You are on page 1of 67

JM AEROFOIL

Fan Code: 80JM/20/8/3/...


BS 5750 Pt 1
EN 29001
ISO 9001
800 mm 830 rev/min 3 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2000 4000 6000 8000 10000 12000 14000

0 5000 10000 15000 20000


160
ISO 5801 16

V 0.6
Type D

140
14

0.5
120
81 12

82
100 79
0.4
10

85
79
78
80 32° 8
0.3

80
83 76
60 6
24°

0.2
78 77
40 4

16°

76 0.1
20 2

0 0 0.0
0 1 2 3 4 5 6 7

0.9
0.8
0.7
32°
0.6
0.5
0.4
24°
0.3
0.2 16°
0.1 8°
0.0
0 1 2 3 4 5 6 7

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð18 Ð7 Ð2 Ð9 Ð13 Ð21 Ð26 Ð35 Ð16 Ð7 Ð2 Ð9 Ð13 Ð20 Ð25 Ð32
8 8
Ð12 Ð7 Ð5 Ð6 Ð8 Ð15 Ð21 Ð30 Ð11 Ð7 Ð5 Ð6 Ð8 Ð14 Ð20 Ð29

Ð8 Ð6 Ð5 Ð11 Ð9 Ð12 Ð18 Ð26 Ð7 Ð6 Ð5 Ð11 Ð9 Ð12 Ð16 Ð23


16 16
Ð6 Ð5 Ð9 Ð10 Ð11 Ð13 Ð17 Ð24 Ð5 Ð5 Ð9 Ð10 Ð11 Ð12 Ð16 Ð22

Ð6 Ð8 Ð10 Ð10 Ð7 Ð10 Ð14 Ð20 Ð5 Ð8 Ð10 Ð10 Ð7 Ð10 Ð13 Ð18
24 Ð 36 24 Ð 36
Ð4 Ð6 Ð9 Ð12 Ð10 Ð13 Ð17 Ð25 Ð4 Ð6 Ð9 Ð12 Ð10 Ð12 Ð15 Ð22

SK11952 02/08/99
JM AEROFOIL
Fan Code: 80JM/20/8/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
800 mm 830 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2000 4000 6000 8000 10000 12000 14000 16000

0 5000 10000 15000 20000 25000


250 1.0
ISO 5801 25

V
Type D

200 0.8
20

83

150 0.6
81 84 15

86
82 82

100 32° 0.4


10
84
80 83

24°
84
82
50 5 0.2

16°
82

0 0 0.0
0 1 2 3 4 5 6 7 8

1.6
1.4
1.2
1.0 32°
0.8
0.6
24°
0.4
16°
0.2

0.0
0 1 2 3 4 5 6 7 8

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð12 Ð6 Ð4 Ð7 Ð11 Ð20 Ð26 Ð35 Ð10 Ð6 Ð4 Ð7 Ð11 Ð19 Ð25 Ð32
8 8
Ð12 Ð9 Ð5 Ð5 Ð8 Ð17 Ð22 Ð32 Ð11 Ð9 Ð5 Ð5 Ð8 Ð16 Ð22 Ð31

Ð13 Ð5 Ð4 Ð10 Ð12 Ð18 Ð26 Ð35 Ð12 Ð5 Ð4 Ð10 Ð12 Ð18 Ð25 Ð33
16 16
Ð6 Ð5 Ð8 Ð9 Ð10 Ð14 Ð20 Ð27 Ð6 Ð5 Ð8 Ð9 Ð10 Ð14 Ð19 Ð25

Ð10 Ð6 Ð5 Ð11 Ð9 Ð13 Ð17 Ð24 Ð9 Ð6 Ð5 Ð11 Ð9 Ð13 Ð16 Ð23


24 Ð 36 24 Ð 36
Ð6 Ð4 Ð8 Ð11 Ð11 Ð14 Ð18 Ð25 Ð5 Ð4 Ð8 Ð11 Ð11 Ð14 Ð17 Ð23

SK11953 02/08/99
JM AEROFOIL
Fan Code: 80JM/25/8/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
800 mm 830 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2000 4000 6000 8000 10000 12000 14000 16000

0 5000 10000 15000 20000 25000


180
ISO 5801
0.7
V
Type D
160

85 0.6
15

140
83

85 0.5
120 84

88
82
100 86 0.4
10

79 32°
80

83 0.3
81

60
24°
79
5 0.2

40

78 16°

0.1
20

0 0 0.0
0 1 2 3 4 5 6 7 8

1.2

1.0

0.8 32°
0.6

0.4 24°

0.2 16°

0.0
0 1 2 3 4 5 6 7 8

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð15 Ð13 Ð6 Ð3 Ð8 Ð15 Ð22 Ð32 Ð13 Ð13 Ð6 Ð4 Ð8 Ð15 Ð21 Ð30
8 8
Ð11 Ð13 Ð9 Ð5 Ð5 Ð10 Ð16 Ð24 Ð11 Ð13 Ð9 Ð7 Ð6 Ð9 Ð16 Ð23

Ð9 Ð9 Ð9 Ð4 Ð8 Ð13 Ð19 Ð28 Ð7 Ð9 Ð9 Ð5 Ð8 Ð13 Ð19 Ð26


16 16
Ð5 Ð6 Ð8 Ð10 Ð11 Ð13 Ð17 Ð23 Ð5 Ð5 Ð8 Ð10 Ð11 Ð13 Ð16 Ð21

Ð6 Ð7 Ð8 Ð7 Ð9 Ð13 Ð16 Ð22 Ð5 Ð7 Ð8 Ð8 Ð9 Ð13 Ð16 Ð21


24 Ð 36 24 Ð 36
Ð5 Ð7 Ð7 Ð8 Ð10 Ð14 Ð17 Ð23 Ð5 Ð7 Ð7 Ð9 Ð10 Ð14 Ð16 Ð21

SK11955 02/08/99
JM AEROFOIL
Fan Code: 80JM/25/8/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
800 mm 830 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2000 4000 6000 8000 10000 12000 14000 16000

0 5000 10000 15000 20000 25000


250 1.0
ISO 5801 25

V
Type D

200 0.8
20

83

82

150 84 0.6
15
83

82
85
86

100 82 0.4
32° 10

82
82

24°
82
50 5 0.2

83
16°

0 0 0.0
0 1 2 3 4 5 6 7 8

1.6
1.4
1.2
1.0
32°
0.8
0.6
24°
0.4
16°
0.2 8°
0.0
0 1 2 3 4 5 6 7 8

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð11 Ð8 Ð8 Ð4 Ð7 Ð14 Ð23 Ð33 Ð10 Ð7 Ð8 Ð6 Ð8 Ð14 Ð22 Ð31


8 8
Ð10 Ð9 Ð8 Ð6 Ð7 Ð8 Ð16 Ð25 Ð10 Ð8 Ð8 Ð8 Ð7 Ð7 Ð15 Ð24

Ð9 Ð10 Ð5 Ð6 Ð9 Ð15 Ð20 Ð28 Ð8 Ð10 Ð5 Ð6 Ð9 Ð15 Ð19 Ð26


16 16
Ð9 Ð7 Ð5 Ð8 Ð9 Ð13 Ð17 Ð25 Ð9 Ð7 Ð5 Ð9 Ð9 Ð12 Ð17 Ð23

Ð8 Ð8 Ð7 Ð6 Ð9 Ð12 Ð15 Ð21 Ð7 Ð8 Ð7 Ð7 Ð9 Ð12 Ð15 Ð20


24 Ð 36 24 Ð 36
Ð8 Ð7 Ð6 Ð7 Ð10 Ð13 Ð17 Ð23 Ð7 Ð6 Ð6 Ð8 Ð10 Ð13 Ð16 Ð21

SK11956 02/08/99
JM AEROFOIL
Fan Code: 80JM/20/6/3/...
BS 5750 Pt 1
EN 29001
ISO 9001
800 mm 1110 rev/min 3 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000

0 5000 10000 15000 20000 25000 30000


300 1.2
ISO 5801 30

V
Type D

250 1.0
25

90
200 0.8
20

92
88

97
150 89 0.6
87 15
32°

90
88 86

100 24° 0.4


10

84 86

16°
50 5 0.2
85

0 0 0.0
0 2 4 6 8 10

2.0

1.5 32°

1.0
24°

0.5
16°

0.0
0 2 4 6 8 10

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð19 Ð9 Ð2 Ð10 Ð12 Ð21 Ð25 Ð33 Ð17 Ð9 Ð2 Ð10 Ð12 Ð20 Ð24 Ð30
8 8
Ð10 Ð7 Ð7 Ð6 Ð7 Ð15 Ð19 Ð27 Ð8 Ð7 Ð7 Ð6 Ð7 Ð14 Ð18 Ð25

Ð7 Ð7 Ð5 Ð10 Ð9 Ð12 Ð16 Ð23 Ð6 Ð7 Ð5 Ð10 Ð9 Ð12 Ð15 Ð21


16 16
Ð5 Ð5 Ð10 Ð12 Ð10 Ð14 Ð17 Ð23 Ð4 Ð5 Ð10 Ð12 Ð10 Ð14 Ð15 Ð21

Ð6 Ð8 Ð9 Ð10 Ð8 Ð9 Ð13 Ð18 Ð4 Ð8 Ð9 Ð10 Ð8 Ð9 Ð12 Ð16


24 Ð 36 24 Ð 36
Ð4 Ð7 Ð9 Ð11 Ð11 Ð12 Ð16 Ð23 Ð3 Ð7 Ð9 Ð11 Ð11 Ð11 Ð15 Ð21

SK11957 02/08/99
JM AEROFOIL
Fan Code: 80JM/20/6/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
800 mm 1110 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000

0 5000 10000 15000 20000 25000 30000 35000 40000


400 1.6
ISO 5801 40

V
Type D

350 1.4
35

91
300 1.2
30

88 92
250 1.0
25

95
88 90
200 0.8
20

32°

91
87 91
150 15 0.6

24°
90
100 89 10 0.4

16°
88
50 5 0.2

0 0 0.0
0 2 4 6 8 10 12

3.5
3.0
2.5
32°
2.0
1.5
24°
1.0
16°
0.5

0.0
0 2 4 6 8 10 12

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð13 Ð6 Ð4 Ð8 Ð10 Ð20 Ð25 Ð31 Ð12 Ð6 Ð4 Ð8 Ð10 Ð19 Ð24 Ð29
8 8
Ð15 Ð10 Ð6 Ð5 Ð6 Ð16 Ð20 Ð29 Ð15 Ð9 Ð6 Ð5 Ð6 Ð16 Ð20 Ð27

Ð14 Ð5 Ð3 Ð10 Ð11 Ð18 Ð25 Ð31 Ð14 Ð5 Ð3 Ð10 Ð11 Ð18 Ð24 Ð30
16 16
Ð9 Ð6 Ð4 Ð11 Ð9 Ð15 Ð18 Ð24 Ð9 Ð6 Ð4 Ð11 Ð9 Ð14 Ð18 Ð23

Ð12 Ð6 Ð5 Ð9 Ð11 Ð12 Ð16 Ð23 Ð11 Ð6 Ð5 Ð9 Ð11 Ð12 Ð15 Ð22
24 Ð 36 24 Ð 36
Ð7 Ð4 Ð8 Ð11 Ð11 Ð12 Ð17 Ð23 Ð7 Ð4 Ð8 Ð11 Ð11 Ð12 Ð16 Ð21

SK11958 02/08/99
JM AEROFOIL
Fan Code: 80JM/25/6/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
800 mm 1110 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000

0 5000 10000 15000 20000 25000 30000


350 1.4
ISO 5801 35

V
Type D

300 1.2
30

91

250 90 1.0
25

91
91

200 0.8
94 20
89
92

150
87 32° 0.6
15

89
88

100 24° 10 0.4


87

86 16°
50 5 0.2

0 0 0.0
0 2 4 6 8 10

3.0

2.5

2.0
32°
1.5

1.0 24°

0.5 16°

0.0
0 2 4 6 8 10

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð15 Ð14 Ð8 Ð4 Ð6 Ð14 Ð21 Ð28 Ð14 Ð13 Ð8 Ð5 Ð6 Ð14 Ð20 Ð26
8 8
Ð10 Ð13 Ð10 Ð6 Ð4 Ð9 Ð15 Ð21 Ð10 Ð12 Ð10 Ð8 Ð5 Ð8 Ð14 Ð20

Ð8 Ð9 Ð10 Ð5 Ð6 Ð12 Ð18 Ð25 Ð7 Ð9 Ð10 Ð6 Ð6 Ð12 Ð17 Ð23


16 16
Ð5 Ð6 Ð8 Ð10 Ð11 Ð13 Ð17 Ð21 Ð5 Ð6 Ð8 Ð10 Ð11 Ð13 Ð16 Ð20

Ð6 Ð7 Ð8 Ð8 Ð8 Ð13 Ð16 Ð20 Ð5 Ð7 Ð8 Ð9 Ð8 Ð13 Ð15 Ð19


24 Ð 36 24 Ð 36
Ð5 Ð7 Ð8 Ð8 Ð9 Ð14 Ð17 Ð21 Ð5 Ð7 Ð8 Ð9 Ð9 Ð13 Ð16 Ð19

SK11960 02/08/99
JM AEROFOIL
Fan Code: 80JM/25/6/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
800 mm 1110 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000

0 5000 10000 15000 20000 25000 30000 35000 40000


450
ISO 5801

V
Type D
400
40

1.5

350

89

300
89 30

90

250 91 1.0

89
92
92
200
20

89
32°

150 89
89
0.5
24°
100 89 10

90
16°
50

0 0 0.0
0 2 4 6 8 10 12

4.0
3.5
3.0
2.5
32°
2.0
1.5
24°
1.0
16°
0.5 8°
0.0
0 2 4 6 8 10 12

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð11 Ð9 Ð9 Ð5 Ð6 Ð13 Ð21 Ð29 Ð9 Ð7 Ð9 Ð6 Ð6 Ð13 Ð20 Ð27


8 8
Ð10 Ð10 Ð8 Ð7 Ð7 Ð8 Ð13 Ð23 Ð10 Ð9 Ð8 Ð8 Ð7 Ð7 Ð13 Ð21

Ð9 Ð11 Ð6 Ð6 Ð8 Ð14 Ð19 Ð25 Ð7 Ð11 Ð6 Ð6 Ð8 Ð14 Ð18 Ð23


16 16
Ð8 Ð9 Ð5 Ð7 Ð8 Ð12 Ð16 Ð22 Ð8 Ð9 Ð5 Ð7 Ð8 Ð12 Ð16 Ð20

Ð7 Ð10 Ð7 Ð7 Ð7 Ð12 Ð15 Ð19 Ð6 Ð10 Ð7 Ð8 Ð8 Ð12 Ð14 Ð18


24 Ð 36 24 Ð 36
Ð7 Ð9 Ð6 Ð7 Ð9 Ð13 Ð16 Ð21 Ð6 Ð8 Ð6 Ð8 Ð9 Ð13 Ð15 Ð19

SK11961 02/08/99
JM AEROFOIL
Fan Code: 80JM/20/4/3/...
BS 5750 Pt 1
EN 29001
ISO 9001
800 mm 1730 rev/min 3 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000 30000

0 10000 20000 30000 40000 50000


700
ISO 5801 70

V
Type D
2.5
600
60

100
500 2.0
50

102
98

400
108 40
1.5
98
96
32°

300 30
99
100 94

24° 1.0

200 94 96 20

16°
0.5
95
100 10

0 0 0.0
0 2 4 6 8 10 12 14 16

8
7
6 32°
5
4
24°
3
2
16°
1 8°
0
0 2 4 6 8 10 12 14 16

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð17 Ð19 Ð8 Ð2 Ð11 Ð15 Ð22 Ð28 Ð15 Ð18 Ð7 Ð2 Ð10 Ð14 Ð21 Ð25
8 8
Ð8 Ð14 Ð8 Ð6 Ð7 Ð10 Ð16 Ð22 Ð7 Ð13 Ð8 Ð6 Ð7 Ð8 Ð15 Ð20

Ð7 Ð9 Ð7 Ð7 Ð12 Ð11 Ð13 Ð19 Ð6 Ð9 Ð7 Ð7 Ð12 Ð10 Ð11 Ð17


16 16
Ð3 Ð9 Ð7 Ð12 Ð13 Ð14 Ð16 Ð20 Ð3 Ð8 Ð7 Ð12 Ð12 Ð13 Ð14 Ð18

Ð7 Ð7 Ð9 Ð10 Ð11 Ð7 Ð12 Ð15 Ð6 Ð6 Ð9 Ð10 Ð11 Ð7 Ð10 Ð13


24 Ð 36 24 Ð 36
Ð5 Ð6 Ð8 Ð11 Ð14 Ð11 Ð15 Ð18 Ð4 Ð6 Ð8 Ð11 Ð14 Ð11 Ð14 Ð16

SK11962 02/08/99
JM AEROFOIL
Fan Code: 80JM/20/4/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
800 mm 1730 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000 30000 35000

0 10000 20000 30000 40000 50000 60000


1000 4.0
ISO 5801 100

V
Type D

3.5

800
80

101 3.0

98 102
2.5
600
60

105
98 99 2.0

32°

400 100
40
96 100 1.5

24°
100
98 1.0

200 20
16°
98
0.5

0 0 0.0
0 2 4 6 8 10 12 14 16 18

14
12
10
32°
8
6
24°
4
2 16°

0
0 2 4 6 8 10 12 14 16 18

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð22 Ð13 Ð7 Ð5 Ð9 Ð13 Ð21 Ð27 Ð20 Ð11 Ð6 Ð4 Ð8 Ð12 Ð19 Ð24
8 8
Ð21 Ð12 Ð9 Ð5 Ð6 Ð8 Ð17 Ð23 Ð21 Ð11 Ð9 Ð5 Ð5 Ð7 Ð17 Ð21

Ð20 Ð14 Ð6 Ð5 Ð11 Ð14 Ð19 Ð28 Ð18 Ð13 Ð4 Ð4 Ð10 Ð13 Ð17 Ð25
16 16
Ð12 Ð7 Ð5 Ð9 Ð10 Ð11 Ð15 Ð21 Ð11 Ð6 Ð5 Ð9 Ð10 Ð10 Ð14 Ð19

Ð14 Ð10 Ð7 Ð5 Ð12 Ð10 Ð14 Ð17 Ð13 Ð10 Ð7 Ð5 Ð12 Ð10 Ð14 Ð16
24 Ð 36 24 Ð 36
Ð10 Ð6 Ð5 Ð9 Ð12 Ð11 Ð15 Ð19 Ð9 Ð6 Ð5 Ð8 Ð12 Ð11 Ð14 Ð17

SK11963 02/08/99
JM AEROFOIL
Fan Code: 80JM/25/4/3/...
BS 5750 Pt 1
EN 29001
ISO 9001
800 mm 1730 rev/min 3 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000

0 10000 20000 30000 40000


600
ISO 5801 60

V
Type D

500 2.0
50

101
100

400
40
102 1.5
97

99
103

300
100 30
32°

98
100 1.0

200 96 24° 20

98

16° 0.5

100 94 10

0 0 0.0
0 2 4 6 8 10 12 14

5
32°
4

3
24°
2
16°
1

0
0 2 4 6 8 10 12 14

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð9 Ð11 Ð14 Ð6 Ð4 Ð10 Ð17 Ð23 Ð6 Ð10 Ð14 Ð8 Ð4 Ð10 Ð16 Ð20
8 8
Ð4 Ð7 Ð12 Ð10 Ð10 Ð12 Ð15 Ð17 Ð2 Ð6 Ð12 Ð11 Ð11 Ð11 Ð14 Ð15

Ð4 Ð6 Ð11 Ð10 Ð11 Ð13 Ð16 Ð19 Ð4 Ð6 Ð11 Ð11 Ð11 Ð12 Ð15 Ð16
16 16
Ð3 Ð5 Ð13 Ð13 Ð15 Ð17 Ð20 Ð22 Ð1 Ð5 Ð13 Ð14 Ð15 Ð16 Ð18 Ð19

Ð5 Ð6 Ð9 Ð10 Ð11 Ð13 Ð17 Ð20 Ð4 Ð5 Ð9 Ð10 Ð12 Ð13 Ð15 Ð18
24 Ð 32 24 Ð 32
Ð5 Ð6 Ð10 Ð10 Ð11 Ð12 Ð16 Ð18 Ð3 Ð5 Ð10 Ð11 Ð11 Ð12 Ð14 Ð16

SK11964 02/08/99
JM AEROFOIL
Fan Code: 80JM/25/4/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
800 mm 1730 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000 30000

0 10000 20000 30000 40000 50000


800
ISO 5801 80

V 3.0
Type D

700
70

101
2.5
600 100
60

101
101
500 2.0
50
104
99

102

400
40
97 32° 1.5

99
98
300 30

24° 1.0
97
200 20

96 16°
0.5
100 10

0 0 0.0
0 2 4 6 8 10 12 14 16

12

10

8
32°
6

4 24°
2 16°

0
0 2 4 6 8 10 12 14 16

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð17 Ð15 Ð14 Ð6 Ð3 Ð8 Ð16 Ð23 Ð16 Ð13 Ð13 Ð8 Ð4 Ð8 Ð15 Ð20
8 8
Ð15 Ð11 Ð13 Ð9 Ð5 Ð5 Ð11 Ð16 Ð15 Ð10 Ð13 Ð10 Ð6 Ð4 Ð10 Ð15

Ð12 Ð9 Ð9 Ð9 Ð5 Ð8 Ð14 Ð20 Ð11 Ð9 Ð9 Ð9 Ð5 Ð8 Ð13 Ð18


16 16
Ð11 Ð5 Ð6 Ð9 Ð10 Ð12 Ð14 Ð18 Ð10 Ð5 Ð6 Ð9 Ð10 Ð11 Ð13 Ð16

Ð7 Ð7 Ð8 Ð9 Ð8 Ð10 Ð15 Ð17 Ð6 Ð7 Ð8 Ð9 Ð8 Ð10 Ð14 Ð16


24 Ð 36 24 Ð 36
Ð7 Ð6 Ð8 Ð8 Ð9 Ð11 Ð15 Ð18 Ð7 Ð6 Ð8 Ð9 Ð9 Ð11 Ð14 Ð16

SK11965 02/08/99
JM AEROFOIL
Fan Code: 80JM/25/4/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
800 mm 1730 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000 30000 35000

0 10000 20000 30000 40000 50000 60000


1200
ISO 5801 120

V
Type D

1000 4
100

800 100
80
3
100

101

102
600
60

99
102
103 2

99
32°
400 40
100
99

24°
99 1

200 20

100
16°

0 0 0
0 2 4 6 8 10 12 14 16 18

16
14
12
10
8 32°

6
24°
4
2 16°

0
0 2 4 6 8 10 12 14 16 18

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð10 Ð11 Ð9 Ð8 Ð5 Ð8 Ð15 Ð24 Ð9 Ð11 Ð7 Ð9 Ð5 Ð7 Ð14 Ð22


8 8
Ð11 Ð11 Ð10 Ð8 Ð7 Ð8 Ð9 Ð17 Ð10 Ð11 Ð9 Ð9 Ð7 Ð6 Ð8 Ð15

Ð7 Ð10 Ð10 Ð6 Ð7 Ð10 Ð16 Ð21 Ð6 Ð10 Ð10 Ð6 Ð7 Ð10 Ð15 Ð19
16 16
Ð7 Ð10 Ð8 Ð6 Ð9 Ð10 Ð14 Ð18 Ð6 Ð10 Ð8 Ð7 Ð9 Ð9 Ð13 Ð17

Ð4 Ð11 Ð11 Ð9 Ð8 Ð11 Ð14 Ð17 Ð3 Ð11 Ð10 Ð9 Ð8 Ð11 Ð13 Ð16
24 Ð 36 24 Ð 36
Ð6 Ð10 Ð8 Ð7 Ð9 Ð11 Ð15 Ð18 Ð5 Ð10 Ð8 Ð8 Ð9 Ð11 Ð14 Ð16

SK11966 02/08/99
JM AEROFOIL
Fan Code: 90JM/25/8/3/...
BS 5750 Pt 1
EN 29001
ISO 9001
900 mm 830 rev/min 3 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000

0 5000 10000 15000 20000 25000 30000


140
ISO 5801 14

V
Type D
0.5
120
12
89
87

90

100 0.4
10

82 87 91

32°

80
8
86 0.3
87
83

24°
60 6

80
83 0.2

40 4
16°

80
0.1

20 2

0 0 0.0
0 1 2 3 4 5 6 7 8 9

1.0
32°
0.8

0.6
24°
0.4

0.2 16°


0.0
0 1 2 3 4 5 6 7 8 9

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð14 Ð14 Ð6 Ð3 Ð9 Ð14 Ð21 Ð30 Ð12 Ð13 Ð6 Ð3 Ð9 Ð13 Ð20 Ð27
8 8
Ð6 Ð10 Ð8 Ð7 Ð8 Ð11 Ð15 Ð22 Ð5 Ð10 Ð8 Ð7 Ð8 Ð9 Ð15 Ð20

Ð5 Ð9 Ð8 Ð8 Ð9 Ð12 Ð16 Ð21 Ð4 Ð9 Ð8 Ð8 Ð9 Ð12 Ð15 Ð19


16 16
Ð3 Ð8 Ð9 Ð9 Ð11 Ð14 Ð17 Ð23 Ð3 Ð8 Ð9 Ð9 Ð11 Ð13 Ð16 Ð21

Ð4 Ð7 Ð8 Ð10 Ð11 Ð14 Ð17 Ð22 Ð3 Ð7 Ð8 Ð10 Ð11 Ð14 Ð16 Ð20
24 Ð 32 24 Ð 32
Ð3 Ð8 Ð9 Ð10 Ð11 Ð13 Ð16 Ð20 Ð2 Ð8 Ð9 Ð10 Ð11 Ð12 Ð15 Ð18

SK11968 02/08/99
JM AEROFOIL
Fan Code: 90JM/25/8/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
900 mm 830 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000

0 5000 10000 15000 20000 25000 30000


250 1.0
ISO 5801 25

V
Type D

200 0.8
20

90

88

90
150 0.6
15
88

88
89 91

32°
84
100 10 0.4
88

85

24°

85

50 5 0.2
16°
83

0 0 0.0
0 2 4 6 8 10

1.8
1.6
1.4 32°
1.2
1.0
0.8
24°
0.6
0.4
16°
0.2

0.0
0 2 4 6 8 10

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð17 Ð14 Ð6 Ð3 Ð8 Ð13 Ð22 Ð31 Ð15 Ð13 Ð6 Ð3 Ð8 Ð13 Ð21 Ð29
8 8
Ð11 Ð12 Ð11 Ð5 Ð5 Ð8 Ð16 Ð24 Ð11 Ð12 Ð11 Ð5 Ð5 Ð7 Ð16 Ð23

Ð13 Ð12 Ð7 Ð3 Ð8 Ð12 Ð19 Ð29 Ð12 Ð12 Ð7 Ð3 Ð8 Ð12 Ð18 Ð27
16 16
Ð7 Ð7 Ð8 Ð7 Ð9 Ð11 Ð16 Ð24 Ð6 Ð7 Ð8 Ð7 Ð9 Ð11 Ð15 Ð22

Ð7 Ð8 Ð7 Ð7 Ð8 Ð12 Ð16 Ð21 Ð6 Ð8 Ð7 Ð7 Ð8 Ð12 Ð15 Ð20


24 Ð 32 24 Ð 32
Ð5 Ð7 Ð8 Ð8 Ð10 Ð12 Ð16 Ð21 Ð4 Ð7 Ð8 Ð8 Ð10 Ð12 Ð15 Ð20

SK11969 02/08/99
JM AEROFOIL
Fan Code: 90JM/25/8/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
900 mm 830 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000

0 5000 10000 15000 20000 25000 30000 35000 40000


300 1.2
ISO 5801 30

V
Type D

250 1.0
25
89

87

200 0.8
90 20

89

88
88
92
150 0.6
15

86 32°

89

100 86
10 0.4

24°
86

50 5 0.2
87 16°

0 0 0.0
0 2 4 6 8 10 12

3.0

2.5

2.0
32°
1.5

1.0 24°

0.5 16°

0.0
0 2 4 6 8 10 12

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð16 Ð10 Ð8 Ð4 Ð6 Ð11 Ð20 Ð32 Ð15 Ð8 Ð8 Ð4 Ð6 Ð11 Ð19 Ð30


8 8
Ð14 Ð8 Ð8 Ð7 Ð6 Ð8 Ð15 Ð25 Ð14 Ð8 Ð8 Ð7 Ð6 Ð7 Ð14 Ð23

Ð12 Ð10 Ð7 Ð5 Ð7 Ð11 Ð17 Ð25 Ð11 Ð10 Ð7 Ð5 Ð7 Ð11 Ð17 Ð24
16 16
Ð9 Ð7 Ð7 Ð7 Ð8 Ð11 Ð16 Ð22 Ð9 Ð7 Ð7 Ð7 Ð8 Ð11 Ð15 Ð21

Ð8 Ð8 Ð7 Ð7 Ð8 Ð11 Ð15 Ð20 Ð7 Ð8 Ð7 Ð7 Ð8 Ð11 Ð14 Ð19


24 Ð 36 24 Ð 36
Ð7 Ð7 Ð7 Ð8 Ð9 Ð12 Ð16 Ð21 Ð6 Ð7 Ð7 Ð8 Ð9 Ð12 Ð15 Ð20

SK11970 02/08/99
JM AEROFOIL
Fan Code: 90JM/25/6/3/...
BS 5750 Pt 1
EN 29001
ISO 9001
900 mm 1110 rev/min 3 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000

0 5000 10000 15000 20000 25000 30000 35000 40000


250 1.0
ISO 5801 25

V
Type D

96
200 94
0.8
20
96

90 93 98

150 32°
0.6
15

92 94
92

24°

100 10 0.4
88
93

16°

50 87 0.2
5

0 0 0.0
0 2 4 6 8 10 12

2.5

2.0 32°

1.5
24°
1.0

0.5 16°


0.0
0 2 4 6 8 10 12

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð13 Ð15 Ð8 Ð3 Ð6 Ð12 Ð20 Ð26 Ð11 Ð14 Ð8 Ð3 Ð6 Ð12 Ð18 Ð24
8 8
Ð6 Ð10 Ð8 Ð8 Ð8 Ð11 Ð15 Ð20 Ð4 Ð10 Ð8 Ð8 Ð8 Ð9 Ð14 Ð18

Ð4 Ð9 Ð9 Ð9 Ð9 Ð11 Ð15 Ð20 Ð3 Ð9 Ð9 Ð9 Ð9 Ð11 Ð14 Ð17


16 16
Ð3 Ð9 Ð10 Ð10 Ð11 Ð13 Ð16 Ð22 Ð3 Ð9 Ð10 Ð10 Ð11 Ð13 Ð15 Ð20

Ð4 Ð7 Ð9 Ð10 Ð11 Ð13 Ð17 Ð21 Ð3 Ð7 Ð9 Ð10 Ð11 Ð13 Ð16 Ð19
24 Ð 32 24 Ð 32
Ð3 Ð9 Ð10 Ð11 Ð11 Ð13 Ð16 Ð19 Ð2 Ð9 Ð10 Ð11 Ð11 Ð12 Ð14 Ð17

SK11971 02/08/99
JM AEROFOIL
Fan Code: 90JM/25/6/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
900 mm 1110 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000

0 10000 20000 30000 40000


400 1.6
ISO 5801 40

V
Type D

350 1.4
35

96

300 94 1.2
30

96

250 94 1.0
25

94
95 97

200 32° 20 0.8

91

95

150 91 15 0.6

24°

91

100 10 0.4

16°
89

50 5 0.2

0 0 0.0
0 2 4 6 8 10 12 14

4.0
3.5
32°
3.0
2.5
2.0
24°
1.5
1.0
16°
0.5

0.0
0 2 4 6 8 10 12 14

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð15 Ð15 Ð8 Ð4 Ð6 Ð12 Ð20 Ð28 Ð14 Ð14 Ð8 Ð4 Ð6 Ð12 Ð20 Ð26
8 8
Ð10 Ð13 Ð10 Ð6 Ð5 Ð7 Ð15 Ð21 Ð10 Ð13 Ð10 Ð6 Ð5 Ð6 Ð15 Ð20

Ð11 Ð12 Ð9 Ð4 Ð6 Ð11 Ð18 Ð26 Ð10 Ð12 Ð9 Ð4 Ð6 Ð11 Ð17 Ð24
16 16
Ð6 Ð8 Ð8 Ð8 Ð9 Ð11 Ð15 Ð22 Ð5 Ð8 Ð8 Ð8 Ð9 Ð10 Ð15 Ð20

Ð6 Ð9 Ð8 Ð7 Ð8 Ð11 Ð15 Ð19 Ð5 Ð9 Ð8 Ð7 Ð8 Ð11 Ð15 Ð18


24 Ð 32 24 Ð 32
Ð5 Ð8 Ð8 Ð9 Ð9 Ð12 Ð16 Ð19 Ð4 Ð8 Ð8 Ð9 Ð9 Ð12 Ð15 Ð18

SK11972 02/08/99
JM AEROFOIL
Fan Code: 90JM/25/6/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
900 mm 1110 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000 30000

0 10000 20000 30000 40000 50000


600
ISO 5801 60

V
Type D

500 2.0
50

95

400
94 40
1.5

96

94
300 94 30
94
98

1.0
92 32°

200 95
20
92

24°
92
0.5

100 10
92 16°

0 0 0.0
0 2 4 6 8 10 12 14 16

7
6
5
4 32°

3
24°
2
1 16°

0
0 2 4 6 8 10 12 14 16

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð16 Ð11 Ð10 Ð5 Ð5 Ð9 Ð18 Ð28 Ð14 Ð9 Ð9 Ð5 Ð5 Ð9 Ð18 Ð25


8 8
Ð14 Ð10 Ð8 Ð7 Ð6 Ð7 Ð13 Ð22 Ð14 Ð9 Ð8 Ð7 Ð6 Ð6 Ð13 Ð20

Ð11 Ð12 Ð8 Ð5 Ð6 Ð10 Ð16 Ð22 Ð10 Ð12 Ð8 Ð5 Ð6 Ð10 Ð15 Ð20
16 16
Ð9 Ð9 Ð6 Ð7 Ð7 Ð10 Ð14 Ð20 Ð8 Ð9 Ð6 Ð7 Ð7 Ð10 Ð14 Ð18

Ð8 Ð10 Ð7 Ð7 Ð8 Ð10 Ð14 Ð18 Ð6 Ð10 Ð7 Ð7 Ð8 Ð10 Ð13 Ð17


24 Ð 36 24 Ð 36
Ð6 Ð8 Ð7 Ð8 Ð9 Ð12 Ð15 Ð19 Ð6 Ð8 Ð6 Ð8 Ð9 Ð12 Ð14 Ð18

SK11973 02/08/99
JM AEROFOIL
Fan Code: 90JM/25/4/3/...
BS 5750 Pt 1
EN 29001
ISO 9001
900 mm 1760 rev/min 3 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000 30000 35000

0 10000 20000 30000 40000 50000 60000


700
ISO 5801 70

V
Type D
2.5
600
60

106
105
500 2.0
50
107

101 104 109


400
40
32°
1.5

102 104
103
300 30
24°

1.0
98
105
200 20

16°

97
0.5

100 10

0 0 0.0
0 2 4 6 8 10 12 14 16 18

10

8 32°

6
24°
4

2 16°


0
0 2 4 6 8 10 12 14 16 18

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð14 Ð15 Ð15 Ð6 Ð4 Ð10 Ð15 Ð22 Ð11 Ð14 Ð14 Ð6 Ð3 Ð9 Ð14 Ð19
8 8
Ð8 Ð9 Ð13 Ð10 Ð9 Ð11 Ð13 Ð18 Ð6 Ð7 Ð11 Ð8 Ð8 Ð8 Ð11 Ð15

Ð6 Ð9 Ð12 Ð11 Ð11 Ð12 Ð15 Ð19 Ð4 Ð7 Ð10 Ð10 Ð9 Ð11 Ð12 Ð15
16 16
Ð6 Ð7 Ð12 Ð12 Ð13 Ð15 Ð18 Ð20 Ð4 Ð5 Ð10 Ð10 Ð11 Ð13 Ð14 Ð16

Ð7 Ð5 Ð9 Ð9 Ð12 Ð13 Ð15 Ð19 Ð6 Ð5 Ð8 Ð9 Ð11 Ð12 Ð14 Ð17


24 Ð 32 24 Ð 32
Ð6 Ð5 Ð10 Ð10 Ð12 Ð12 Ð15 Ð18 Ð5 Ð4 Ð10 Ð10 Ð12 Ð11 Ð13 Ð15

SK11975 02/08/99
JM AEROFOIL
Fan Code: 90JM/25/4/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
900 mm 1760 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000

0 20000 40000 60000 80000


1000 4.0
ISO 5801 100

V
Type D

3.5

800 107
80

104 3.0

107

104
2.5
600
104 60
105 108

32° 2.0

101

106
400 40
101 1.5

24°

102

1.0

200 16° 20
100

0.5

0 0 0.0
0 5 10 15 20 25

16
14
32°
12
10
8
24°
6
4
16°
2

0
0 5 10 15 20 25

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð15 Ð18 Ð14 Ð6 Ð4 Ð9 Ð15 Ð23 Ð13 Ð16 Ð13 Ð6 Ð4 Ð8 Ð14 Ð20
8 8
Ð12 Ð14 Ð14 Ð14 Ð7 Ð8 Ð12 Ð19 Ð10 Ð12 Ð12 Ð12 Ð5 Ð5 Ð9 Ð16

Ð11 Ð14 Ð12 Ð8 Ð4 Ð9 Ð14 Ð20 Ð9 Ð14 Ð12 Ð7 Ð4 Ð9 Ð13 Ð18


16 16
Ð8 Ð9 Ð9 Ð10 Ð9 Ð11 Ð14 Ð18 Ð6 Ð8 Ð8 Ð9 Ð8 Ð10 Ð12 Ð16

Ð7 Ð8 Ð9 Ð8 Ð8 Ð10 Ð13 Ð17 Ð6 Ð8 Ð9 Ð8 Ð8 Ð9 Ð13 Ð16


24 Ð 32 24 Ð 32
Ð6 Ð7 Ð9 Ð9 Ð10 Ð11 Ð14 Ð18 Ð6 Ð6 Ð8 Ð9 Ð10 Ð11 Ð13 Ð16

SK11976 02/08/99
JM AEROFOIL
Fan Code: 90JM/25/4/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
900 mm 1760 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D - Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.
0 10000 20000 30000 40000 50000
0 20000 40000 60000 80000
1400
ISO 5801 140
V
Type D
5
1200 120

106
1000 104 100 4

106
800 105 80
104 3
104 109
600 102 32° 60
105 2
102
400 40
24°
103
1
200 102 16° 20


0 0 0
0 5 10 15 20 25
30
25
20
15 32°
10 24°
5 16°

0
0 5 10 15 20 25

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.
Inlet Levels Outlet Levels
Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k Angle 63 125 250 500 1k 2k 4k 8k
8 - 16 - 17 - 11 -9 -5 -7 - 13 - 21 8 - 14 - 16 -9 -8 -4 -6 - 12 - 18
- 14 - 15 -9 -9 -7 -7 -9 - 15 - 14 - 14 -8 -8 -7 -5 -8 - 14
16 - 12 - 13 - 11 -8 -6 -8 - 13 - 19 16 - 10 - 12 - 10 -8 -5 -7 - 11 - 16
-9 - 11 -8 -8 -9 -9 - 13 - 17 -8 - 10 -7 -7 -8 -8 - 11 - 15
24 - 36 -7 - 10 - 10 -9 -8 -9 - 13 - 16 24 - 36 -5 - 10 -9 -8 -8 -9 - 11 - 15
-7 -8 -8 -8 -9 - 11 - 14 - 17 -6 -8 -8 -8 -9 - 10 - 13 - 15

SK12470 06/02/01
JM AEROFOIL
Fan Code: 100JM/25/8/3/...
BS 5750 Pt 1
EN 29001
ISO 9001
1000 mm 830 rev/min 3 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000

0 5000 10000 15000 20000 25000 30000 35000 40000


160
ISO 5801 16

V 0.6
Type D

140
14
90
87
93
0.5
120
12
98

89
32°
84
100 0.4
10

92

87 84
80 24° 8
0.3

60 86 6
81

0.2
16°

40 4
82

0.1

20 2

0 0 0.0
0 2 4 6 8 10 12

1.6
1.4 32°
1.2
1.0
0.8 24°

0.6
0.4 16°
0.2

0.0
0 2 4 6 8 10 12

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð15 Ð14 Ð6 Ð3 Ð8 Ð12 Ð21 Ð29 Ð13 Ð14 Ð6 Ð3 Ð8 Ð12 Ð20 Ð26
8 8
Ð5 Ð11 Ð9 Ð7 Ð8 Ð10 Ð17 Ð24 Ð5 Ð11 Ð9 Ð7 Ð8 Ð9 Ð16 Ð22

Ð5 Ð9 Ð9 Ð7 Ð9 Ð10 Ð16 Ð22 Ð4 Ð9 Ð9 Ð7 Ð9 Ð10 Ð15 Ð19


16 16
Ð3 Ð9 Ð10 Ð9 Ð11 Ð13 Ð17 Ð25 Ð3 Ð9 Ð10 Ð9 Ð11 Ð12 Ð16 Ð22

Ð4 Ð8 Ð9 Ð12 Ð12 Ð13 Ð17 Ð21 Ð3 Ð8 Ð9 Ð12 Ð12 Ð13 Ð16 Ð19
24 Ð 32 24 Ð 32
Ð3 Ð9 Ð10 Ð12 Ð11 Ð13 Ð16 Ð20 Ð2 Ð9 Ð10 Ð12 Ð11 Ð12 Ð15 Ð17

SK11978 03/08/99
JM AEROFOIL
Fan Code: 100JM/25/8/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1000 mm 830 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000

0 10000 20000 30000 40000


300 1.2
ISO 5801 30

V
Type D

250 1.0
25

92

200 0.8
89 20
92

90
89 92
150 0.6
15
90
32°

87
90

100 10 0.4
87 24°

87

16°
50 85 5 0.2

0 0 0.0
0 2 4 6 8 10 12 14

3.0

2.5
32°
2.0

1.5
24°
1.0

0.5 16°

0.0
0 2 4 6 8 10 12 14

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð18 Ð14 Ð6 Ð4 Ð8 Ð11 Ð22 Ð31 Ð16 Ð14 Ð6 Ð4 Ð8 Ð11 Ð21 Ð29
8 8
Ð11 Ð11 Ð13 Ð6 Ð5 Ð7 Ð17 Ð25 Ð11 Ð11 Ð13 Ð6 Ð5 Ð6 Ð17 Ð23

Ð16 Ð15 Ð7 Ð3 Ð8 Ð12 Ð19 Ð30 Ð15 Ð15 Ð7 Ð3 Ð8 Ð12 Ð18 Ð28
16 16
Ð8 Ð9 Ð9 Ð6 Ð8 Ð10 Ð16 Ð25 Ð7 Ð9 Ð9 Ð6 Ð8 Ð10 Ð15 Ð24

Ð7 Ð9 Ð7 Ð7 Ð8 Ð11 Ð16 Ð21 Ð6 Ð9 Ð7 Ð7 Ð8 Ð11 Ð15 Ð20


24 Ð 32 24 Ð 32
Ð5 Ð8 Ð8 Ð9 Ð9 Ð11 Ð16 Ð20 Ð4 Ð8 Ð8 Ð9 Ð9 Ð11 Ð15 Ð18

SK11979 03/08/99
JM AEROFOIL
Fan Code: 100JM/25/8/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1000 mm 830 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000 30000

0 10000 20000 30000 40000 50000


350 1.4
ISO 5801 35

V
Type D

300 1.2
30

92

250 1.0
25

89 92

200 0.8
20

91 95
90

32°
150 15 0.6
92
87 91

24°
100 88 10 0.4

88

16°
50 87 5 0.2

0 0 0.0
0 2 4 6 8 10 12 14 16

4.5
4.0
3.5
3.0 32°
2.5
2.0
1.5 24°
1.0 16°
0.5 8°
0.0
0 2 4 6 8 10 12 14 16

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð22 Ð12 Ð9 Ð4 Ð6 Ð9 Ð17 Ð30 Ð21 Ð11 Ð9 Ð4 Ð6 Ð9 Ð17 Ð28


8 8
Ð18 Ð8 Ð9 Ð7 Ð5 Ð8 Ð14 Ð24 Ð19 Ð7 Ð9 Ð7 Ð5 Ð6 Ð13 Ð23

Ð15 Ð12 Ð11 Ð4 Ð5 Ð9 Ð16 Ð23 Ð14 Ð12 Ð11 Ð4 Ð5 Ð9 Ð15 Ð22
16 16
Ð10 Ð7 Ð8 Ð7 Ð7 Ð10 Ð14 Ð20 Ð10 Ð7 Ð8 Ð7 Ð7 Ð10 Ð14 Ð18

Ð8 Ð8 Ð8 Ð8 Ð7 Ð10 Ð14 Ð19 Ð7 Ð8 Ð8 Ð8 Ð7 Ð10 Ð14 Ð18


24 Ð 36 24 Ð 36
Ð6 Ð7 Ð8 Ð9 Ð9 Ð11 Ð16 Ð20 Ð5 Ð6 Ð8 Ð9 Ð9 Ð11 Ð15 Ð18

SK11980 03/08/99
JM AEROFOIL
Fan Code: 100JM/25/6/3/...
BS 5750 Pt 1
EN 29001
ISO 9001
1000 mm 1170 rev/min 3 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000 30000 35000

0 10000 20000 30000 40000 50000 60000


350 1.4
ISO 5801 35

V
Type D

300 1.2
30

101
99
250 103 1.0
25

106
99
32°
97
200 0.8
20

100

95 100
24°
150 15 0.6

106
92

100 10 0.4
16°

92

50 5 0.2

0 0 0.0
0 2 4 6 8 10 12 14 16 18

4.5
4.0 32°
3.5
3.0
2.5 24°
2.0
1.5
1.0 16°
0.5 8°
0.0
0 2 4 6 8 10 12 14 16 18

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð10 Ð16 Ð7 Ð5 Ð6 Ð11 Ð20 Ð26 Ð9 Ð15 Ð7 Ð5 Ð6 Ð10 Ð19 Ð23


8 8
Ð3 Ð10 Ð10 Ð10 Ð9 Ð11 Ð18 Ð23 Ð3 Ð10 Ð10 Ð10 Ð9 Ð10 Ð17 Ð21

Ð2 Ð11 Ð12 Ð11 Ð11 Ð12 Ð18 Ð23 Ð1 Ð11 Ð12 Ð11 Ð11 Ð12 Ð17 Ð21
16 16
Ð2 Ð9 Ð13 Ð11 Ð13 Ð14 Ð19 Ð26 Ð1 Ð9 Ð13 Ð11 Ð13 Ð14 Ð18 Ð23

Ð4 Ð8 Ð9 Ð11 Ð12 Ð13 Ð16 Ð19 Ð3 Ð7 Ð9 Ð11 Ð12 Ð13 Ð15 Ð17
24 Ð 32 24 Ð 32
Ð2 Ð9 Ð11 Ð12 Ð12 Ð13 Ð16 Ð18 Ð1 Ð9 Ð11 Ð12 Ð12 Ð13 Ð15 Ð16

SK11984 03/08/99
JM AEROFOIL
Fan Code: 100JM/25/6/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1000 mm 1170 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000 30000 35000 40000

0 10000 20000 30000 40000 50000 60000


500 2.0
ISO 5801 50

V
Type D

102

400
98 40

102 1.5

99
100 104
300
30
98
32°

1.0
97
102

200 20
96 24°

98

0.5
16°
100 94 10

0 0 0.0
0 5 10 15 20

8
7
6 32°

5
4
3 24°

2
16°
1

0
0 5 10 15 20

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð14 Ð16 Ð7 Ð4 Ð7 Ð10 Ð22 Ð28 Ð13 Ð14 Ð7 Ð4 Ð7 Ð10 Ð21 Ð26
8 8
Ð9 Ð16 Ð13 Ð3 Ð9 Ð9 Ð19 Ð25 Ð9 Ð16 Ð13 Ð3 Ð9 Ð7 Ð19 Ð23

Ð11 Ð17 Ð7 Ð5 Ð6 Ð10 Ð18 Ð28 Ð10 Ð17 Ð7 Ð5 Ð6 Ð10 Ð18 Ð26
16 16
Ð5 Ð12 Ð10 Ð6 Ð9 Ð10 Ð16 Ð25 Ð4 Ð12 Ð10 Ð6 Ð9 Ð10 Ð15 Ð23

Ð7 Ð10 Ð8 Ð7 Ð8 Ð10 Ð15 Ð18 Ð6 Ð10 Ð8 Ð7 Ð8 Ð10 Ð14 Ð17


24 Ð 32 24 Ð 32
Ð4 Ð9 Ð8 Ð10 Ð10 Ð11 Ð15 Ð18 Ð4 Ð8 Ð8 Ð10 Ð10 Ð11 Ð14 Ð16

SK11985 03/08/99
JM AEROFOIL
Fan Code: 100JM/25/6/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1000 mm 1170 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000

0 20000 40000 60000 80000


700
ISO 5801 70

V
Type D
2.5
600
60

101

500 2.0
50

98 102

400
40

105 1.5
99 100

32°
300 30
99
96 101
1.0

24°
200 96 20
97

0.5
16°
100 96 10

0 0 0.0
0 5 10 15 20 25

14
12
10
8 32°

6
4 24°

2 16°

0
0 5 10 15 20 25

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð21 Ð14 Ð10 Ð5 Ð5 Ð7 Ð16 Ð26 Ð20 Ð12 Ð10 Ð5 Ð5 Ð7 Ð16 Ð24
8 8
Ð18 Ð9 Ð9 Ð8 Ð6 Ð6 Ð13 Ð21 Ð18 Ð8 Ð9 Ð8 Ð6 Ð5 Ð13 Ð20

Ð15 Ð14 Ð11 Ð5 Ð5 Ð8 Ð14 Ð20 Ð14 Ð14 Ð11 Ð5 Ð5 Ð8 Ð13 Ð19
16 16
Ð10 Ð9 Ð8 Ð8 Ð7 Ð9 Ð13 Ð17 Ð9 Ð8 Ð8 Ð8 Ð7 Ð8 Ð12 Ð16

Ð8 Ð9 Ð8 Ð8 Ð8 Ð9 Ð14 Ð17 Ð7 Ð9 Ð8 Ð8 Ð8 Ð9 Ð13 Ð15


24 Ð 36 24 Ð 36
Ð6 Ð8 Ð7 Ð9 Ð10 Ð11 Ð15 Ð18 Ð6 Ð7 Ð7 Ð9 Ð10 Ð11 Ð14 Ð16

SK11986 03/08/99
JM AEROFOIL
Fan Code: 100JM/25/4/3/...
BS 5750 Pt 1
EN 29001
ISO 9001
1000 mm 1760 rev/min 3 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000

0 20000 40000 60000 80000


800
ISO 5801 80

V 3.0
Type D

700
70

2.5
600 111
109 60
113

115
500 109 2.0
50
32°
106

400 109
40
109 1.5
104
24°

300 30
114
101
1.0

16°
200 20

102

0.5
100 8° 10

0 0 0.0
0 5 10 15 20 25

16
14
32°
12
10
8 24°
6
4 16°
2

0
0 5 10 15 20 25

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð9 Ð15 Ð16 Ð7 Ð4 Ð10 Ð14 Ð22 Ð7 Ð14 Ð15 Ð6 Ð4 Ð9 Ð12 Ð19


8 8
Ð3 Ð8 Ð14 Ð12 Ð10 Ð11 Ð13 Ð20 Ð2 Ð8 Ð14 Ð12 Ð10 Ð10 Ð12 Ð18

Ð2 Ð9 Ð14 Ð14 Ð12 Ð13 Ð16 Ð21 Ð1 Ð9 Ð14 Ð14 Ð12 Ð13 Ð14 Ð18
16 16
Ð2 Ð8 Ð13 Ð14 Ð13 Ð15 Ð18 Ð21 Ð1 Ð8 Ð13 Ð14 Ð13 Ð15 Ð17 Ð19

Ð6 Ð5 Ð9 Ð10 Ð13 Ð13 Ð15 Ð19 Ð5 Ð5 Ð9 Ð10 Ð13 Ð13 Ð14 Ð17
24 Ð 32 24 Ð 32
Ð4 Ð5 Ð11 Ð12 Ð14 Ð13 Ð15 Ð18 Ð3 Ð5 Ð11 Ð12 Ð14 Ð12 Ð13 Ð16

SK11991 03/08/99
JM AEROFOIL
Fan Code: 100JM/25/4/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1000 mm 1760 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D -- Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000 60000 70000

0 20000 40000 60000 80000 100000 120000


1600
ISO 5801 160

V 6
Type D

1400
140

5
1200 110
120

108 112
1000 4
100

109 115
800 109
80
3
32¡

107
600 105 110 60

2
24¡
105
400 106 40

16¡
1
105
200 20

0 0 0
0 5 10 15 20 25 30 35

45
40
35
30
32¡
25
20
15 24¡
10
16¡
5 8¡
0
0 5 10 15 20 25 30 35

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use

upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Octave Band Centre Frequency (Hz) Octave Band Centre Frequency (Hz)
Pitch Pitch
Angle 63 125 250 500 1k 2k 4k 8k Angle 63 125 250 500 1k 2k 4k 8k

-- 21 -- 22 -- 13 -- 10 -- 4 -- 6 -- 10 -- 17 -- 20 --22 -- 11 -- 9 -- 4 --5 -- 9 -- 15
8 8
-- 18 -- 19 -- 8 -- 10 -- 7 -- 5 -- 9 -- 14 -- 18 --19 -- 7 -- 10 -- 7 --4 -- 8 -- 12

-- 16 -- 16 -- 12 -- 11 -- 4 -- 5 -- 10 -- 16 -- 15 --16 -- 12 -- 11 -- 4 --5 -- 9 -- 14
16 16
-- 11 -- 11 -- 7 -- 9 -- 8 -- 8 -- 11 -- 15 -- 10 -- 11 -- 7 -- 9 -- 7 --7 -- 10 -- 13

-- 9 -- 9 -- 9 -- 8 -- 8 -- 8 -- 11 -- 15 -- 8 -- 9 -- 9 -- 8 -- 8 --8 -- 10 -- 14
24 -- 36 24 -- 36
-- 7 -- 7 -- 8 -- 8 -- 10 -- 10 -- 13 -- 16 -- 7 -- 7 -- 7 -- 8 -- 10 -- 10 -- 12 -- 15

SK12471 06/02/01
JM AEROFOIL
Fan Code: 100JM/25/4/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1000 mm 1760 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000 60000

0 20000 40000 60000 80000 100000


1200
ISO 5801 120

V
Type D

1000 4
100
112

108

112
800
80
3
108
110 114

107
32°
600
60

106
112
2

105 24°
400 40
107

16° 1
103
200 20

0 0 0
0 5 10 15 20 25 30

25

32°
20

15

24°
10

5 16°

0
0 5 10 15 20 25 30

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð13 Ð18 Ð15 Ð5 Ð5 Ð9 Ð14 Ð23 Ð11 Ð16 Ð14 Ð5 Ð4 Ð8 Ð13 Ð21
8 8
Ð9 Ð15 Ð16 Ð17 Ð9 Ð10 Ð13 Ð22 Ð6 Ð11 Ð13 Ð14 Ð6 Ð6 Ð10 Ð18

Ð9 Ð15 Ð15 Ð7 Ð4 Ð9 Ð13 Ð19 Ð8 Ð15 Ð15 Ð7 Ð4 Ð9 Ð12 Ð18


16 16
Ð4 Ð9 Ð11 Ð11 Ð8 Ð10 Ð13 Ð18 Ð4 Ð9 Ð11 Ð11 Ð7 Ð9 Ð12 Ð16

Ð8 Ð8 Ð10 Ð8 Ð8 Ð9 Ð12 Ð16 Ð7 Ð8 Ð10 Ð8 Ð8 Ð9 Ð12 Ð15


24 Ð 32 24 Ð 32
Ð5 Ð6 Ð10 Ð10 Ð11 Ð11 Ð13 Ð17 Ð5 Ð6 Ð9 Ð9 Ð11 Ð10 Ð12 Ð15

SK11992 03/08/99
JM AEROFOIL
Fan Code: 100JM/31/4/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1000 mm 1760 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000 60000 70000

0 20000 40000 60000 80000 100000 120000


1600
ISO 5801 160

V 6
Type D

1400
140

110 5
1200
120

107
111
1000 4
100

108
108
800 114
80
108 3

32°
104
600 110 60

105 2
24°
400 106 40

104 16° 1
200 20

0 0 0
0 5 10 15 20 25 30 35

45
40
35
30
32°
25
20
15 24°
10
16°
5 8°
0
0 5 10 15 20 25 30 35

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð21 Ð21 Ð15 Ð10 Ð4 Ð5 Ð11 Ð18 Ð20 Ð20 Ð13 Ð9 Ð4 Ð5 Ð10 Ð16
8 8
Ð17 Ð18 Ð11 Ð10 Ð7 Ð4 Ð8 Ð14 Ð17 Ð18 Ð9 Ð10 Ð7 Ð3 Ð8 Ð13

Ð15 Ð16 Ð12 Ð8 Ð4 Ð6 Ð11 Ð18 Ð14 Ð16 Ð12 Ð8 Ð4 Ð6 Ð10 Ð16
16 16
Ð10 Ð11 Ð8 Ð8 Ð7 Ð8 Ð12 Ð16 Ð9 Ð11 Ð8 Ð8 Ð6 Ð7 Ð11 Ð15

Ð8 Ð9 Ð9 Ð8 Ð8 Ð8 Ð12 Ð16 Ð7 Ð9 Ð9 Ð8 Ð8 Ð8 Ð11 Ð14


24 Ð 36 24 Ð 36
Ð7 Ð7 Ð8 Ð9 Ð10 Ð10 Ð13 Ð17 Ð6 Ð7 Ð7 Ð9 Ð10 Ð10 Ð12 Ð15

SK11993 07/10/99
JM AEROFOIL
Fan Code: 100JM/40/4/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1000 mm 1765 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000 60000 70000

0 20000 40000 60000 80000 100000 120000


1800
ISO 5801
7
V
Type D
1600

6
150
116
1400 113

110 5
116
1200

113
107
1000 108 116 4
100

109
40°
800
112
3
105

106
600 32°
107

50 2

400
102 24°

105 1
200
16°


0 0 0
0 5 10 15 20 25 30 35

60

50 40°
40

30
32°
20
24°
10
16°

0
0 5 10 15 20 25 30 35

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð11 Ð10 Ð8 Ð5 Ð7 Ð11 Ð18 Ð24 Ð9 Ð7 Ð6 Ð4 Ð8 Ð11 Ð17 Ð22


8 8
Ð12 Ð11 Ð6 Ð7 Ð7 Ð7 Ð12 Ð19 Ð8 Ð8 Ð4 Ð7 Ð8 Ð7 Ð11 Ð18

Ð10 Ð9 Ð9 Ð6 Ð7 Ð10 Ð14 Ð20 Ð6 Ð6 Ð8 Ð6 Ð8 Ð10 Ð13 Ð19


16 16
Ð9 Ð8 Ð6 Ð7 Ð10 Ð10 Ð11 Ð18 Ð4 Ð5 Ð4 Ð7 Ð11 Ð10 Ð10 Ð17

Ð6 Ð7 Ð9 Ð6 Ð14 Ð14 Ð16 Ð18 Ð3 Ð3 Ð7 Ð5 Ð13 Ð14 Ð16 Ð17


24 Ð 40 24 Ð 40
Ð7 Ð7 Ð7 Ð6 Ð14 Ð16 Ð17 Ð20 Ð4 Ð3 Ð5 Ð5 Ð13 Ð15 Ð17 Ð19

SK11995 11/06/99
JM AEROFOIL
Fan Code: 100JM/40/10/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1000 mm 690 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000

0 5000 10000 15000 20000 25000 30000 35000 40000


250 1.0
ISO 5801 25

V
Type D

200 0.8
20

90
88

150 0.6
15

89
87

89 87

89
100 10 0.4
85
32°
86
85

24°
82
50 5 0.2

84
16°

0 0 0.0
0 2 4 6 8 10 12

2.5

2.0

1.5 32°

1.0
24°
0.5
16°

0.0
0 2 4 6 8 10 12

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð8 Ð8 Ð5 Ð6 Ð12 Ð19 Ð26 Ð33 Ð6 Ð7 Ð5 Ð6 Ð12 Ð19 Ð26 Ð32


8 8
Ð3 Ð8 Ð9 Ð8 Ð11 Ð15 Ð22 Ð29 Ð1 Ð7 Ð10 Ð8 Ð11 Ð15 Ð22 Ð28

Ð5 Ð6 Ð7 Ð9 Ð12 Ð16 Ð22 Ð29 Ð2 Ð5 Ð7 Ð9 Ð12 Ð16 Ð22 Ð28


16 16
Ð4 Ð6 Ð8 Ð11 Ð13 Ð16 Ð23 Ð30 Ð1 Ð5 Ð9 Ð11 Ð12 Ð16 Ð23 Ð29

Ð4 Ð5 Ð9 Ð10 Ð11 Ð15 Ð19 Ð23 Ð2 Ð4 Ð10 Ð10 Ð11 Ð14 Ð19 Ð22
24 Ð 32 24 Ð 32
Ð5 Ð5 Ð8 Ð10 Ð11 Ð17 Ð21 Ð24 Ð3 Ð4 Ð8 Ð10 Ð11 Ð16 Ð21 Ð23

SK11997 11/06/99
JM AEROFOIL
Fan Code: 112JM/40/8/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1120 mm 865 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5000 10000 15000 20000 25000 30000 35000 40000

0 10000 20000 30000 40000 50000 60000


400 1.6
ISO 5801 40

V
Type D

350 1.4
35

99

300 97 1.2
30

98
97
250 1.0
25

98 96

99

200 0.8
20

93 32°

95
150 94 0.6
15

24°

92
100 10 0.4

92 16°

50 5 0.2

0 0 0.0
0 5 10 15 20

7
6
5 32°
4
3
24°
2
1 16°

0
0 5 10 15 20

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð11 Ð10 Ð5 Ð6 Ð11 Ð19 Ð24 Ð31 Ð8 Ð9 Ð4 Ð5 Ð11 Ð18 Ð24 Ð29
8 8
Ð8 Ð11 Ð9 Ð7 Ð9 Ð14 Ð19 Ð27 Ð4 Ð9 Ð8 Ð5 Ð8 Ð13 Ð18 Ð25

Ð7 Ð11 Ð7 Ð7 Ð11 Ð16 Ð21 Ð28 Ð4 Ð9 Ð7 Ð6 Ð9 Ð14 Ð20 Ð26


16 16
Ð4 Ð7 Ð8 Ð11 Ð12 Ð15 Ð19 Ð26 Ð2 Ð6 Ð8 Ð10 Ð11 Ð14 Ð19 Ð25

Ð5 Ð8 Ð8 Ð9 Ð11 Ð15 Ð18 Ð22 Ð2 Ð7 Ð8 Ð8 Ð11 Ð14 Ð17 Ð21


24 Ð 32 24 Ð 32
Ð5 Ð7 Ð7 Ð10 Ð11 Ð16 Ð19 Ð23 Ð2 Ð6 Ð8 Ð10 Ð11 Ð15 Ð19 Ð21

SK12001 11/06/99
JM AEROFOIL
Fan Code: 112JM/40/8/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1120 mm 865 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000

0 20000 40000 60000 80000


500 2.0
ISO 5801 50

V
Type D

400
100 40

1.5

96

99

300
97 30

97
96
1.0
100

92
200 32° 20

95 96

24° 0.5
92
100 10

93
16°

0 0 0.0
0 5 10 15 20 25

10

6 32°

4
24°
2
16°

0
0 5 10 15 20 25

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð15 Ð9 Ð5 Ð5 Ð11 Ð18 Ð25 Ð32 Ð12 Ð6 Ð4 Ð4 Ð11 Ð17 Ð23 Ð30
8 8
Ð16 Ð9 Ð9 Ð5 Ð7 Ð12 Ð19 Ð28 Ð12 Ð6 Ð8 Ð4 Ð7 Ð12 Ð17 Ð25

Ð14 Ð9 Ð5 Ð5 Ð9 Ð15 Ð22 Ð29 Ð10 Ð7 Ð4 Ð5 Ð10 Ð16 Ð21 Ð28


16 16
Ð12 Ð7 Ð8 Ð8 Ð8 Ð11 Ð17 Ð24 Ð7 Ð4 Ð6 Ð6 Ð9 Ð11 Ð15 Ð22

Ð7 Ð7 Ð6 Ð10 Ð12 Ð14 Ð17 Ð23 Ð4 Ð4 Ð4 Ð8 Ð11 Ð13 Ð16 Ð22


24 Ð 36 24 Ð 36
Ð7 Ð6 Ð6 Ð10 Ð12 Ð14 Ð17 Ð24 Ð3 Ð3 Ð4 Ð9 Ð11 Ð13 Ð16 Ð23

SK12002 11/06/99
JM AEROFOIL
Fan Code: 112JM/40/6/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1120 mm 1150 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000 60000

0 20000 40000 60000 80000 100000


700
ISO 5801 70

V
Type D
2.5
600
60

107

106

500 2.0
50

106
105

104 104
400
40
106 1.5

102 32°

300 30
103
101
1.0

24°
200 20
101

99 16° 0.5

100 10

0 0 0.0
0 5 10 15 20 25 30

16
14
12 32°
10
8
6 24°
4
16°
2

0
0 5 10 15 20 25 30

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð11 Ð11 Ð6 Ð4 Ð8 Ð16 Ð21 Ð28 Ð10 Ð8 Ð5 Ð4 Ð8 Ð15 Ð22 Ð27


8 8
Ð8 Ð8 Ð8 Ð6 Ð7 Ð11 Ð16 Ð23 Ð7 Ð5 Ð8 Ð6 Ð6 Ð11 Ð16 Ð22

Ð6 Ð9 Ð8 Ð7 Ð9 Ð13 Ð18 Ð25 Ð3 Ð7 Ð7 Ð7 Ð8 Ð13 Ð18 Ð24


16 16
Ð5 Ð6 Ð7 Ð10 Ð11 Ð14 Ð17 Ð24 Ð2 Ð5 Ð6 Ð10 Ð11 Ð14 Ð18 Ð23

Ð5 Ð8 Ð7 Ð9 Ð10 Ð14 Ð17 Ð21 Ð2 Ð6 Ð6 Ð9 Ð10 Ð13 Ð17 Ð20


24 Ð 32 24 Ð 32
Ð5 Ð7 Ð7 Ð10 Ð11 Ð14 Ð18 Ð22 Ð2 Ð6 Ð6 Ð10 Ð11 Ð14 Ð18 Ð21

SK12005 21/09/99
JM AEROFOIL
Fan Code: 112JM/40/6/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1120 mm 1150 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000 60000

0 20000 40000 60000 80000 100000


900
ISO 5801
3.5
V
Type D
800
80

3.0

700 107

103 2.5
600
60
106

104
500 2.0
104
103

106
400
40
1.5
98
32°

101 102
300

1.0
24°
200 99 20

100
0.5
16°
100

0 0 0.0
0 5 10 15 20 25 30

25

20

15
32°
10
24°
5
16°

0
0 5 10 15 20 25 30

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð16 Ð11 Ð5 Ð4 Ð7 Ð15 Ð21 Ð29 Ð13 Ð8 Ð5 Ð4 Ð8 Ð15 Ð20 Ð27


8 8
Ð15 Ð10 Ð9 Ð6 Ð5 Ð10 Ð15 Ð23 Ð11 Ð6 Ð8 Ð6 Ð5 Ð10 Ð14 Ð22

Ð15 Ð12 Ð7 Ð4 Ð7 Ð12 Ð19 Ð26 Ð11 Ð10 Ð6 Ð4 Ð8 Ð13 Ð18 Ð26
16 16
Ð12 Ð7 Ð8 Ð7 Ð8 Ð9 Ð14 Ð21 Ð7 Ð4 Ð6 Ð6 Ð8 Ð10 Ð12 Ð20

Ð7 Ð7 Ð7 Ð7 Ð10 Ð14 Ð15 Ð21 Ð4 Ð4 Ð6 Ð6 Ð10 Ð13 Ð14 Ð20


24 Ð 36 24 Ð 36
Ð7 Ð6 Ð7 Ð8 Ð11 Ð14 Ð15 Ð22 Ð4 Ð3 Ð5 Ð7 Ð10 Ð13 Ð14 Ð21

SK12006 11/06/99
JM AEROFOIL
Fan Code: 112JM/40/4/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1120 mm 1765 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000 60000 70000 80000

0 20000 40000 60000 80000 100000 120000


1600
ISO 5801 160

V 6
Type D

1400
140

5
1200
120

1000 4
100

800
80
32°
3

600 60

24°
2

400 40

16°
1
200 20

0 0 0
0 5 10 15 20 25 30 35 40

60

50
32°
40

30
24°
20

10 16°

0
0 5 10 15 20 25 30 35 40

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð12 Ð10 Ð10 Ð4 Ð6 Ð11 Ð19 Ð24 Ð11 Ð8 Ð9 Ð4 Ð5 Ð11 Ð19 Ð23
8 8
Ð9 Ð7 Ð11 Ð8 Ð6 Ð8 Ð13 Ð18 Ð8 Ð5 Ð10 Ð8 Ð6 Ð8 Ð14 Ð17

Ð7 Ð7 Ð11 Ð7 Ð7 Ð11 Ð15 Ð20 Ð5 Ð5 Ð11 Ð7 Ð7 Ð10 Ð16 Ð19


16 16
Ð5 Ð5 Ð9 Ð9 Ð12 Ð12 Ð16 Ð19 Ð4 Ð4 Ð9 Ð9 Ð11 Ð12 Ð16 Ð18

Ð6 Ð6 Ð10 Ð8 Ð9 Ð12 Ð15 Ð19 Ð4 Ð4 Ð9 Ð8 Ð10 Ð11 Ð15 Ð18


24 Ð 32 24 Ð 32
Ð6 Ð6 Ð8 Ð8 Ð11 Ð12 Ð17 Ð20 Ð4 Ð4 Ð8 Ð8 Ð11 Ð12 Ð16 Ð19

SK12009 11/06/99
JM AEROFOIL
Fan Code: 112JM/40/4/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1120 mm 1765 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000

0 20000 40000 60000 80000 100000 120000 140000


2500 10
ISO 5801 250

V
Type D

2000 8
200

1500 6
150

1000 100 4

32°

24°
500 50 2

16°


0 0 0
0 5 10 15 20 25 30 35 40 45

90
80
70
60
50 32°
40
30
24°
20
10 16°

0
0 5 10 15 20 25 30 35 40 45

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð17 Ð14 Ð9 Ð4 Ð5 Ð10 Ð17 Ð24 Ð15 Ð12 Ð7 Ð4 Ð5 Ð10 Ð16 Ð22
8 8
Ð16 Ð16 Ð8 Ð8 Ð5 Ð6 Ð12 Ð18 Ð13 Ð13 Ð6 Ð8 Ð5 Ð7 Ð11 Ð16

Ð16 Ð14 Ð9 Ð5 Ð5 Ð9 Ð15 Ð22 Ð12 Ð11 Ð8 Ð6 Ð6 Ð10 Ð14 Ð21


16 16
Ð13 Ð12 Ð6 Ð7 Ð7 Ð8 Ð10 Ð16 Ð9 Ð9 Ð4 Ð7 Ð8 Ð9 Ð9 Ð15

Ð8 Ð8 Ð7 Ð6 Ð10 Ð12 Ð14 Ð17 Ð5 Ð4 Ð6 Ð5 Ð10 Ð11 Ð14 Ð16


24 Ð 36 24 Ð 36
Ð8 Ð7 Ð6 Ð6 Ð11 Ð13 Ð15 Ð17 Ð5 Ð4 Ð4 Ð5 Ð10 Ð12 Ð14 Ð16

SK12010 11/06/99
JM AEROFOIL
Fan Code: 112JM/50/4/12/...
BS 5750 Pt 1
EN 29001
ISO 9001
1120 mm 1765 rev/min 12 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000

0 20000 40000 60000 80000 100000 120000 140000


2500 10
ISO 5801 250

V
Type D

2000 8
200

115

1500 112 6
150

114
112
114

112
1000 100 4
114
110

111
32°
113

500 50 2
109
24°

110

16°


0 0 0
0 5 10 15 20 25 30 35 40 45

100

80

60
32°
40

24°
20
16°

0
0 5 10 15 20 25 30 35 40 45

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð17 Ð18 Ð6 Ð8 Ð5 Ð9 Ð16 Ð21 Ð14 Ð16 Ð4 Ð8 Ð4 Ð6 Ð13 Ð18


8 8
Ð17 Ð17 Ð5 Ð8 Ð5 Ð9 Ð14 Ð19 Ð14 Ð15 Ð3 Ð8 Ð5 Ð7 Ð12 Ð17

Ð12 Ð15 Ð5 Ð7 Ð6 Ð9 Ð15 Ð21 Ð10 Ð13 Ð3 Ð7 Ð6 Ð7 Ð12 Ð18


16 16
Ð11 Ð14 Ð3 Ð9 Ð8 Ð10 Ð14 Ð19 Ð9 Ð12 Ð1 Ð9 Ð8 Ð9 Ð11 Ð16

Ð8 Ð9 Ð5 Ð9 Ð9 Ð11 Ð15 Ð18 Ð6 Ð7 Ð4 Ð8 Ð9 Ð9 Ð12 Ð16


24 Ð 36 24 Ð 36
Ð8 Ð10 Ð4 Ð9 Ð9 Ð11 Ð15 Ð18 Ð6 Ð7 Ð3 Ð9 Ð9 Ð9 Ð12 Ð16

SK12011 11/06/99
JM AEROFOIL
Fan Code: 125JM/40/10/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1250 mm 690 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000

0 20000 40000 60000 80000


300 1.2
ISO 5801 30

V
Type D

250 1.0
25

96

97

200 96
0.8
20
98

92
97
96

150 32° 0.6


15
90

93

94

100 24° 0.4


10

90

16°
92
50 5 0.2

0 0 0.0
0 5 10 15 20 25

4 32°

3
24°
2

1 16°

0
0 5 10 15 20 25

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð12 Ð6 Ð4 Ð7 Ð15 Ð21 Ð26 Ð31 Ð9 Ð5 Ð4 Ð7 Ð15 Ð21 Ð26 Ð30


8 8
Ð15 Ð10 Ð5 Ð4 Ð9 Ð15 Ð19 Ð29 Ð12 Ð10 Ð5 Ð4 Ð9 Ð15 Ð19 Ð28

Ð12 Ð9 Ð5 Ð4 Ð10 Ð16 Ð22 Ð27 Ð9 Ð8 Ð5 Ð4 Ð9 Ð15 Ð22 Ð26


16 16
Ð7 Ð5 Ð8 Ð8 Ð10 Ð13 Ð16 Ð24 Ð5 Ð4 Ð8 Ð8 Ð10 Ð13 Ð17 Ð23

Ð10 Ð7 Ð7 Ð5 Ð12 Ð16 Ð19 Ð21 Ð7 Ð5 Ð7 Ð5 Ð12 Ð15 Ð18 Ð20


24 Ð 32 24 Ð 32
Ð7 Ð4 Ð8 Ð8 Ð12 Ð15 Ð17 Ð20 Ð4 Ð3 Ð8 Ð8 Ð12 Ð14 Ð17 Ð19

SK12030 11/06/99
JM AEROFOIL
Fan Code: 125JM/40/10/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1250 mm 690 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000

0 20000 40000 60000 80000


400 1.6
ISO 5801 40

V
Type D

350 1.4
35

300 1.2
100 30

94
250 97 1.0
25

100

200 98
95 98 20 0.8

32°
91
150 15 0.6
96
97

24°
100 10 0.4
95

94
16°
50 5 0.2

0 0 0.0
0 5 10 15 20 25

9
8
7
6
5 32°
4
3 24°
2
1 16°

0
0 5 10 15 20 25

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð17 Ð7 Ð4 Ð4 Ð13 Ð21 Ð28 Ð34 Ð15 Ð6 Ð4 Ð4 Ð13 Ð21 Ð27 Ð33
8 8
Ð22 Ð10 Ð8 Ð3 Ð9 Ð15 Ð19 Ð30 Ð19 Ð7 Ð7 Ð2 Ð9 Ð15 Ð18 Ð28

Ð19 Ð8 Ð4 Ð4 Ð12 Ð19 Ð27 Ð32 Ð14 Ð6 Ð3 Ð5 Ð13 Ð20 Ð27 Ð32
16 16
Ð15 Ð7 Ð7 Ð5 Ð8 Ð12 Ð17 Ð25 Ð11 Ð3 Ð6 Ð4 Ð9 Ð13 Ð16 Ð24

Ð9 Ð6 Ð6 Ð7 Ð12 Ð14 Ð20 Ð25 Ð6 Ð3 Ð5 Ð5 Ð11 Ð13 Ð19 Ð24


24 Ð 36 24 Ð 36
Ð8 Ð5 Ð7 Ð7 Ð11 Ð13 Ð16 Ð23 Ð5 Ð1 Ð6 Ð6 Ð11 Ð12 Ð16 Ð22

SK12031 11/06/99
JM AEROFOIL
Fan Code: 125JM/40/8/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1250 mm 865 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000 60000

0 20000 40000 60000 80000 100000


450
ISO 5801

V
Type D
400
40

1.5
102

350 102

101

300 104
30

98
102
102

250 1.0
32°

95

200 99
20

99

24°
150
95
0.5

100 10
16°
97

50

0 0 0.0
0 5 10 15 20 25 30

10

8 32°

6
24°
4

2 16°

0
0 5 10 15 20 25 30

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð15 Ð7 Ð4 Ð6 Ð13 Ð20 Ð25 Ð30 Ð12 Ð6 Ð4 Ð6 Ð12 Ð20 Ð25 Ð28
8 8
Ð13 Ð12 Ð7 Ð4 Ð7 Ð14 Ð18 Ð26 Ð11 Ð11 Ð7 Ð4 Ð7 Ð14 Ð18 Ð25

Ð11 Ð11 Ð7 Ð4 Ð8 Ð14 Ð20 Ð26 Ð8 Ð9 Ð7 Ð4 Ð8 Ð13 Ð20 Ð24


16 16
Ð6 Ð6 Ð8 Ð9 Ð10 Ð13 Ð15 Ð23 Ð4 Ð5 Ð8 Ð9 Ð9 Ð13 Ð16 Ð22

Ð8 Ð8 Ð7 Ð5 Ð11 Ð15 Ð18 Ð21 Ð6 Ð7 Ð8 Ð5 Ð11 Ð14 Ð18 Ð20


24 Ð 32 24 Ð 32
Ð6 Ð6 Ð8 Ð9 Ð11 Ð15 Ð17 Ð20 Ð3 Ð5 Ð8 Ð9 Ð11 Ð14 Ð17 Ð19

SK12015 11/06/99
JM AEROFOIL
Fan Code: 125JM/40/8/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1250 mm 865 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000 60000 70000

0 20000 40000 60000 80000 100000 120000


600
ISO 5801 60

V
Type D

500 2.0
50

105

400 100
102 40
1.5

105

103
100 104
300
30

32°
96 1.0

101
102
200 20
24°

100

0.5

100 99 10
16°

0 0 0.0
0 5 10 15 20 25 30 35

18
16
14
12
10 32°
8
6 24°
4
2 16°

0
0 5 10 15 20 25 30 35

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð20 Ð11 Ð6 Ð3 Ð10 Ð18 Ð26 Ð32 Ð19 Ð8 Ð6 Ð3 Ð11 Ð18 Ð24 Ð31
8 8
Ð22 Ð12 Ð10 Ð3 Ð7 Ð13 Ð18 Ð27 Ð18 Ð9 Ð10 Ð2 Ð7 Ð13 Ð16 Ð25

Ð20 Ð9 Ð6 Ð4 Ð9 Ð17 Ð25 Ð31 Ð16 Ð7 Ð5 Ð4 Ð11 Ð18 Ð24 Ð30


16 16
Ð16 Ð7 Ð8 Ð5 Ð7 Ð11 Ð15 Ð23 Ð12 Ð5 Ð7 Ð4 Ð8 Ð11 Ð14 Ð22

Ð8 Ð7 Ð7 Ð7 Ð10 Ð13 Ð18 Ð24 Ð5 Ð5 Ð5 Ð6 Ð10 Ð13 Ð17 Ð23


24 Ð 36 24 Ð 36
Ð8 Ð6 Ð7 Ð7 Ð10 Ð13 Ð15 Ð22 Ð5 Ð4 Ð5 Ð6 Ð9 Ð12 Ð14 Ð21

SK12016 11/06/99
JM AEROFOIL
Fan Code: 125JM/40/6/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1250 mm 1150 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000 60000 70000 80000

0 20000 40000 60000 80000 100000 120000


800
ISO 5801 80

V 3.0
Type D

700
70

110

109 2.5
600
60

109

110

500 2.0
106 50
108
109

32°
400
103 40
1.5
108

106
300 30
24°

1.0
103

200 20

16°
104
0.5
100 10

0 0 0.0
0 5 10 15 20 25 30 35 40

25

20 32°

15

10 24°

5 16°

0
0 5 10 15 20 25 30 35 40

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð16 Ð10 Ð5 Ð4 Ð9 Ð17 Ð22 Ð27 Ð15 Ð7 Ð4 Ð4 Ð9 Ð17 Ð23 Ð26


8 8
Ð13 Ð14 Ð10 Ð4 Ð5 Ð11 Ð16 Ð21 Ð12 Ð11 Ð10 Ð4 Ð5 Ð10 Ð17 Ð20

Ð11 Ð11 Ð8 Ð5 Ð6 Ð11 Ð18 Ð24 Ð9 Ð9 Ð8 Ð5 Ð6 Ð11 Ð18 Ð23


16 16
Ð6 Ð7 Ð6 Ð9 Ð9 Ð12 Ð15 Ð20 Ð4 Ð5 Ð6 Ð9 Ð9 Ð12 Ð15 Ð19

Ð8 Ð9 Ð7 Ð6 Ð7 Ð14 Ð17 Ð20 Ð6 Ð7 Ð6 Ð6 Ð7 Ð13 Ð17 Ð19


24 Ð 32 24 Ð 32
Ð6 Ð7 Ð6 Ð9 Ð10 Ð14 Ð16 Ð19 Ð4 Ð5 Ð5 Ð9 Ð10 Ð13 Ð17 Ð18

SK12020 11/06/99
JM AEROFOIL
Fan Code: 125JM/40/6/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1250 mm 1150 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000

0 20000 40000 60000 80000 100000 120000 140000


1200
ISO 5801 120

V
Type D

1000 4
100

112
800
80
3
106
109

111
600
60
110
106 110

2
32°
102

400 108 40
108

24°

106
1

200 20
105
16°

0 0 0
0 5 10 15 20 25 30 35 40 45

40
35
30
25
32°
20
15
24°
10
5 16°

0
0 5 10 15 20 25 30 35 40 45

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð23 Ð14 Ð6 Ð3 Ð7 Ð15 Ð23 Ð29 Ð21 Ð11 Ð6 Ð3 Ð7 Ð15 Ð22 Ð28
8 8
Ð21 Ð14 Ð10 Ð5 Ð4 Ð11 Ð16 Ð22 Ð17 Ð11 Ð9 Ð5 Ð4 Ð11 Ð15 Ð20

Ð22 Ð15 Ð7 Ð4 Ð6 Ð14 Ð22 Ð28 Ð18 Ð12 Ð6 Ð4 Ð7 Ð14 Ð21 Ð28
16 16
Ð17 Ð8 Ð9 Ð6 Ð5 Ð9 Ð14 Ð19 Ð13 Ð5 Ð8 Ð5 Ð7 Ð10 Ð12 Ð18

Ð9 Ð7 Ð7 Ð7 Ð8 Ð13 Ð16 Ð22 Ð6 Ð4 Ð6 Ð6 Ð7 Ð12 Ð15 Ð21


24 Ð 36 24 Ð 36
Ð8 Ð6 Ð7 Ð8 Ð8 Ð12 Ð14 Ð19 Ð5 Ð4 Ð6 Ð7 Ð8 Ð12 Ð13 Ð18

SK12021 21/09/99
JM AEROFOIL
Fan Code: 125JM/50/6/12/...
BS 5750 Pt 1
EN 29001
ISO 9001
1250 mm 1150 rev/min 12 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000

0 20000 40000 60000 80000 100000 120000 140000


1200
ISO 5801 120

V
Type D

1000 4
100

109

800
106 80
3
108

108

113
600
105 60

108
2
104
32°
400 106 40
107

24°
102 1

200 20
104
16°

0 0 0
0 5 10 15 20 25 30 35 40 45

45
40
35
30
25 32°
20
15
24°
10
5 16°

0
0 5 10 15 20 25 30 35 40 45

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð19 Ð15 Ð6 Ð5 Ð5 Ð11 Ð18 Ð25 Ð15 Ð13 Ð5 Ð6 Ð5 Ð9 Ð15 Ð23


8 8
Ð17 Ð14 Ð4 Ð6 Ð6 Ð11 Ð16 Ð22 Ð13 Ð12 Ð3 Ð8 Ð6 Ð9 Ð14 Ð20

Ð14 Ð13 Ð6 Ð5 Ð5 Ð11 Ð18 Ð25 Ð12 Ð12 Ð4 Ð5 Ð5 Ð10 Ð16 Ð23
16 16
Ð11 Ð12 Ð3 Ð8 Ð8 Ð12 Ð16 Ð21 Ð8 Ð10 Ð1 Ð8 Ð8 Ð10 Ð13 Ð19

Ð8 Ð10 Ð6 Ð8 Ð8 Ð13 Ð15 Ð20 Ð5 Ð8 Ð4 Ð8 Ð9 Ð11 Ð13 Ð17


24 Ð 36 24 Ð 36
Ð8 Ð9 Ð5 Ð9 Ð9 Ð12 Ð15 Ð20 Ð5 Ð7 Ð3 Ð9 Ð9 Ð10 Ð12 Ð18

SK12024 11/06/99
JM AEROFOIL
Fan Code: 125JM/50/4/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1250 mm 1765 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000 100000 120000 140000

0 50000 100000 150000 200000


2500 10
ISO 5801 250

V
Type D

2000 8
200

123

118

1500 122 6
150
121

124
117
122

1000 114 32° 100 4

113 117

24°
113
500 50 2

112
16°

0 0 0
0 10 20 30 40 50 60 70

140
120
100
80 32°

60
40 24°

20 16°

0
0 10 20 30 40 50 60 70

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð21 Ð15 Ð11 Ð7 Ð3 Ð8 Ð15 Ð21 Ð18 Ð14 Ð9 Ð7 Ð3 Ð6 Ð14 Ð20


8 8
Ð15 Ð11 Ð6 Ð9 Ð6 Ð8 Ð12 Ð14 Ð13 Ð10 Ð4 Ð8 Ð5 Ð6 Ð11 Ð13

Ð18 Ð13 Ð7 Ð5 Ð5 Ð11 Ð17 Ð23 Ð15 Ð12 Ð5 Ð4 Ð5 Ð10 Ð16 Ð22
16 16
Ð14 Ð10 Ð4 Ð7 Ð9 Ð11 Ð14 Ð16 Ð11 Ð9 Ð2 Ð7 Ð8 Ð10 Ð13 Ð15

Ð9 Ð8 Ð7 Ð7 Ð9 Ð12 Ð16 Ð19 Ð6 Ð7 Ð5 Ð6 Ð8 Ð11 Ð15 Ð18


24 Ð 36 24 Ð 36
Ð11 Ð8 Ð5 Ð6 Ð10 Ð12 Ð15 Ð19 Ð7 Ð7 Ð3 Ð5 Ð9 Ð11 Ð14 Ð17

SK12026 11/06/99
JM AEROFOIL
Fan Code: 125JM/50/4/12/...
BS 5750 Pt 1
EN 29001
ISO 9001
1250 mm 1765 rev/min 12 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000 100000 120000 140000

0 50000 100000 150000 200000


3000 12
ISO 5801 300

V
Type D

2500 10
250

118

2000 8
200

116

118

118
1500 6
150
122
115

118

112
1000 32° 100 4
115 116

24°
111
500 50 2

113
16°


0 0 0
0 10 20 30 40 50 60 70

160
140
120
100
32°
80
60
24°
40
20 16°

0
0 10 20 30 40 50 60 70

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð19 Ð20 Ð8 Ð8 Ð4 Ð7 Ð14 Ð21 Ð16 Ð18 Ð6 Ð8 Ð3 Ð5 Ð12 Ð18


8 8
Ð17 Ð17 Ð6 Ð8 Ð5 Ð8 Ð14 Ð18 Ð14 Ð15 Ð4 Ð8 Ð5 Ð6 Ð11 Ð16

Ð15 Ð15 Ð9 Ð6 Ð5 Ð7 Ð15 Ð21 Ð12 Ð13 Ð7 Ð5 Ð5 Ð5 Ð11 Ð19


16 16
Ð12 Ð12 Ð4 Ð9 Ð8 Ð9 Ð13 Ð18 Ð9 Ð10 Ð1 Ð8 Ð8 Ð8 Ð10 Ð15

Ð9 Ð9 Ð7 Ð8 Ð8 Ð10 Ð14 Ð17 Ð6 Ð6 Ð6 Ð7 Ð8 Ð8 Ð11 Ð15


24 Ð 36 24 Ð 36
Ð9 Ð8 Ð6 Ð9 Ð9 Ð10 Ð14 Ð17 Ð6 Ð6 Ð4 Ð8 Ð9 Ð8 Ð11 Ð14

SK12027 11/06/99
JM AEROFOIL
Fan Code: 140JM/40/10/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1400 mm 690 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000 60000 70000

0 20000 40000 60000 80000 100000 120000


350 1.4
ISO 5801 35

V
Type C+2D

300 1.2
30

98

97
250 1.0
25
99

96
96
200 100 0.8
20
101
32°

93
150 96 0.6
15

96 24°

100 94 10 0.4

16°
96
50 5 0.2

0 0 0.0
0 5 10 15 20 25 30 35

10

32°
6

4 24°

2 16°

0
0 5 10 15 20 25 30 35

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð19 Ð13 Ð7 Ð3 Ð8 Ð11 Ð18 Ð28 Ð16 Ð11 Ð6 Ð3 Ð7 Ð9 Ð17 Ð27


8 8
Ð17 Ð11 Ð10 Ð6 Ð6 Ð6 Ð14 Ð26 Ð14 Ð9 Ð10 Ð5 Ð6 Ð5 Ð13 Ð25

Ð15 Ð10 Ð7 Ð3 Ð9 Ð15 Ð20 Ð23 Ð12 Ð9 Ð6 Ð3 Ð9 Ð14 Ð18 Ð22


16 16
Ð9 Ð6 Ð8 Ð9 Ð10 Ð7 Ð14 Ð22 Ð6 Ð4 Ð7 Ð9 Ð10 Ð7 Ð13 Ð21

Ð9 Ð5 Ð7 Ð7 Ð10 Ð14 Ð16 Ð17 Ð7 Ð4 Ð6 Ð6 Ð10 Ð13 Ð14 Ð15


24 Ð 36 24 Ð 36
Ð8 Ð5 Ð7 Ð8 Ð12 Ð14 Ð15 Ð17 Ð5 Ð4 Ð6 Ð6 Ð12 Ð13 Ð13 Ð15

SK12049 11/06/99
JM AEROFOIL
Fan Code: 140JM/40/10/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1400 mm 690 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000 60000 70000

0 20000 40000 60000 80000 100000 120000


500 2.0
ISO 5801 50

V
Type C+2D

400
40

1.5
95

94

300 96
30
93

98 93 1.0
97

200 92 32°
20

94
98

24°
95 0.5

100 10

96 16°

0 0 0.0
0 5 10 15 20 25 30 35

14
12
10
8 32°
6
4 24°

2 16°

0
0 5 10 15 20 25 30 35

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð17 Ð13 Ð8 Ð3 Ð7 Ð11 Ð20 Ð27 Ð14 Ð10 Ð7 Ð2 Ð6 Ð10 Ð20 Ð26
8 8
Ð18 Ð13 Ð11 Ð6 Ð7 Ð4 Ð14 Ð24 Ð15 Ð10 Ð10 Ð5 Ð5 Ð3 Ð14 Ð23

Ð9 Ð9 Ð8 Ð6 Ð8 Ð9 Ð14 Ð18 Ð5 Ð7 Ð7 Ð6 Ð7 Ð8 Ð12 Ð17


16 16
Ð13 Ð9 Ð10 Ð8 Ð8 Ð4 Ð13 Ð21 Ð9 Ð7 Ð8 Ð8 Ð7 Ð4 Ð13 Ð19

Ð7 Ð7 Ð8 Ð7 Ð9 Ð13 Ð15 Ð14 Ð4 Ð3 Ð6 Ð7 Ð9 Ð12 Ð13 Ð13


24 Ð 36 24 Ð 36
Ð8 Ð7 Ð7 Ð8 Ð10 Ð12 Ð16 Ð17 Ð3 Ð3 Ð4 Ð7 Ð8 Ð11 Ð14 Ð16

SK12050 11/06/99
JM AEROFOIL
Fan Code: 160JM/50/6/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1600 mm 1150 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 50000 100000 150000

0 50000 100000 150000 200000 250000 300000


1600
ISO 5801 160

V 6
Type C+2D

1400
140

5
113
1200
120

112
112
1000 4
100

117

110 114
800
80
115 3
32°
109
600 111 60

113 2
24°
400 109 40

16° 1
112
200 20

0 0 0
0 10 20 30 40 50 60 70 80 90

120

100

80 32°
60

40 24°

20 16°

0
0 10 20 30 40 50 60 70 80 90

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð19 Ð14 Ð9 Ð4 Ð5 Ð10 Ð13 Ð21 Ð16 Ð11 Ð8 Ð3 Ð5 Ð9 Ð13 Ð20


8 8
Ð19 Ð17 Ð14 Ð10 Ð5 Ð6 Ð6 Ð17 Ð16 Ð14 Ð13 Ð9 Ð4 Ð5 Ð5 Ð15

Ð17 Ð14 Ð8 Ð4 Ð6 Ð11 Ð16 Ð21 Ð14 Ð12 Ð7 Ð3 Ð5 Ð10 Ð15 Ð20
16 16
Ð11 Ð11 Ð9 Ð9 Ð8 Ð7 Ð6 Ð15 Ð8 Ð8 Ð7 Ð8 Ð8 Ð6 Ð5 Ð14

Ð11 Ð12 Ð8 Ð5 Ð7 Ð9 Ð14 Ð15 Ð8 Ð9 Ð7 Ð5 Ð6 Ð8 Ð13 Ð14


24 Ð 36 24 Ð 36
Ð8 Ð9 Ð7 Ð8 Ð9 Ð9 Ð11 Ð13 Ð5 Ð7 Ð5 Ð7 Ð8 Ð8 Ð10 Ð12

SK12057 11/06/99
JM AEROFOIL
Fan Code: 140JM/40/8/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1400 mm 865 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10000 20000 30000 40000 50000 60000 70000 80000

0 20000 40000 60000 80000 100000 120000


600
ISO 5801 60

V
Type C+2D

500 2.0
50

104

400 102
40
104 1.5

101
101
106
300
106 30
32°

98 1.0
101

200
101 24° 20

99

0.5
16°
100 101 10

0 0 0.0
0 5 10 15 20 25 30 35 40

18
16
14
32°
12
10
8 24°
6
4 16°
2

0
0 5 10 15 20 25 30 35 40

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð17 Ð14 Ð10 Ð3 Ð6 Ð11 Ð14 Ð26 Ð14 Ð12 Ð10 Ð2 Ð6 Ð9 Ð13 Ð25
8 8
Ð15 Ð12 Ð12 Ð7 Ð6 Ð6 Ð9 Ð24 Ð12 Ð10 Ð11 Ð6 Ð5 Ð5 Ð8 Ð23

Ð14 Ð11 Ð10 Ð3 Ð8 Ð13 Ð18 Ð23 Ð11 Ð9 Ð9 Ð3 Ð7 Ð13 Ð16 Ð22
16 16
Ð8 Ð7 Ð9 Ð9 Ð11 Ð9 Ð10 Ð21 Ð4 Ð5 Ð8 Ð9 Ð11 Ð8 Ð9 Ð20

Ð8 Ð6 Ð8 Ð7 Ð9 Ð13 Ð16 Ð17 Ð5 Ð5 Ð7 Ð6 Ð9 Ð12 Ð14 Ð16


24 Ð 36 24 Ð 36
Ð6 Ð6 Ð8 Ð8 Ð11 Ð14 Ð15 Ð17 Ð3 Ð5 Ð6 Ð6 Ð11 Ð13 Ð13 Ð16

SK12035 11/06/99
JM AEROFOIL
Fan Code: 140JM/40/8/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1400 mm 865 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000

0 20000 40000 60000 80000 100000 120000 140000


800
ISO 5801 80

V 3.0
Type C+2D

700
70

2.5
600
60
100

99
500 2.0
50
101

98

400
103 98 40
102 1.5

97 32°
300 30
99
102 1.0

24°
200 20
100

101 16° 0.5


100 10

0 0 0.0
0 5 10 15 20 25 30 35 40 45

25

20

15 32°

10
24°

5 16°

0
0 5 10 15 20 25 30 35 40 45

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð18 Ð15 Ð11 Ð4 Ð6 Ð11 Ð16 Ð26 Ð15 Ð12 Ð10 Ð2 Ð4 Ð9 Ð15 Ð25
8 8
Ð18 Ð14 Ð13 Ð8 Ð7 Ð5 Ð8 Ð22 Ð15 Ð11 Ð12 Ð6 Ð5 Ð3 Ð8 Ð21

Ð7 Ð10 Ð10 Ð6 Ð8 Ð9 Ð12 Ð18 Ð4 Ð7 Ð10 Ð6 Ð7 Ð9 Ð10 Ð17


16 16
Ð12 Ð10 Ð11 Ð9 Ð9 Ð5 Ð9 Ð20 Ð8 Ð7 Ð9 Ð9 Ð7 Ð5 Ð9 Ð18

Ð7 Ð7 Ð9 Ð7 Ð9 Ð12 Ð15 Ð15 Ð3 Ð4 Ð7 Ð7 Ð8 Ð11 Ð14 Ð14


24 Ð 36 24 Ð 36
Ð7 Ð7 Ð8 Ð7 Ð9 Ð11 Ð15 Ð17 Ð3 Ð4 Ð6 Ð6 Ð8 Ð11 Ð13 Ð16

SK12036 11/06/99
JM AEROFOIL
Fan Code: 140JM/50/8/12/...
BS 5750 Pt 1
EN 29001
ISO 9001
1400 mm 865 rev/min 12 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000

0 20000 40000 60000 80000 100000 120000 140000


800
ISO 5801 80

V 3.0
Type C+2D

700
70

102 2.5
600
60

100

500 102 2.0


50
101

104

400 99
40
1.5
102

98

300
32° 30
104
100
1.0

200 20
100 24°

102 0.5
100
16° 10

0 0 0.0
0 5 10 15 20 25 30 35 40 45

30

25

20
32°
15

10
24°
5 16°

0
0 5 10 15 20 25 30 35 40 45

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð17 Ð9 Ð10 Ð4 Ð6 Ð13 Ð19 Ð29 Ð14 Ð7 Ð10 Ð3 Ð5 Ð11 Ð17 Ð27
8 8
Ð19 Ð13 Ð12 Ð6 Ð6 Ð7 Ð11 Ð23 Ð16 Ð11 Ð12 Ð5 Ð4 Ð5 Ð9 Ð21

Ð16 Ð13 Ð7 Ð3 Ð8 Ð15 Ð23 Ð27 Ð13 Ð11 Ð6 Ð3 Ð7 Ð14 Ð20 Ð26
16 16
Ð11 Ð7 Ð12 Ð9 Ð8 Ð7 Ð11 Ð20 Ð7 Ð3 Ð11 Ð9 Ð8 Ð6 Ð7 Ð18

Ð5 Ð6 Ð10 Ð8 Ð9 Ð13 Ð16 Ð16 Ð2 Ð3 Ð8 Ð7 Ð8 Ð13 Ð15 Ð16


24 Ð 36 24 Ð 36
Ð7 Ð6 Ð10 Ð8 Ð9 Ð11 Ð15 Ð20 Ð3 Ð2 Ð8 Ð7 Ð8 Ð11 Ð14 Ð19

SK12038 11/06/99
JM AEROFOIL
Fan Code: 140JM/40/6/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1400 mm 1150 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000 100000 120000

0 50000 100000 150000 200000


1000 4.0
ISO 5801 100

V
Type C+2D

3.5

800
80
111
3.0

110

112

2.5
600 107 60
109
115
112
2.0
32°

106
108
400 40
1.5
107 24°

107
1.0

200 16° 20
108

0.5

0 0 0.0
0 10 20 30 40 50 60

45
40
35
30 32°
25
20 24°
15
10
16°
5

0
0 10 20 30 40 50 60

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð16 Ð16 Ð12 Ð5 Ð4 Ð9 Ð11 Ð22 Ð13 Ð14 Ð12 Ð4 Ð4 Ð8 Ð10 Ð21
8 8
Ð14 Ð14 Ð11 Ð9 Ð5 Ð7 Ð7 Ð19 Ð11 Ð12 Ð11 Ð8 Ð5 Ð6 Ð6 Ð18

Ð12 Ð12 Ð11 Ð5 Ð5 Ð11 Ð16 Ð21 Ð10 Ð11 Ð10 Ð5 Ð4 Ð11 Ð14 Ð20
16 16
Ð7 Ð8 Ð7 Ð9 Ð11 Ð10 Ð9 Ð18 Ð4 Ð6 Ð7 Ð9 Ð10 Ð10 Ð8 Ð17

Ð7 Ð8 Ð7 Ð7 Ð8 Ð12 Ð15 Ð17 Ð5 Ð6 Ð6 Ð6 Ð8 Ð11 Ð13 Ð15


24 Ð 36 24 Ð 36
Ð6 Ð7 Ð7 Ð8 Ð10 Ð13 Ð15 Ð17 Ð3 Ð6 Ð6 Ð7 Ð10 Ð12 Ð13 Ð16

SK12039 11/06/99
JM AEROFOIL
Fan Code: 140JM/40/6/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1400 mm 1150 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000 100000 120000

0 50000 100000 150000 200000


1400
ISO 5801 140

V
Type C+2D
5
1200
120

107
1000 4
100

106

107
800 105 80
3

110 105
108

600 60
104 32°

2
106
109

400 40
24°
106

200 107 16°


20

0 0 0
0 10 20 30 40 50 60

60

50

40
32°
30

20 24°

10 16°

0
0 10 20 30 40 50 60

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð19 Ð15 Ð12 Ð6 Ð4 Ð9 Ð12 Ð23 Ð16 Ð13 Ð12 Ð4 Ð3 Ð7 Ð12 Ð23
8 8
Ð18 Ð14 Ð14 Ð9 Ð6 Ð6 Ð5 Ð18 Ð15 Ð11 Ð13 Ð8 Ð5 Ð5 Ð5 Ð17

Ð7 Ð9 Ð12 Ð8 Ð7 Ð9 Ð10 Ð17 Ð3 Ð7 Ð11 Ð8 Ð6 Ð9 Ð8 Ð16


16 16
Ð11 Ð9 Ð12 Ð9 Ð9 Ð7 Ð6 Ð17 Ð8 Ð7 Ð11 Ð9 Ð8 Ð6 Ð6 Ð15

Ð6 Ð7 Ð10 Ð8 Ð8 Ð11 Ð15 Ð15 Ð2 Ð4 Ð8 Ð7 Ð8 Ð10 Ð13 Ð14


24 Ð 36 24 Ð 36
Ð7 Ð7 Ð9 Ð7 Ð9 Ð11 Ð13 Ð17 Ð2 Ð3 Ð7 Ð6 Ð8 Ð10 Ð11 Ð16

SK12040 11/06/99
JM AEROFOIL
Fan Code: 140JM/50/6/12/...
BS 5750 Pt 1
EN 29001
ISO 9001
1400 mm 1150 rev/min 12 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000 100000 120000

0 50000 100000 150000 200000


1400
ISO 5801 140

V
Type C+2D
5
1200
120

109

1000 4
100
106

108
107

800
111 80
3
106

108
600 60
105

32°
110 2
107

400 40

106 24°

200 108
20
16°

0 0 0
0 10 20 30 40 50 60

70
60
50
40 32°
30
20 24°

10 16°

0
0 10 20 30 40 50 60

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð17 Ð13 Ð8 Ð5 Ð5 Ð10 Ð16 Ð27 Ð15 Ð12 Ð6 Ð5 Ð4 Ð8 Ð14 Ð25


8 8
Ð19 Ð15 Ð12 Ð8 Ð5 Ð7 Ð8 Ð20 Ð16 Ð15 Ð10 Ð7 Ð3 Ð4 Ð6 Ð18

Ð15 Ð16 Ð10 Ð3 Ð5 Ð11 Ð19 Ð26 Ð12 Ð14 Ð8 Ð3 Ð4 Ð11 Ð17 Ð25
16 16
Ð10 Ð12 Ð6 Ð10 Ð8 Ð8 Ð8 Ð18 Ð6 Ð10 Ð4 Ð9 Ð8 Ð7 Ð5 Ð16

Ð5 Ð8 Ð7 Ð10 Ð9 Ð12 Ð16 Ð17 Ð2 Ð5 Ð5 Ð9 Ð8 Ð12 Ð15 Ð17


24 Ð 36 24 Ð 36
Ð6 Ð9 Ð6 Ð9 Ð9 Ð11 Ð13 Ð19 Ð3 Ð6 Ð4 Ð8 Ð8 Ð11 Ð12 Ð18

SK12042 11/06/99
JM AEROFOIL
Fan Code: 160JM/40/10/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1600 mm 690 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000

0 20000 40000 60000 80000 100000 120000 140000


450
ISO 5801

V
Type C+2D
400
40

1.5

350
103

101
300 100 30

100
250 103 98 1.0

32°

104
200
98 98 20

24°
150
101
96
0.5

100
16° 10

99

50

0 0 0.0
0 5 10 15 20 25 30 35 40 45

16
14
32°
12
10
8 24°
6
4 16°
2

0
0 5 10 15 20 25 30 35 40 45

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð18 Ð11 Ð4 Ð4 Ð9 Ð15 Ð18 Ð26 Ð15 Ð9 Ð4 Ð4 Ð8 Ð13 Ð17 Ð25


8 8
Ð17 Ð14 Ð11 Ð5 Ð5 Ð8 Ð12 Ð23 Ð13 Ð12 Ð10 Ð5 Ð5 Ð6 Ð11 Ð22

Ð16 Ð13 Ð9 Ð4 Ð7 Ð11 Ð14 Ð17 Ð13 Ð12 Ð8 Ð4 Ð6 Ð10 Ð12 Ð16
16 16
Ð11 Ð9 Ð9 Ð7 Ð8 Ð8 Ð10 Ð15 Ð8 Ð7 Ð9 Ð7 Ð7 Ð8 Ð9 Ð14

Ð12 Ð7 Ð6 Ð7 Ð10 Ð15 Ð17 Ð19 Ð10 Ð6 Ð5 Ð6 Ð9 Ð14 Ð16 Ð18


24 Ð 32 24 Ð 32
Ð9 Ð7 Ð8 Ð7 Ð8 Ð11 Ð12 Ð13 Ð7 Ð6 Ð7 Ð6 Ð8 Ð10 Ð10 Ð12

SK12064 11/06/99
JM AEROFOIL
Fan Code: 160JM/40/10/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1600 mm 690 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000 100000 120000

0 50000 100000 150000 200000


600
ISO 5801 60

V
Type C+2D

500 2.0
50

101

400
40
98
101
1.5

104

98 102
300
30

106 32°

97 1.0

98

200 20
102 24°

99

0.5

100 16° 10
100

0 0 0.0
0 10 20 30 40 50 60

25

20
32°
15

10 24°

5 16°

0
0 10 20 30 40 50 60

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð21 Ð13 Ð5 Ð3 Ð10 Ð16 Ð19 Ð28 Ð18 Ð10 Ð4 Ð2 Ð9 Ð14 Ð19 Ð28
8 8
Ð20 Ð14 Ð11 Ð5 Ð6 Ð7 Ð12 Ð24 Ð17 Ð10 Ð11 Ð3 Ð4 Ð6 Ð12 Ð23

Ð19 Ð14 Ð5 Ð3 Ð9 Ð14 Ð18 Ð22 Ð16 Ð12 Ð5 Ð3 Ð7 Ð13 Ð16 Ð21
16 16
Ð13 Ð7 Ð10 Ð9 Ð8 Ð7 Ð9 Ð18 Ð9 Ð4 Ð9 Ð9 Ð7 Ð6 Ð9 Ð16

Ð10 Ð10 Ð8 Ð7 Ð7 Ð10 Ð11 Ð13 Ð6 Ð7 Ð6 Ð6 Ð6 Ð9 Ð10 Ð12


24 Ð 36 24 Ð 36
Ð8 Ð8 Ð8 Ð8 Ð8 Ð10 Ð11 Ð13 Ð4 Ð4 Ð6 Ð7 Ð7 Ð10 Ð9 Ð12

SK12065 11/06/99
JM AEROFOIL
Fan Code: 160JM/50/10/12/...
BS 5750 Pt 1
EN 29001
ISO 9001
1600 mm 690 rev/min 12 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000 100000 120000

0 50000 100000 150000 200000


700
ISO 5801 70

V
Type C+2D
2.5
600
60

101
500 2.0
50

98
101

400
40

108 1.5

98
107 101

300 30
32°
98
1.0
100
104
200 20

24°
100

0.5

100 102
16° 10

0 0 0.0
0 10 20 30 40 50 60

30

25

20
32°
15

10 24°

5 16°

0
0 10 20 30 40 50 60

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð20 Ð13 Ð5 Ð3 Ð11 Ð15 Ð20 Ð29 Ð18 Ð10 Ð5 Ð2 Ð10 Ð12 Ð19 Ð27
8 8
Ð21 Ð15 Ð10 Ð4 Ð6 Ð7 Ð14 Ð26 Ð18 Ð13 Ð11 Ð4 Ð5 Ð5 Ð11 Ð24

Ð18 Ð14 Ð8 Ð4 Ð6 Ð11 Ð16 Ð22 Ð15 Ð12 Ð7 Ð4 Ð5 Ð10 Ð13 Ð21
16 16
Ð14 Ð10 Ð12 Ð8 Ð7 Ð5 Ð9 Ð18 Ð11 Ð7 Ð11 Ð8 Ð7 Ð4 Ð6 Ð16

Ð11 Ð8 Ð8 Ð7 Ð8 Ð11 Ð14 Ð16 Ð8 Ð5 Ð6 Ð6 Ð7 Ð11 Ð12 Ð15


24 Ð 36 24 Ð 36
Ð8 Ð8 Ð9 Ð8 Ð8 Ð9 Ð12 Ð15 Ð4 Ð3 Ð7 Ð7 Ð7 Ð9 Ð11 Ð14

SK12067 11/06/99
JM AEROFOIL
Fan Code: 160JM/40/8/6/...
BS 5750 Pt 1
EN 29001
ISO 9001
1600 mm 865 rev/min 6 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000 100000 120000

0 50000 100000 150000 200000


700
ISO 5801 70

V
Type C+2D
2.5
600
60

108

500 2.0
50
106
105

400 108 105


103 40
1.5
32°

109

300 103 103


30

24° 1.0
106
101
200 20

16°
104 0.5

100 10

0 0 0.0
0 10 20 30 40 50 60

30

25 32°

20

15 24°

10
16°
5

0
0 10 20 30 40 50 60

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð20 Ð14 Ð7 Ð4 Ð8 Ð14 Ð17 Ð24 Ð16 Ð12 Ð6 Ð3 Ð7 Ð12 Ð16 Ð23
8 8
Ð17 Ð14 Ð13 Ð7 Ð4 Ð7 Ð9 Ð21 Ð14 Ð12 Ð12 Ð6 Ð4 Ð6 Ð8 Ð19

Ð15 Ð14 Ð11 Ð4 Ð5 Ð9 Ð13 Ð16 Ð12 Ð13 Ð11 Ð4 Ð5 Ð9 Ð11 Ð15
16 16
Ð11 Ð9 Ð10 Ð8 Ð7 Ð8 Ð9 Ð14 Ð8 Ð8 Ð9 Ð7 Ð7 Ð8 Ð8 Ð13

Ð13 Ð8 Ð7 Ð6 Ð9 Ð14 Ð17 Ð19 Ð10 Ð7 Ð6 Ð4 Ð8 Ð12 Ð15 Ð17


24 Ð 32 24 Ð 32
Ð9 Ð8 Ð9 Ð8 Ð8 Ð10 Ð12 Ð13 Ð6 Ð6 Ð7 Ð6 Ð8 Ð9 Ð10 Ð11

SK12053 11/06/99
JM AEROFOIL
Fan Code: 160JM/40/8/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1600 mm 865 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 20000 40000 60000 80000 100000 120000 140000

0 50000 100000 150000 200000


1000 4.0
ISO 5801 100

V
Type C+2D

3.5

800
80

3.0

106

2.5
600 103
106 60

109
2.0
103 107

110 32°
400 40
102
1.5
103

107 24°

104 1.0

200 20

104 16°
0.5

0 0 0.0
0 10 20 30 40 50 60 70

50

40

32°
30

20
24°

10 16°

0
0 10 20 30 40 50 60 70

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð23 Ð17 Ð9 Ð3 Ð7 Ð15 Ð17 Ð27 Ð20 Ð14 Ð8 Ð1 Ð6 Ð13 Ð17 Ð26
8 8
Ð20 Ð14 Ð14 Ð6 Ð5 Ð7 Ð9 Ð21 Ð17 Ð11 Ð13 Ð5 Ð3 Ð6 Ð9 Ð20

Ð19 Ð16 Ð9 Ð3 Ð7 Ð13 Ð17 Ð22 Ð15 Ð14 Ð9 Ð3 Ð6 Ð12 Ð15 Ð20
16 16
Ð13 Ð7 Ð11 Ð10 Ð9 Ð7 Ð7 Ð16 Ð9 Ð4 Ð9 Ð10 Ð8 Ð7 Ð7 Ð14

Ð9 Ð10 Ð10 Ð7 Ð7 Ð9 Ð12 Ð12 Ð5 Ð7 Ð8 Ð7 Ð6 Ð8 Ð10 Ð11


24 Ð 36 24 Ð 36
Ð8 Ð8 Ð9 Ð8 Ð8 Ð9 Ð12 Ð13 Ð4 Ð4 Ð7 Ð7 Ð7 Ð9 Ð9 Ð12

SK12054 11/06/99
JM AEROFOIL
Fan Code: 80JM/25/8/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
800 mm 830 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2000 4000 6000 8000 10000 12000 14000 16000

0 5000 10000 15000 20000 25000


250 1.0
ISO 5801 25

V
Type D

200 0.8
20

83

82

150 84 0.6
15
83

82
85
86

100 82 0.4
32° 10

82
82

24°
82
50 5 0.2

83
16°

0 0 0.0
0 1 2 3 4 5 6 7 8

1.6
1.4
1.2
1.0
32°
0.8
0.6
24°
0.4
16°
0.2 8°
0.0
0 1 2 3 4 5 6 7 8

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð11 Ð8 Ð8 Ð4 Ð7 Ð14 Ð23 Ð33 Ð10 Ð7 Ð8 Ð6 Ð8 Ð14 Ð22 Ð31


8 8
Ð10 Ð9 Ð8 Ð6 Ð7 Ð8 Ð16 Ð25 Ð10 Ð8 Ð8 Ð8 Ð7 Ð7 Ð15 Ð24

Ð9 Ð10 Ð5 Ð6 Ð9 Ð15 Ð20 Ð28 Ð8 Ð10 Ð5 Ð6 Ð9 Ð15 Ð19 Ð26


16 16
Ð9 Ð7 Ð5 Ð8 Ð9 Ð13 Ð17 Ð25 Ð9 Ð7 Ð5 Ð9 Ð9 Ð12 Ð17 Ð23

Ð8 Ð8 Ð7 Ð6 Ð9 Ð12 Ð15 Ð21 Ð7 Ð8 Ð7 Ð7 Ð9 Ð12 Ð15 Ð20


24 Ð 36 24 Ð 36
Ð8 Ð7 Ð6 Ð7 Ð10 Ð13 Ð17 Ð23 Ð7 Ð6 Ð6 Ð8 Ð10 Ð13 Ð16 Ð21

SK11956 02/08/99
JM AEROFOIL
Fan Code: 160JM/50/6/9/...
BS 5750 Pt 1
EN 29001
ISO 9001
1600 mm 1150 rev/min 9 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 50000 100000 150000

0 50000 100000 150000 200000 250000 300000


1600
ISO 5801 160

V 6
Type C+2D

1400
140

5
113
1200
120

112
112
1000 4
100

117

110 114
800
80
115 3
32°
109
600 111 60

113 2
24°
400 109 40

16° 1
112
200 20

0 0 0
0 10 20 30 40 50 60 70 80 90

120

100

80 32°
60

40 24°

20 16°

0
0 10 20 30 40 50 60 70 80 90

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð19 Ð14 Ð9 Ð4 Ð5 Ð10 Ð13 Ð21 Ð16 Ð11 Ð8 Ð3 Ð5 Ð9 Ð13 Ð20


8 8
Ð19 Ð17 Ð14 Ð10 Ð5 Ð6 Ð6 Ð17 Ð16 Ð14 Ð13 Ð9 Ð4 Ð5 Ð5 Ð15

Ð17 Ð14 Ð8 Ð4 Ð6 Ð11 Ð16 Ð21 Ð14 Ð12 Ð7 Ð3 Ð5 Ð10 Ð15 Ð20
16 16
Ð11 Ð11 Ð9 Ð9 Ð8 Ð7 Ð6 Ð15 Ð8 Ð8 Ð7 Ð8 Ð8 Ð6 Ð5 Ð14

Ð11 Ð12 Ð8 Ð5 Ð7 Ð9 Ð14 Ð15 Ð8 Ð9 Ð7 Ð5 Ð6 Ð8 Ð13 Ð14


24 Ð 36 24 Ð 36
Ð8 Ð9 Ð7 Ð8 Ð9 Ð9 Ð11 Ð13 Ð5 Ð7 Ð5 Ð7 Ð8 Ð8 Ð10 Ð12

SK12057 11/06/99
JM AEROFOIL
Fan Code: 160JM/50/6/12/...
BS 5750 Pt 1
EN 29001
ISO 9001
1600 mm 1150 rev/min 12 Blades 60 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C Ð Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 50000 100000 150000

0 50000 100000 150000 200000 250000 300000


1800
ISO 5801
7
V
Type C+2D
1600

6
150
113
1400

5
111
1200
113

119
1000 4
100
110
118 113

800
32°
110 3

111
600 115

50 2
24°
111
400

113
16° 1
200

0 0 0
0 10 20 30 40 50 60 70 80 90

140
120
100
32°
80
60
24°
40
20 16°

0
0 10 20 30 40 50 60 70 80 90

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k
Angle 63 125 250 500 1k 2k 4k 8k

Ð23 Ð16 Ð10 Ð3 Ð5 Ð12 Ð15 Ð24 Ð20 Ð15 Ð8 Ð3 Ð4 Ð10 Ð13 Ð22
8 8
Ð22 Ð19 Ð14 Ð8 Ð4 Ð7 Ð8 Ð18 Ð19 Ð18 Ð11 Ð7 Ð3 Ð4 Ð5 Ð16

Ð16 Ð18 Ð13 Ð6 Ð4 Ð7 Ð12 Ð18 Ð13 Ð16 Ð11 Ð6 Ð3 Ð7 Ð9 Ð17


16 16
Ð12 Ð15 Ð9 Ð11 Ð8 Ð7 Ð5 Ð13 Ð9 Ð13 Ð7 Ð11 Ð7 Ð6 Ð2 Ð10

Ð9 Ð12 Ð9 Ð7 Ð7 Ð9 Ð12 Ð14 Ð6 Ð9 Ð7 Ð6 Ð6 Ð8 Ð11 Ð13


24 Ð 36 24 Ð 36
Ð7 Ð10 Ð8 Ð9 Ð9 Ð9 Ð11 Ð14 Ð3 Ð6 Ð5 Ð8 Ð8 Ð9 Ð9 Ð13

SK12058 11/06/99