Reflector
Base plastic Diffusor
‘’ EASY LEDs LIGHT ‘’ SERIES FOR
B GR-312/LS MAINTAINED / NON-MAINTAINED (OPTIONAL) LUMINAIRE
B TECHNICAL CHARACTERISTICS
A
OPERATION VOLTAGE 220-240V AC/50-60Hz
MAXIMUM POWER CONSUMPTION 3W / 3.5VA
BATTERY (Ni-Cd) 3.6V/1Ah
A BATTERY PROTECTION From overcharge and full discharge
INDICATIONS - CONTROLS Battery charge indication LED, TEST button
4 5 6 CHARGING TIME 24 h
Cable entry channels L MINIMUM AUTONOMOUS DURATION 180 min
ILLUMINATION SOURCE White LED’s
Luminaire mounting holes
ILLUMINATION (MAINS / EMERGENCY) 35lm / 85lm
DEGREES OF COVER PROTECTION IP 40
PRODUCED IN ACCORDANCE WITH EN 60598-1, EN 60598-2-22, ÅÍ 55015, ÅÍ 61547, ÅÍ 61000-3-2, ÅÍ 61000-3-3
OPERATION TEMPERATURE RANGE 0 to 40 o C
Base plastic RELATIVE HUMIDITY Up to 95%
CONSTRUCTION MATERIALS Bayblend FR3010, transparent polycarbonate
N 350 x 134 x 45 mm (CRV 362 x 134 x 58 mm)
EXTERNAL DIMENSIONS
TYPICAL WEIGHT 680gr.
1 To install the luminaire you must dismantle it to 3 parts. GUARANTEE 3 years (1 year for the battery)
2 Place a flat blade screwdriver in the area Á to release the diffusor’s plastic hook.
3 Place a flat blade screwdriver in the area B to release the reflector’s plastic hook. GENERAL pushing the TEST button to check the
4 Use the included mounting parts to mount the base plastic. These luminaires are used in places where emergency circuit. The led strip should: a) light
Pass the mains cable thru a cable entry channel. emergency luminaires are needed. with bigger intensity as long as the TEST button
Each luminaire must be permanently connected is pressed (maintained operation),
5 Place the battery’s connector to the corresponding connector on the P.C.B.
to mains power supply. b) light as long as the TEST button is pressed
6 Connect the mains cables to the terminal blocks. In normal operation the led strip lights and the (non-maintained operation). If the luminaire
7 Refit the removed parts in steps 2 and 3 (mind the correct orientation) and the luminaire battery is charging. doesn’t work as described above contact the
is ready to operate. In case of a mains power supply failure the installer.
NOTE!! After finishing the installation you must power the device at least for 24 hours for battery luminaire will light the led strip automatically in
charging to perform the named autonomy. emergency mode. When the mains power 4. It is sugested to check every 6 months the
8. MAINTAINED/NON-MAINTAINED OPERATION supply is restored the device turns to normal minimum autononous duration by disconnecting
JUMPER SELECTION operation. the mains power supply. Count the time that the
You can choose the lumminare’s operation. When the led strip lights and in case of less time than the
jumper is installed (by default) on the middle and right M A I N TA I N E D / N O N - M A I N TA I N E D minimum autonomous duration the battery must
pins you select maintained operation. When the OPERATION be replaced. If the measured time is
jumper is installed on the middle and left pins you There is an option to select the maintained or considerably less than the minimum autonomous
select non-maintained operation. non-maintained operation by placing the jumper duration contact the installer. In case of battery
to the appropriate place according to step 8 or led strip replacement, these must be replaced
(page 2). by parts of the same type, by the manufacturer
NOTE: LED= Light Emitting Diode or by a competent person.
INSTALLATION
LABELING EXPLANATION: To install the luminaire follow the installation 5. In case of inactive use for a period greater
X: Self contained instructions ïn page 4. than 2 months, disconnect the battery by pulling
1: Maintained (*) Maintained Non-maintained out the battery’s connector.
A: Including test device ÁÔÔÅÍÔÉÏÍ!!!
operation operation
180: 3 hour duration 1. Operations for installation, maintainance or 6. It is not allowed to discard batteries in to
testing must be done by authorized personel common trash bins, they must be discarded
All the types of Easy Light series, are also produced only. only in battery recycling points. Do not
with a new designed crystal with GR-XXX/CRV code, incinerate.
for example GR-312/LS /CRV. 2. The device must be connected to the mains
(*) Maintained operation: The luminaire lights its illumination source, when it is powered by the mains power supply thru a fuse dependent by the total
power supply or not. amount of the line’s power load.
Non-Maintained operation: The luminaire lights its illumination source, only in power supply’s failure.
3. It is sugested to check every month the
indication LED for battery charging, and by
A-3018