Y LINE
LEGENDS:
±3000mm
GV GV
WC
1Ø CWL
±1500mm
2ND FLR LN 4Ø SS SHO
2'Ø 100 MMØ SOIL 150MMØ SOIL
2'Ø
FD
WASHING FAUCET PIPE INLET PIPE OUTLET
4Ø RISER
FIREWALL AREA (VERIFY ACTUAL)
UP CO 2'Ø
LAV 4'Ø PVC
FD CB
2'Ø
2'Ø SS GUTTER
UP LAV AD
1/2'Ø
FIREWALL AREA
2'Ø WC
4'Ø PVC
CO
PLAN
FIREWALL AREA
EXISTING ACCORDING TO THE PROVISION OF THE NATIONAL PLUMBING CODE
FIREWALL AREA
(TYPICAL) OF THE PHILIPPINES, NATIONAL BUILDING CODE OF THE PHILIPPINES, BE HIGH DENSITY POLYETHYLENE (HDPE),
STRUCTURE
AND ITS IMPLEMENTING RULES AND REGULATIONS. POLYPROPYLENE PIPESJOINTING SHALL BE BY
AREA
SOCKET FUSION OR COMPOSITE PIPES WITH BRASS
CB 2. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND FITTINGS - PIPE COMPOSITION SHALL BE HDPE OR
XPE WITH LASER WELDED ALUMINUM, CONFORMING
100
HB SPEIFICATIONS. THE ARCHITECT/ENGINEER SHALL BE NOTIFIED IMMEDIATELY
OF ANY DISCREPANCY FOUND THEREIN. HIS/HER DECISION SHALL BE FINAL. TO ASTM F1135 "UNITEC, "AMICO", VESBO" BRAND
CO CO OR APPROVED EQUAL.
100MMØ SOIL
CB PIPE INLET AIR AIR 3. ALL PIPES SHALL BE INSTALLED IN ANY RELOCATION REQUIRED FOR PROPER
HB CHAMBER CHAMBER HOT WATER LINES SHALL BE HIGH DENSITY POLYETHYLENE (HDPE).
WATER LEVEL WATER LEVEL 150MMØ SOIL EXECUTION OF OTHER TRADES AND SHALL BE WITH THE PRIOR APPROVAL OF THE
ARCHITECT AND/OR ENGINEER. PROPYLENE PIPES. JOINTING SHALL BE BY SOCKET
CARBON FILTER PIPE OUTLET FUSION OR COMPOSITE PIPES WITH BRASS FITTINGS -
EXISTING
STRUCTURE 4. PROPOSED PLUMBING & SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL PIPE COMPOSITION SHALL BE (HDPE) OR (HPE) WITH
AREA LOCATION, DEPTH AND INVERT ELEVATION OF THE EXISTING PIPES AND LASER WELDED ALUMINUM, CONFORMING TO ASTM
OPEN ABOVE
F1335, "UNITEC", "AMICO", "VESBO" BRANDS OR
±1800
STRUCTURES AS VERIFIED BY THE CONTRACTOR.
APPROVED EQUAL.
DIGESTIVE 5. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1 % AS MINIMUM,
LEACHING CHAMBER SEWER/WASTE PIPES SHALL BE POLYVINYL CHLORIDE (PVC) PIPES FIITINGS
PERFORATED FLOOR UNLESS OTHERWISED NOTED.
OPEN ABOVE
UP-FLOW CHAMBER VENT LINES/STACKS SERIES 100 II, "MOLDEX", "EMERALD" BRAND OR
6. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH DOWNSPOUTS APPROVED EQUAL. JOINTING SHALL BE BY SOLVENT
PROPERTY LINE
2ND FLR LN STORM DRAINAGE CEMENT JOINTING CONFORMING TO ASTM ASTM D2564.
THE MANUFACTURERS INSTRUCTIONS.
PROPERTY LINE
7. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE. COORDINATE WATER METER "ARAD", "ASAHI" BRAND OR MWSI APPROVED.
CB 2ND FLR LN WORKS WITH SEWER LINE EFFLUENT DISPOSAL POINT & WATER LINE SERVICE
VALVES "NIBCO", "KITZ", "HONEYWELL" BRAND OR APPROVED
150
CONNECTING POINT UNLESS OTEHRWISE SPECIFIED.
EQUAL.
CV DN
8. ALL PIPES SIZES ARE IN MILLIMETERS AND ALL DIMENSIONS ARE IN METERS
CB UNLESS OTHERWISE SPECIFIED. DRAINS "UNILEX" BRAND OR APPROVED EQUAL
PROPERTY LINE
4" Ø STORM PIPE CV 9. ALL PIPE DIAMETER ARE INSIDE DIMENSION (NOMINAL) UNLESS OTHERWISE
TAPPED TO EXISTING GV SPECIFIED.
STREET DRAINAGE LINE
100 MM THK.
PROPERTY LINE
4" Ø STORM PIPE GRAVEL BEDDING SECTION THRU "A" 10. VERIFY ARCHITECTURAL PLANS FOR THE EXACT LOCATION OR SETTING OUT OF
FLOOR DRAINS, FLOOR CLEAN-OUTS AND OTHER PLUMBING APPURTENANCES.
GV GV TAPPED TO EXISTING
RAMP STREET DRAINAGE LINE
11. ALL CONCEALED VALVES OR VALVES AT ABOVE CEILING SHALL BE PROVIDED
UP
4" Ø STORM PIPE WITH ACCESS MANHOLE/HANDHOLE.
TAPPED TO EXISTING
STREET DRAINAGE LINE RAMP GV
PROPERTY LINE
SEPTIC TANK DETAIL 12. THE WORK THROUGHOUT SHALL BE EXECUTED IN THE BEST AND MOST
PROPERTY LINE
UP RAMP THOROUGH MANNER KNOWN TO THE TRADE AND TO THE SATISFACTION OF
150mmØ WASTE PIPE UP
TAPPED 4" Ø STORM PIPE THE ARCHITECT AND/OR ENGINEER.
TAPPED TO EXISTING 150mmØ WASTE PIPE
TO EXISTING STREET 1" Ø COLD WATERLINE STREET DRAINAGE LINE
SEWER LINE TAPPED FROM EXISTING TAPPED
RIGHT OF WAY TO EXISTING STREET
PROPERT SEWER LINE PROPERTY LINE
Y LINE
1" Ø COLD WATERLINE
TAPPED FROM EXISTING
PROPERTY LINE
GRD FLR PLUMBING LAYOUT )
SS
GU
AL TT
ER
TU
Y AC
4Ø SS
OPEN BELOW VSTR
L INE
TY
ER
OP
PR A
RE
OPEN BELOW LA
CONCRETE LEDGE 1Ø CWL AL
FD EW
OV
E FIR
1/2'Ø N AB
CONDENSER AREA 2'Ø O PE
CO 4Ø RISER
2'Ø
SHO LAV 1Ø CWL CONCRETE LEDGE
WC FD 4Ø
FD SS
4Ø RISER 2'Ø 2'Ø 1/2'Ø CONDENSER AREA
CO FINISHED WALL
LAV SHO CONCRETE WALL CONCRETE WALL VSTR SS
GU
TT
WC FD CLEANOUT COVER FLOOR CLEANOUT LAVATORY 38 mmØVENT ER
FIREWALL AREA
850 mm
AC
IFY
FIREWALL AREA (VERIFY ACTUAL)
FLOOR LEVEL R
CWS METALLIC DN
VE
VARIES
SANITARY WYE A(
PIPE SLEEVE
VARIES
DN CONCRETE RE
P-TRAP LA
AL
FLOORING CLEANOUT UA
L) EW
T FIR
50 mmØ Y AC
WATER SUPPLY DRAIN LINE RIF
PLAN CMU WALL RE
A(
VE
EXISTING LA
CO
CO NC
AL ND RE
EN TE
STRUCTURE FINISH FLOOR LINE EW SE
RA
LE
DG
E
AREA FIR RE
A
FD
OPEN ABOVE
1/4" BEND
SECTION
CONCRETE WALL
LAVATORY
OPEN ABOVE
FD
A
RE
FLOOR CLEANOUT DOWNSPOUT SOLID BRASS AL
LA
DN EW
STRAINER FIR
DETAIL DETAIL OP
EN
A BO
VE
UP
COLD WATER SUPPLY (SEE
15mmØ HOSE BIBB
PLANS FOR CONTINUATION
AND PIPE SIZE) FLOOR FINISH A
UP FIN. FLOOR LINE RE
25mmØ ELBOW LA
AL FD
FD PIPE STRAP EW CO
FIR CO
ND
NC
RE
TE
EN LE
SE DG
RA E
RE
A
600
FD A BO
V E
EN
OP
OPEN BELOW FINISH FLOOR LINE
50 VENT 3RD FLR LVL
L)
25mmØ ELBOW
UA
CT
25mmØ CWL
IF YA
DN ER
PROPERTY LINE
V
OPEN BELOW FIN. GRADE/ FIN. FLR.
SEE PLANS A(
100 RE
FOR CONT. SEWER PIPE LA
AL
EW
PROPERTY LINE SECTION CAST IRON BODY FIR
PROPERT FD CO
Y LINE
PROPERTY LINE
HOSE BIBB DETAIL INSTALLATION DETAIL
NC
CO
RE
ND
EN
TE
GE
LE
D
WATER CLOSET
SE
R
WC 'Ø
2
O
FD W
2'Ø
C
'Ø
2'Ø
REA 1 LA
V
FD /2'Ø
LA SH 2'Ø
AL O 1Ø
EW CW
FIR L
4'Ø
PV 4Ø
C RIS
ER
FD
4Ø SS EA
L AR
OPEN BELOW UP
AL
E EW
AB
OV FIR
EN
OP
4Ø
OPEN BELOW SS
CONCRETE LEDGE 400
FD
4Ø
CONDENSER AREA RIS
1Ø
ER
CW
L
CONCRETE LEDGE
FD RE
A
A
CONDENSER AREA A LL 4'Ø
LA
2'Ø
PV
EW C V 2'Ø
FIREWALL AREA (VERIFY ACTUAL)
FIR WC
FD 1/2
'Ø
SH CO
NC
O CO C RE
SH 2'Ø TE
DOWNSPOUT ON LE
OV
E O 1/2 D EN
DG
E
AB 'Ø
FIREWALL AREA (VERIFY ACTUAL)
2'Ø SE
EN FD RA
OP WC RE FD
2'Ø A
PVC LA
V 1/2
2ND
L)
FLR LVL
UA
'Ø
INLET PIPE CO
CT
YA
DN E RIF
(V
FIREWALL AREA
A
400
RE
FIREWALL AREA
LA
AL
PR EW
OP UP FIR
GV
ER
PVC TY
OUTLET PIPE CO GV
LIN
E
A L)
U
CONCRETE MANHOLE 4mm THK. X 25mm
A CT FD
IFY
COVER W/ 12mmØ FLAT BAR GRATING 2N
DF
W/ 6mmØ BAR DOWEL R LR
(VE
LIFTING HANDLE 4'Ø PR
PLAN WELDED @ 4-CORNER
EA
4'Ø
PV
LN
PV
C OP
L AR LA
V 2'Ø C FA ER
AL UC TY
FD ET FD
EW WC 2'Ø
CB LIN
EXISTING FIR PV
C 1/2
'Ø
2'Ø
WA E
4'Ø 2'Ø 2'Ø S CO
STRUCTURE CO UP CO HING SK
1/2 2'Ø
'Ø
AREA 1Ø
OPEN ABOVE
ET EDØ S CB
A
DR TOTO
RE
100
AIN E RM
AGXIS PIP LA
E LTIN E
INEG
CB AL
6-12MM Ø EW
COVER PR FIR
OP HB
REINFORCED ER
DN TY
LIN
GV E
VARIES
15 2N
TO 0m DF 4Ø
mØ R
EX WA UPAMP LR
LN SS
IS
DN SETING TA STE
WE S PP P CO
R TR ED IPE ST TA
RE P 4" 2'Ø
LIN EE ST EXIS
E T ETPEDØ S CV R 1/2 SK
DR T TO ARUCTTING 4Ø 'Ø
AINO E RM EA UR RIS 2N 1Ø CB
TA 1" AGXIS PIP GV E ER D
FL CW
PP Ø E LTIN E
PROPERTY LINE
GV
R
ED CO INEG GV LN L
FRLD
OMWA
EXTER
IST LIN
WA
100
IN E 4'Ø
G SH
PVC PV
COING2 C
OUTLET PIPE 'Ø F
D
UP 2'Ø
FA
FD PVC UC
ET
INLET PIPE 4'Ø GRD FLR LVL
75mmØ PVC PV CO
DOWNSPOUT 2'Ø
LA 2'Ø C
100 THK. CHB HB 1/2 FD V
RI R
UPAMP
SECTION GH 2'Ø 'Ø
RAINWATER TANK
FD 7-12MM REINFORCED T
CB
CO WC
OF L)
OPEN BELOW SPACED AS SHOWN
WA UA
PV
C CT
PROPERTY LINE
YA
2N
Y D
FL CO 4'Ø
CV R
LN
E RIF
A (V
GV RE
LA
OPEN BELOW
CATCH BASIN DETAIL 1
TA" Ø
PP CO
ED LD
GV
4"
FIR
EW
AL
PROPERTY LINE FR WA
OM TE STTAPØ S
REPE TO
EXRLIN ET D T RM
IST E DRO E PIP
RE E LIN REPESTO
ET E ET D T RM
DRO E P
IP
AINXIS
AG TEIN
ELG
IN
E
REPUBLIC ACT 9266 PROJECT TITLE OWNER: APPROVED BY: REVISION DATE SHEET CONTENTS SHEET NO.
ART IV, SECTION 33
DRAWINGS AND SPECIFICATIONS DULY
1
AR. JOHN KARL M. BENTING
A R C H I T E C T MASTER PLUMBER
SIGNED AND SEALED AS INSTRUMENT OF
SERVICE ARE INTELLECTUAL PROPERTY. Proposed Three-Storey AS SHOWN
PRC REG. NO: 37339 PTR NO: 1651096 PRC REG. NO: PTR NO:
IT SHALL BE UNLAWFUL FOR ANY PERSON
TO DUPLICATE OR TO MAKE COPIES FOR
Residence
MR. NORIEL CRUZ & MRS.NENITA CRUZ
NOTED BY: