You are on page 1of 9
eugunal re ENVIRONMENT REHABILITATION PROGRAM ENSHARI a NDER UN LEGISLATION FOR INDEMNIFICATION Project: South Kuwait Excavation, Transportation & Remediation Project (SKETR-Il) Project, Zone-A Contract No: 23059088 REQUEST FOR INSPECTION (RFI) Company Representative / To FCs FL Number 23059088-SKA-QMA-RFI-00027 From Enshaat/Dekonta A. S Date &Time | 24/0ct/2023 & 08:30 AM TTP Ref. & | 23059088-SKA-EN-ITP-00006 | inspection Location | — Activity ID & ID: EN-006-04. (Subarea / Subzone / Grid) Stople Siea She lui cones) | 1. Preparation & Collection and Handling of Contaminated Soil (EN-ITR-00027-01) Attachments | >. Field Log 3. Photos Oowil Duxo © Environmental CO Mechanical Inspection Type: Cetectrical General Intervention Point: D Review Bi witness Dold Inspection Activity: Collection and preparation of Contaminated Soil Sample (TPH >5% to <7%) for base line Analysis from SKETR, Zone-3 Stockpile Area for TOS Portion 3C. ‘Submitted (Contractor) | SELVAMURUGAN RAMAR Received (Company) Date & Sign 21/Oct/2023 v2 Lh. é Date & Sign 21 OCT 2023 Time 10:00 AM Time ‘Company / PMC Remarks: Inspection Result: Zrrenoveo C1 resecteo Subcontractor Contractor Company / PMC een na Niyaz Shaik ; - Ezekias Foncordas | Ey ji Designation neat Environmental Engineer | E:vitonment Engineer Signature & Date QAIQC ENGINEER 2b 0CT 208 U, SKETR Il - ZONE A Sn peor Rew 8 ne Os 2023) SHIBIN MOHAN QAlQc surveyor.) o os wal 202F * Days ENSHAAT QO DEFT: BY: — ENGHAAL d&@nta Project: South Kuwait Excavation, Transportation & Remediation-I (SKETR-II) Project, Zone-A No: 23059088 Inspection & Test Record (ITR} TTR Form: 23059088-SKA-EN-CHK-00037 Rev. A Preparation, Collection & Handling of Contaminated Soil for TOS TTR No. 73059088-SKA-QA-RFI-00027.1 Date 24-Oct-2023 RFIReference | 23059088-SKA-QA-RFI-00027 peeation / | stockpile Area SKETR- Zone -3 Drawing/ 5 Document No. es si. a Inspection Findings | No. Recaro Satisfactory | Unsatisfactory | _*°™*"*S ‘Allnecessary work permis (approved sile 1. | pians, Work method statements and JSA) obtained a oa and proper liaison provided Safely arrangements and measures appropriately 2. | made; safety toolbox talk conducted before starting ag oO the work 3. | Verify the necessary Tools available while collecing a D and handling of contaminated soils for TOS | ‘Sampling location inspected as per approved sampiing | 4 | oan a o 5, | Field Screening Equipment analysis proved the 2 o expected soil contamination level Calibration certificates of Lab & Field instruments are © | vali Es a 7_ | Mixed soil sample willbe prepared from soll deposited a oO at the contaminated soil stockpile area, «a, | Vetify the mixed soil sample will be screened at 20 a Oo mm sieve and homogenized Confirm that the TPH content in the mixed soil sample 9, | is within the expected interval (1% to <2%) or (>2% a o to <5%) oF (>5% to $7%) or Two analytical samples will be prepared from i (by 410.) quartering) and sent to the approved laboratory for a ao 9. TPH analysis. “The homogenized mixed soil sample willbe placed in ia 11.| four separate plastic containers - approx. 50 kg of soil a a he to each container Containers will be marked with the corresponding test 12.) number o el Nb- KOC /PMC Remarks: ITR STATUS accepted CO] NOTACCEPTED Subcontractor Contractor KOC / PMC Name Niyaz Shaik : a Environmental zekias Foncardas | Designation ah Engineer Environment Engineer Signature & Date \ | stamp Form No: 23059088-SKA-QA-FRM-00002 Rev. A & Date, 10-July-2023 24 M10 fas Page tof Project: South Kuwait Excavation, Transportation & as Remediation-II (SKETR-Il) Project, Zone-A NSHARL 2 ota sioner FIELD LOG SHEET 23059088-SKA-EN-CHK-00001 Rev. A Project Name & Location Client Name Contract No Weather South Kuwait Excavation, Transportation & Kuwait Oil Remediation-II (SKETR-II) Project, Zone-A Company ae Goong ‘Type of Topographic Equipment | [1] GPS O Total Station | C1 Others (Specify): Date | 24-10-2013 Time Start Pibam Time Finish TiZp amy UTM Zone: GPS Coordinates Easting: | F914 1-> Northing: | 3 200870 .0 ‘Type of Sampling | (U-Hfand | 1 Mechanical 7 Equipment Tools | Equipment | “ Geoprobe | Cl Others (Specify) jatpa | Existing Feature | Sub Trial Pit Completion s Tyre feat | CiCIs | iey ean Dery Type of Sampling DoL = ae = - - GGrab Ci Composite Depth Soil Description including Visual Container © ronaies: Layer No | Sample ID ie Loore sel, Brown Visual Comte - eee ane 3 en BL-Snghs} Glarte Ave gnined Silty Samet, Pg Pi ce Remarks: Pit Photo No.: ae General Photo No: 44 Pit Arising Photo No.: 4B Sampling Jar Photo No.: a Sub Contractor Contractor ‘Company Name: Shak Nga Designation: N46 Enu. x Bins ‘i Sign & Date SS N= Form No: 23059088-SKA-OA-FRM-00017 Rev. A & Date. 17-Aue-2023 Pace tof 1 Photo ID: 14 Photo ID: 18. | A, | ames] SS) wig_adanny w amenduay sjdums ile PVT [sm vad ONG SEAAT _aeIu pay¥ag 29I003 MPL uN | OND STE Sarmn prea ION TTS TAR TARTS aT WRAY ATOTOTPT ig way antic aydues Ch wones07 Buydues &) | ewdesBovoua BR BA HATO TH BF BTN AH FO TOO RF TATI THT ATO PO Toe TON olololo,olo ofo/ojolofalojojalofa L [2 o fofojofafo ofo[elole[elefalale[a $ ofofojofofo olofoalolofafofofafa[o ¥ ofofojefafa ofo[alolelefol[oalelale € ofofofofofo ofofo olofofojolafa %eo- 3s - 1d z o [ofofol alfa ofofa ofofofofalolo 227 2t -19 T > Elol2z zz 5 al4 7 7 3 Feild] @/ ER Bieler |. /% 2/318, pe (32 lez le Hy REV E| SREP EGE z)z g| 9 [28 FETE A HE aradues Bie ESE 5 gS |9° [FE (EE aE Fe z iE TRI 2 * RPT Sr ILIV TANOT TOT SST. ROMYSTATINTAT TANTS oes THAD PUOTANS HIBITATG) | ——sa06s067 sadky samieed C UAT mneoo auies | Zon 1ofosa (aa) awondng pung O a Ms ec woo yeeysuz@y!eys'U (a) ardwes 394 paynIeD VA se16so16 auowdeian | £ aaa oa neparneaiva onan: | _ RRA SATS 5091S sa win essen wouns mein | F 304 (an wea duo | TOTS _sva Feydwes | yewm voor gh | JeMO squosURg sappy | & [es RN TT, | Wo-YCPPEC onaor | s-v anova w weg sat samy Awd | * PAHO Na-VAS-BB06S0ET) TIOS - AGOLSAD JO NIVHO BSR OST iS arg piri > Ste ier Ariay sepa IAS ‘Building 195," Flor, West of Abu Fat Al Heri SERVICE +965 22951577 = Fs +965 22251578 Page 1of2 Analytical report Company/Customer Name: Enshaat Al- Sayer General Trading And Contracting /Dekonta Panasoni Tower, Floor #19, Office #68 Fahad AL-Salem Stet, Kuwait City, ile, Kunat Adres: P. ox: 126 SAFAT 13002 Projest Name South Kuwait Excavation, Transportation and Remediation (SKETR-II)-Zone A Projest Project Number: 2309088 MEL Report Number 2310-08 Sampling Date zanoanrs Reporting Date 23/1072023 Dear Client, Attached you find the results ofthe laboratory tests caried out for your project. The sample and projet description were adopted from and the tests caried out according to your order .The eported results refer only tothe tested samples. ‘This centficate contains inclusive atatchment 2 pages. In ease ofa version number of'2 or higher all former versions ofthe certificate are invalid All atatchments are inexticably part ofthis certificate Only reproduction of the whole report is allowed In case of questions and for remarks related t this centifieate for example in ease oF information required about measurement uncertainty ofthe analytical methods, please contact our Customer Support department. Yours Faithfilly, Cte ‘Amjad Alkhatib ‘General Manager ‘main Analytical Report- Soil Popatane. Sava Ero, Tnpratin nd Reaitin KET) Ze Piet Pepstnbe 2088 crib: zane = sea tint zona Signe aout Disorsemnie: nan Teor seplag: A Duvortectvng 02003 Tre offece 1000 AM Repti 31004 remo ia ian ai =a oT See a mace sol * = = sai Tam, in aa aa Io — SST i Pasar Tepe ab et arena ao wa = ears a i ey pee i sae vsersiind A isin 5 aaa eee SR ee = a Breit tase a he ane eS Soo Siueocres sae = a Siiaarecteaheee aes = a Simieselsorers ante = eee Simiemocters wana : ‘= Smooe eo = = Simipsevsormn son tas = Sa roe ae eg wae ie SoS Sie cts poe = soo sini acarestmen be tees = SSeS ssimausmsorens) wn it S =mmase SSimamsmsoiee) Manet : = es a eas ey el 5 aan pou ion, ‘NB Samp Tareas navel MEL: Mile at Enoronmental Labrsres ec =dsu 86 = 3Sy 2€8 0 9e/et/e9 1B ors 2 vi/at/eo 7B avg z S2/SL/09 £B oe 0 Ov/SL/sy +B ——— ee 695 0 2/21/99 BAL sw Hdl 0*H ID/is/es sajdwes = eee 699 £0 Ae|> Apues (%) HdL ~=O7H aunyxey ydag G %(Z-S) Z ajduues R=mScan Certificate of Calibration Certificate No: 5092 Equipment RemScan Serial Number MY2216TS05 Customer Kadhema Scientific Consultancy Certification Date 26 July 2023 Ziltek confirms that this RemScan has been tested and meets operational standards Recommended Re-Certification Date July 2024 Subject to no signs of failure in the meantime Dr Sean Mannin; Chief Scientific Officer Ziltek Pty Ltd

You might also like