Professional Documents
Culture Documents
Fixing:- No. 22
Fixing:- No. 22
Fixing:- No. 22
Fixing:- No. 22
Fixing:- No. 26
Fixing:- No. 17
Fixing:- No. 17
Fixing:- No. 17
Fixing:- No. 17
Fixing:- No. 17
Fixing:- No. 3
Urinal Partition
14 Installation, of Urinal HPL Partition moulding to outer edge size
0.45m x 1.2m inserted 12 mm inside wall..
Fixing:- No. 7
Installation of white vitreous China battery based infrared sensor
operated urinal of approx. size 610 x 390 x 370 mm having pre &
post flushing with water (250 ml & 500 ml consumption), having
water inlet from back side, All necessary item required to complete
15 install the Fixture to wall with suitable brackets all as per
manufacturers specification and direction of Engineer-in-charge.
Fixing:- No. 7
Fixing:- No. 7
Fixing:- No. 2
Fixing:- No. 2
Fixing of (25
No. 15
LTRS. capacity) :-
Fixing of (100
No.
LTRS. capacity) :- 2
WATER SUPPLY
Supplying, installing, fixing, jointing, testing and commissioning of
approved make Chlorinated Polyvinyl Chloride pipes (CPVC) up to 50mm
dia SDR.11, ASTM CTS , and above 50mm dia CPVC schedule 40 ASTM IPS
(IS 15778 (2007). Fittings up to 50mm dia SDR.11, The fittings and specials
such as tees, elbows, couplers, bends, enlargers etc.,m with CPVC brass
threaded combination / transition specials such as male adapters brass
threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where
connection with metal is to be made including necessary drilling holes,
chasing walls and making the same good in cement martor 1:1 restore
1 the same original condition neately as directed by the Engineer incharge.
Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM
D2846 and above 50mm dia primer P70, and solvent confirming to ASTM
F4931 / 724.
a) 15 mm dia Rmt 20
c) 25 mm dia Rmt 90
d) 32 mm dia Rmt 35
3 BALL VALVE
Supplying, installing, testing and commissioning approved make G.M.
body ball valves PN25, IS 1703-1977 with screwed ends,necessary unions
etc., complete.
a) 20 mm dia Nos 22
VALVE CHAMBER
Construction of valve chamber with 230 mm best quality TM bricks in CM
1:4 over a bed of 100mm thick PCC 1:4:8, internal walls plastered smooth
in CM 1:3 and external walls plastered rough with sponge finish including
curing with all necessary leads and lift and providing heavy duty cast iron
cover with frame with locking arrangements etc., complete including
7 Heavy duty cast iron cover of size 600 x600 (weight 115Kgs.) Size of Nos 3
chambers for valves up to 150 mm dia Size 0.6m x 0.6m x 1M (clear
dimension)
DRAINAGE SYSTEM
Supplying, laying, jointing, testing and commissioning approved
make PVC pipes class III 6 Kg/cm2 with solvent cement joints
confirming to IS 4985 for kitchen sink, wash basin outlets Outlets &
Antisyphonage Pipes. The quoted rateshallinclude necessary
chasing in walls makinggood the same in C.M. 1:4, necessary
1 fittingsviz.,elbows,tees etc., with G.I clamps.Anchorfasteners, Grip
bolts, nuts and bolts,etc,complete.
a) 40 mm O. D Rmt 50
b) 50 mm O. D in Kitchen Rmt 50
a) 75 mm O. D Rmt 100
b) 110 mm O. D Rmt 90
d) 75 mm dia Rmt 25
Excavation in trenches in ordinary hard soil (other than in rock
requiring chistelling and blasting) for laying Sewer lines and refilling
of trenches after pipes are laid in layers not exceeding 20 cm
watering and consolidation and disposing off surplus earth as
4 directed by the Engineer incharge, providing necessary Shoring &
Strutting while excavating etc., complete
MAN HOLE
a) Depth Nos
INSPECTION CHAMBER
GULLY TRAP
GREASE TRAP
Constructing Grease Trap of The Contractor shall make sure that all
the associated civil work, incl.----Litre as mentioned below of ---
liquid depth in brick work of class 75 with cement mortar (1:6),
inside plastering16 mm thick with cement mortar 1:3 with floating
coat of neat cement and rough plaster on outside. Including
aluminum bucket as per detail to collect the grease. RCC top slab
with 2 nos. 600 x 600 mm dia medium duty hinged type cover with
9 epoxy coating, double seal manhole covers with frame (weight of
covers & weight of frame 75 Kg), necessary 150 mm thick
foundation concrete (1:2:4). 22000mm x 4900mm as per detailed
drawings and specifications.
CATCH BASIN
Construction of catch basin of size mentioned below upto 600mm
clear internal dimension for storm water with 230mm thick walls in
well burnt table moulded bricks in CM 1:4 over a bed of 100 mm
thick PCC 1:4:8 (M10) internal walls plastered smooth in CM 1:3
and external walls plastered in 1:3 with sponge finish. Fixing precast
Heavy Duty RCC grating of size 550 x550mm on top surface flushed
11 to the finished floor level with necessary excavation, back filling the
selected excavated earth with all leads and lifts etc., complete.
RECHARGE PIT
Supplying, fixing and testing inlet, outlet, vent and over flow pipes,
fittings with C.I frame with cover to Under Ground Sump complete
with PVC rungs, etc complete as shown in the drawing. all puddle
4 flanges to be hot dip galvanized GI 'C' class pipe & flange length -
450mm length as per design drawing.
c) 80 mm dia Nos 4
c) 65 mm dia - UGT Tank outlet , OHT Inlet and OHT Drain Nos 10