1833-08-SKE-1101_Incline Conveyors Systems Identification_Rev.

1833-307-02

1833-307-02

Drawing No. to be
identified in next
markup revision

1833-601-02

1833-25-J1-1689 1833-301-02
CW2100438-B011-0083_R3

1833-301-02

1833-601-02

1833-301-02

1833-601-03

1833-08-SKE-1101_2
1833-08-SKE-1101_Incline Conveyors Systems Identification_Rev.2

MULTI-FUNCTION MODULE #5 / DWG# 1833-55-L4-1682 (A15518-1)

1833-601-02i
1833-PI-0109
1833-PCV-0115 0-100
1833-PI-0113
1833-PIT-0100 PRV1
0-160 PI
1833-PIT-0101
SERVICE AIR DN25 (1"NPT)
PT1 PI PT2
2100.0 L/M @ 689.5 kPa AFIL1 1833-PCV-0116
PRV2
(3) DSN-6 FOGGER ASSEMBLIES
@ DISCHARGE 1833-CVB-2020
6011 1833-25-J1-1681
PI

FROM TRANSFER STATION #22


0-30
1833-AP-2538-C1A-0001"-NI 1833-PI-0115

DRAIN

1833-307-02
VENT

(7) DSN-6 FOGGER ASSEMBLIES


@ FEED POINT 1833-CVB-2021 Contractor/Supplier/Vendor Technical Document
1833-PI-0108 and Drawing Review for SN1809A0 ‐ OT
1833-PCV-0114 0-30
Underground Project
PRV3 PI

Reviewed with No Comments.


1
(Construction/Fabrication may Proceed)

Reviewed with Minor Comments.


2 Revise and resubmit "Final Version" incorporating comments.
(Construction/Fabrication may proceed thereafter)
Rejected with Major Comments.
1833-SV-0102 3 Correct and resubmit "For Review" incorporating comments.
(DO NOT PROCEED with Construction or Fabrication)
SV2
Not Reviewed ‐ Received For Information Only.
4
No further submission is required.
S
Received Certified/Equipment Package Vendor Document.
1833-SV-0104 X 5
Received As Built ‐ Contractor Document.

SV4
6 Cancelled.

S
Submit Certified Document.
YES NO
Name Alonso Ro-
1833-SV-0103 Responsible Engineer Signature jas
Date ARC
SV3
Equipment Tag No.
S
Client Document No. 1833-25-j1-1801
Jacobs Document No. and
Revision CW2100438-B011-0103_R1
AUTHORISATION TO PROCEED DOES NOT RELIEVE THE VENDOR/CONTRACTOR OF ANY RESPONSIBILITY, OBLIGATION OR
LIABILITY UNDER THE PURCHASE ORDER/CONTRACT. NO RESPONSIBILITY IS ASSUMED BY JACOBS FOR CORRECTNESS OF
DIMENSIONS OR DETAILS. SHOP DRAWINGS ARE ACCEPTED AS FOR INFORMATION ONLY (NOT REVIEWED).
VENDOR/CONTRACTOR IS FULLY RESPONSIBLE FOR SHOP DRAWINGS.

1833-301-02 1833-PI-0110
"SUPPLY"
1833-PI-0111
"PRIMARY"
1833-PI-0112
"SECONDARY"
0-100 1833-PIT-0102 0-100 0-100 1833-PIT-0103 1833-FE-0199

SERVICE WATER DN15 (1/2" NPT) PT3 PT4 FT


PI PI PI
5.0 L/M @ 344.7 kPa WFIL1 WFIL2

6012 1833-25-J1-1681
100 MICRONS 5 MICRONS
FROM TRANSFER STATION #22
1833-WP-2705-C1A-0001"-NI SV1 1. ALL ELECTRICAL INSTRUMENTATION IS WIRED TO ECM #5 PLC. (SEE
S

1833-65-L5-1765 FOR REFERENCE)


1833-SV-0101 2. AIR & WATER TUBING IS ROUTED INSIDE LIQUID TIGHT CONDUIT
TOGETHER EXTERNAL FROM THE MULTI-FUNCTION MODULE UNTIL THEY
REACH THE NOZZLE ADAPTOR. (SEE 0000-55-L4-1760 FOR REFERENCE.)
3. FOR REFERENCE ONLY: DSI DRAWING #A15503-9
DRAIN VENT DRAIN

Dust Solutions,
P.O. Box 4397
Inc.
Beaufort, South Carolina, 29903
Tel. +1 843-846-3700 Fax +1 843-846-3701
KEY: SELF-CLEANING FILTER
Web: nodust.com Email: support@nodust.com
ELECTRIC SIGNAL CHECK VALVE
PNEUMATIC SIGNAL G INDICATOR LIGHT
S
HAND ACTUATED VALVE
SOLENOID VALVE - FAIL CLOSED
PI
PRESSURE INDICATOR
CARTRIDGE FILTER

PARTICULATE FILTER - AUTO DRAIN


thyssenkrupp
S

S
SOLENOID VALVE - FAIL OPEN
PT

PS
PRESSURE TRANSMITTER
COALESCING FILTER - AUTO DRAIN
Industrial Solutions
SOLENOID VALVE - 3 WAY PRESSURE SWITCH thyssenkrupp Drawing No.
FT
FOGGING NOZZLE
PRESS. REGULATING VALVE FLOW TRANSMITTER TUS-EQM-2024-DZ-0001-021
DES. DES. PRODUCED BY DESIGNED BY DRAWN BY
REV. DATE REVISION DESCRIPTION APPROVED REV. DATE REVISION DESCRIPTION APPROVED REFERENCE DRAWING No. REFERENCE DRAWINGS OYU TOLGOI UNDERGROUND PROJECT
CHK. CHK. DSI INC. GJB GJB
PROJECT NO CHECK DESIGN CHECK DRAWING
1833 TRANSFER TOWER 22
1 12/22/17 SUBMITTAL 1833-55-L4-1689 1833-DCD-2021 INTERCONNECTION DIAGRAM
DUS 00022 WLD WLD
DUST SUPPRESSION
1833-DCD-2021
2 04/04/18 CUSTOMER COMMENTS 1833-65-L5-1765 1833-DCD-20121, ECM #5 SCHEMATIC CONTRACT NO LEAD ENGINEER APPROVAL DATE
PIPING AND INSTRUMENTATION DIAGRAM - MFM #5
CW2100438 S.SLAVOV
3 05/08/18 SUBMITTAL Disclaimer: Drawings, plans, models, designs or any other information displayed, contained in, made available or disclosed in or by this
document (or its part or attachment) is owned by Oyu Tolgoi LLC and may be a proprietary of Oyu Tolgoi LLC and hence they are for the
DRAWING SIZE AREA PROJECT ENGINEERING
MANAGER
ENGINEER
internal use of Oyu Tolgoi LLC only. Making a copy or reproduction thereof in any form or giving an access or possession of them to any other NTS R.LEZIUS
4 12/23/19 UPDATED NOTES party without Oyu Tolgoi LLC's written consent or permission shall be strictly prohibited. Any violation (actual or attempted) of these terms
and prohibitions shall be subject legal liabilities and Oyu Tolgoi LLC reserves its rights and entitlements to all available legal remedies.
PLOT SCALE PROJECT MANAGER APPROVAL DATE
үү ү үү ү үү ө
үү ө ө ө өө
ө ө ө өө ө ө ө ө T.MESS
ө өө ө өө ө ү
ү CAD FILE NAME CLIENT APPROVAL DATE SCALE DRAWING NUMBER REV.
ө ө ө ө ө ү ө
ө ү ө өө ү ү
NTS 1833-25-J1-1801 4