You are on page 1of 9

11/2/2023 | Page 1 of 9

ORIENTAL MOTOR U.S.A. Corp.


570 Alaska Avenue
Torrance, CA 90503
1-800-GO-VEXTA (468-3982)

Item # BXM5120-A2 / BXSD120-A2, 120 W (1/6 HP) Brushless DC Motor Speed Control System (Single-
Phase 100-120 VAC)

The BXII Series brushless DC motor and driver packages offer high Web Price
performance and high function, now up to 4,000 r/min, for a wide
range of applications. The driver is user friendly with easy wiring, data
setting and LED display on the front panel and is compact and easy $771.00
to mount.
Speed Control, positioning, torque limiting
Speed Control Range: 2 ~ 4000 r/min (digital setting), 30 ~ 4000
r/min (analog setting)
MEXE02 software (free download) or OPX-2A Control Module
(sold separately)
Motor

more

Specifications | Driver Functions | Speed-Torque | Dimensions | System

Specifications

Motor Type Brushless DC Motor

Motor Frame Size 3.54 in.

Output Power 120 W (1/6 HP)

Power Supply Single-Phase 100-120 VAC

50 Hz
Frequency
60 Hz

Rated Input Current 3.7 A

Shaft/Gear Type Round Shaft (No Gearhead)

Output Shaft Diameter 12 mm

Degree of Protection (Motor) IP54

Rated Torque 3.5 lb-in


11/2/2023 | Page 2 of 9

Electromagnetic Brake Not Equipped

Digital setting: 2 ~ 4000 r/min (2000:1)


Variable Speed Range (r/min)
Analog setting: 30 ~ 4000 r/min (133:1)

Permissible Load Inertia 3.40 oz-in²

0.39 in. from Shaft End = 35


Permissible Overhung Load
0.79 in. from Shaft End = 39 lb

Permissible Thrust Load Half of motor mass ot less

Max. Extension Length (m) Motor and driver distance: 99.7 ft. (30.4 m)

BXSD120-A2 [Driver]
Components
BXM5120-A2 [Motor]

These products do not contain substances that exceed the


RoHS Compliant
regulation values in the RoHS Directive.

UL
Safety Standards CSA
CE

Low Voltage Directives


CE Marking
EMC Directives

100 MΩ or more when 500 VDC megger is applied between the


Insulation Resistance (Motor) windings and the case after continuous operation under normal
ambient temperature and humidity (except for encoder).

100 M Ω or more when 500 VDC megger is applied between the


power supply input terminal and the case, and between the
Insulation Resistance (Driver)
power supply input terminal and the I/O terminal after continuous
operation under normal ambient temperature and humidity.

Sufficient to withstand 1.5 kVAC at 50 Hz applied between the


windings and the case for 1 minute after continuous operation
Dielectric Strength (Motor)
under normal ambient temperature and humidity (except for
encoder).

Sufficient to withstand 1.5 kVAC, 50 Hz applied between case


and power supply input for 1 min. and 1.5 kVAC, 50 Hz applied
Dielectric Strength (Driver) between power supply input and the I/O terminal for 1 min. after
continuous operation under normal ambient temperature and
humidity.

Temperature rise of the windings is 50ºC (90ºF) max. and that of


the case surface is 40ºC (72ºF) max, measured by the
Temperature Rise (Motor)
thermocouple method after rated continuous operation under
normal ambient temperature and humidity.

Temperature rise of the heat sink is 50ºC (90ºF) max. measured


Temperature Rise (Driver) by the thermocouple method after rated continuous operation
under normal ambient temperature and humidity.

Ambient Temperature Range 32ºF ~ 122ºF (0ºC ~ 50ºC), nonfreezing


11/2/2023 | Page 3 of 9

Ambient Humidity 85% max. (non-condensing)

No corrosive gases or dust. Cannot be used in a radioactive


Operating Atmosphere
area, magnetic field, vacuum, or other special environments.

Altitude Max of 10000 ft. (3000 m) above sea level

Insulation Class UL/CSA Standards: 105 (A), EN Standards: 120 (E)

IP54 (excluding installation surface and connectors) [Motor]


Degree of Protection
IP20 [Driver]

Driver Functions

Speed Control Mode

Digital Setting:

Control panel
MEXE02 software
OPX-2A (sold separately)
Speed Control Method (Select
one of the following) Analog Setting:

Internal speed potentiometer


External potentiometer or DC voltage, 0~10 VDC (1 mA
min.)

Digital Setting: 0.000 ~ 30.00 s (rated speed, no load)


Acceleration/Deceleration Time
Analog Setting: 0.1 ~ 30 s (rated speed, no load)

Digital Setting: Select one of the following methods: (Individual


settings)

Control panel
MEXE02 software
Acceleration/Deceleration Time OPX-2A (sold separately)
Setting Method
Analog Setting: Common to operating Data No. 0 and No. 1

Acceleration time potentiometer (ACC)


Deceleration time potentiometer (DEC)

Operation Data Setting Number 16 Points

Operations can be selected when the motor is at standstill


Operation During Motor Motor non-excitation (initial setting)
Standstill
Position holding by servo control (motor excitation)

Other Operations JOG operation, test operation, teaching (excluding MEXE02)


11/2/2023 | Page 4 of 9

Position Control Mode

Travel Amount Setting Range -8,388,608 ~ +8,388,607 step

Resolution 0.72º (500 steps/rotation)

Operating Modes Incremental or absolute

Operation Functions Independent, linked, linked 2, sequential, direct

Positioning Accel/Decel Time 0.000 ~ 30.00 s (rated speed, no load)

Continous operation, JOG operation, return-to-home operation,


Positioning Operations
test operation, teaching

Torque Control Mode

The motor's output torque can be limited in speed control mode


Torque Limit Control
and position control mode.

Torque Limiting Setting Range 0 ~ 250%

Digital Setting: Select one of the following methods:

Control panel
MEXE02 software
Torque Limiting Setting OPX-2A (sold separately)
Methods
Analog Setting:

External Potentiometer or external DC voltage, external


analog setting with 0~10 VDC (1 mA min).

Speed-Torque
11/2/2023 | Page 5 of 9

Dimensions
11/2/2023 | Page 6 of 9
11/2/2023 | Page 7 of 9

System
11/2/2023 | Page 8 of 9
11/2/2023 | Page 9 of 9

1
Quoted Ship Date for orders placed before 12:00 pm PST. Quantities may affect Shipping Date.

©2017 - ORIENTAL MOTOR U.S.A. Corp. - All rights reserved.

Site Search…

You might also like