UL PRODUCT CATEGORY

[Signal and Fire Alarm Equipment and Services] Control Units, System,
UOJZ

See General Information for Signal and Fire Alarm Equipment and Services

GENERAL

This category covers electrical control units for fire­protective signaling systems in accordance
with ANSI/NFPA 72, "National Fire Alarm and Signaling Code."

Products bear marking with respect to the installation environment (indoor or outdoor) and
location (dry, damp or wet). Products investigated for outdoor locations, or indoor locations in
ambient temperatures constantly more than 25°C are marked with the rated ambient air
temperature.

A control unit consists of a unit assembly of electrical parts having provision for connection of
power­supply circuits routed through the control unit equipment by a prescribed scheme of
circuiting. The circuits are extended to separate devices by which the operating parts of the
control units are actuated for signals and to separate or incorporated appliances by which the
signals are indicated, so as to form a coordinated system combination for definite signaling
services.

The Listee of a control unit furnishes the related actuating devices and signal­indicating
appliances for use with the control unit or indicates the particular devices and appliances
required and supplies any instructions necessary to complete their interconnection at the
installation.

The individual certifications indicate that wiring diagrams have been submitted with the control
unit, along with information regarding its intended application, and the unit has been tested with
representative actuating devices and signal­indicating devices to be used with it as an
interrelated assembly. Reference is made in the marking of the control unit to the wiring
diagram showing complete information except when the installation wiring diagram is secured to
the control unit.

http://productspec.ul.com/document.php?id=UOJZ.GuideInfo 1/7
5/18/2017 UL Product Spec

Identification of the control unit system type is indicated in the individual certifications as:

AUX ­ Auxiliary System

CS ­ Central Station System

L ­ Local System

LS ­ Local System with Shunt­type Connection to Master Box

P ­ Proprietary System

PPU ­ Protected Premises Unit

RS ­ Remote Station System

RU ­ Supervising Station Receiving Unit

System Control Unit with Emergency Voice Communication — A system control unit with
emergency voice communication consists of a control unit that employs a speaker system in
lieu of conventional general alarm­indicating circuits. The control unit may also have additional
provision for telephone communication by use of hand sets.

System Control Unit with Emergency Telephone Communication — A system control unit
with emergency telephone communication consists of a control unit with conventional general
alarm­indicating circuits and additionally employs telephone communication circuits to remote
telephone hand sets for emergency communication during a fire condition, usually for use by
fire department personnel.

The initiating device types that can be connected to the control unit system types indicated in
the individual certifications are:

A ­ Automatic Fire Alarm: thermostats, smoke detectors, etc.

CO ­ Carbon Monoxide Alarm: carbon monoxide detectors

M ­ Manual Fire Alarm: manually operated boxes

SS ­ Supervisory: gate valves, water­level switches, temperature switches, carbon
monoxide alarms, residential fire alarm control units, etc.

WF ­ Waterflow Alarm: waterflow switches

WSS ­ Watchman's Supervisory Service

The signaling types applicable for each control unit system type indicated in the individual
certifications are:

C ­ Coded

DAC ­ Digital Alarm Communicator

M ­ March Time

http://productspec.ul.com/document.php?id=UOJZ.GuideInfo 2/7
5/18/2017 UL Product Spec

MX ­ Multiplex

NC ­ Noncoded, Steady, Temporal 3 Pattern, etc.

OT ­ Other Transmission Technologies

PB ­ Performance­based Technologies

Rev Pol ­ Reverse Polarity

T4 ­ Temporal 4 Pattern

1W­RF ­ Radio Frequency (one­way private radio)

2W­RF ­ Radio Frequency (two­way private radio)

Carbon monoxide detectors interconnected with the fire alarm control unit system to produce a
carbon monoxide alarm are investigated to ANSI/UL 2075, "Gas and Vapor Detectors and
Sensors." Carbon monoxide alarm equipment interconnected with the fire alarm system to
produce a supervisory signal is investigated to ANSI/UL 2034 "Single and Multiple Station
Carbon Monoxide Alarms."

Where more than one control unit system type is indicated for a model number, such as L, LS,
AUX and RS (PPU), that particular model is suitable for all the indicated applications. The
change from one type to another may be made by deletion or addition of a panel or module
inside the control unit cabinet or revisions to operating software to provide the additional
function. In other cases a control unit may be suitable for a dual function without any panel
changes.

Authorities Having Jurisdiction should be consulted before installation or revision.

PRODUCT MARKINGS

Each complete product is marked to indicate its intended use. This consists of the word
"Commercial," followed by "Protected­Premises Control Unit" or "Supervising Station Control
Unit," consistent with the description in the individual certifications.

PRODUCT IDENTITY

One or more of the following product identities appears on the product: 

    Fire Alarm and Security Equipment (for products where the word "SECURITY" is included in
the Certification Mark)

    Fire Alarm and Security Equipment Subassembly (for products where the word "SECURITY"
is included in the Certification Mark)

    Fire Alarm Equipment

    Fire Alarm Equipment Subassembly

Some of these products are also certified under other Signaling and Energy Management,
http://productspec.ul.com/document.php?id=UOJZ.GuideInfo 3/7
5/18/2017 UL Product Spec

Information Technology or Telephone categories. When applicable, the product identity may
include "and Hospital Signaling and Nurse Call," "and General Signaling," "and Emergency
Signaling," "and Enclosed Energy Management," "and Information Technology" or "and
Telephone," as appropriate (e.g., Fire Alarm and Telephone Equipment).
 
The product identities may be abbreviated as follows:
    Type E (for Emergency Signaling Equipment)  
 
    Type E Subassembly (for Emergency Signaling Equipment Subassembly)
 
    Type EM (for Enclosed Energy Management Equipment)
 
    Type EM Subassembly (for Enclosed Energy Management Equipment Subassembly)
 
    Type F (for Fire Alarm Equipment)
 
    Type F Subassembly (for Fire Alarm Equipment Subassembly)
 
    Type G (for General Signaling Equipment)
 
    Type G Subassembly (for General Signaling Equipment Subassembly)
 
    Type HN (for Hospital Signaling and Nurse Call Equipment)
 
    Type HN Subassembly (for Hospital Signaling and Nurse Call Equipment Subassembly)
 
    Type IT (for Information Technology Equipment)
 
    Type IT Subassembly (for Information Technology Equipment Subassembly)
 
    Type S (for Security Equipment)
 
    Type S Subassembly (for Security Equipment Subassembly)
 
    Type T (for Telephone Equipment)
 
    Type T Subassembly (for Telephone Equipment Subassembly)
 
Where model numbers are indicated in the individual certifications, 100% of the manufacturer's
production for those models is required to be labeled. Where model numbers are not indicated,
the manufacturer is not obliged to label 100% of production. 
 
RELATED PRODUCTS

For additional information regarding central station systems, see Central­station Protective
Signaling Services (UUFX).

ADDITIONAL INFORMATION

http://productspec.ul.com/document.php?id=UOJZ.GuideInfo 4/7
5/18/2017 UL Product Spec

For additional information, see Signal and Fire Alarm Equipment and Services (SYKJ) and Fire
Protection Equipment (AAFP).

REQUIREMENTS

The basic standard used to investigate products in this category is ANSI/UL 864, "Control Units
and Accessories for Fire Alarm Systems" (9th ed., issued September 30, 2003, last revised
August 31, 2012; or 10th ed., issued December 1, 2014).

Some products covered under this category have also been investigated to ANSI/SIA CP­01
(2000, 2007, 2010 or 2014 ), "Control Panel Standard ­ Features for False Alarm Reduction."
See Control Panels, SIA False Alarm Reduction (AMTB).

UL MARK

The Certification Mark of UL on the product or on the smallest unit container in which the
product is packaged is the only method provided by UL to identify products manufactured under
its Certification and Follow­Up Service. The Certification Mark for these products includes the
UL symbol, the words "CERTIFIED," "SAFETY" and "SIGNALING," the geographic identifier(s),
and a file number.

The Certification Mark for fire alarm equipment may include the designation "___ of ___." The
first space is stamped with the number indicating the position that the panel occupies in the
series of panels constituting the fire alarm equipment. The second space is stamped with the
total number of units in the fire alarm equipment.

For products additionally investigated with respect to security applications, the word
"SECURITY" is included in the Certification Mark.

Additional Certification Markings

Products that have also been investigated to ANSI/SIA CP­01 (2000, 2007, 2010 or 2014 ) are
marked with one of the following statements:

ALSO CERTIFIED TO ANSI/SIA CP­01 (2000)

ALSO CERTIFIED TO ANSI/SIA CP­01 (2007)

ALSO CERTIFIED TO ANSI/SIA CP­01 (2010)

ALSO CERTIFIED TO ANSI/SIA CP­01 (2014)

Alternate UL Mark

The Signaling Listing Mark of UL on the product or on the smallest unit container in which the
product is packaged is the only method provided by UL to identify products manufactured under
its Listing and Follow­Up Service. The Signaling Listing Mark for these products includes the UL
symbol with the word "SIGNALING" above the UL symbol and the word "LISTED" below the UL
symbol (as illustrated in the Introduction of this Directory), a control number, and the product
name "Fire Alarm Equipment" or "Fire Alarm Subassembly."
http://productspec.ul.com/document.php?id=UOJZ.GuideInfo 5/7
5/18/2017 UL Product Spec

The Listing Mark for fire alarm equipment may include the designation "___ of ___." The first
space is stamped with the number indicating the position that the panel occupies in the series of
panels constituting the fire alarm equipment. The second space is stamped with the total
number of units in the fire alarm equipment.

When applicable, the Security Mark is also included. The combined Signaling/Security Listing
Mark consists of the Signaling Mark elements detailed above and the word "SECURITY" above
the UL symbol. The product name is "Fire Alarm and Security Equipment" or "Fire Alarm and
Security Subassembly."

Some of these products are also Listed under other Signaling and Energy Management,
Information Technology or Telephone categories. When applicable, the product name may
include "and Hospital Signaling and Nurse Call,""and General Signaling,""and Emergency
Signaling,""and Enclosed Energy Management,""and Information Technology" or "and
Telephone," as appropriate (e.g., "Fire Alarm and Telephone Equipment").

The product name may be abbreviated as follows: The word "Type:" followed by the appropriate
Type Code (as shown below), additionally followed by "Subassembly," as applicable.

Type Codes:

S ­ Security Equipment

F ­ Fire Alarm Equipment

HN ­ Hospital Signaling and Nurse Call Equipment

G ­ General Signaling Equipment

E ­ Emergency Signaling Equipment

EM ­ Enclosed Energy Management Equipment

IT ­ Information Technology Equipment

T ­ Telephone Equipment

Combination Listing/Classification Mark — A Listing Mark combined with a Classification
Mark is provided on products that have additionally been investigated to ANSI/SIA CP­01
(2000, 2007, 2010 or 2014 ). The combined Listing/Classification Mark consists of the Listing
Mark elements detailed above and one of the following statements as appropriate:

ALSO CLASSIFIED IN ACCORDANCE WITH ANSI/SIA CP­01­2000

ALSO CLASSIFIED IN ACCORDANCE WITH ANSI/SIA CP­01­2007

ALSO CLASSIFIED IN ACCORDANCE WITH ANSI/SIA CP­01­2010

ALSO CLASSIFIED IN ACCORDANCE WITH ANSI/SIA CP­01­2014

Where model numbers are indicated in the individual Listings, 100% of the manufacturer's
production for those models is required to be labeled. Where model numbers are not indicated,
the manufacturer is not obliged to label 100% of production.
http://productspec.ul.com/document.php?id=UOJZ.GuideInfo 6/7
5/18/2017 UL Product Spec

* * * * * * * * * * * * * * * * * * * * * * * * *

UL, in performing its functions in accordance with its objectives, does not assume or undertake
to discharge any responsibility of the manufacturer or any other party. UL shall not incur any
obligation or liability for any loss, expense or damages, including incidental or consequential
damages, arising out of or in connection with the use, interpretation of, or reliance upon this
Guide Information.

Last Updated on 2016­10­12

The appearance of a company's name or product in this database does not in itself assure that
products so identified have been manufactured under UL's Follow­Up Service. Only those
products bearing the UL Mark should be considered to be Certified and covered under UL's
Follow­Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory
subject to the following conditions: 1. The Guide Information, Assemblies, Constructions,
Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non­
misleading manner, without any manipulation of the data (or drawings). 2. The statement
"Reprinted from the Online Certifications Directory with permission from UL" must appear
adjacent to the extracted material. In addition, the reprinted material must include a copyright
notice in the following format: "© 2017 UL LLC".

Print   New Search

Other helpful UL resources

Request a Field Evaluation
UL and the UL logo are trademarks of UL LLC © 2017 All Rights Reserved.
Online Policies. About Cookies.

http://productspec.ul.com/document.php?id=UOJZ.GuideInfo 7/7

You might also like