CERT IFIC AT E OF COM PLIANCE

Certificate Number 20180207-S522


Report Reference S522-20020424
Issue Date 2018-FEBRUARY-07

Issued to: SIEMENS INDUSTRY INC


8 FERNWOOD RD
FLORHAM PARK NJ 07932-1906

This is to certify that CONTROL UNITS, SYSTEM; PROPRIETARY ALARM


representative samples of UNITS; EMERGENCY ALARM SYSTEM CONTROL
UNITS; CONTROL AND COMMUNICATION EQUIPMENT;
ACCESSORIES, RELEASING DEVICE; CONTROL UNITS,
RELEASING DEVICE; EMERGENCY COMMUNICATION
AND RELOCATION EQUIPMENT; CONTROL UNIT
ACCESSORIES, SYSTEM; SMOKE CONTROL SYSTEM
EQUIPMENT
See Addendum Page for Models

Have been investigated by UL in accordance with the


Standard(s) indicated on this Certificate.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 3
CERT IFIC AT E OF COM PLIANCE
Certificate Number 20180207-S522
Report Reference S522-20020424
Issue Date 2018-FEBRUARY-07

Standard(s) for Safety: UL 864, Control Units and Accessories for Fire Alarm
Systems
UL 2017, General-Purpose Signaling Devices and Systems,
Second Edition, revision 2016/01/27.
UL 1711, Amplifiers for Fire Protective Signaling Systems,
Fourth Edition, revision December 28, 2006.
ULC-S527-11, Control Units for Fire Alarm Systems, Third
Edition, 2014/07/01.
UL 2572, Mass Notification Systems, First Edition, Revision
May 11, 2012.
ULC-S559-13, Equipment for Fire Signal Receiving Centres
and System, 2nd edition, January 2013.
ULC-S576-14, Mass Notification System Equipment and
Accessories, First Edition, September 2014
UL 1076 Standard for Proprietary Burglar Alarm Units and
Systems - Edition 5 - Revision Date 2015/03/20
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information

Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 2 of 3
CERT IFIC AT E OF COM PLIANCE
Certificate Number 20180207-S522
Report Reference S522-20020424
Issue Date 2018-FEBRUARY-07

This is to certify that representative samples of the product as specified on this certificate were tested
according to the current UL requirements.

UL(1), ULC - Fire Alarm and Emergency Signaling Equipment:

Models Firefinder XLS, XLSV.

UL(2), ULC - Fire Alarm and Emergency Signaling Equipment:

Desigo Fire Safety Modular and Cerberus Pro Modular.

UL(1), ULC - Fire Alarm and Emergency Signaling Subassemblies:

Models PMI/PMI-REM/PMI-INTL, PMI-2, GPMI-2 Person Machine Interface.

UL(2), ULC - Fire Alarm and Emergency Signaling Subassembblies:

Models PMI-3, GPMI-3, FCM2041-U2, FCM2041-U3 Person Machine Interface; Model PSC-12 Power
Supply; Model PSC-ISO-CBL Isolating Cable; Model PSX-12 Power Supply Extender; Model PTB
Power Termination Board; Models CC-5, CC-2 Card Cage; Models ZIC-4A, ZIC-8B Notification
Appliance Card; Models DLC Initiating Loop Card; Models XDLC Initiating Loop Card; Model MLC MXL
Line Card Loop Driver, Model NIC-C Network Interface Card; Model NRC Network Ring Card; Model
CRC-6 Relay Card; Model CDC-4 Conventional Detector Card; Model ZIC-2C Zone Indicating Card;
Model ZIC-SPC Strobe Power Conditioner.

UL(1) – Security Equipment: Models Firefinder XLS, XLSV

UL(2) – Security Equipment: Models Desigo Fire Safety Modular, Cerberus Pro Modular.

UL(1) – Security Subassemblies: Models PMI/PMI-REM/PMI-INTL, PMI-2, GPMI-2 Person Machine


Interface.

UL(2) – Security Subassemblies: Models PMI-3, GPMI-3, FCM2041-U2, FCM2041-U3 Person Machine
Interface; Model PSC-12 Power Supply; Model PSC-ISO-CBL Isolating Cable; Model PSX-12 Power
Supply Extender; Model PTB Power Termination Board; Model CC-5, CC-2 Card Cage; Model ZIC-4A,
ZIC-8B Notification Appliance Card; Model DLC Initiating Loop Card; Models XDLC Initiating Loop
Card; Model MLC MXL Line Card Loop Driver; Model NIC-C Network Interface Card; Model NRC
Network Ring Card; Model CRC-6 Relay Card; Model CDC-4 Conventional Detector Card; Model ZIC-
2C Zone Indicating Card; Model ZIC-SPC Strobe Power Conditioner.