You are on page 1of 2

1 2 3 4 5 6 7 8

PE L1 L2 L3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55

E E

ACTUATOR
CM + CM + + + + +
- +
M

CLOSE

OPEN
STOP
REM
ESD

ESD

IL1

IL2
M1 R1 R2 R3 R4 CS MONIT. REMOTE

K0000300X
LEGENDS:
D D
M1 ELECTRIC MOTOR ACTS AUXILIARY CLOSE TORQUE SWITCH CTS CLOSE TORQUE SWITCH
PLUG-AND-SOCKET CONNECTOR LAYOUT R1 RELAY OUTPUT No1 (SETTABLE) AOTS AUXILIARY OPEN TORQUE SWITCH OTS OPEN TORQUE SWITCH
R2 RELAY OUTPUT No2 (SETTABLE) ACLS AUXILIARY CLOSE LIMIT SWITCH CLS CLOSE LIMIT SWITCH
R3 RELAY OUTPUT No3 (SETTABLE) AOLS AUXILIARY OPEN LIMIT SWITCH OLS OPEN LIMIT SWITCH
R4 RELAY OUTPUT No4 (SETTABLE) IP1 VALVE MIDDLE TRAVEL POSITION SWITCH (No 1) TRM THERMAL PROTECTION DEVICE
R5 IP2 VALVE MIDDLE TRAVEL POSITION SWITCH (No 2) (MOTOR WIND.)
RELAY OUTPUT No5 (SETTABLE)
41 40 39
42 R6 RELAY OUTPUT No6 (SETTABLE) IP3 VALVE MIDDLE TRAVEL POSITION SWITCH (No 3) HT ANTI-CONDENSATION HEATER
C 19 18 17 38 R7 RELAY OUTPUT No7 (SETTABLE) IP4 VALVE MIDDLE TRAVEL POSITION SWITCH (No 4) BLK BLINKER SWITCH C
43 20 16
37 R8 RELAY OUTPUT No8 (SETTABLE) CPT CURRENT POSITION TRANSMITTER POT POTENTIOMETER (VALVE
21 09 15 POSITION SIGNAL)
44 08 R9 RELAY OUTPUT No9 (SETTABLE) CTT CURRENT TORQUE TRANSMITTER

45
22
10
3 2 07 14 36 R10 RELAY OUTPUT No10 (SETTABLE) CPT.LP CURRENT POSITION TRANSMITTER,
LOOP POWER
CPT CURRENT POSITION TRANSMITTER
(VALVE POSITION SIGNAL)
23 13 35 R11 RELAY OUTPUT No11 (SETTABLE)
DSM DIGITAL SWITCH MECHANISM
R12 RELAY OUTPUT No12 (SETTABLE) CTT.LP CURRENT TORQUE TRANSMITTER,
46 24 (ELECTRONIC VALVE POSITION
12 CS CUSTOMER SUPPLY LOOP POWER
34 AND TORQUE SIGNALS)
11 06 BS BACKUP SUPPLY
B 47 25 1 33
55 POSITIONER POSITIONER IN/OUT
NOTES:
1. THE TERMINAL PLAN SHOWS THE MULTI-TURN ELECTRIC ACTUATOR IN INTERMEDIATE
B
04 05
26 32 ANALOG SIGNAL POSITION, ACTUATOR CLOSES VALVE CLOCKWISE.
48
27 31 54 POSITIONER.LP POSITIONER IN/OUT 2. SEE ACTUATOR USER MANUAL AND DATASHEETS FOR TECHNICAL DATA, PARAMETERS
49 28 29 30 ANALOG SIGNAL. AND DESCRIPTION OF THE ACTUATOR ELECTRIC AND ELECTRONIC EQUIPMENT.
53
50 LOOP POWER 3. IF THE ACTUATOR IS CONFIGURED TO BYPASS THE MOTOR PROTECTION THERMOSTAT (TRM),
51 52
MONIT. MONITOR RELAY THE ACTUATOR WILL NO LONGER COMPLY WITH THE ESSENTIAL SAFETY REQUIREMENTS.
FIELDBUS FIELDBUS CARD 4. THE USER MUST FIT A CLASS 10 OVERLOAD RELAY. THE RELAY MUST BE SIZED ACCORDING
TO THE OVERCURRENT PROT. DEVICE SETTING VALUE FOR THE MOTOR.
REMOTE REMOTE INPUT CARDS
5. REFER TO THE MOTOR DATA SHEET FOR THIS VALUE. THE OVERLOAD RELAY
A MUST BE SIZED TO ENSURE THAT IT TRIPS WITHIN 10 SECONDS IN A FAULT CONDITION. A
PARAMETER VALUE DESCRIPTION 6. THE USER MUST COMPLETE A RISK ASSESSMENT AND IMPLEMENT WHATEVER MEASURES ARE
TYPE K MULTI-TURN ELECTRIC ACTUATOR, WITH CENTRONIK (DIGITAL SWITCH MECH.)
REQUIRED TO ENSURE THAT THE RESULTANT SYSTEM COMPLIES WITH ALL APPLICABLE LEGISLATION.
MAIN POWER SUPPLY ISSUE DATE ISSUE DATE
0 A.C. THREE PHASE
1 FIRST RELEASE 17-12-15 3 - -
EXTRA CARD No 1 0 NO (WITHOUT)
2 REDRAWN IN SOLID EDGE 15-06-16 4 - -
EXTRA CARD No2 0 NO (WITHOUT)
MOTOR STARTER 0 REVERSIBLE CONTACTORS (STANDARD)
SHEET 1/2 DATE SIGN. TERMINAL PLAN This drawing and the information it contains are property of Rotork Controls Limited, and they will not be reproduced or
disclosed, in whole or in part, without the prior written consent of Rotork.

MADE BY 17-12-2015 IM WD CKC-CKRC CTK., DSM, 3PH,

ra nge
CUSTOMER SUPPLY & BLUETOOTH 3 115VAC, AND BLUETOOTH CARD FOR REMOTE SETTING TOOL FORMAT DRAWING Nº
CHECKED 17-12-2015 JAP NOEX1, NOEX2, CTOR, CS115-BT,
K0000300X - 2
BACKUP SUPPLY & HEATER 0
EXTRA SWITCH 0
NO BACKUP SUPPLY, AND NO HEATER
STANDARD: WITHOUT APPROVED 17-12-2015 JAP NB-NH, NOEXT A4
1 2 3 4 5 6 7 8
CK-WD
1 2 3 4
REMOTE INPUTS FOR ACTUATOR CIRCUIT
120VAC 5A max
30VDC 5A max DIAGRAMS AND REMOTE
POWER (1-4) MONITOR CONTROL CIRCUITS,
CUST.

(-)COM REMOT.
REFER TO CK00500

A
SUPPLY OUTPUT RELAYS RELAY
SUP DATASHEET

(-)COM ESD
120VAC 5A max
30VDC 5A max

(+)CLOSE
PS

(+)OPEN
(+)STOP
USER PE L1 L2 L3 115VAC

(+)ESD
PS PS PS PS

MON.COM

(+)IL1

(+)IL2
EXT. (5W ma x)

MON.NC

MON.NO
~ ~

R1

R2

R3

R4
F.EXT.

E L1 L2 L3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55

LM.17
3

K0000300
LM.3
LM.18
2
19

SK7 SK11 SK3

CENTRONIK TERMINAL PLAN:


CONF
EEPROM
B

SK2
Warning!
(MAXIMUM, 2 OPTION BOARDS)
! See NO TE

THERMOSTAT
LK2
OVERRIDE
SK4 SK8 SK10 SK6 SK5 SK9
CPIO
LM.14 LM.15 LM.16
LM.13
4
CENTRONIK

20 22 8
ENGINEER

SK4 SK1

* FS3 (1A ,24V.CTOR)


( )

LM.6 ENGINEER
SK2
16 LM.9
* FS4 (1A ,24V.CTRL)
( )

SK2 SK5 4
SK3
PS *
( ) FS2 (24V .ACT)

LM.11
LM.3

2
SK13 ( )
* FS6
(0.5A,24V.CUST)
SK1 SK8
+
OPEN
C
CUST
1 IN HAND
SK3
SK1 -
CLOSE
LM.8

D000000
LM.2
(0.1A,120V.CUST) 3 LOCAL
3 SK4 LM.14 CENTORK
( ) FS5
* LM.10 CK2
OPT 22
5 STOP
BT

1 2 3 PH1 REMOTE
SK3
SK9 LM.7 HMI

ACTUATOR TERMINAL PLAN:


U
5
1 3 5 PH3
A1
SK11 V SK6 20
MOTOR
LK1/W
STARTER PH2 * FS1
( )
SK1
A2 LK2/X
2 4 6 SK10 W
LK3/Y
LK4/Z
ST TF BT
U V W

LM.1
D
3

E L1 L2 L3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55

+24 +5 +OV C- C+
M

M1 TRM DSM

ACTUATOR TERMINAL PLAN: D000000 ACTUATOR

( )
* ! WARNING: REFER TO SAFE USE AND INSTALLATION MANUAL OR CK00500 DATASHEET FOR APPROVED FUSES.

FS1: A CCORDING TO THE POWER SUPP LY VOLTAGE 110VAC/115VAC:


ANY OTHER V OLTAGE:
FS1 (0,5 A)
FS1 (0 ,25 A)
TRANSFORMER TAPPING OPTIONS E
THE TERMINAL PLAN SHOWS THE MULTI-TURN ELECTRIC ACTUATOR IN INTERMEDIATE POSITION, ACTUATOR CLOSES VALVE PRIMARY TAP NOMINAL VOLTAGE (VAC 50/60Hz)
CLOCKWISE.
REFER TO SAFE USE AND INSTALLATION MANUAL AND DATASHEETS FOR TECH. DATA, PARAMETERS AND DESCRIPTION OF THE TAP LV EU HV
ACTUATOR ELECTRIC AND ELECTRONIC EQUIPMENT.
ACTUATORS WITH SOLID STATE STARTER (SSS), THE ACTUATOR MUST BE PROTECTED USING SUITABLE RATED HIGH SPEED LK1 W 110/115/120 380 460
SEMI-CONDUCTOR FUSES ON THE INCOMING SUPPLY LK2 X 220/230 400 480
IF THE ACTUATOR IS CONFIGURED TO BYPASS THE MOTOR PROTECTION THERMOSTAT (TRM), THE ACTUATOR WILL NO LONGER
COMPLY WITH THE ESSENTIAL SAFETY REQUIREMENTS. LK3 Y 240 415 500
THE USER MUST CONDUCT A RISK ASSESSMENT, AND IMPLEMENT WHATEVER EXTRA SAFETY MEASURES ARE REQUIRED, TO
ENSURE THAT THE RESULTANT SYSTEM COMPLIES WITH THE LOW VOTAGE DIRECTIVE, AND ANY OTHER LEGISLATION IN FORCE AT LK4 Z n/a 440 600
THE INSTALLATION SITE.

ISSUE DATE ISSUE DATE


1 FIRST RELEASE 17-12-15 3 - -
2 REDRAWN IN SOLID EDGE 15-06-16 4 - -

SHEET 2/2 DATE SIGN. WIRING DRAWING This drawing and the information it contains are property of Rotork Controls Limited, and they will not be
reproduced or disclosed, in whole or in part, without the prior written consent of Rotork. F
MADE BY 17-12-2015 IM WD CKC-CKRC CTK., DSM, 3PH,
ra nge

FORMAT DRAWING Nº
17-12-2015 JAP NOEX1, NOEX2, CTOR, CS115-BT,
CHECKED
APPROVED 17-12-2015 JAP
NB-NH, NOEXT
A4 K0000300X - 2
CK-WD