You are on page 1of 4

Technical specification for 100KVA

ተ.ቁ የእቃ ዝርዝር ልዩ መግለጫ


Bidder response
1 Diesel generator Description of minimum
100KVA requirements
soundproof with
installation and
testing ATS Automatic control panel with Automatic control panel with changeover switch.
changeover switch.

ATS with automatic circuit ATS with automatic circuit breakers, voltmeters, Ammeters, frequency
breakers, voltmeters, Ammeters, meter, hour meter, starting key, indicators light for low oil.
frequency meter, hour meter,
starting key, indicators light for
low oil.
Operation condition:
Altitude(m) above 2500-3000 2500-3000
sea level
Air
temperature(0C)
Humidity(%)
Product specification
Standby 125KVA(1 125KVA(100KW)
00KW)
prime 100KVA(8 100KVA(80KW)
0KW)
power (3000 x 1350 x (3000 x 1350 x 1884)
1884)

Dimension(mm)
Weight (kg) Closed set Closed set (soundproof)
(soundproof)
Type

Noise @ 7m(dBA) 24-Dec 24-Dec

Starter
Engine detail:
Combustion system Direct injection Direct injection
Cycle 4(four stroke) 4(four stroke)
Number of cylinders 4 4
Cylinder Inline Inline
arrangement
Engine speed(RPM) 1500 1500
Over speed 1650 1650
trip(RPM)
Displacement(L) 4.87
Bore and stroke(mm) 108 x 133 mm 108 x 133 mm
Compression ratio 16.8:1 16.8:1
Induction Turbocharged and Turbocharged and intercooled
intercooled
Cooling system Water Water
Governor type Mechanical Mechanical
Fuel tank capacity(L) 250L 250L
Fuel Standby power 24-25
consumption(L/hr)

100% prime power 22-22.6


75% prime power 16.9-17.1
50% prime power 11.5-11.8
Total coolant 37-37.5 37-37.5
capacity(L)
Total lube oil 12-12.7 12-12.7
capacity(L)
Accessories detail:
Air cleaner type Dry Dry
Oil filter type Spin on Spin on
Water pump type Centrifugal gear Centrifugal gear driven
driven
Alternator detail:
Excitation Self Self
Insulation Class H Class H
Design Brushless Brushless
Number of poles 4 4
Phase 3 3
Voltage
regulation(%)
Rated power 0.8 0.8
factor(Cos phi)
Protection IP22/23 IP22/23
Voltage(V) 380-440 380-440
Frequency(Hz) 50 50
Current (A) 139.1 @0.8PF 139.1 @0.8PF
Regulator Automatic Automatic
Coupling Flexible disc close Flexible disc close required
required
Bearing single single
Spare parts:
The following number of spare parts should
be supplied with each generating sets.
Oil filter 6 6
Fuel filter 6 6
Air filter 6 6
Additional information and details:
Acoustic enclosure Engine alternator Engine alternator assembly mounted on AVM with silencer
assembly mounted
on AVM with
silencer
Standards Optimizes exhaust Optimizes exhaust bellow to meet stringent sound emission
bellow to meet standards.
stringent sound
emission standards.
Cleanness Corrosion Corrosion resistance, water and dust proof design
resistance, water
and dust proof
design
Accessibility Forklift holes in Forklift holes in base
base
Fire resistant Fire retardant inner Fire retardant inner material
material
Mounting Anti –vibration Anti –vibration
Warranty (month)
Documents, tool kits English English
and manual

You might also like