You are on page 1of 1

出口

三相异步电动机

编码 振动等级 频率
型号 平衡等级 电压
防护等级
标准 功率
极数
编号 电流
绝缘等级 驱动 转速
g n i t 工作制
a R / 非驱动
效率
功率因数
批号 重量

威乐 中国 水泵系统有限公司

入口
Anchor bolt 4-M20X300
Peripheral ramp iron
leveling

reinforced concrete base


Rubber Vibration
Pad

ground foundation

illustrate
1. The matching flange of the water pump shall comply with the GB/T 9119-2000 standard, and the vibration-damping
pedestal shall comply with the GBJ10-89 standard.
2. The foundation structure requires a level, and the foundation structure for the installation of vibration
damping pads needs to be raised by 50-100.
3. Secondary grouting is required after the anchor bolts are placed in the pre-embedded holes of the anchor bolts
Grouting is recommended between the bottom plate of the water pump and the concrete pedestal.
4. The weight of the pipeline cannot be pressed on the vibration-damping pedestal.
5. Adjust the level of vibration isolation equipment: move the position of the middle vibration damping pad to
make the center of gravity basically consistent.
6. The vibration-damping pad is directly placed between the vibration-isolation base and the foundation, and the
four corners can be jacked up by jacks during installation, and then
After placing the vibration-absorbing pad, if the weight of the vibration-isolation equipment is relatively light,
you can also use a crowbar to lift the vibration-isolation equipment.The four corner pads are wooden blocks, the height
of which is greater than that of the vibration damping pad, and the wooden blocks are removed after the vibration
Reserved anchor hole 4-140X140 damping pad is installed.
Depth 220 7. When installing and adjusting the level of vibration damping equipment, the rise or fall must be slow to
prevent damage to the vibration damping pad.
8. The weight of the damping table is about 1.5 times to 2 times the weight of the water pump, and the running
weight of the water pump is about the weight of the water pump About 1.5 times of that, the total weight of the water
pump installation is the running weight of the water pump + the weight of the vibration-damping pedestal.
9. This type of water pump uses 6 sets of SD43-4 rubber damping pads.