Procedure

1. Open the right and top cover on the wire panel (dismount the wire panel if need).

2. Remove the old anti-switch and install new switch.

3. Connect the cables to the anti-collision switch.

https://gfms.georgfischer.com/sites/kc/BAC/CUT_E_350_CUT_E_600/HTML/Menu_Machine/Index_CUT_E_350_600_MarkI.htm 1/3
13/08/2021 Z_axis_AntiCollision_Switch_Replacement

4. Adjust the gap between anti-collision and plate (0.4mm) and then fix it on the switch support.

5. Lay the cable follow the picture hereunder and connect to connection plate behind Z column.

https://gfms.georgfischer.com/sites/kc/BAC/CUT_E_350_CUT_E_600/HTML/Menu_Machine/Index_CUT_E_350_600_MarkI.htm 2/3
13/08/2021 Z_axis_AntiCollision_Switch_Replacement

6. Recover all the covers.