Professional Documents
Culture Documents
SYMBOLS DESCRIPTION
15KVA 25KVA
ELECTRICAL PANEL
15KVA 10KVA
FT DG SET
DG GENSET
FUELLING LIGHTING
Fall
Fall
Fall
STABILIZER STABILIZER Automation
Cabinet
C2 AIR COMPRESSOR
1350
F.TOI
1500
RETTUHS GNILLOR
OFFICE SPACE 1500
ELECTRICAL PANEL
10.08 Sqm
ISOLATION TRANSFORMER
AIR COMPRESSOR DG SET 2000 D2
2800
20 KVA ELECTRICAL METER BOARD
15KVA 10KVA
FT
3600 1500
FUELLING LIGHTING
ELECTRICALS
EV
STABILIZER STABILIZER Automation
D2
CHARGING
EV CHARGING POINT
Cabinet M.TOI
C7
1350
CHARGING
EV
CHARGING
EV
1350
F.TOI EP1
RETTUHS GNILLOR
OFFICE SPACE 1500 EARTH PIT FOR TT DECANTATION, TANKS & OTHERS
ELECTRICAL PANEL
GI
10.08 Sqm
D2 C3
LLAW NEERG
2000 BATTERIES
2800
EP1 & INVERTERS
UR
OUTDOOR CCTV CAMERA
1500
FT
3600 GI
M.TOI D2
SD INDOOR CCTV CAMERA
1350
CORRIDOR
BATTERIES 1.0M WIDE
& INVERTERS
UR
FT
NETWORK VIDEO RECORDER
SD
CORRIDOR ADV. BOARD STATUTORY BOARD DECANTATION LIGHT (FLAME PROOF)
1.0M WIDE C6
LIGHTED MONOLITH
GROUND LEVEL PLAN (7.5M x 3.0)
1 V-SAT ANTENNA
6000
10000
SAFETY
YARD LIGHT
SERVICES DISPLAY
SERVO LUBE DISPLAY
3000
TANK-1 HSD (20 KLD)
D1
6000
D1 NFR-KIOSK
OFFICE SPACE
CHANGE FRP DOUBLE WALL 20KL FUEL TANK
6450 7050 ROOM 2.5Mx2.8M
1.8Mx2.8M
2800
2800
D3 D3 UG WATER TANK (10 KL)
TANKS/FILL/VENTS
SAMPLE LUBE STORE
ROOM SEPTIC TANK WITH SOAK PIT
MS/HSD MS/HSD ROOM
1400
1400
1800 2500
3000
OVER HEAD WATER TANK
LOCKERS 1350 1350
6000
SHELF SHELF
VENT PIPE
1500 EP2 NOTE-4
FILL POINT
GI BUILDING LINE
FIRST LEVEL PLAN (7.5M x 3.0) OIL WATER SEPARATOR
2
CATTLE CATCHER
9000
OTHERS
BOLLARD
EGRESS 2W/4W AIR GAUGE
6000
BUFFER STRIP WITH KERB WALL (3M DEPTH AND
VARYING LENGHTS AS PER SITE )
V SAT WATER TANK
INGRESS SERVO LUBE CHANGE & POLLUTION CHECK (6 SQ.M.)
BUILDINGS
4000
C4 UTILITY STORE ROOM
3000
C1
MALE TOILET PH./FEMALE
TOILET
RIGHT OF
7500 5000 7500 WAY
ISLAND DETAILS :
6300
ROAD 5400
2160
800
RURAL CORE AGRICULTURE (20X20)
NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED **ANY ABOVE GROUND STRUCTURE SHOULD BE MINIMUM 6 METERS AWAY
PLOT DETAILS: FRP TANK DETAILS PROPOSED: FUEL BAY DETAILS: REFERENCES:
5. UNDER GROUND (UG) DECANTATION IS PROPOSED.
1. TOTAL PLOT AREA: 400SQM TANK - 1 MS = 20 KL FUEL BAY-1 = CARS,TRACTORS & LMV. 1. MS - MOTOR SPiRIT 7. CNG -COMPRESSED NATURAL GAS
OTHERWISE. 6. SET BACKS REQUIREMENTS ARE APPLICABLE FOR FROM NEAREST DISPENSER .
2. DEVELOPED ARAE : 400 SQM TANK - 2 HSD = 20 KL FUEL BAY -2 = TWO WHEELERS & THREE WHEELERS 2. XP - EXTRA PREMIUM 8. EV -ELECTRICAL VEHICLE
2. DIMENSIONS ARE NOT TO BE SCALED. CONVENTIONAL RCC BUILDINGS ONLY. 9. ELECTRICAL EQUIPMENT / LIGHTS USED IN HAZARDOUS LOCATION SHALL 3. UNDEVELOPED AREA : 0.00 SQM 3. XM - EXTRA MILE CHARGING UINT
3. ANY DISCREPANCY BETWEEN THIS DRAWING AND OTHER BE RATED FOR APPROPRIATE ZONE.
7. NUMBER OF TANK 's & FUEL PRODUCTS ARE SHOWN TENTATIVE , 4. AREA OF CANOPY : 10M x 6M 4. HSD - HIGH SPEED DIESEL 9. MH-MAN HOLE
DRAWINGS MUST BE BROUGHT TO THE NOTICE OF DESIGN
ACTUAL WOULD BE AS PER IOCL TRADING ANALYSIS. 5. EVP - EXTENDED VENT POINT 10. OWS-OIL WATER SEPARATOR
TEAM.
4. THIS LAYOUT IS ONLY A GENERALIZED TEMPLATE OF AN 8.OWS TO BE PROVIDED WHERE EVER VEHICLE SERVICE UNIT IS 6. EFP - EXTENDED FILL POINT
ARCHETYPE, ACTUAL SETBACKS WILL DEPEND ON SITE CONSIDERED IN THE LAYOUT
SPECIFIC AND ZONE BUILDING BYE-LAWS/MUNICIPAL RULES.