You are on page 1of 1

GENERAL NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN M.METERS


L I H G F E J K UNLESS NOTED OTHERWISE
100 2. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH
OTHER RELEVANT ARCHITECTURAL, STRUCTURAL, MECHANICAL
100 1750 5800 4250 4750 7350 5650 2250 28606 49587 1600 100 AND ELECTRICAL DRAWINGS AND ALL RELEVANT SECTIONS
OF THE SPECIFICATIONS.
3. CHARACTERISTIC CUBE STRENGTH OF REINFORCED CONCRETE

100
AFTER 28 DAYS IS 35MPa WITH MINIMUM CEMENT CONTENT

1947
400 Kg/m 3 .
19 5055 19 4. CHARACTERISTIC CUBE STRENGTH OF PLAIN CONCRETE AFTER
28 DAYS IS 20MPa WITH MINIMUM CEMENT CONTENT 250 Kg/m 3.
1750 27800 2250 500 4055 500 5. YIELD STRENGTH OF REINFORCED BARS IS 420 N/mm2.
6. THE CLEAR COVER FOR REINFORCEMENT SHALL BE

500
6464

6464
6450
31800 AS FOLLOWS, UNLESS OTHERWISE SHOWN ON THE DRAWINGS:
a. -- FOUNDATION COVER= 70 mm
(+65.78) b. --WALLS 50 mm
900

6011
T.O.RC c. -- COLUMNS 30 mm
d. -- BEAMS AND SLABS 25 mm
18 18

4200
7. FOUNDATIONS ARE DESIGNED BASED ON BEARING
3446

3446
CAPACITY IS 300 kPa AS PER GEOTECHNICAL REPORT
8. ALL RECOMMENDATIONS IN GEOTECHNICAL REPORT SHOULD BE

900
IMPLEMENTED.
17 800
17 9. SOIL BELOW FOUNDATION (FORMATION LEVEL) TO BE COMPACTED
(+68. UP TO 95%.
6050 31) 10. ALL FIXATION DETAILS AND EMBEDDED PARTS SHOULD BE
5600

5600
10.00° T.O.R COORDINATED WITH FINAL SUPPLIER DRAWINGS.
C INLET PIPES

1000
DN.2500mm 11. Splice length calculated as per ECP203/2020 4-2-5-4-1 / C&D

0
30
16 16

1000
(+65.78) Isolation Joint
(+68.31)

5600
5600

5000
T.O.RC 10.00° T.O.RC

0
900

30
900

600

300
15 15
1000
5600

5000

5600
INLET PIPES
10.00° DN.2500mm

0
30

600

300
14 14
5600

5000

5600
10.00°
5000

0
30

600

300
13 13
10.00°
5600

5000

5600
INLET PIPES

0
30

600

300
12 12
(+65.78) (+65.78) (+68.31)
10.00° 300 mm FIBER CONCRETE SLAB Isolation Joint
5600

5000

5600
T.O.RC T.O.RC T.O.RC
Isolation Joint 50 mm screed

0
polyethlene sheets

30
900 900 900
200 mm cemented sand

600

300
11 11
10.00°
5600

5000

5600
(+68.31) INLET PIPES
78860

300 DN.2500mm

0
T.O.RC

30

600

300
10 10
102286

10.00°
5600

5000

5600
0
30

600

600

300
9 9

(+68.31)
T.O.RC
1000
5600

5000

5600
INLET PIPES
10.00° DN.2500mm

0
30

600

300
8 8
5600

5000

5600
10.00°

0
30

600

300
7 7
(+65.78) (+68.31)
10.00°
5600

5000

5600
T.O.RC T.O.RC
INLET PIPES
DN.2500mm

0
30
900 900

600

300
6 6
10.00°
5600

5000

5600
0
30

REFERENCE DRAWINGS:

600
DOCUMENT NO. DOCUMENT TITLE REV.

300
5 5
5600

5000

5600
10.00°
Isolation Joint
RETAINING WALLS

300
600
4 900/600 WIDTH 4
6050

1000
5600

5600
10.00° 1600
31)
(+68.
C
4200 800 T.O.R
3 3
4940

4940
6411

Hydro . Envir & Infra str . Studies

2 2
17617
4489

4489
(+65.78)
900
15517

14517

T.O.RC
2' 500 4054 500 2' ‫سا‬

1750 27800 2250


4562

4562
5054
31800

1 1
1827

100

PS (04)

00 First ISSUE FOR APPROVAL/ FOR CONSTRUCTION

PUMP STATION RAFT SEC-FOR Walls-REINFORCEMENT N.T.S


DETAILS
(TOTAL PLAN)
1/30
1053-SHD-PUS-RF-005315 00

You might also like