflicts.
multiplying the results by the number of dwellings (given by the The pre-simulated database is generated by building upon the
statistical data) which fit the description of each archetype [52]. work conducted by the Rehabilitation Working Group (GTR) [63].
This scaling-up method can also be understood as a bottom-up The GTR, who’s objective is to facilitate the transformation of
approach for representing the building stock. Spain’s building sector, has published three main reports that detail
The general purpose of application of the cost-optimal method- the Spanish legislation, examine the existing housing stock, and
ology is to enable the comparison of scenarios integrating different propose a general operational framework for the building renova-
energy-efficient measures (EEM), or to identify the most cost- tion sector in Spain [64–66]. In our work, the building typologies
optimal combination of EEM. In most cases, the EEM consist of along with their parametric details identified by the GTR from
passive strategies, while a few studies have considered a mix of pas- the statistical census data of 2001 [13] are used to define our
sive and active strategies as well as renewable energy technologies archetypes. This approach allows us to obtain a more detailed, pre-
(RET) [42,43,53]. cise and context-specific database, compared for instance to TABLE
The multi-criteria analyses include outputs such as the Net [45].
Present Value (NPV), global cost, GHG emissions and energy sav- Pre-simulated energy demand data are obtained for the current
ings, sometimes resulting from a full Life Cycle Assessment (LCA) status of each archetype, as well as following two retrofitting strate-
[23,32]. However, all assessments are based on a fixed horizon gies (minor and deep) in which passive strategies are considered.
period and show a unique value for each output as opposed to a Active systems and solar-based RET are then included to define
temporal profile. complete packages of mixed strategies.
Looking at the whole workflow adopted in the different publi- In addition to the standard cost-optimal methodology static out-
cations, we have identified two main different methods: simplified puts, results from a Life-Cycle Analysis (LCA) and Cost (LCC) analysis
and complex. are presented to provide a temporal representation of the differ-
The simplified methods [40,54] propose a simple way to cal- ent retrofitting scenarios, considering the moment of application of
culate the energy demand and an expert system to assist the each EEM. The final contribution of this work is the implementation
decision-making, assuming a certain level of error or uncertainty of the whole workflow into an Excel tool, for use by professionals
in the results. These methods are commonly applied at larger such as planners and policy-makers.
46 S. Aguacil et al. / Energy and Buildings 144 (2017) 42–60
Table 2
Building archetype definition and number of existing dwellings classified, respecting the original codification made by the GTR and exposed in their reports [65,68].
SF housing in rural areas built before Built with traditional solid and thick walls, pitched roof 2,226,973
1960. with a ventilated chamber and ground floor directly in
contact with the ground.
MF buildings over four floors and Built with solid walls, flat roof, suspended slab ground 1,744,016
located in dense urban environments floor, and usually a commercial activity developed on the
and built before 1960. ground floor.
Rural houses built in the period Built with cavity walls, pitched roof without air chamber, 1,864,213
between 1961 and 1980. and outdoor ventilated crawl space under ground floor.
MF dwellings in detached buildings Built with cavity walls, flat roof and outdoor ventilated 4,566,242
either in rural or urban areas, built crawl space under ground floor.
between 1961 and 1980.
SF homes in rural areas built from 1981 Built with cavity walls with integrated thermal insulation, 1,175,785
to 2001, after the introduction of pitched roof without air chamber, outdoor ventilated
Spain’s first mandatory thermal crawl space under ground floor.
regulations.
MF housing located in rural towns and Built with cavity walls with thermal insulation, flat roofs 1,381,041
built between 1981 and 2001. and outdoor ventilated crawl space under ground floor.
MF housing buildings in urban areas Built with solid walls with insulation, flat roofs and 2,400,337
built between 1981 and 2001. outdoor ventilated crawl space under ground floor.
Fig. 2. Flowchart of the research methodology with corresponding section. Adapted from the cost-optimal methodology chart [69] and using official software for EPC in
Spain (CE3x) [62].
lists the outputs of our multi-criteria evaluation, which is con- 4.2. Climatic zones
ducted for each scenario through the developed decision-making
tool described in Section 4.7. Some existing applications of the cost-optimal methodology in
renovation projects, as for example the INSPIRE-Tool developed by
econcept AG for the Swiss context [70], do not take into account
4.1. Housing stock (archetypes) the different climatic zones, making their application restricted to
a specific region in the country. However, we aim to apply our
As seen in Section 2, the analysis of the building stock can be approach to the whole Spanish territory, so it is imperative to take
realised through different approaches, namely reference buildings into account the different climatic zones of Spain, mainly differ-
(corresponding to real building examples) [44], building typolo- entiated according to the winter (WCS) and summer (SCS) climate
gies (corresponding to common buildings) [48], and archetypes severity defined in the current regulation CTE [7,18]. Our proposal
(defined as a theoretical model representing different building is to consider all 12 climatic zones present in the Iberian Peninsula,
typologies) [50]. We propose to use the archetypes approach that represented through the ombrothermic graphs in Fig. 3 according
allows us to scale-up the results from the building to the territorial to the location of the provincial capital [18].
scale.
We have defined our archetypes specifically for energy simula- 4.3. Existing building envelope characteristics of each archetype
tions using, as Parekh [51] recommends, a geometry and envelope
parametrization, defining building typology, construction period To simulate the energy demand of each archetype, defined as a
and climate conditions as the main classification parameters, theoretical model for each typology, and scale-up the results at the
since these three values provide enough guidelines to define the territorial scale, we utilize the shape coefficients listed in Table 3.
archetypes [51,52,68]. These values, taken from a study from the GTR [68] and the master
The categorisation of the residential building stock up to 2001 thesis of the first author [36], correspond to the ratio between the
in Spain has been carried out based on reports from the GTR [64,65] surface of each constructive component – facade, windows, roof
and determining each typology through statistical data [13,14], and ground floor – and the floor area (e.g. m2 of opaque facade/m2
using the frequency of a building type and identifying the most floor area).
relevant ones, as recommended by Schwehr et al. [48]. Finally, we We have obtained the envelope characteristics (U-value) for
managed to classify more than 15 million existing dwellings (Fig. 1) each archetype from the study of the Spanish residential building
in seven archetypes (Table 2). stock carried out by the GTR [68], updating and validating the val-
48 S. Aguacil et al. / Energy and Buildings 144 (2017) 42–60
Fig. 3. Ombrothermic graphs of the 12 climatic zones in Spain (Peninsula). a. Elevation of the main city above sea [m], b. Annual average of Dry Bulb temperature [◦ C], c.
Annual average of rain [l/m2 ], d. Monthly average of rain [l/m2 ], e. Dry Bulb temperature average curve [◦ C], f. Dry Bulb temperature min/max curves [◦ C], g. Relative humidity
average curve [%], h. Relative humidity min/max curves [%] [18].
Table 3
Shape coefficients by archetype [68].
Archetype Shape coefficients by archetype [m2 of component / m2 floor area] Floor area [m2 ] Storey height [m]
ues using the database of the official software (CE3x) for EPC in but also environmental impacts associated with the life of the
Spain [62]. An example for archetype DEF can be found in Table 4. building. Before applying the cost-optimal methodology, we must
be sure that each strategy is technically feasible, according to
the characteristics of the building. This is done by consulting the
4.4. Packages of energy-efficiency measures literature [49,71–73] and defining our different rehabilitation
strategies using the GTR report [65], introduced in Section 3, as a
When considering interventions performed at different basis.
moments in the life of the building, it becomes crucial to simulta-
neously consider mixed solutions (active/passive). This is because
the lifetime of the components is different, e.g. 15 years for a
boiler versus 50 years for thermal insulating elements. Likewise, 4.4.1. Packages of passive improvement strategies
the order of priority in the implementation of different renewal For our purpose of generating a pre-simulated database, we have
strategies (passive or active) is important to achieve a high value chosen two packages of passive strategies, representing two lev-
of long-term savings in terms of energy, GHG emissions, and els of intervention (REF01 and REF02), in addition to the current
cost [10–12,24,41]. First, it is necessary to act on the building status (ORIG), in order to limit the number of combinations to sim-
envelope to reduce the energy demand, and then install active ulate. These represent the options that can then be selected using
systems adapted to the new demand. In this sense, the evaluation our Excel-based decision-making tool, as further detailed in Sec-
of investments takes into account not only economic aspects tion 4.6. An example of the defined packages for archetype DEF,
S. Aguacil et al. / Energy and Buildings 144 (2017) 42–60 49
Table 4
Definition of improvement packages with the resulting envelope characteristics, cost of each strategy and their environmental impact, for a lifetime of 15 years (for LCA).
The values corresponds to archetype DEF (see Table 2) [62,68,74].
Package of strategies Mean U-value after rehabilitation [W/m2 K] for archetype DEF
Table 5
Definition of active improvement strategies through the performance of HVAC system and the type of energy consumed (gas, biomass and electricity-based), cost of each
system and their environmental impact, for a lifetime of 15 years (for LCA) [74].
ORIG: Current system, maintaining the existing gas boiler 70% 57% – –
CALCOND: Changing the existing boiler with a condensing boiler 105% 95% – –
CALBIOM: Changing the existing boiler with a biomass boiler 95% 86% – –
BDC VRV: Implementing a high efficiency electric heat pump 380% 315% 250% 225%
including building envelope features (simulation input data), cost, 4.5. Definition of nearly Zero Energy Buildings (nZEB)
and environmental impact, is presented in Table 4. requirements
Table 6
Percentage reduction in the energy demand when implementing RCALOR strategy (mechanical ventilation system with heat recovery with 1 ach in winter and 5 ach in
summer). Values calculated from own simulations using technical system data from Soler&Palau manufacturer [79].
Climatic zone A3 A4 B3 B4 C1 C2 C3 C4 D1 D2 D3 E1
Heating 18% 14% 21% 20% 29% 27% 23% 21% 31% 30% 28% 33%
Cooling 9% 6% 20% 13% 0% 8% 4% 12% 0% 13% 16% 0%
Table 7
Cost and environmental impacts (for LCA, considering a lifetime of 15 years) of additional strategies [75].
Table 8
Energy efficiency requirements for nZEB standard, according to the German Passivhaus label [79].
ranging between 20 and 200 kWh/m2 per year (of PE consumption) - Primary energy (PE) consumption and related GHG emissions;
and only six of them use the same requirements for both new and - Cumulative cost of energy consumption and saving depending on
existing buildings (20–100 kWh/m2 per year of PE consumption). the horizon of calculation (for LCC);
Spanish regulations are still under development. - Embodied energy and related emissions taking into account
Given this information and following the recommendations of materials and energy use (for LCA).
some publications [10,50], the use of the German Passivhaus label
[79] as a reference to define nZEB requirement is here considered 4.7. Decision-making tool in the excel environment
as a reasonable approach [80]. The target values taken into account
are presented in Table 8. In this section we briefly describe the workflow (Fig. 5) imple-
Trying to go a little further, a reference publication about prin- mented into an Excel-based decision-making tool. The main
ciples for nZEB by the Building Performance Institute Europe (BPIE) objective of this tool is to enable the comparison of different reno-
highlights a lack of implementation of the LCA approach for nZEB vation scenarios in terms of the above-mentioned outputs, through
within the cost-optimal methodology [23]. Hernandez et al. [81] graphical representations of the results. The two main screens of
propose a new-term: life-cycle zero-energy buildings (LC-ZEB), the tool are presented in Figs. 6 and 7.
integrating the embodied energy related to the life cycle of build- As shown in Fig. 4, the tool first needs (1) the definition of
ings. scenarios by the user (in terms of passive, active and RET strate-
In response to this, we propose to implement the Life-Cycle gies) and the type of study desired (scale; for only one versus all
Assessment (LCA) and Life-Cycle Cost (LCC) into the assessment archetype(s) and climatic zone(s)). Users can then, through the (2)
and our Excel-based tool, to have an overview and identify the pos- user-friendly interface (Figs. 6 and 7), define the macroeconomic
sible improvements regarding the renovation strategies proposed, parameters (energy price evolution, interest rate and percentage of
allowing us to check if it is possible to achieve the ambitious EU subsidies) and the calculation horizon (2020, 2030 or 2050). Based
horizon 2050 objectives of 3 kgCO2 /m2 per year (over the whole on this information, the corresponding data is extracted from (3)
life cycle). the tool-integrated database, including the energy demand of each
archetype from the pre-simulated data (see Fig. 6). The data is
4.6. Estimation of energy performance improvements then passed on to (4) a calculation algorithm based on the cost-
optimal methodology (Fig. 2). We obtain the results according to
4.6.1. Calculation horizon the chosen scenario (combination of passive, active and RET strate-
For the economic and energy consumption calculation through- gies – including the moment of implementation) (5a) for a specific
out the life of the building, the following horizons have been archetype and climatic zone if the user has chosen the static cal-
defined: 2020, 2030 and 2050 (short, medium and long term). A culation option. If (5b) the user has chosen the territorial scale
comparison between a reference case (no improvement actions) overview, an automatic iterative process scales-up the individual
and four scenarios with the application of different improvement results to the territorial scale using the statistical data integrated in
strategies are presented. the Excel tool. At each iteration, for a given retrofitting scenario, the
archetype and climatic zone are varied. Finally, this process ends up
storing all results in a double entrance table (archetype vs climatic
4.6.2. Outputs zone, see examples in Section 5.3).
The main outputs from our multi-criteria evaluation are: The tool-integrated database which feeds the calculation algo-
rithm is composed of:
- Global cost, taking into account initial investment, maintenance Census of population and statistical building construction
cost, substitution cost of the current HVAC systems, and energy data: mean surface of each typology and number of homes of each
consumption cost; type for each climatic zone [13,14].
- Net Present Value (NPV) and Payback Period (PBP), using savings Archetype parametrization: based on surface ratios as
as a cash-flow to recover the investment; explained in Section 4.3.
S. Aguacil et al. / Energy and Buildings 144 (2017) 42–60 51
Cost of each retrofit measure: investment cost [74], mainte- the final results, and which are related to the level of detail (LoD) of
nance, substitution, and rate of efficiency loss of HVAC systems over the energy model. In this case, we have modelled our seven theo-
the years [56,82]. retical archetypes (Table 2) based on shape coefficients defined by
Embodied energy and GHG emissions associated to the mate- the surface ratio of each constructive component (Table 5), taking
rials used in each scenario [74]. into account two exposed facades with opposite orientation, and
Pre-simulated energy demand database: as shown in Fig. 6, simulating each model in four orientations to obtain a mean value
the generation of the pre-simulated database starts with (1) the of the energy demand.
archetype parametrization (Section 4.3) and (2) the assignment of
three scenarios for each archetype (Section 4.4). This information is
introduced (3) into the simulation tool environment, currently the 5. Results
CE3x software since we are working at a macro scale. However, for
more accurate simulations, EnergyPlus could be used, as done in In this section, we first present the results from an accuracy test
Section 5.1 to test the accuracy of our results. (4) Finally, we obtain to quantify the error associated to the archetype-based approach
the results in .xml files (from CE3x) and .csv (from EnergyPlus). (5) (using the CE3x tool) compared to dynamically simulating with
These form the database of energy demand for heating, cooling, and EnergyPlus a real building corresponding to the same archetype.
DHW integrated into our Excel tool. The subsequent Sections 5.2 and 5.3 respectively illustrate the types
Obtaining this pre-simulated database involves some simplifi- of studies that can be conducted at the building and territorial
cations and hypotheses that will determine the level of accuracy of scales, including the examples listed in Section 3.
52 S. Aguacil et al. / Energy and Buildings 144 (2017) 42–60
Fig. 6. Decision-making tool – Main window of the LCC – Investment and energy-use for different calculation horizons.
Fig. 7. Decision-making tool – Main window of the LCA – Energy and emissions, including end-use and embodied energy for different calculation horizons.
S. Aguacil et al. / Energy and Buildings 144 (2017) 42–60 53
Table 9 Table 10
Comparison of CE3x and EnergyPlus simulation results. Description of considered scenarios according to the energy-efficiency measures
presented in Section 4.4.
Indicator CE3x EnergyPlus Estimation
error Scenario Passive strategies Active strategies
Heating demand 65.34 kWh/m2 year 55.25 kWh/m2 year +15% S0 ORIG ORIG
Cooling demand 3.64 kWh/m2 year 10.41 kWh/m2 year −35% S1 REF01 ORIG
Mean estimation error: 25% S2 REF02 ORIG
S3 REF01 CALCOND + RCALOR + SOLARACS
S4 REF02 CALCOND + RCALOR + SOLARACS
At a territorial scale, it is not possible to know exactly how is the Table 11a
surrounding environment, particularly to take into account solar Legend and description of considered scenarios according to the energy-efficiency
measures presented in Section 4.4.
obstructions when calculating the level of solar irradiation on each
building surface. Consequently, energy simulations have been run Scenario Passive strategies Active strategies
in different orientations and the average of the results is used. To SC1 ORIG CALCOND
estimate the error caused by assuming this hypothesis, a detailed SC2 ORIG CALBIOM
case study was performed of over 400 dwellings of archetype DEF SC3 ORIG BDC VRV
(4-storey MF buildings) in the urban development of La Roureda – SC4 REF02 RCALOR + SOLARACS
Table 11b
The most cost-effective strategy recommended (for a short-term horizon of calculation). Cells marked with (−) represent cases that are not cost-effective before the calculation
horizon.
Climac Zone
Horizon 2020
A4 A3 B4 B3 C4 C3 C2 C1 D3 D2 D1 E1
A SC1 SC1 SC3 SC1 SC3 SC3 SC1 SC1 SC3 SC3 SC3 SC3
B - - - - SC3 SC1 SC1 SC1 SC3 SC3 SC3 SC3
(see Table 2)
Archetype
C SC1 SC1 SC1 SC1 SC3 SC1 SC1 SC1 SC1 SC3 SC3 SC3
DEF - - - - SC3 SC1 - SC1 SC1 SC3 SC1 SC3
G SC1 - SC1 SC1 SC3 SC1 SC1 SC1 SC1 SC3 SC3 SC3
H - - - SC1 SC3 SC3 SC1 SC1 SC3 SC3 SC3 SC3
IJ - - - - SC3 - - SC1 SC1 SC1 SC1 SC3
Table 11c
The most cost-effective strategy recommended (for a long-term horizon of calculation).
Climac Zone
Horizon 2050
A4 A3 B4 B3 C4 C3 C2 C1 D3 D2 D1 E1
A SC3 SC3 SC3 SC3 SC4 SC4 SC4 SC4 SC4 SC4 SC4 SC4
B SC3 SC3 SC3 SC3 SC4 SC4 SC4 SC4 SC4 SC4 SC4 SC4
(see Table 2)
Archetype
C SC3 SC3 SC3 SC3 SC4 SC4 SC3 SC4 SC4 SC4 SC4 SC4
DEF SC3 SC3 SC3 SC3 SC3 SC4 SC3 SC3 SC4 SC4 SC4 SC4
G SC3 SC3 SC3 SC3 SC3 SC3 SC3 SC3 SC4 SC4 SC4 SC4
H SC3 SC3 SC3 SC3 SC3 SC3 SC3 SC3 SC4 SC4 SC4 SC4
IJ SC3 SC3 SC3 SC3 SC3 SC3 SC3 SC3 SC3 SC3 SC3 SC4
54 S. Aguacil et al. / Energy and Buildings 144 (2017) 42–60
Fig. 9. Cost-optimal chart for DEF archetype in the climatic zone C2-Barcelona, for a 2030 horizon.
5.3. Scaling-up of results at the territorial scale mended strategy is the replacement of old heating systems (active).
However, when the calculation is carried out in the long-term
In this section, five examples of results at the territorial scale are (Table 11c) the recommended strategy is a deep retrofit (passive),
presented. Through the bottom-up approach described in Section acting mainly on the building envelope. Therefore, the results show
4.7 to obtain the results for the whole building stock, a simultaneous that the cost-optimal methodology is a tool that prioritizes deep
overview of the seven building archetypes and 12 climatic zones is retrofitting strategies in less efficient buildings (archetypes A and
provided. B), located in the coldest regions such as D3, D2, D1 and E1 (see
Fig. 3).
5.3.1. Cost-effectiveness between active and passive strategies
In this section, the implementation of an active strategy (acting
on HVAC systems) versus a passive strategy (acting on build- 5.3.2. Relevance of active measures within passive strategies
ing envelope) is compared for a short- and long-term calculation This section presents the comparison between implementing
(Tables 11a–11c), using a 0.5% interest rate, 5% annual rate of different passive strategies (REF01-minor or REF02-deep retrofit)
increased energy costs and four scenarios defined in Table 11a. with or without improving HVAC systems, for a mid-term horizon
Results strongly depend on the horizon of calculation. When the (2030), using a 0.5% interest, 5% annual rate of increased energy
calculation is carried out in the short term (Table 11b), the recom- costs and five renovation scenarios, defined in Table 12a.
S. Aguacil et al. / Energy and Buildings 144 (2017) 42–60 55
Fig. 10. a Life-Cycle Cost (LCC) per dwelling. See Table 10 for description of scenarios. b Life-Cycle Analysis (LCA) per dwelling. See Table 10 for description of scenarios.
Table 12b
The most cost-effective strategy recommended (for a mid-term horizon of calculation). Cells marked with (-) represent cases that are not cost-effective before the calculation
horizon.
Climac Zone
Horizon 2030
A4 A3 B4 B3 C4 C3 C2 C1 D3 D2 D1 E1
A - - - - SC3 SC3 SC2 SC2 SC4 SC4 SC4 SC4
B - - - - SC4 SC2 SC3 SC4 SC4 SC4 SC2 SC4
(see Table 2)
Archetype
Table 13a
Buildings that could reach the level of performance for nZEB, through a deep retrofit REF02 strategy. Cells marked with (-) represent cases that do not achieve the nZEB
targets defined in Section 4.5.
Climac Zone
A4 A3 B4 B3 C4 C3 C2 C1 D3 D2 D1 E1
A nZEB nZEB nZEB nZEB - - - - - - - -
B nZEB nZEB nZEB nZEB - nZEB nZEB nZEB - - - -
(see Table 2)
Archetype
Table 13b
Additional cost per dwelling to increase the facade performance (zones D2, D1, and E1) and improve the ventilation system (zones C1, D3) to achieve nZEB requirements.
Climatic zone Performance level required for the vertical walls Additional cost per dwelling
A4, A3, B4, B3, C4, C3, C2 12 cm of insulation (REF02). U-value: 0.25 W/m2 K –
C1, D3 Heat recovery exchanger for ventilation is recommended 4049 D
D2, D1, E1 18 cm of insulation. U-value: 0.18 W/m2 K 6126 D
Table 14a
Level of public aid [%] required to implement a deep retrofit strategy (REF02) with a payback over 20 years with an interest rate of 0.5%. Cells marked with (–) correspond to
homes that do not need subsidies to recover investment.
2030 A4 A3 B4 B3 C4 C3 C2 C1 D3 D2 D1 E1
Table 14b
Building element surfaces that could be rehabilitated without public aid by 2030 horizon [thousands of m2 ]. Cells marked with (-) are where public subsidies are required to
achieve cost-effectiveness.
5.3.3. Potential in achieving the nZEB target of taxes derived from the generated work could cover these pub-
This section aims at verifying which archetype(s) of existing lic subsidies [58]. The calculation is done in an iterative process,
buildings could become nZEB, by applying a deep retrofit (REF02) increasing the level of subsidies from 0% to 100%, and checking at
and taking into account the different climatic zones (Table 13a). each step if the payback time is over 20 years (for each archetype
As shown in Table 13a, dwellings located in the most extreme and climatic zone, taking into account the current status and the
climatic zones (D1, D2, D3 and E1) do not achieve the level of energy deep retrofit scenario – REF02).
performance required for nZEB. In these zones, it is necessary to As shown in Table 14a, only for the residential buildings built in
increase the level of insulation, the initial investment or public aids, the coldest climatic zones could a deep retrofit strategy (REF02)
as shown in Table 13b listing the additional retrofit and cost needed be applied without subsidies. We can see that the buildings in
to achieve nZEB requirements. warm zones (A4, A3, B4 and B3) need to obtain subsidies to ensure
cost-effectiveness. Table 14b shows the total surface of building
5.3.4. Level of public aid required to implement a deep retrofit elements that could be renovated if all buildings that do not need
strategy public aids implemented the deep retrofit scenario (REF02).
The purpose of this section is to define the total amount of public
aid necessary to make the deep-retrofit strategy (REF02) cost-
effective (Table 14a). This information could help companies in 5.3.5. Payback time estimation for deep retrofit strategy
the construction sector produce business plans focused on energy- This section aims to identify which archetype(s) could be deeply
driven building renovation, while also encouraging the government retrofitted (REF02) with a payback over 7 years (short-term hori-
to assign public aid more efficiently [49], by seeing if the revenue zon) and with or without 25% of public aid.
S. Aguacil et al. / Energy and Buildings 144 (2017) 42–60 57
Table 15
Payback [years], implementing a deep retrofit REF02 with and without 25% of public aid. Values in bold correspond to homes with a payback period equal to or less than 7
years. Values with a star (*) correspond to homes that could have a payback less than 7 years when obtaining 25% of aid. Remaining archetypes always present a payback of
more than 7 years.
2030 A4 A3 B4 B3 C4 C3 C2 C1 D3 D2 D1 E1
Archetype A 17 16 13 13 10 11 9* 9* 8* 8* 9* 7
(see Table 2) B 15 14 11 12 8* 9* 8* 8* 6 6 7 5
C 20 18 15 15 11 13 11 10 9* 9* 10 8*
DEF 17 16 12 13 10 11 9* 9* 8* 8* 9* 7
G 21 19 15 16 12 13 11 11 9* 10 11 8*
H 20 19 14 15 11 12 11 10 8* 9* 10 7
IJ 18 17 13 14 12 12 10 10 9* 9* 10 8*
Table 16
Number of homes it would be advisable to refurbish from 2016 until 2030 on the Spanish territory.
Number of homes to be refurbished (25% of public aid to the investment cost) 9,366,395 homes 61%
Primary energy saving [GWh], from 2016 until 2030 5,906,915 −79.6%
GHG emissions savings [kgCO2 -eq], from 2016 until 2030 1,198,387,749
As shown in Table 15, only dwellings in the coldest climatic The potential housing stock that would achieve the level of
zones (D3, D2, D1 and E1) – in bold – present a payback period requirements of nZEB by implementing a deep-retrofit could reach
(PBP) equal to or less than 7 years. Dwellings in temperate climatic 54.6% (around 9 million homes; Table 13a), but an additional
zones (C4, C3, C2 and C1), corresponding to starred numbers in the investment cost (Table 13b) of about 5000 D per home would be
table, need 25% of public aids to reduce their payback to 7 years. necessary for buildings located in the coldest zones (C1, D1, D2, D3
The remaining dwellings, in the hottest climatic zones (A4, A3, B4 and E1).
and B3), need more than 25% of public aids to reduce their payback According to the results in Table 16, companies in the construc-
to 7 years. tion sector should concentrate, firstly, on homes situated in the
coldest zones, such as E1-Leon, D1-Lugo, C4-Cáceres, C3-Granada
6. Discussion and D2-Huesca. Indeed, in these regions, it is cost-effective to pro-
pose a deep-retrofit strategy without considering public aid.
If the horizon of calculation is in the mid- to long-term, the cost-
optimal methodology prioritizes passive strategies on the building
envelope, allowing an important reduction in energy demand 7. Conclusions and recommendations
(Tables 11a–11c). Therefore, work on the envelope of the build-
ings is a priority to achieve the objectives established by the EU to The literature review suggests that the cost-optimal methodol-
reduce energy consumption of the built environment. ogy can perfectly be used to compare different renovation scenarios
The cost-optimal methodology is designed for mid- and long- to make strategic decisions assuming an error up to 30%, due to
term investment scenarios, which is why, in the short-term studies, uncertainties in input data, working at the urban scale and without
the most cost-effective strategies are always related to improving taking into account different climatic zones [70].
the efficiency of HVAC systems (Tables 12a and 12b). However, by Therefore, the purpose of this study was to investigate if the
using only active strategies, a maximum of about 40% energy sav- cost-optimal methodology could successfully be applied at the ter-
ings can be expected, while up to 80% can be achieved by combining ritorial scale – based on the extrapolation of results from building
passive and active strategies. and neighbourhood scales using more accurate input data than typ-
During the period of 2004–2013, the average annual increase in ically used – to obtain an overview of the status of existing buildings
the price of energy in Spain has been between 6.5% and 10.9% (with- and their potential energy and GHG emissions savings.
out considering associated taxes) [82]. The methodology is very This is accomplished by implementing a new systematic strat-
sensitive to this parameter. In fact, if the annual energy cost increase egy, starting from the categorization of the existing housing stock
exceeds 10%, a deep-retrofit strategy becomes the preferred option, based on the climatic zone and the period of construction, using
also in the short-term. statistical data and linking this information at different scales −
If the interest rate is very high, the most disadvantaged strat- city and building – through energy simulations based on different
egy is deep-retrofit due to the higher initial investment. Offering levels of detail and their extrapolation to the territorial scale.
credits with a lower interest rate of 5% could therefore potentially This research provides empirical evidence that the most
encourage this type of strategy. This is the case in most EU coun- effective levers to manage the renewal processes of the built envi-
tries today. Since 2008, probably due to the economic crisis, the ronment to achieve the targets of the EU energy directives are
interest rate of EURIBOR [83] has remained around 0.5%. Therefore, passive strategies acting on buildings’ envelopes. Such strategies
the context is ideal for promoting energy rehabilitation projects of could give significant benefits including higher levels of energy
existing buildings [84]. savings (about 40%), while increasing interior comfort, quality and
As a result of the studies realised with the help of the decision- value of buildings. It is essential to highlight that to achieve about
making tool, if the target is to rehabilitate about 100% of existing 80% savings, it is necessary to consider improvement packages
homes (built between 1960 and 2001) from 2016 until 2030 and where passive and active strategies are contemplated at the same
following a deep-retrofit strategy, the Spanish government would time, paying special attention to the order of priority in which they
have to invest about 29,286 MD (1464 MD /year). are implemented.
58 S. Aguacil et al. / Energy and Buildings 144 (2017) 42–60
The results of this study also indicate that the definition of the National Science Foundation (SNSF) for their financial support to
horizon of calculation, the macroeconomic parameters, the urban the ACTIVE INTERFACES research project, which represents a con-
environment and the climatic zone conditions are critical to achieve tinuation of certain reflexions undertaken within the framework of
an accurate level of results and may significantly contribute to this study.
progress toward increasing the level of sustainability of the resi-
dential building stock of tomorrow. References
Taking into account the actual macroeconomic situation in
Spain, using a reasonable scenario with 25% of public aid to the [1] Comision Europea, Energía, 2014, http://dx.doi.org/10.2775/60262.
investment cost of the renovation and an interest rate of 0.5%, the [2] Idae, Plan de ahorro y eficiencia energética 2011–20 (Spanish National
Renewable Energy Plan (NREP) 2011–2020), (2011) 268. http://www.idae.es/
potential housing stock that would achieve the level of require- uploads/documentos/documentos 11905 PAEE 2011 2020. A2011 A
ments of nZEB by implementing a deep-retrofit could reach 61% a1e6383b.pdf.
(around 9 million dwellings) with 79.6% of PE (5,906,915 GWh) and [3] European Commission, Hoja de Ruta de la Energía para 2050, COM(2011) 885
Final. (2011) 23. http://eur-lex.europa.eu/LexUriServ/LexUriServ.
CO2 emissions (1,198,388 tCO2 ) savings. do?uri=COM:2011:0885:FIN:ES:PDF.
Our proposed approach, implemented into an Excel-based [4] Suisse Energie, La société à 2000 watts, (2016). http://www.2000watt.ch/fr/
decision-making tool relying on (and extending) the cost-optimal (Accessed 20 January 2016).
[5] SFOE, Energy Strategy 2050, 2015, http://www.bfe.admin.ch/themen/00526/
methodology, can support urban planners make strategic decisions 00527/index.html?lang=en (Accessed 22 September 2015).
towards more sustainable urban renewal processes of the build- [6] H. Akbari, M. Santamouris, Z. Ma, P. Cooper, D. Daly, L. Ledo, Existing building
ing stock. It can moreover help the construction sector adapt their retrofits: methodology and state-of-the-art, Energy Build. 55 (2012) 889–902
(http://www.sciencedirect.com/science/article/pii/S0378778812004227
business goals to promote energy renewal projects.
(Accessed 17 December 2013).
Derived from the main results of this study, a list of recommen- [7] M. Gangolells, M. Casals, N. Forcada, M. Macarulla, E. Cuerva, Energy mapping
dations to encourage owners to undertake a renovation of their of existing building stock in Spain, J. Clean. Prod. 112 (2016) 3895–3904,
http://dx.doi.org/10.1016/j.jclepro.2015.05.105.
building is proposed:
[8] A. Brandão de Vasconcelos, M.D. Pinheiro, A. Manso, A. Cabaço, EPBD
cost-optimal methodology: application to the thermal rehabilitation of the
building envelope of a Portuguese residential reference building, Energy
- Public aid to subsidize the initial investment;
Build. 111 (2015) 12–25 (under review).
- More attractive credits to implement passive strategies; [9] IEA, Energy Performance Certification of Buildings – A Policy Tool to Improve
- Increase in value-added tax (VAT) on less efficient HVAC systems; Energy Efficiency, 2010, pp. 64 http://www.iea.org/publications/
- Reduction in VAT, to promote the use of more ecological certified freepublications/publication/buildings certification.pdf.
[10] IEA, Transition to Sustainable Buildings, 2013, http://dx.doi.org/10.1787/
products; 9789264202955-en.
- Campaign to promote the rehabilitation of buildings, lowering the [11] A. Uihlein, P. Eder, Policy options towards an energy efficient residential
Property Tax (IBI) during the years in which investment is being building stock in the EU-27, Energy Build. 42 (2010) 791–798, http://dx.doi.
org/10.1016/j.enbuild.2009.11.016.
recovered; [12] E. Stocker, M. Tschurtschenthaler, L. Schrott, Cost-optimal renovation and
- Promote energy rehabilitation of entire buildings, offering com- energy performance: evidence from existing school buildings in the Alps,
munities city-funded advice and management. The owners would Energy Build. 100 (2015) 20–26, http://dx.doi.org/10.1016/j.enbuild.2015.04.
005.
only have to pay a fee to the city council, equivalent to the [13] Instituto Nacional de Estadistica, 2001 Population and Housing Census, 2001
monthly savings of the overall energy bill. The preliminary study http://www.ine.es/.
would be to calculate the monthly fee that a community could [14] Instituto Nacional de Estadistica, 2011 Population and Housing Census, 2011
http://www.ine.es/jaxi/Tabla.htm?path=/t20/e244/edificios/p02/l0/.px.
pay, based on energy savings achieved after rehabilitation. There-
[15] M. Gangolells, M. Casals, Resilience to increasing temperatures: residential
fore, they would know whether they can pay the investment building stock adaptation through codes and standards, Build. Res. Inf. 40
through a soft loan; if not, the administration should finance the (2012) 1–20, http://dx.doi.org/10.1080/09613218.2012.698069.
[16] BPIE (Building Performance Institute Europe), Nearly Zero Energy Buildings
rest.
Definitions Across Europe, 2015, pp. 8 http://bpie.eu/uploads/lib/document/
attachment/132/BPIE factsheet nZEB definitions across Europe.pdf.
Future development of this research will look into incorporating [17] European Parliament, Directive 2010/31/EU of the European Parliament and
of the Council of 19 May 2010 on the energy performance of buildings EPBD
more case studies at the neighbourhood and building scales, using (recast), Off. J. Eur. Union. (2010) 153, http://dx.doi.org/10.3000/17252555.
accurate energy simulation and involving more building-typology [18] Spanish building regulation, Documento básico HE ahorro de energía, Código
diversity, with the aim to better calibrate the decision-making Técnico La Edif. Doc. Básico HE Ahorr. Energía. 2013 (2013) 1–70. http://www.
codigotecnico.org/web/recursos/documentos/.
tool for territorial-scale applications. Implementing the calcula- [19] MINETUR, Current state of the energy certification of buildings. Data from
tion algorithm into a geographic information system (GIS) platform regional governments (Estado de la certificaci on energ etica de los edificios.
could be envisioned mainly for enhanced visualization. Datos CCAA), 2015 http://www.minetur.gob.es/energia/desarrollo/
EficienciaEnergetica/CertificacionEnergetica/Documentos/Documents/
To further refine our building stock database, satellite-derived Informe-seguimiento-certificacion-energetica-V2.pdf.
data could be used. Along the same line of thought, optimization [20] Spanish government, Real Decreto 235/2013, de 5 de abril, por el que se
methods could be employed to better identify cost-optimal strate- aprueba el procedimiento básico para la certificación de la eficiencia
energética. (2013) 1–14.
gies [32]. [21] IDAE, Energy Performance Rating for Existing Buildings (Escala de calificaci on
The inclusion of Building-Integrated Photovoltaic (BIPV) into the energetica para edificios existentes), 2011 http://www.minetur.gob.es/
renewable energy strategies is also planned, in order to achieve energia/desarrollo/EficienciaEnergetica/CertificacionEnergetica/
DocumentosReconocidos/OtrosDocumentos/
Low-Carbon horizon targets in EU countries [85].
Calificaci%C3%B3n%20energ%C3%A9tica.%20Viviendas/Escala Calif%20
Finally, in terms of economic outputs, it would be advisable to Edif%20 Existentes accesible.pdf.
calculate the government incomes due to the VAT (e.g. through [22] BPIE (Building Performance Institute Europe), Europe’s Buildings Under the
increased retrofit-related work), which could be superior to the Microscope. A Country-by-Country Review of the Energy Performance of
Buildings, 2011.
total amount of public aids to the dwelling owners, as demonstrated [23] BPIE (Building Performance Institute Europe), Principles for Nearly
in [58]. Zero-Energy Buildings, Paving the Way for Effective Implementation of Policy
Requirements, 2011 http://www.bpie.eu/nearly zero.html.
[24] G. Dall’O’, A. Galante, G. Pasetti, A methodology for evaluating the potential
Acknowledgements energy savings of retrofitting residential building stocks, Sustain. Cities Soc. 4
(2012) 12–21, http://dx.doi.org/10.1016/j.scs.2012.01.004.
[25] Spanish government, Real Decreto 2429/79 – Norma Basica de la Edificacion
The authors would like to express their gratitude to the National NBE-CT-79, sobre Condiciones Térmicas en los edificios, 1979, pp. 27 https://
Research Programme “Energy Turnaround” (NRP 70) of the Swiss www.boe.es/buscar/doc.php?id=BOE-A-1979-24866.
S. Aguacil et al. / Energy and Buildings 144 (2017) 42–60 59
[26] Ministerio de vivienda, REAL DECRETO 314/2006, de 17 de marzo, por el que [51] A. Parekh, Development of archetypes of building characteristics libraries for
se aprueba el Código Técnico de la Edifi- cación, Real Decreto, 2006, pp. simplified energy use evaluation of houses, Ninth Int. IBPSA Conf. (2005)
11816–11831 http://www.codigotecnico.org/web/recursos/documentos/. 921–928 http://www.ibpsa.org/?page id=113.
[27] Spanish government, RITE. Reglamento de instalaciones térmicas en los [52] L.G. Swan, V.I. Ugursal, Modeling of end-use energy consumption in the
edificios, Bol. Of. Del Estado (2007) 35931–35984. residential sector: a review of modeling techniques, Renew. Sustain. Energy
[28] Spanish government, REAL DECRETO 47/2007, Bol. Of. Del Estado. 27 (2007) Rev. 13 (2009) 1819–1835, http://dx.doi.org/10.1016/j.rser.2008.09.033.
4499–4507. [53] F. Ascione, N. Bianco, C. De Stasio, G.M. Mauro, G.P. Vanoli, A new
[29] Spanish government, Ley de Rehabilitación, Regeneración y Renovación methodology for cost-optimal analysis by means of the multi-objective
Urbana, 2013, pp. 47964–48023. optimization of building energy performance, Energy Build. 88 (2015) 78–90,
[30] J.S. Bourrelle, I. Andresen, A. Gustavsen, Energy payback: an attributional and http://dx.doi.org/10.1016/j.enbuild.2014.11.058.
environmentally focused approach to energy balance in net zero energy [54] P. Aparicio, J. Guadix, J. Salmerón, F.J. Sánchez, An integrated optimisation
buildings, Energy Build. 65 (2013) 84–92, http://dx.doi.org/10.1016/j.enbuild. method for residential building design. A case study in Spain, Energy Build. 80
2013.05.038. (2014) 158–168, http://dx.doi.org/10.1016/j.enbuild.2014.05.020.
[31] E. Pikas, M. Thalfeldt, J. Kurnitski, Cost optimal and nearly zero energy [55] E. Asadi, M.G. da Silva, C.H. Antunes, L. Dias, A multi-objective optimization
building solutions for office buildings, Energy Build. 74 (2014) 30–42, http:// model for building retrofit strategies using TRNSYS simulations, GenOpt and
dx.doi.org/10.1016/j.enbuild.2014.01.039. MATLAB, Build. Environ. 56 (2012) 370–378, http://dx.doi.org/10.1016/j.
[32] O. Pombo, K. Allacker, B. Rivela, J. Neila, Sustainability assessment of energy buildenv.2012.04.005.
saving measures: a multi-criteria approach for residential buildings [56] S. Attia, M. Hamdy, W. O’Brien, S. Carlucci, Assessing gaps and needs for
retrofitting-A case study of the Spanish housing stock, Energy Build. 116 integrating building performance optimization tools in net zero energy
(March (15)) (2016) 384–394, http://dx.doi.org/10.1016/j.enbuild.2016.01. buildings design, Energy Build. 60 (2013) 110–124, http://dx.doi.org/10.1016/
019. j.enbuild.2013.01.016.
[33] I. Zacà, D. D’Agostino, P.M. Congedo, C. Baglivo, Assessment of cost-optimality [57] S.H. Lee, T. Hong, M.A. Piette, Review of Existing Energy Retrofit Tools,
and technical solutions in high performance multi-residential buildings in the Lawrence Berkeley National Laboratory, 2014 https://buildings.lbl.gov/sites/
Mediterranean area, Energy Build. 102 (2015) 250–265, http://dx.doi.org/10. all/files/tianzhen hong - review of existing energy retrofit tools.pdf.
1016/j.enbuild.2015.04.03. [58] P. Bermejo, El «renove de casas», La Razon. (2014) 44–45.
[34] European Parliament, Directive 2012/27/EU of the European Parliament and [59] P.a. Fokaides, A.M. Papadopoulos, Cost-optimal insulation thickness in dry
of the Council of 25 October 2012 on energy efficiency, Off. J. Eur. Union and mesothermal climates: existing models and their improvement, Energy
(2012) 1–56, http://dx.doi.org/10.3000/19770677.L 2012.315.eng. Build. 68 (2014) 203–212, http://dx.doi.org/10.1016/j.enbuild.2013.09.006.
[35] BPIE (Building Performance Institute Europe), Implementing the Cost-Optimal [60] P. Steskens, Y. Vanhellemont, S. Roels, N. Van Den Bossche, A decision making
Methodology in EU Countries: Lessons Learned from Three Case Studies, 2013. tool for the energy efficient refurbishment of residential buildings, Energy
[36] S. Aguacil, Evaluation of the Cost-Optimal Methodology for Energy Procedia 0 (2015) 997–1002, http://dx.doi.org/10.1016/j.egypro.2015.11.043.
Rehabilitation of Buildings and Objective Assessment NZEB (Nearly Zero [61] T. Ashrafian, A.Z. Yilmaz, S.P. Corgnati, N. Moazzen, Methodology to define
Energy Buildings), Universitat Politecnica de Catalunya, 2013 http://hdl. cost-optimal level of architectural measures for energy efficient retrofits of
handle.net/2099.1/20487. existing detached residential buildings in Turkey, Energy Build. 120 (2016)
[37] A. Brandão de Vasconcelos, M.D. Pinheiro, A. Manso, A. Cabaço, A Portuguese 58–77, http://dx.doi.org/10.1016/j.enbuild.2016.03.074.
approach to define reference buildings for cost-optimal methodologies, Appl. [62] EFINOVATIC., CE3x, (2016). http://www.efinovatic.es/.
Energy 140 (2015) 316–328, http://dx.doi.org/10.1016/j.apenergy.2014.11. [63] GBCe, Fundacion CONAMA, Rehabilitation Working Group (GTR), (2016).
035. http://www.gbce.es/en/pagina/gtr-goals-and-targets (Accessed 19 January
[38] P.M. Congedo, C. Baglivo, D. D’Agostino, I. Zacà, Cost-optimal design for nearly 2016).
zero energy office buildings located in warm climates, Energy 91 (2015) [64] A. Cuchí, P. Sweatman, GTR Report 2011: A National Perspective on Spain’s
967–982, http://dx.doi.org/10.1016/j.energy.2015.08.078. Buildings Sector. A Roadmap for a New Housing Sector, 2011.
[39] I. Kovacic, M. Summer, C. Achammer, Strategies of building stock renovation [65] A. Cuchí, P. Sweatman, GTR Report 2012: A National Perspective on Spain’s
for ageing society, J. Clean. Prod. 88 (2015) 349–357, http://dx.doi.org/10. Building Sector. Action Plan for a New Housing Sector, 2012.
1016/j.jclepro.2014.04.080. [66] A. Cuchí, P. Sweatman, GTR Report 2014: Strategy for Buildings Renovation
[40] V. Corrado, I. Ballarini, S. Paduos, Assessment of cost-optimal energy Keys to Transform Spain’s Building Sector, 2014.
performance requirements for the Italian residential building stock, Energy [67] European Commission, EUROSTAT, Prod. Constr. down by 0.4% Euro Area,
Procedia 45 (2014) 443–452, http://dx.doi.org/10.1016/j.egypro.2014.01.048. 2015, http://ec.europa.eu/eurostat/en/web/products-press-releases/-/4-
[41] S. Domingo-Irigoyen, A. Sánchez-Ostiz, J.S. Miguel-Bellod, Cost-effective 18112015-AP (Accessed 18 January 2016).
renovation of a multi-residential building in Spain through the application of [68] A. Cuchí, P. Sweatman, A. Pagès, Scenarios for the Reduction of Greenhouse
the IEA annex 56 methodology, Energy Procedia 78 (2015) 2385–2390, http:// Gas (GHG) Emissions for the Residential Sector in Spain, 2012.
dx.doi.org/10.1016/j.egypro.2015.11.194. [69] A. Enseling, T. Loga, Implementing the Cost-Optimal Methodology in EU
[42] L. Aelenei, S. Paduos, H. Petran, J. Tarrés, A. Ferreira, V. Corrado, et al., Countries – Case Study Germany, 2012.
Implementing cost-optimal methodology in existing public buildings, in: [70] M. Jakob, Marginal costs and co-benefits of energy efficiency investments: the
Energy Procedia, Elsevier B.V., 2015, pp. 2022–2027, http://dx.doi.org/10. case of the Swiss residential sector, Energy Policy 34 (2) (2006) 172–187,
1016/j.egypro.2015.11.197. http://dx.doi.org/10.1016/j.enpol.2004.08.039.
[43] E.G. Dascalaki, K.G. Droutsa, C.A. Balaras, S. Kontoyiannidis, Building [71] M. Kapsalaki, V. Leal, M. Santamouris, A methodology for economic efficient
typologies as a tool for assessing the energy performance of residential design of Net Zero Energy Buildings, Energy Build. 55 (2012) 765–778, http://
buildings – a case study for the Hellenic building stock, Energy Build. 43 dx.doi.org/10.1016/j.enbuild.2012.10.022.
(2011) 3400–3409, http://dx.doi.org/10.1016/j.enbuild.2011.09.002. [72] J. Kurnitski, How to calculate cost optimal nZEB energy performance? REHVA
[44] I. Ballarini, S.P. Corgnati, V. Corrado, Use of reference buildings to assess the J. (2011) 36–41.
energy saving potentials of the residential building stock: the experience of [73] F. Flourentzou, C.-A. Roulet, Elaboration of retrofit scenarios, Energy Build. 34
TABLE project, Energy Policy 68 (2014) 273–284, http://dx.doi.org/10.1016/j. (2002) 185–192 (Accessed 17 December 2013) http://www.sciencedirect.
enpol.2014.01.027. com/science/article/pii/S0378778801001062.
[45] Intelligent Energy Europe, Typology Approach for Building Stock Energy [74] CYPE Ingenieross, Database of Construction Products and Systems (CYPE
Assessment – TABLE Database (National Building Typology), 2016, http:// Ingenieros), 2016 (Accessed 18 October 2016) http://www.
episcope.eu/building-typology/ (Accessed 14 November 2016). generadordeprecios.info/.
[46] K. Fabbri, L. Tronchin, V. Tarabusi, Energy retrofit and economic evaluation [75] COP – Coefficient of performance. https://en.wikipedia.org/wiki/Coefficient
priorities applied at an italian case study, Energy Procedia 45 (2014) 379–384, of performance (2016) (Accessed 10 November 2016).
http://dx.doi.org/10.1016/j.egypro.2014.01.041. [76] SEER – Seasonal energy efficiency ratio. https://en.wikipedia.org/wiki/
[47] E. Pikas, J. Kurnitski, R. Liias, M. Thalfeldt, Quantification of economic benefits Seasonal energy efficiency ratio (2016) (Accessed 11 October 2016).
of renovation of apartment buildings as a basis for cost optimal 2030 energy [77] E. Rey, S. Lufkin, C. Ballif, R. Wuestenhagen, S. Wittkopf, J.-P. Bacher, Building
efficiency strategies, Energy Build. 86 (2015) 151–160, http://dx.doi.org/10. integrated photovoltaics | ACTIVE INTERFACES, National Research
1016/j.enbuild.2014.10.004. Programmes NRP 70 «Energy Turnaround» and NRP 71 «Managing Energy
[48] P. (Lucerne U. of A.S. and A. (Hslu)) Schwehr, R. (Lucerne U. of A.S. and A.-C. Consumption», Luzern (2015).
Fischer, Building Typology and Morphology of Swiss Multi-Family Homes [78] D. D’Agostino, Assessment of the progress towards the establishment of
1919–1990, (2010) p.11. definitions of Nearly Zero Energy Buildings (nZEBs) in European Member
[49] eceee, Cost optimal building performance requirements: Calculation States, J. Build. Eng. 1 (2015) 20–32, http://dx.doi.org/10.1016/j.jobe.2015.01.
methodology for reporting on national energy performance requirements on 002.
the basis of cost optimality withing the framework of the EPBD, Stockholm, [79] Passive House Institute, (2016) http://www.passivehouse.com/ (Accessed 8
Sweden (2011). www.eceee.org. November 2016).
[50] M.J.N. Oliveira Panão, M.P. Rebelo, S.M.L. Camelo, How low should be the [80] Comunidad de Madrid, Guia del estándar PassivHaus; edificios de consumo
energy required by a nearly Zero-Energy Building? The load/generation energético casi nulo, (2011) 203.
energy balance of Mediterranean housing, Energy Build. 61 (2013) 161–171, [81] P. Hernandez, P. Kenny, From net energy to zero energy buildings: defining
http://dx.doi.org/10.1016/j.enbuild.2013.02.031. life cycle zero energy buildings (LC-ZEB), Energy Build. 42 (2010) 815–821,
http://dx.doi.org/10.1016/j.enbuild.2009.12.001.
60 S. Aguacil et al. / Energy and Buildings 144 (2017) 42–60
[82] National Energy Commission, Monthly Bulletin of Electrical and Economic [85] S. Aguacil, S. Lufkin, E. Rey, Towards integrated design strategies for
Indicators (2013–2016), 2016 https://www.cnmc.es/es-es/energ%C3%ADa/ implementing BIPV systems into urban renewal precesses: first case study in
energ%C3%ADael%C3%A9ctrica/indicadoresel%C3%A9ctricos.aspx. Neuchâtel (Switzerland), in: G. Habert, A. Schlueter (Eds.), Sustain. Built
[83] Triami Media, Euribor-rates, (2016). http://www.euribor-rates.eu (Accessed Environ. 2016, Reg. Conf. Zurich, Zurich, 2016, pp. 234–239, http://dx.doi.org/
11 October 2016). 10.3218/3774-6.
[84] I.U. The Economist, Investing in Energy Efficiency in Europe ’s Buildings – A
View from the Construction and Real Estate Sectors, Econ. Intell. Unites Ltd.,
2013, pp. 1–17.