You are on page 1of 1

GENERAL NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN M.METERS


UNLESS NOTED OTHERWISE
2. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH
OTHER RELEVANT ARCHITECTURAL, STRUCTURAL, MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT SECTIONS
OF THE SPECIFICATIONS.
3. CHARACTERISTIC CUBE STRENGTH OF REINFORCED CONCRETE
AFTER 28 DAYS IS 35MPa WITH MINIMUM CEMENT CONTENT
400 Kg/m 3 .
4. CHARACTERISTIC CUBE STRENGTH OF PLAIN CONCRETE AFTER
28 DAYS IS 20MPa WITH MINIMUM CEMENT CONTENT 250 Kg/m 3.
5. YIELD STRENGTH OF REINFORCED BARS IS 420 N/mm2.
6. THE CLEAR COVER FOR REINFORCEMENT SHALL BE
AS FOLLOWS, UNLESS OTHERWISE SHOWN ON THE DRAWINGS:
a. -- FOUNDATION COVER= 70 mm
b. --WALLS 50 mm
c. -- COLUMNS 30 mm
d. -- BEAMS AND SLABS 25 mm
7. FOUNDATIONS ARE DESIGNED BASED ON BEARING
CAPACITY IS 300 kPa AS PER GEOTECHNICAL REPORT
8. ALL RECOMMENDATIONS IN GEOTECHNICAL REPORT SHOULD BE
IMPLEMENTED.
9. SOIL BELOW FOUNDATION (FORMATION LEVEL) TO BE COMPACTED
UP TO 95%.
10. ALL FIXATION DETAILS AND EMBEDDED PARTS SHOULD BE
COORDINATED WITH FINAL SUPPLIER DRAWINGS.
203
11. SPLICE LENGTH CALCULATED AS PER ECP 2020 4-2-5-4-1 / C&D
203
12. BAR BENDING RADIUS CALCULATED AS PER DETAILS CODE 2001 3-3

Y Shape Length Mass % of


Mark [mm] [mm] [mm] QTY [kg] total Notes

11827
1 Y18 12000 19 455.45 0.8% HZ

200
220
2 Y18 3207
3400 85 577.34 1.1% HZ

11527
3 Y18 12000 67 1606.05 2.9% HZ

500
9 12 13 14 15 16
3 4 5 6 7 8 10 11 17

500
4 Y18 3400 67 455.08 0.8% HZ
2927

5 Y18 12000 12000 510 12224.79 22.4% HZ

STARTER BAR 6 Y16 11904


12000 19 359.87 0.7% HZ

120
C3
Starting at level
STARTER BAR STARTER BAR STARTER BAR (74.43) planted on STARTER BAR STARTER BAR STARTER BAR STARTER BAR STARTER BAR STARTER BAR STARTER BAR STARTER BAR STARTER BAR STARTER BAR STARTER BAR
C3 C3 pier C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3
(+74.43) Starting at level Starting at level Starting at level Starting at level Starting at level Starting at level Starting at level Starting at level Starting at level Starting at level Starting at level Starting at level Starting at level Starting at level

110
Slab Thickness 7 Y16 2400 19 71.98 0.1% HZ
(74.43) planted on (74.43) planted on (74.43) planted on (74.43) planted on (74.43) planted on (74.43) planted on (74.43) planted on (74.43) planted on (74.43) planted on (74.43) planted on (74.43) planted on (74.43) planted on (74.43) planted on (74.43) planted on 2314

pier pier pier T.O.C(+74.43) pier pier pier pier pier pier pier pier pier pier pier
700 700 700 700 700 700 700 700

77.50m

410
13 Y16/100

E=77.5m

8 Y16 2400 67 253.82 0.5% HZ


L=4000

13 Y16/100

E=77.5m

13 Y16/100

E=77.5m

13 Y16/100

E=77.5m

13 Y16/100

E=77.5m

13 Y16/100

E=77.5m

13 Y16/100

E=77.5m

13 Y16/100

E=77.5m
N=775

L=4000

L=4000

L=4000

L=4000

L=4000

L=4000

L=4000
N=775

N=775

N=775

N=775

N=775

N=775

N=775
C.J C.J C.J C.J 2014
3324

3327

3327

3327

3327

3327

3327

3327
1170mm

1170mm

1170mm

1170mm

1170mm

1170mm

1170mm

1170mm
11 Y16/100 N=775 L=6000 E=77.5m

11 Y16/100 N=775 L=6000 E=77.5m

11 Y16/100 N=775 L=6000 E=77.5m

11 Y16/100 N=775 L=6000 E=77.5m

11 Y16/100 N=775 L=6000 E=77.5m

11 Y16/100 N=775 L=6000 E=77.5m

11 Y16/100 N=775 L=6000 E=77.5m


11 Y16/100 N=775 L=6000 E=77.5m

9 Y16 12000 12000 510 9659.8 17.7% HZ


6000

6000

6000

6000

6000

6000

6000

6000
11604
10 Y16 12000 67 1269.02 2.3% HZ

420
77.50m
(+65.78)
960mm

240mm 960mm

240mm 960mm

240mm 960mm

240mm 960mm

240mm 960mm

240mm 960mm

240mm 960mm
11 Y16 6000 6000 775 7339.26 13.4% VL
240mm

Starter bars

Starter bars

Starter bars

Starter bars

Starter bars

Starter bars

Starter bars

Starter bars
12 Y18 6000 6000 775 9288.91 17% VL

3324

13 Y16 4000 775 4892.56 9% VL

700
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 14 Y18
3354

4000 775 6192.44 11.3% VL

673
Total mass = 54646 kg

REFERENCE DRAWINGS:
DOCUMENT NO. DOCUMENT TITLE REV.

Wall elevation - wall NO 03


V.OF-Reniforcment Hydro . Envir & Infra str . Studies

NO OF WALLS = 1 ‫سا‬

PS (04)

00 FIRST ISSUE FOR APPROVAL/FOR CONSTRUCTION

N.T.S
PS04 - PUMP HOUSE
Wall reinforce detail-NO 03
16/30
1053-SHD-PUS-RF-005315 00

You might also like