You are on page 1of 4

Sludge

Filter Back wash


Sludge
Holding Tank
drying bed

Water Re-cycle
Filter Back wash

Sewage Treatment Plant (STP), Capacity: 2m3/hr.


Sludge Out
Air Line
Sludge Return

Bar Screen
Equalization Tank

Waste Water Inlet


Biological Tank
Settling Tank

Settling Tank
Post Aeration
Treat Water

Flocculation
Secondary

Flash Mixing
Filter Feed Tank

Correction

Oil & Grid Tank


Primary
MGF
RO System
(Optional)
Outlet

Tank
pH
ACF

Filter unit
Air Line

Poly
Acid

BIO

Aeration Blower
Dosing Platform

CLIENT NAME & ADDRESS CONSULTANT NAME:


Sewage Treatment Plant for Expo Accessories Ltd.
Engr. M.M Sanjidul Islam Engr. Mohammad Ariful Molla
Expo Accessories Ltd. B.Sc in Civil, MIEB-M/31346 00 -

Biprobortha, Sadar Thana, GMP,


Gazipur, Bangladesh. 5th Floor, Sena Shopping Complex, Nabinagar, Savar Engr. Md. Suruz Zaman
Process Flow Chart of ETP B.Sc in Civil
30/03/2023 01
Email: ietbd,office@gmail.com
SN Tank Name Tank Size F- Board Volume HRT
Plant Details: 01 Septic/Collection Tank 3.5x2x3m (Bonded) 300mm 20m3 10hr
Sewage Flow Capacity: 2.0m3/hr. 02 Oil &Grid Tank 1x.75x2.1m 225mm 1.5m3 0.75hr
03 Equalization Tank Area: 5.75m2, H-2.1m 300mm 12m3 6hr
Treatment Process: Physico-Chemical followed by 04 Flash Mixing Tank 0.8x0.8x1.25m 150mm 0.50m3 15Min
150mm
Biological Oxidation Process 05
06
Flocculation Tank
Primary Clarifier
0.8x0.8x1.5m
Ø-2.5m, H-2.1m 150mm
0.65m3 18Min
8m3 4hr
with Return Activated Sludge Process 07 pH Correction 0.8x0.8x1.55m 150mm 0.65m3 18Min
08 Biological Tank Area: 18.87m2, H-2.1m 225mm 38m3 19hr
09 Secondary Clarifier Ø-2.5m, H-2.1m 150mm 8m3 4hr
10 Filter Feed Tank Area: 1.65m2, H-2m 300mm 3m3 1.5hr
11 Post Aeration Tank Area: 2.5m2, H-2m 300mm 5m3 2.5hr
12 Sludge Dryer Bed 3x1.5x1.5m 225mm

Temp. DO, pH & TDS Meter Inlet & Outlet


Water Flow Meter Total HRT = 38.25hr

Sludge Holding Tank


(Optional)

Chemical Dosing Unit Water Line

Air Li ne
Sludge Store
Treated Water
Storage Tank
FeSO4 BIO-101 Poly Acid
Lime

Sludge Dryer Bed

Flash Mixing Tank

Flocculation Tank

Primary Clarifier Aeration Line


Agitator Agitator
20RPM
100RPM
Rake Arm pH Controller
Secondary Clarifier Tank
Speed: 10RPM V-Notch
Recycle Activated Sludge (RAS)

Rake Arm Over Flow Drain


Plain Clarifier
Water Inlet Pipe
Plain Clarifier
Floor & Parking Wash
66.0831

Control Panel Board Roots Air Blower


MULTIGRADE SAND FILTER ACTIVATED CARBON FILTER

To Sludge Top Manhole Top Manhole

Holding Tank

Sludge Drying Bed

Bar Screen Sludge


Transfer Pump Flow Meter

G.L

Raw Drain Line Drain Line G.L

66.0831
Sewage Inlet
Toilet/Wash
Effluent
To Re-Used & Drain
Oil & Grid Separator Tank

Influent Lifting Pump

1380.66

Equalization Tank Biological Tank Filter Feed Tank Post Aeration Tank
DO Meter Garden
RAS Pump
Biological Tank
Aeration System

Equalizing of Water & Increase of Aeration/Oxidizing System Secondary Sedimentation System Advanced & RO System Reduce
Chemical &Sedimentation System
Dissolved Oxygen in Water Reduce with Control of BOD, COD & Nitrogen Reduce High TSS & Recycling of TDS, Chloride, Nitrate , Sodium &
is All ways Reduce High TSS
Sludge in Oxidizing Tank Coliforms Bacteria.
Irrigation /Land

CLIENT NAME & ADDRESS CONSULTANT NAME:


Sewage Treatment Plant for Expo Accessories Ltd.
Engr. M.M Sanjidul Islam Engr. Mohammad Ariful Molla 00 -
Expo Accessories Ltd. B.Sc in Civil, MIEB-M/31346
Biprobortha, Sadar Thana, GMP,
Gazipur, Bangladesh. 5th Floor, Sena Shopping Complex, Nabinagar, Savar Engr. Md. Suruz Zaman 30/03/2023
Hydraulic Process Flow Drawing of ETP B.Sc in Civil 02
Email: ietbd,office@gmail.com
Operation Walkway 750mm
MS Ladder RAS Pump
Sludge Pump

Filter Feed Tank Dosing Dosing


Lifting Pump Area: 1.65m2, H-2m Tank Tank

MGF

Filter Unit
Dosing Unit
Equalization Tank Biological Tank

DO Spry Header
Area: 18.87m2, H-2.1m
Area: 5.75m2, H-2.1m .9x.9x.75m
Operation Room

66.0831
Oil Trap Floc. Mixing
Blower Unit

ACF
Outlet
Primary Clarifier Secondary Clarifier
D:2.5m, H-2.1m D:2.5m, H-2.1m
Post Aeration
Inlet .9x.9x.75m
Area: 2.5m2, H-2m
Flash Mixing Panel Board

66.0831
Bottom Tank Layout Plan

U.G. STP TANK AREA

MS Ladder RAS Pump


Sludge Pump

Filter Unit
Dosing Dosing
Lifting Pump Filter Feed Tank Tank Tank
Area: 1.65m2, H-2m

MGF
Equalization Tank Biological Tank

Filter Unit
Dosing Unit
Area: 5.75m2, H-2.1m Area: 18.87m2, H-2.1m

DO Spry Header
Floc. Mixing Operation Room

66.0831
Oil Trap .9x.9x.75m
Blower Unit

ACF
Outlet
Primary Clarifier Secondary Clarifier
D:2.5m, H-2.1m D:2.5m, H-2.1m
Post Aeration
Inlet Area: 2.5m2, H-2m
Flash Mixing
Panel Board

66.0831
.9x.9x.75m

Aeration System Layout Plan SN Tank Name Tank Size F- Board Volume HRT
U.G. STP TANK AREA 01 Septic/Collection Tank 3.5x2x3m (Bonded) 300mm 20m3 10hr
02 Oil &Grid Tank 1x.75x2.1m 225mm 1.5m3 0.75hr
03 Equalization Tank Area: 5.75m2, H-2.1m 300mm 12m3 6hr
04 Flash Mixing Tank 0.8x0.8x1.25m 150mm 0.50m3 15Min
05 Flocculation Tank 0.8x0.8x1.5m 150mm 0.65m3 18Min
06 Primary Clarifier Ø-2.5m, H-2.1m 150mm 8m3 4hr
07 pH Correction 0.8x0.8x1.55m 150mm 0.65m3 18Min
08 Biological Tank Area: 18.87m2, H-2.1m 225mm 38m3 19hr
09 Secondary Clarifier Ø-2.5m, H-2.1m 150mm 8m3 4hr
10 Filter Feed Tank Area: 1.65m2, H-2m 300mm 3m3 1.5hr
11 Post Aeration Tank Area: 2.5m2, H-2m 300mm 5m3 2.5hr
12 Sludge Dryer Bed 3x1.5x1.5m 225mm

Total HRT = 38.25hr

CLIENT NAME & ADDRESS CONSULTANT NAME:


Sewage Treatment Plant for Expo Accessories Ltd.
Engr. M.M Sanjidul Islam Engr. Mohammad Ariful Molla 00 -
Expo Accessories Ltd. B.Sc in Civil, MIEB-M/31346

Biprobortha, Sadar Thana, GMP,


Gazipur, Bangladesh. 5th Floor, Sena Shopping Complex, Nabinagar, Savar Engr. Md. Suruz Zaman 30/03/2023
Tank & Aeration System Layout Plan B.Sc in Civil 03
Email: ietbd,office@gmail.com
Syphon Ventilation

MS Ladder Operation Walkway 750mm RAS Pump

(Frsh Air) Ventilation


Sludge Pump

Syphon Inlet
Dosing Dosing
Lifting Pump Filter Feed Tank Tank Tank
Area: 1.65m2, H-2m

MGF
Biological Tank

Filter Unit
Dosing Unit
Equalization Tank Area: 18.87m2, H-2.1m
Area: 5.75m2, H-2.1m

DO Spry Header
Floc. Mixing
Operation Room

66.0831
.9x.9x.75m
Oil Trap
Blower Unit

ACF
Outlet
Primary Clarifier Secondary Clarifier
D:2.5m, H-2.1m D:2.5m, H-2.1m

Inlet Flash Mixing Post Aeration


.9x.9x.75m Area: 2.5m2, H-2m Panel Board

66.0831
Syphon Ventilation Bottom Tank Layout Plan

Operation Walkway 750mm


MS Ladder RAS Pump
Sludge Pump

Dosing Dosing
Lifting Pump Filter Feed Tank Tank Tank
Area: 1.65m2, H-2m

MGF
Equalization Tank Biological Tank

Filter Unit
Dosing Unit
Area: 5.75m2, H-2.1m Area: 18.87m2, H-2.1m

DO Spry Header
Floc. Mixing Operation Room

66.0831
Oil Trap .9x.9x.75m
Blower Unit

ACF
Outlet
Secondary Clarifier (Room Height: 11'-0")
Primary Clarifier
D:2.5m, H-2.1m D:2.5m, H-2.1m
Post Aeration
Inlet Area: 2.5m2, H-2m
Flash Mixing
Panel Board

66.0831
.9x.9x.75m

Aeration System Layout Plan

Underground
Septic Tank (If Possible) Underground
Septic Tank

ST.TOILET
FEMALE WORKER

MALE WORKER

The septic tank should be built


TOILET 7 nos
TOILET 6 nos

under the bicycle garage


GREEN
DAY CARE & AREA
STORE

Option-2
MEDICAL CENTER
Ground Floor
UP Dryer Bed
STAIR LEVEL
LEVEL +450mm
LEVEL+450mm
+450mm

STORE

LEVEL(±)00mm LEVEL(±)00mm

CLIENT NAME & ADDRESS CONSULTANT NAME:


Sewage Treatment Plant for Expo Accessories Ltd.
Engr. M.M Sanjidul Islam Engr. Mohammad Ariful Molla 00 -
Expo Accessories Ltd. B.Sc in Civil, MIEB-M/31346

Biprobortha, Sadar Thana, GMP,


Gazipur, Bangladesh. 5th Floor, Sena Shopping Complex, Nabinagar, Savar Engr. Md. Suruz Zaman 30/03/2023
Ventilation & Septic Tank Layout Plan B.Sc in Civil 04
Email: ietbd,office@gmail.com

You might also like