PLATE LOAD TEST FOR DETERMINATION OF EV2 AS PER DIN 18134

Client RAIL VIKAS NIGAM LIMITED Report No 738/ESSAR/23-24


Date of Issue 16/12/2023
Date of Test 15/12/2023
Tested at On Site
Agency M/s. Surya Cons Private Limited Your Ref Verbal
Construction of road bed, Major, Minor Bridges and Service Buildings, Quarters, FOB, LC
Works, S &T Works, General electrical Works & ROB in connections with Railway Doubling
Name of Work Line Between Majorda (Including) at Km 91.500 to Vasco Da Gama (including) Km 108.52
Hospete Vasco-Da-Gama (Majorda To Sankval -Package-I) Doubling Project of South Western
Railway in South Goa District in Goa State
Test Location Chainage 93/100 to 94/000
Test Designation DIN 18134-300
Load Constant 250 kgf/div
First Loading Cycle
Load Gauge Load Normal Stress Dial Gauge Settlement
Loading Stage
Reading (Div.) in N in MPa Reading in mm
0 0 0.00 0.00 0 0.00
1 3 7354.99 0.08 24 0.24
2 6 14709.98 0.16 53 0.53
3 9 22064.96 0.25 69 0.69
4 12 29419.95 0.33 83 0.83
5 15 36774.94 0.41 93 0.93
6 18 44129.93 0.49 112 1.12
7 9 22064.96 0.25 101 1.01
8 5 12258.31 0.14 89 0.89
9 0 0.00 0.00 72 0.72
Second Loading Cycle
Load Gauge Load Normal Stress Dial Gauge Settlement
Loading Stage
Reading (Div.) in N in MPa Reading in mm
9 0 0.00 0.00 72 0.72
10 3 7354.99 0.08 93 0.93
11 6 14709.98 0.16 110 1.10
12 9 22064.96 0.25 123 1.23
13 12 29419.95 0.33 138 1.38
14 15 36774.94 0.41 153 1.53

For Essar Infratech.


Authorized by
FAZAL Digitally signed by
FAZAL ANKALGI

ANKALGI 17:45:25 +05'30'


Date: 2024.01.08

Er.Fazal Ankalgi
Director

Page 1 of 2
Normal Stress vs. Settlement Curve
Normal Stress in MPa
0.00 0.10 0.20 0.30 0.40 0.50 0.60
0.00

0.20

0.40

0.60
First Deformation Curve
Settlement in mm

0.80

1.00
Second Deformation Curve
1.20

1.40

1.60

1.80

Calculations
First Loading Cycle Second Loading Cycle
Maximum
0.49 0.49
Normal Stress
a0 0.0260 0.7307
a1 3.1387 2.3486
a2 -1.9786 -1.0161
Ev 103.7 121.6
Ev2/Ev1 1.17

Results: Second Deformation Modulus (Ev2) = 121.6 MPa


Statement:
1) This report should not be reproduced except in full without written approval of the laboratory.
2) The test results relate only to the items/samples tested. Endorsement of the product is not implied.
3) Any claim in legal disputes is not permitted.
4) We do not undertake any involvement in any type of litigation arising out of this report submitted by us.
5) Samples not drawn by this Lab.

For Essar Infratech.


Authorized by
Digitally signed
FAZAL by FAZAL
ANKALGI
ANKALGI Date: 2024.01.08
17:45:45 +05'30'

Er.Fazal Ankalgi
Director
Page 2 of 2